transparent tubular level gauge “ttg” · • offset valves permit cleaning of gauge glass &...
TRANSCRIPT
• Offset valves permit cleaning of gauge glass & its removal on line
• Wide choice of MOC
• IBR certified gauge for steam service on demand
• PTFE lined gauge for corrosive liquids
Salient Features
Construction & OperationGauge is fitted between two end blocks through gland packings. The gauge is mounted parallel to tank so as to form a close loop, causing tank liquid to seek its level in the gauge. ‘C’ channels/ tie rods are provided to protect gauge from accidental blows. End blocks are provided with vent plug, drain valve & integral offset valves.
TRANSPARENT TUBULAR LEVEL GAUGE “TTG”
Simple, low cost and reliable gauge for direct reading of clean liquid levels at low temperature and pressure conditions.
We Measure the Best for You!
Metallic End block PP End block
Schematic Diagram
ProcessFlanges
95(max)
85
Vent Plug
End Block
Gland
GuardCal.Scale
Gauge
Gland
PackingGuard Holder
Adapter
DrainValve
(max)
CC D
ist(
mm
)
Vis
ibili
ty
OPENING
OPENING
ScrewedProcess
Connection
CC D
IST±
1
100
Ptfe Lined
TricloverProcess
Connection
Triclover Ferrule with Clamp
Triclover Ferrule with Clamp
1282
Dual Section with Flanged Coupler Arrangement
Metallic/PP/ PVDF End Block Flanged Connection
Metallic End Block with Triclover Connection
Metallic End Block with Screwed Connection
PTFE lined SS304 End Block with Flanged Connection
x = 1)180mm(metallic) 2) 210mm (pp)
mm
mm
mm
mm
mm
mm
OPENS
HU
T
OPENS
HU
T
Coup
ler
Arra
ngem
ent
Visi
bilit
y
X
X= 1) 180mm (metallic)2) 210mm (pp)
We Measure the Best for You!
Note 1 - All CI/CS components are epoxy powder coated
Note 2 - Separate Datasheets are available for IBR
Specifications
Gauge Glass Tempered borosilicate heavy wall 16 mm, 19 mm or 25 mm ODEnd Block MOC CS /ASTM A105/ SS304
/316 /316LPP or Pvdf Ptfe lined SS304 with
16 mm OD GlassSanitary Finish SS316/
SS316L
End Block Type1) Without Valve 2) Integral Offset Needle Valve 3) Integral Offset Needle Valve with autoball check
Without Valve Without Valve
Autoball Check MOC SS316/SS316LPP/ Pvdf capsule with
Ptfe ballNA NA
‘C’ Channel Guards CS, SS304, SS316 FRP SS304 SS304Tie Rods Guards CS, SS304 CS, SS304 SS304 SS304Packing PtfeGland MOC CI / SS316 PP SS316 SS316Process Connection Flanged, Screwed Flanged Flanged Triclover Ferrule
Vent & Drain MOCCS/ASTM A105/ SS304/
SS316/ SS316LPP or Pvdf Ptfe SS316/316L
Vent 16 mm Gauge Glass19 mm Gauge Glass25 mm Gauge Glass
½” BSP Plug or Ball Valve (with Plug if reqd.)3/4” BSP Plug or Ball Valve (with Plug if reqd.) 1” BSP Plug or Ball Valve (with Plug if reqd.)
½” BSP Ptfe Plug or 1”NB Ptfe lined SS304
Flanged Ball Valve
Triclover Ferrule with Clamp
Drain ½” BSP Plug or Ball Valve (with Plug if reqd.)
½” BSP Ptfe Plug or 1” NB Ptfe lined SS304
Flanged Ball Valve
Triclover Ferrule with Clamp
Scale MOC Polycarbonate (screen printed), SS304 (etched) Scale Calibration mm ( LC= 5 mm ), cm ( LC= 0.5 cm )
CC Distance 300 to 1500 mm in single section, and upto 3000 mm in dual section. Dual section achieved through
flanged coupler.Visibility CC Distance – 150 mm
Max Temperature 200 °C70 °C PP
100 °C Pvdf100 °C 200 °C
Test Pressure at Amb Temp
Vacuum to 10 Kg/cm2 Vacuum to 2 Kg/cm2 Vacuum to 2 Kg/cm2 Vacuum to 10 Kg/cm2
Accessories1) Tank isolation valves with nuts, bolts & gaskets2) Counter flanges with nuts, bolts & gaskets
Special Features Glass Protector 3 mm thick perspex shield to protect gauge glass and for personnel safetyAuto Ball Check SS316 or PTFE ball to minimize liquid loss during glass breakageFrost-free 20 mm thk x 35 mm extension perspex shield to prevent frost formation on outer surface of gauge glass
for clear visual reading of liquid at low temp. Illuminator To provide uniform light along the length of gauge glass in poorly lit area. It consists of perspex reflector,
illuminated through a LED bulb, 80 to 250 VAC with Al. Enclosure IP65 /Ex d Gr IIB or IIC. The length of single illuminator is 1200 mm max.
Jacketing For preventing solidification of process liquid. It consists of a SS pipe with "NPT (F)” inlet & outlet at bottom & top end blocks for heating/cooling agent.
We Measure the Best for You!
1/2"NPT(F)Inlet
1/2"NPT(F) Outlet
SS Pipe
FerruleLocknut
Jacket
Heating/Cooling Agent
Drain Plug
Vent Plug
Clamp
Extension
Drain Plug
ProtectivePerspex
Illuminator Assy.
Perspex Sheet
Drain Plug
Schematic Diagram of Gauge with Special Feature
With Illuminator With Frost Free Extn. With Jacketing
It consists of a capsule and free moving ball along its inner race, between the stopper & orifice. During glass breakage, the high pressure from vessel side (Optg. Pr + Liquid Column) moves the ball to block the orifice and minimize liquid loss from tank.
Typical Installations
Vent Plug
Integral Offset Gauge Valve
Drain Valve
Isolating Valves
TankCC Dist(mm)
GaugeFlange
Buyer`s scope
TANK
Cla
mp
Nuts
CC Dist(mm)
Buyer`s scope
TANK`Y'
Detail at`Y'
Gauge connection1"NPT(M)
Tank connection1"NPT(F)
`x'
(PCD & holes orientation)
Detail at`X'
Gauge TankFlange Flange
Clamp Nut
Matching Threads
FLANGED
Matching Flanges
SCREWED
TANK
Tric
love
r Fe
rrul
esCC Dist(mm)
Buyer`s scope
`Z'
FERRULESDetail at`Z'
ClampTriclover Ferrule
Matching Ferrules
Sanitary applicationNon-Sanitary application Non-Sanitary application
TRICLOVER
Applications: 4Storage /Process Tanks of Water, Brine, Oils, Solvents, Alcohol, Diesels .4Dosing Tanks of Acids & Alkalies in WTP, STP and ETP .
Working of Autoball Check
capsule
We measure the best for you!We Measure the Best for You!
1 M WV I1 3 1 1 2 1
Model Identification TTG
1. Gauge Glass Size16 mm OD 125 mm OD 219 mm OD 32. End Block MOC CS MASTM A105 ASS304 NSS316 SSS316L LPP PPvdf DPtfe lined SS304 TOthers O 3. End Block Type Without Valve WIntegral Offset Needle Valve VIntegral Offset Needle Valve with Auto Ball Check AOthers O
4. GuardsCS ‘C’ Channels 1FRP ‘C’ Channels 2SS304 ‘C’ Channels 3CS Tie Rods 4SS304 Tie Rods 5SS316 ‘C’ Channels 6Others O
5. Gland MOCCI ISS316 SPP P6. Process Connection Size 1/2” 13/4” 21” 31-1/2” 4Others O
7. Process Connection Type ASME 150# Flange 1DIN Flange 2BSP (M) Screwed 3NPT (M) Screwed 4Triclover Ferrule 5Others O
PUNE TECHTROL PRIVATE LIMITEDRegd. & Sales: S-18, MIDC Bhosari, Pune - 411026, India +91-20-66342900 | [email protected]
Works: J-52/7, MIDC Bhosari, Pune - 411026, India+91-20-67313600 | www.punetechtrol.com
CAT/0002/REV 08/04-19We Measure the Best for You!
*All d
imen
sion
s in
mm
exc
ept s
peci
fied
Ordering Information
Model No x Liquid x Operating Temperature & Pressure x Accessories (optional)
8. Vent and Drain Size1/2” BSP x 1/2” BSP 1
3/4” BSP x 1/2” BSP 2
1” BSP x 1/2” BSP 3Others O
9. Vent and Drain TypePlug x Plug 1
Plug x Ball Valve 2
Plug x Ball Valve with Plug 3
Ball Valve x Ball Valve 4
Ball Valve with Plug x Ball Valve with Plug 5
Flanged Ball Valve x Flanged Ball Valve 6
Others O
10. Calibrated ScaleWithout W
Polycarbonate in mm (LC= 5 mm) 1
SS304 in mm (LC= 5 mm) 2
SS304 in cm (LC = 0.5 cm) 3
Others O
11. Special FeaturesWithout W
Frost Free F
Illuminator I
Jacketing J
Glass Protector G