transparency tube as a surrogate for turbidity, suspended ... · • the transparency tube was a...

14
Nicole Reid, Jane Herbert , and Dean Baas MSU Extension Land & Water Program W. K. Kellogg Biological Station Transparency tube as a surrogate for turbidity, suspended solids and total phosphorus in rivers and reservoirs

Upload: others

Post on 03-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Transparency tube as a surrogate for turbidity, suspended ... · • The transparency tube was a good predictor of turbidity (R2=0.78) Transparency tube and turbidity measures similar

Nicole Reid, Jane Herbert , and Dean Baas

MSU Extension Land & Water Program

W. K. Kellogg Biological Station

Transparency tube as a surrogate for turbidity, suspended solids and total phosphorus in rivers and reservoirs

Page 2: Transparency tube as a surrogate for turbidity, suspended ... · • The transparency tube was a good predictor of turbidity (R2=0.78) Transparency tube and turbidity measures similar

Transparency Tube

Transparency – a measure of how much light passes through the water. Transparency is effected by turbidity

Turbidity – measurement of the amount of light scattered by particles in the water.

Particles: sand, clay and algae

120 cm tall clear plastic tube with a Secchi disk pattern at the bottom and ruler (cm) along side. The tube measures water transparency in streams.

Some effects of high turbidity on water quality• Increase in Temperature

• Decrease in Oxygen• Decrease in light penetration

• Lost of habitat for aquatic organisms• REDUCES WATER CLARITY

Page 3: Transparency tube as a surrogate for turbidity, suspended ... · • The transparency tube was a good predictor of turbidity (R2=0.78) Transparency tube and turbidity measures similar

Nutrient loading effects water clarity. Phosphorus when added inexcess leads to eutrophication which reduces water quality by reducing water transparency.

Total phosphorus is a combination of soluble reactive phosphorus(SRP), dissolved phosphorus (DP), and particulate phosphorus (PP).

An estimate of TP can be predicted by PP in streams under certain conditions.

Particle phosphorus could be an indicator that volunteers can use to estimate total phosphorus in streams

Phosphorus

Page 4: Transparency tube as a surrogate for turbidity, suspended ... · • The transparency tube was a good predictor of turbidity (R2=0.78) Transparency tube and turbidity measures similar

Kalamazoo River watershed

Six run-of-river impoundments on the main stem

Small tributary discharge varied from 24 - 63 cfs, main stem discharged varied from 640 – 2340 cfs

Thirteen sampling sites, including tributaries were sampled once a week for 10 weeks (June-September 2005).

To evaluate the effectiveness of using transparency tubes to estimate total suspended solids (TSS), turbidity (NTU), and

total phosphorus (TP) for the purpose of establishing a volunteer phosphorus monitoring network.

Area: 5,230 km2

Project Objective

Page 5: Transparency tube as a surrogate for turbidity, suspended ... · • The transparency tube was a good predictor of turbidity (R2=0.78) Transparency tube and turbidity measures similar

Methods

Samples were

collected without

disturbing sediments or surface

debris

Tube was filled

Water was released back into the bucket

Released valve was closed when

Secchi disk becomes barely visible (target

endpoint)

The height of the water was recorded. The average of two readings was final transparency reading.

Turbidity reading were taken on site

and TSS and TP were determine by lab analysis

Page 6: Transparency tube as a surrogate for turbidity, suspended ... · • The transparency tube was a good predictor of turbidity (R2=0.78) Transparency tube and turbidity measures similar

Turbidity (n=115)

y = -1.1353x + 2.9926R2 = 0.77

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

0.0 0.5 1.0 1.5 2.0 2.5Log Transparency tube (cm)

Log

Turb

idity

(NTU

)

Page 7: Transparency tube as a surrogate for turbidity, suspended ... · • The transparency tube was a good predictor of turbidity (R2=0.78) Transparency tube and turbidity measures similar

Total suspended solids (n=115)

y = -1.1486x + 3.0624R2 = 0.54

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

0.0 0.5 1.0 1.5 2.0 2.5Log Transparency tube (cm)

Log

Tota

l sus

pend

ed s

olid

s

Page 8: Transparency tube as a surrogate for turbidity, suspended ... · • The transparency tube was a good predictor of turbidity (R2=0.78) Transparency tube and turbidity measures similar

Total phosphorus (n=115)

y = -107.029x + 264.345R2 = 0.426

0

20

40

60

80

100

120

140

160

180

1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2

Log Transparency Tube (cm)

Tota

l Pho

spho

rus

( μg/

L)

Page 9: Transparency tube as a surrogate for turbidity, suspended ... · • The transparency tube was a good predictor of turbidity (R2=0.78) Transparency tube and turbidity measures similar

• The transparency tube was a good predictor of turbidity (R2=0.78)

Transparency tube and turbidity measures similar stream properties (scattering of light by particulates)

•The decrease in correlation with total suspended solids (R2=0.55)

Particles vary in size, shape, and composition within a stream.

Indicating that there is no universal relationship among sites and so the sites are unique

Results

•Site uniqueness pattern continues for total phosphorus concentrations in streams (R2=0.42)

Total phosphorus has 3 forms and those forms may vary in concentration and particulate (PP) form is important for transparency.

Page 10: Transparency tube as a surrogate for turbidity, suspended ... · • The transparency tube was a good predictor of turbidity (R2=0.78) Transparency tube and turbidity measures similar

Site specific factors to Kalamazoo River:

• Ratio of DP:PP, particles have greater impact on transparency than color

•Point source discharge, 2 WWTF have unstable inputs

•Impoundments, sink or source for sediments, and promote algal growth

100.899Schnable Brook

70.870Battle Creek River

80.854Gun River

100.755Kalamazoo River in Battle Creek

100.707Portage Creek

90.689Kalamazoo River east of Battle Creek

100.635Kalamazoo River at Lake Allegan Inlet

70.528Kalamazoo River at Morrow Lake Inlet

100.514Kalamazoo River at Lake Allegan Outlet

100.469Kalamazoo River at Comstock

70.396Eagle Lake Tributary

100.239Kalamazoo River at Plainwell

70.002Battle Creek River at Emmett St. Dam

DP to PP

Ratio > 1

Point Source

Influence

Impound-ment

InfluenceNR2Sample Location

100.899Schnable Brook

70.870Battle Creek River

80.854Gun River

100.755Kalamazoo River in Battle Creek

100.707Portage Creek

90.689Kalamazoo Rivereast of Battle Creek

100.635Kalamazoo River at Lake Allegan Inlet

70.528Kalamazoo River at Morrow Lake Inlet

100.514Kalamazoo River at Lake Allegan Outlet

100.469Kalamazoo River at Comstock

70.396Eagle Lake Tributary

100.239Kalamazoo River at Plainwell

70.002Battle Creek River at Emmett St. Dam

DP to PP

Ratio > 1

Point Source

Influence

Impound-ment

InfluenceNR2Sample Location

Log transparency versus TP

Page 11: Transparency tube as a surrogate for turbidity, suspended ... · • The transparency tube was a good predictor of turbidity (R2=0.78) Transparency tube and turbidity measures similar

Training volunteers to use transparency tubes, Fall 2005 and Spring 2006

Method Protocol

•9-12 volunteers

•Trained using practice bucket of different transparency using same methods

•Aiming for +/- 5 cm reading from reference reading

•Focus on the individual skill training and not the group

•Comfortably identify the target endpoint without over shooting (subjective reading)

Training “endpoint” as it comes into view.

Page 12: Transparency tube as a surrogate for turbidity, suspended ... · • The transparency tube was a good predictor of turbidity (R2=0.78) Transparency tube and turbidity measures similar

Location Protocol

• Site selection based on strong correlation between transparency

and total phosphorus

•Sampling frequency once every 14 days

•Point source lab provided volunteer TP lab analysis (samples

were collected on the same day as T. tube reading)

•Volunteers entered data on website

Training volunteers to use transparency tubes, Fall 2005 and Spring 2006

Page 13: Transparency tube as a surrogate for turbidity, suspended ... · • The transparency tube was a good predictor of turbidity (R2=0.78) Transparency tube and turbidity measures similar

Conclusions

Data

Water clarity measured by transparency tube provided information for general water quality (turbidity)

Establish individual site correlation each site is unique and influence by site characteristics

Volunteer program

Focus on outdoor individual skill training in order to develop consistent transparency tube readings

Focus on recognizing the target endpoint – DO NOT go pass target endpoint

Estimates of total phosphorus in certain sites can be obtained with transparency tube in volunteer hands

Page 14: Transparency tube as a surrogate for turbidity, suspended ... · • The transparency tube was a good predictor of turbidity (R2=0.78) Transparency tube and turbidity measures similar

Acknowledgments

CSREES Water Quality Program

David Weed – Total phosphorus lab analysis

Kalamazoo River/Lake Allegan TMDL Implementation Committee

Kellogg Biological Station