2
TRANSMISSION LINE BOQ (FROM SUBSTATION TO STP- 2.5KM) SR.NO. DEASRIPTION QUANTITY 1 14 2 70 3 4 4 2 5 10 6 H farme for fixing the GOS as per bill of material and drawing. 2 7 2 8 2 9 2 10 45 KN 11 kV class Disc insulator Cortor & Pin type as per specification. 42 11 11 kV class Pin insulator with GI pin as per drawing and specification. 210 12 21 13 300 14 Ground wire for grounding of the transformer center. 80 15 Rabbit ACSR conductor as per specifications. 10.4 16 Strain insulatros Bolts and Nuts type as per drawing and specification. 18 17 21 9.0 mtr long 145 kg WL ( Using Tor-50 Steel) RCC pole as per the specification. 9.0 mtr long 200 kg WL ( Using Tor-50 Steel) PSC pole as per the specification. Double pole structure complete with 2-pole structure kit and 2 Nos. of 9.0 mtr long 145 kg WL ( Using Tor-50 Steel) RCC pole as per the specification and bill of materials. Transformer structure complete with cross arms, braces, clamps, bolts and nuts and washer using 2 Nos. of 9.0 mtr long 145 kg WL ( Using Tor- 50 Steel) RCC pole for 250 kVA transformer center as per the specification and bill of materials. 11 kV Horizontal cross arm with HT single top support, clamps, Bolts&Nuts, and washers suitable for RCC poles as per specifications. Anti claimbig device with fixing clamps, Bolts & Nuts and washer etc., as per specification. Danger board with fixing clamps, Bolts & Nuts and washer etc., as per specification. 2 Nos. of of bird guard with fixing clamps, Bolts & Nuts and washer etc., as per specification. Guy set with No 15 strain insulators, Guy rod, 7/10 SWG Guy wire, clamps, trun buckle, Anchor rod using 12 mm round, etc., as per the specification. GI wire 8 SWG for guarding set (50 kg per guarding set) and grounding of the transformer center. C type fired Wedge connector sutibal for Rabbit ACSR conductor as per specification.

Upload: rohan-gurav

Post on 15-Sep-2015

11 views

Category:

Documents


4 download

DESCRIPTION

11KV transmission line bill of quantity

TRANSCRIPT

TRANSMISSION LINETRANSMISSION LINE BOQ (FROM SUBSTATION TO STP- 2.5KM)SR.NO.DEASRIPTIONQUANTITYUNIT19.0 mtr long 145 kg WL ( Using Tor-50 Steel) RCC pole as per the specification.14No.29.0 mtr long 200 kg WL ( Using Tor-50 Steel) PSC pole as per the specification.70No.3Double pole structure complete with 2-pole structure kit and 2 Nos. of 9.0 mtr long 145 kg WL ( Using Tor-50 Steel) RCC pole as per the specification and bill of materials.4Set4Transformer structure complete with cross arms, braces, clamps, bolts and nuts and washer using 2 Nos. of 9.0 mtr long 145 kg WL ( Using Tor-50 Steel) RCC pole for 250 kVA transformer center as per the specification and bill of materials.2Set511 kV Horizontal cross arm with HT single top support, clamps, Bolts&Nuts, and washers suitable for RCC poles as per specifications.10Set6H farme for fixing the GOS as per bill of material and drawing.2Nos.7Anti claimbig device with fixing clamps, Bolts & Nuts and washer etc., as per specification.2Set8Danger board with fixing clamps, Bolts & Nuts and washer etc., as per specification.2No92 Nos. of of bird guard with fixing clamps, Bolts & Nuts and washer etc., as per specification.2No1045 KN 11 kV class Disc insulator Cortor & Pin type as per specification.42No1111 kV class Pin insulator with GI pin as per drawing and specification.210No12Guy set with No 15 strain insulators, Guy rod, 7/10 SWG Guy wire, clamps, trun buckle, Anchor rod using 12 mm round, etc., as per the specification.21No13GI wire 8 SWG for guarding set (50 kg per guarding set) and grounding of the transformer center.300kgs14Ground wire for grounding of the transformer center.80kg15Rabbit ACSR conductor as per specifications.10.4kms16Strain insulatros Bolts and Nuts type as per drawing and specification.18No17C type fired Wedge connector sutibal for Rabbit ACSR conductor as per specification.21No