transparent tubular level gauge “ttg” · • offset valves permit cleaning of gauge glass &...

5
Offset valves permit cleaning of gauge glass & its removal on line Wide choice of MOC IBR certified gauge for steam service on demand PTFE lined gauge for corrosive liquids Salient Features Construction & Operation Gauge is fitted between two end blocks through gland packings. The gauge is mounted parallel to tank so as to form a close loop, causing tank liquid to seek its level in the gauge. ‘C’ channels/ tie rods are provided to protect gauge from accidental blows. End blocks are provided with vent plug, drain valve & integral offset valves. TRANSPARENT TUBULAR LEVEL GAUGE “TTG” Simple, low cost and reliable gauge for direct reading of clean liquid levels at low temperature and pressure conditions. We Measure the Best for You! Metallic End block PP End block Schematic Diagram Process Flanges 95 (max) 85 Vent Plug End Block Gland Guard Cal.Scale Gauge Gland Packing Guard Holder Adapter Drain Valve (max) CC Dist(mm) Visibility OPENING OPENING Screwed Process Connection CC DIST±1 100 Ptfe Lined Triclover Process Connection Triclover Ferrule with Clamp Triclover Ferrule with Clamp 1282 Dual Section with Flanged Coupler Arrangement Metallic/PP/ PVDF End Block Flanged Connection Metallic End Block with Triclover Connection Metallic End Block with Screwed Connection PTFE lined SS304 End Block with Flanged Connection x = 1)180mm(metallic) 2) 210mm (pp) Coupler Arrangement Visibility X X= 1) 180mm (metallic)

Upload: others

Post on 22-Sep-2019

2 views

Category:

Documents


0 download

TRANSCRIPT

• Offset valves permit cleaning of gauge glass & its removal on line

• Wide choice of MOC

• IBR certified gauge for steam service on demand

• PTFE lined gauge for corrosive liquids

Salient Features

Construction & OperationGauge is fitted between two end blocks through gland packings. The gauge is mounted parallel to tank so as to form a close loop, causing tank liquid to seek its level in the gauge. ‘C’ channels/ tie rods are provided to protect gauge from accidental blows. End blocks are provided with vent plug, drain valve & integral offset valves.

TRANSPARENT TUBULAR LEVEL GAUGE “TTG”

Simple, low cost and reliable gauge for direct reading of clean liquid levels at low temperature and pressure conditions.

We Measure the Best for You!

Metallic End block PP End block

Schematic Diagram

ProcessFlanges

95(max)

85

Vent Plug

End Block

Gland

GuardCal.Scale

Gauge

Gland

PackingGuard Holder

Adapter

DrainValve

(max)

CC D

ist(

mm

)

Vis

ibili

ty

OPENING

OPENING

ScrewedProcess

Connection

CC D

IST±

1

100

Ptfe Lined

TricloverProcess

Connection

Triclover Ferrule with Clamp

Triclover Ferrule with Clamp

1282

Dual Section with Flanged Coupler Arrangement

Metallic/PP/ PVDF End Block Flanged Connection

Metallic End Block with Triclover Connection

Metallic End Block with Screwed Connection

PTFE lined SS304 End Block with Flanged Connection

x = 1)180mm(metallic) 2) 210mm (pp)

mm

mm

mm

mm

mm

mm

OPENS

HU

T

OPENS

HU

T

Coup

ler

Arra

ngem

ent

Visi

bilit

y

X

X= 1) 180mm (metallic)2) 210mm (pp)

We Measure the Best for You!

Note 1 - All CI/CS components are epoxy powder coated

Note 2 - Separate Datasheets are available for IBR

Specifications

Gauge Glass Tempered borosilicate heavy wall 16 mm, 19 mm or 25 mm ODEnd Block MOC CS /ASTM A105/ SS304

/316 /316LPP or Pvdf Ptfe lined SS304 with

16 mm OD GlassSanitary Finish SS316/

SS316L

End Block Type1) Without Valve 2) Integral Offset Needle Valve 3) Integral Offset Needle Valve with autoball check

Without Valve Without Valve

Autoball Check MOC SS316/SS316LPP/ Pvdf capsule with

Ptfe ballNA NA

‘C’ Channel Guards CS, SS304, SS316 FRP SS304 SS304Tie Rods Guards CS, SS304 CS, SS304 SS304 SS304Packing PtfeGland MOC CI / SS316 PP SS316 SS316Process Connection Flanged, Screwed Flanged Flanged Triclover Ferrule

Vent & Drain MOCCS/ASTM A105/ SS304/

SS316/ SS316LPP or Pvdf Ptfe SS316/316L

Vent 16 mm Gauge Glass19 mm Gauge Glass25 mm Gauge Glass

½” BSP Plug or Ball Valve (with Plug if reqd.)3/4” BSP Plug or Ball Valve (with Plug if reqd.) 1” BSP Plug or Ball Valve (with Plug if reqd.)

½” BSP Ptfe Plug or 1”NB Ptfe lined SS304

Flanged Ball Valve

Triclover Ferrule with Clamp

Drain ½” BSP Plug or Ball Valve (with Plug if reqd.)

½” BSP Ptfe Plug or 1” NB Ptfe lined SS304

Flanged Ball Valve

Triclover Ferrule with Clamp

Scale MOC Polycarbonate (screen printed), SS304 (etched) Scale Calibration mm ( LC= 5 mm ), cm ( LC= 0.5 cm )

CC Distance 300 to 1500 mm in single section, and upto 3000 mm in dual section. Dual section achieved through

flanged coupler.Visibility CC Distance – 150 mm

Max Temperature 200 °C70 °C PP

100 °C Pvdf100 °C 200 °C

Test Pressure at Amb Temp

Vacuum to 10 Kg/cm2 Vacuum to 2 Kg/cm2 Vacuum to 2 Kg/cm2 Vacuum to 10 Kg/cm2

Accessories1) Tank isolation valves with nuts, bolts & gaskets2) Counter flanges with nuts, bolts & gaskets

Special Features Glass Protector 3 mm thick perspex shield to protect gauge glass and for personnel safetyAuto Ball Check SS316 or PTFE ball to minimize liquid loss during glass breakageFrost-free 20 mm thk x 35 mm extension perspex shield to prevent frost formation on outer surface of gauge glass

for clear visual reading of liquid at low temp. Illuminator To provide uniform light along the length of gauge glass in poorly lit area. It consists of perspex reflector,

illuminated through a LED bulb, 80 to 250 VAC with Al. Enclosure IP65 /Ex d Gr IIB or IIC. The length of single illuminator is 1200 mm max.

Jacketing For preventing solidification of process liquid. It consists of a SS pipe with "NPT (F)” inlet & outlet at bottom & top end blocks for heating/cooling agent.

We Measure the Best for You!

1/2"NPT(F)Inlet

1/2"NPT(F) Outlet

SS Pipe

FerruleLocknut

Jacket

Heating/Cooling Agent

Drain Plug

Vent Plug

Clamp

Extension

Drain Plug

ProtectivePerspex

Illuminator Assy.

Perspex Sheet

Drain Plug

Schematic Diagram of Gauge with Special Feature

With Illuminator With Frost Free Extn. With Jacketing

It consists of a capsule and free moving ball along its inner race, between the stopper & orifice. During glass breakage, the high pressure from vessel side (Optg. Pr + Liquid Column) moves the ball to block the orifice and minimize liquid loss from tank.

Typical Installations

Vent Plug

Integral Offset Gauge Valve

Drain Valve

Isolating Valves

TankCC Dist(mm)

GaugeFlange

Buyer`s scope

TANK

Cla

mp

Nuts

CC Dist(mm)

Buyer`s scope

TANK`Y'

Detail at`Y'

Gauge connection1"NPT(M)

Tank connection1"NPT(F)

`x'

(PCD & holes orientation)

Detail at`X'

Gauge TankFlange Flange

Clamp Nut

Matching Threads

FLANGED

Matching Flanges

SCREWED

TANK

Tric

love

r Fe

rrul

esCC Dist(mm)

Buyer`s scope

`Z'

FERRULESDetail at`Z'

ClampTriclover Ferrule

Matching Ferrules

Sanitary applicationNon-Sanitary application Non-Sanitary application

TRICLOVER

Applications: 4Storage /Process Tanks of Water, Brine, Oils, Solvents, Alcohol, Diesels .4Dosing Tanks of Acids & Alkalies in WTP, STP and ETP .

Working of Autoball Check

capsule

We measure the best for you!We Measure the Best for You!

1 M WV I1 3 1 1 2 1

Model Identification TTG

1. Gauge Glass Size16 mm OD 125 mm OD 219 mm OD 32. End Block MOC CS MASTM A105 ASS304 NSS316 SSS316L LPP PPvdf DPtfe lined SS304 TOthers O 3. End Block Type Without Valve WIntegral Offset Needle Valve VIntegral Offset Needle Valve with Auto Ball Check AOthers O

4. GuardsCS ‘C’ Channels 1FRP ‘C’ Channels 2SS304 ‘C’ Channels 3CS Tie Rods 4SS304 Tie Rods 5SS316 ‘C’ Channels 6Others O

5. Gland MOCCI ISS316 SPP P6. Process Connection Size 1/2” 13/4” 21” 31-1/2” 4Others O

7. Process Connection Type ASME 150# Flange 1DIN Flange 2BSP (M) Screwed 3NPT (M) Screwed 4Triclover Ferrule 5Others O

PUNE TECHTROL PRIVATE LIMITEDRegd. & Sales: S-18, MIDC Bhosari, Pune - 411026, India +91-20-66342900 | [email protected]

Works: J-52/7, MIDC Bhosari, Pune - 411026, India+91-20-67313600 | www.punetechtrol.com

CAT/0002/REV 08/04-19We Measure the Best for You!

*All d

imen

sion

s in

mm

exc

ept s

peci

fied

Ordering Information

Model No x Liquid x Operating Temperature & Pressure x Accessories (optional)

8. Vent and Drain Size1/2” BSP x 1/2” BSP 1

3/4” BSP x 1/2” BSP 2

1” BSP x 1/2” BSP 3Others O

9. Vent and Drain TypePlug x Plug 1

Plug x Ball Valve 2

Plug x Ball Valve with Plug 3

Ball Valve x Ball Valve 4

Ball Valve with Plug x Ball Valve with Plug 5

Flanged Ball Valve x Flanged Ball Valve 6

Others O

10. Calibrated ScaleWithout W

Polycarbonate in mm (LC= 5 mm) 1

SS304 in mm (LC= 5 mm) 2

SS304 in cm (LC = 0.5 cm) 3

Others O

11. Special FeaturesWithout W

Frost Free F

Illuminator I

Jacketing J

Glass Protector G