trench heating - vkn silent · 2019-10-01 · trench heater acoustic measures” and report no...

12
1 www.verano-global.com VKN SILENT Fan assisted trench heaters. 10 cm height 2019_08

Upload: others

Post on 08-Aug-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Trench heating - VKN SILENT · 2019-10-01 · Trench Heater Acoustic measures” and report no 5/2017 “VKN5 9/25 In-floor Fan Assisted Trench Heater Acoustic measures” both executed

1 w w w . v e r a n o - g l o b a l . c o m

VKN SILENTFan assisted trench heaters. 10 cm height

2019_08

Page 2: Trench heating - VKN SILENT · 2019-10-01 · Trench Heater Acoustic measures” and report no 5/2017 “VKN5 9/25 In-floor Fan Assisted Trench Heater Acoustic measures” both executed

2 w w w . v e r a n o - g l o b a l . c o m

High thermal output complementing minimum noise level!Ideal for any rooms and chambers with the extreme low noise level requirement our fan assisted trench heaters add energy efficiency and high thermal output on the top.

We have modified the construction of the heat exchanger and used the different type of the fan impeller/motor. Everything we accomplished for quieter work and increased efficiency. Our newest 100 mm high VKN5 fan assisted trench heaters provide improved noise level, with the like other models’ thermal duties, respectively.

On the chart we present the comparison of the acoustic power for the selected frequencies. All figures have been included based on the results report no 4/2017 “VKN5 10/25 In-floor Fan Assisted Trench Heater Acoustic measures” and report no 5/2017 “VKN5 9/25 In-floor Fan Assisted Trench Heater Acoustic measures” both executed by Heating Department of the Energy Affairs Institute in Lodz/Poland.

Shhh!

16

18

20

22

24

26

28

30

200 400 800 1600

Pozi

om m

ocy

akus

tycz

nej L

w, d

B

Wybrane częstotoliwości f, Hz

VKN5-9/25 - MED VKN5-10/25 - MAX

3dB less that means the noise

reduced by half

OUR REFERENCE JOB FROM THE FIRST PAGE

• The National Parliament building in Warsaw/Poland

VKN SILENT fan assisted trench heaters operate as energy efficient heating emitters for this building.

ETO – Engineered to Order

The rooms and chambers in the Parliament Building required heating emitters with a total minimum noise level. We designed the brand-new model exclusively for this project to meet the highest and the most rigorous noise level requirements, usually the same that are for broadcasting rooms.

Selected frequencies F, Hz

The

acco

ustic

pow

er le

vel L

w, d

B

Page 3: Trench heating - VKN SILENT · 2019-10-01 · Trench Heater Acoustic measures” and report no 5/2017 “VKN5 9/25 In-floor Fan Assisted Trench Heater Acoustic measures” both executed

3 w w w . v e r a n o - g l o b a l . c o m

STANDARD EQUIPMENT :

• Casing made of galvanised steel sheet in RAL 9005 black,

• Highly efficient copper-aluminium heat exchanger with air vent,

• Modern fan with silent end efficient 24 V DC motor,

• Connection space cover,

• Fan cover with airflow baffle,

• ½” connection threads,

• Assembly struts,

• Fastening anchors,

• Trench positioning adjustment system.

ADDITIONAL EQUIPMENT:

• Casing made of galvanised steel sheet in any RAL colour,

• Decorative frames that run around the trench casing attached to the grille support edge: frames can be L or F shape, made of natural or anodised aluminium,

• Decorative grille,

• Assembly protection fibreboard for transpor-ting and installation,

• Raised floor kit,

• Bimetallic temperature sensor,

• Adjustable grille support edge for trench casing (requires making 5mm wider casing),

• Casing protective film,

• Foil sleeve for heat exchanger,

• Anti dust filter (requires raising the trench for 10mm)

• BMS control*.

VKN1 HEIGHT 100 mm

EQUIPMENT DIMENSIONS

DIMENSIONS [mm]

Trench height (H) 100

Trench bottom width (B)

170

Top width/Grille width 194

Trench length (Lk) 650-2250

PR

OD

UC

T

VI

SU

AL

IZ

AT

IO

N

EXAMPLE ORDER CODE:

VKN1-10/17/Lk (L/P)

Trench length Lk [cm]

Connection side (L- Left/P - Right)

* - In case of trench high of 100mm the BMS controller should be assembled into the electrical fuse box.

Page 4: Trench heating - VKN SILENT · 2019-10-01 · Trench Heater Acoustic measures” and report no 5/2017 “VKN5 9/25 In-floor Fan Assisted Trench Heater Acoustic measures” both executed

4 w w w . v e r a n o - g l o b a l . c o m

DIMENSIONS UNIT [mm]

Trench height (H) 100

Trench bottom width (B) 170

Top width/Grille width 194

Trench length (Lk) 650-2250

CONNECTIONS T YPE

Connection threads1/2” female connection threads

Connection sideLeft (L) standard,Right (R) option

ACCESSORIES T YPE

Grille H=18 mm Roll-up / linear / modular

Frame L or F

Zalecana odległość od ściany 100-300 mmRecommended distance to the wall 100-300 mm

Length of trench heater (Lk)

194170

100

194

170

18

HEIGHT 100 mm

VKN1-10/17/Lk (L/P)

Trench length

Operating mode

Heat output tf/tr °CSound pressure

levelSound power

levelElectric power

demandCurrent

Number of fan motors

Lk [mm] [-]75/65 °C 55/45 °C 35/30 °C

Lp [dB(A)] Lw [dB(A)] P [W] I [A] [-]Φ [W]

650

Min 230 133 52 <18 <26 1,0 0,04

1Med 465 269 105 <18 <26 1,4 0,06Max 697 403 158 20 28 2,9 0,12

Boost 1019 589 231 32 <26 8,4 0,35

1050

Min 470 272 106 <18 <26 1,2 0,05

1Med 951 550 215 <18 <26 2,2 0,09Max 1425 824 322 21 29 4,3 0,18

Boost 2083 1205 471 32 40 12,0 0,5

1450

Min 709 410 160 <18 <26 1,0 0,04

1Med 1434 829 325 <18 <26 1,9 0,08Max 2149 1243 486 19 27 4,1 0,17

Boost 3142 1817 711 31 39 14,4 0,6

1850

Min 940 544 213 <18 <26 2,4 0,1

2Med 1901 1100 430 <18 <26 4,3 0,18Max 2850 1648 645 24 32 8,6 0,36

Boost 4167 2410 943 35 43 24,0 1

2250

Min 1179 682 267 <18 <26 2,2 0,09

2Med 2384 1379 540 <18 <26 4,1 0,17Max 3574 2067 809 23 31 8,4 0,35

Boost 5225 3022 1182 35 43 26,4 1,1

ORDER CODE

• Standard heating output [W] compliant to EN-16430, room air temperature Ɵi = 20°C.• Control voltages for the respective modes of operation: Min – 2 V, Med – 4 V, Max – 6 V, Boost – 10 V.• Min, Med, Max fan speeds are for continuous operations, the Boost mode is for speed room heating.• We recommend making a selection for MAX fan speed. • Sound power level according to ISO-3745 standard, sound pressure level measured at distance of 2 m to the heater, in a 100 m3 volume room.

Reverb time - 0,5 s, room damping - 8 dB(A)

Page 5: Trench heating - VKN SILENT · 2019-10-01 · Trench Heater Acoustic measures” and report no 5/2017 “VKN5 9/25 In-floor Fan Assisted Trench Heater Acoustic measures” both executed

5 w w w . v e r a n o - g l o b a l . c o m

10

2

3

4

5

6

7

8

9

0,0 0,5 1,0 1,5 2,0 0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5

10

2

3

4

5

6

7

8

9

0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5

10

2

3

4

5

6

7

8

9

2

3

4

5

6

7

8

9

10

0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0 6,5 7,0

0 1 2 3 4 5 6 7 8 9

10

2

3

4

5

6

7

8

9

8070605040302010 8070605040302010

8070605040302010 8070605040302010

8070605040302010

20

30

25

20

30

25

20

30

25

20

30

25

35

20

25

30

Lk=650 mm Lk=1050 mm

Lk=1450 mm Lk=1850 mm

Lk=2250 mm

HEAT OUTPUT AND SOUND PRESSURE OF VKN1-10/17/Lk

The graphs present how heat output Φ [W] depends on the respective average temperature differences ΔT [K], for control voltages U [V]. The graphs also present the sound pressure levels for the respective heater operating conditions.

Average temperature difference ΔT [K]

Cont

rol v

olta

ge U

[V]

Heat output Φ [kW]

Soun

d pr

essu

re L

p [d

B(A)

]

Average temperature difference ΔT [K]

Cont

rol v

olta

ge U

[V]

Heat output Φ [kW]

Soun

d pr

essu

re L

p [d

B(A)

]

Average temperature difference ΔT [K]

Cont

rol v

olta

ge U

[V]

Heat output Φ [kW]

Soun

d pr

essu

re L

p [d

B(A)

]

Average temperature difference ΔT [K]

Cont

rol v

olta

ge U

[V]

Heat output Φ [kW]

Soun

d pr

essu

re L

p [d

B(A)

]

Average temperature difference ΔT [K]

Cont

rol v

olta

ge U

[V]

Heat output Φ [kW]

Soun

d pr

essu

re L

p [d

B(A)

]

Page 6: Trench heating - VKN SILENT · 2019-10-01 · Trench Heater Acoustic measures” and report no 5/2017 “VKN5 9/25 In-floor Fan Assisted Trench Heater Acoustic measures” both executed

6 w w w . v e r a n o - g l o b a l . c o m

STANDARD EQUIPMENT :

• Casing made of galvanised steel sheet in RAL 9005 black,

• Highly efficient copper-aluminium heat exchanger with air vent,

• Modern fan with silent end efficient 24 V DC motor,

• Connection space cover,

• Fan cover with airflow baffle,

• ¾” connection half threads,

• Assembly struts,

• Fastening anchors,

• Trench positioning adjustment system.

ADDITIONAL EQUIPMENT:

• Casing made of galvanised steel sheet in any RAL colour,

• Decorative frames that run around the trench casing attached to the grille support edge: frames can be L or F shape, made of natural or anodised aluminium,

• Decorative grille,

• Assembly protection fibreboard for transpor-ting and installation,

• Raised floor kit,

• Bimetallic temperature sensor,

• Adjustable grille support edge for trench casing (requires making 5mm wider casing),

• Casing protective film

• Foil sleeve for heat exchanger,

• Anti dust filter (requires raising the trench for 10mm)

• BMS control*.

VKN5 HEIGHT 100 mm

EQUIPMENT DIMENSIONS

DIMENSIONS [mm]

Trench height (H) 100

Trench bottom width 250

Top width/Grille width 274

Trench length (Lk) 650-3550

EXAMPLE ORDER CODE:

VKN5-10/25/Lk (L/P)

Trench length Lk [cm]

Connection side (L- Left/P - Right)

PR

OD

UC

T

VI

SU

AL

IZ

AT

IO

N

* - For 100 mm high trench the BMS interface should be installed in the electric cupboard.

Page 7: Trench heating - VKN SILENT · 2019-10-01 · Trench Heater Acoustic measures” and report no 5/2017 “VKN5 9/25 In-floor Fan Assisted Trench Heater Acoustic measures” both executed

7 w w w . v e r a n o - g l o b a l . c o m

Recommended distance to the wall 100-300 mm

274

250

100

274

250

18

Length of trench heater (Lk)

VKN5 HEIGHT 100 mm

VKN5-10/25/Lk (L/P) ORDER CODE

Trench length

Operating mode

Heat output tf/tr °CSound pressure

levelSound power

levelElectric power

demandCurrent

Number of fan motors

Lk [mm] [-]75/65 °C 55/45 °C 35/30 °C

Lp [dB(A)] Lw [dB(A)] P [W] I [A] [-]Φ [W]

650

Min 283 164 64 <18 <26 1,0 0,04

1Med 521 301 118 <18 <26 1,4 0,06Max 663 383 150 20 28 2,9 0,12

Boost 820 474 186 32 <26 8,4 0,35

1050

Min 579 335 131 <18 <26 1,2 0,05

1Med 1065 616 241 <18 <26 2,2 0,09Max 1355 784 307 21 29 4,3 0,18

Boost 1676 969 379 32 40 12,0 0,5

1450

Min 873 505 198 <18 <26 1,0 0,04

1Med 1606 929 363 <18 <26 1,9 0,08Max 2044 1182 463 19 27 4,1 0,17

Boost 2528 1462 572 31 39 14,4 0,6

1850

Min 1157 669 262 <18 <26 2,4 0,1

2Med 2130 1232 482 <18 <26 4,3 0,18Max 2711 1568 614 24 32 8,6 0,36

Boost 3353 1939 759 35 43 24,0 1

2250

Min 1451 839 328 <18 <26 2,2 0,09

2Med 2672 1545 605 <18 <26 4,1 0,17Max 3400 1967 769 23 31 8,4 0,35

Boost 4205 2432 952 35 43 26,4 1,1

2650

Min 1745 1009 395 <18 <26 1,9 0,08

2Med 3213 1858 727 <18 <26 3,8 0,16Max 4089 2365 925 22 30 8,2 0,34

Boost 5057 2925 1144 34 42 28,8 1,2

3100

Min 2028 1173 459 <18 <26 1,9 0,08

3Med 3734 2160 845 18 26 3,8 0,16Max 4752 2749 1075 24 32 8,2 0,34

Boost 5877 3399 1330 36 44 28,8 1,2

3500

Min 2324 1344 526 <18 <26 3,1 0,13

3Med 4278 2474 968 19 27 6,0 0,25Max 5444 3149 1232 24 32 12,5 0,52

Boost 6733 3894 1524 35 43 40,8 1,7• Standard heating output [W] compliant to EN-16430, room air temperature Ɵi = 20°C.• Control voltages for the respective modes of operation: Min – 2 V, Med – 4 V, Max – 6 V, Boost – 10 V.• Min, Med, Max fan speeds are for continuous operations, the Boost mode is for speed room heating.• We recommend making a selection for MAX fan speed. • Sound power level according to ISO-3745 standard, sound pressure level measured at distance of 2 m to the heater, in a 100 m3 volume room.

Reverb time - 0,5 s, room damping - 8 dB(A)

DIMENSIONS UNIT [mm]

Trench height (H) 100

Trench bottom width (B) 250

Top width/Grille width 274

Trench length (Lk) 650-3500

CONNECTIONS T YPE

Connection threads¾” female connection half threads

Connection sideLeft (L) standard,Right (R) option

ACCESSORIES T YPE

Grille H=18 mm Roll-up / linear / modular

Frame L or F

Page 8: Trench heating - VKN SILENT · 2019-10-01 · Trench Heater Acoustic measures” and report no 5/2017 “VKN5 9/25 In-floor Fan Assisted Trench Heater Acoustic measures” both executed

8 w w w . v e r a n o - g l o b a l . c o m

HEAT OUTPUT AND SOUND PRESSURE OF VKN5-10/25/Lk

The graphs present how heat output Φ [W] depends on the respective average temperature differences ΔT [K], for control voltages U [V]. The graphs also present the sound pressure levels for the respective heater operating conditions.

0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 1,4 1,5

10

2

3

4

5

6

7

8

9

10

2

3

4

5

6

7

8

9

0,0 0,5 1,0 1,5 2,0 2,5 3,0

0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5

10

2

3

4

5

6

7

8

9

0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0

10

2

3

4

5

6

7

8

9

2

3

4

5

6

7

8

9

10

0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0 6,5 7,0 0 1 2 3 4 5 6 7 8 9

10

2

3

4

5

6

7

8

9

2

3

4

5

6

7

8

9

10

00 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 11 12

10

2

3

4

5

6

7

8

9

8070605040302010 8070605040302010

8070605040302010 8070605040302010

8070605040302010 8070605040302010

8070605040302010 8070605040302010

20

30

25

Lk=650 mm Lk=1050 mm

Lk=1450 mm Lk=1850 mm

Lk=2250 mm Lk=2650 mm

Lk=3100 mm Lk=3500 mm

20

30

25

20

30

25

20

30

25

35

20

25

30

20

25

30

20

25

30

35

20

25

30

35

Cont

rol v

olta

ge U

[V]

Cont

rol v

olta

ge U

[V]

Soun

d pr

essu

re L

p [d

B(A)

]

Soun

d pr

essu

re L

p [d

B(A)

]

Cont

rol v

olta

ge U

[V]

Cont

rol v

olta

ge U

[V]

Soun

d pr

essu

re L

p [d

B(A)

]

Soun

d pr

essu

re L

p [d

B(A)

]

Cont

rol v

olta

ge U

[V]

Cont

rol v

olta

ge U

[V]

Soun

d pr

essu

re L

p [d

B(A)

]

Soun

d pr

essu

re L

p [d

B(A)

]

Cont

rol v

olta

ge U

[V]

Cont

rol v

olta

ge U

[V]

Soun

d pr

essu

re L

p [d

B(A)

]

Soun

d pr

essu

re L

p [d

B(A)

]

Average temperature difference ΔT [K] Average temperature difference ΔT [K]

Heat output Φ [kW] Heat output Φ [kW]

Average temperature difference ΔT [K] Average temperature difference ΔT [K]

Average temperature difference ΔT [K] Average temperature difference ΔT [K]

Average temperature difference ΔT [K] Average temperature difference ΔT [K]

Heat output Φ [kW] Heat output Φ [kW]

Heat output Φ [kW] Heat output Φ [kW]

Heat output Φ [kW] Heat output Φ [kW]

Page 9: Trench heating - VKN SILENT · 2019-10-01 · Trench Heater Acoustic measures” and report no 5/2017 “VKN5 9/25 In-floor Fan Assisted Trench Heater Acoustic measures” both executed

9 w w w . v e r a n o - g l o b a l . c o m

Heat output corrective factors for VKN 100 mm high heaters for installation temperatures other than 75/65/20°C.

FLOW AND RETURN TEMPERATURES [°C] ROOM AIR TEMPERATURE θI [°C]

ts tr 5 8 12 16 20 24 32

90

85 1,710 1,644 1,555 1,467 1,379 1,292 1,11880 1,655 1,588 1,500 1,412 1,325 1,238 1,06475 1,600 1,533 1,445 1,358 1,270 1,183 1,01170 1,544 1,478 1,390 1,303 1,216 1,129 0,957

85

80 1,600 1,533 1,445 1,358 1,270 1,183 1,01175 1,544 1,478 1,390 1,303 1,216 1,129 0,95770 1,489 1,423 1,336 1,248 1,162 1,075 0,90465 1,434 1,368 1,281 1,194 1,108 1,021 0,851

80

75 1,489 1,423 1,336 1,248 1,162 1,075 0,90470 1,434 1,368 1,281 1,194 1,108 1,021 0,85165 1,379 1,314 1,227 1,140 1,054 0,968 0,79860 1,325 1,259 1,172 1,086 1,000 0,915 0,745

75

70 1,379 1,314 1,227 1,140 1,054 0,968 0,79865 1,325 1,259 1,172 1,086 1,000 0,915 0,74560 1,270 1,205 1,118 1,032 0,947 0,861 0,69355 1,216 1,151 1,064 0,979 0,893 0,808 0,641

70

65 1,270 1,205 1,118 1,032 0,947 0,861 0,69360 1,216 1,151 1,064 0,979 0,893 0,808 0,64155 1,162 1,097 1,011 0,925 0,840 0,756 0,58950 1,108 1,043 0,957 0,872 0,787 0,703 0,537

65

60 1,162 1,097 1,011 0,925 0,840 0,756 0,58955 1,108 1,043 0,957 0,872 0,787 0,703 0,53750 1,054 0,989 0,904 0,819 0,735 0,651 0,48645 1,000 0,936 0,851 0,766 0,682 0,599 0,435

60

55 1,054 0,989 0,904 0,819 0,735 0,651 0,48650 1,000 0,936 0,851 0,766 0,682 0,599 0,43545 0,947 0,883 0,798 0,714 0,630 0,547 0,38540 0,893 0,830 0,745 0,661 0,578 0,496 0,335

55

50 0,947 0,883 0,798 0,714 0,630 0,547 0,38545 0,893 0,830 0,745 0,661 0,578 0,496 0,33540 0,840 0,777 0,693 0,609 0,527 0,445 0,28535 0,787 0,724 0,641 0,558 0,476 0,395 0,236

5045 0,840 0,777 0,693 0,609 0,527 0,445 0,28540 0,787 0,724 0,641 0,558 0,476 0,395 0,23635 0,735 0,672 0,589 0,506 0,425 0,345 0,188

4540 0,735 0,672 0,589 0,506 0,425 0,345 0,18835 0,682 0,620 0,537 0,455 0,375 0,295 0,140

CORRECTIVE FACTORS FOR 100 mm HIGH VKN SILENT HEATERS

GRILLE TYPE AIRFLOW CONVERSION FACTOR

Roll-up aluminium, double t-bar 67% 1,00

Roll-up aluminium, closed profile 61% 0,98

Roll-up wooden grille 52% 0,97

Modular grille 63% 0,99

Linear grille 58% 0,98

Stainless steel grille 62% 0,99

HEAT OUTPUT CORRECTIVE FACTORS FOR VKN SILENT HEATERS ACCORDING TO THE GRILLE TYPE

Page 10: Trench heating - VKN SILENT · 2019-10-01 · Trench Heater Acoustic measures” and report no 5/2017 “VKN5 9/25 In-floor Fan Assisted Trench Heater Acoustic measures” both executed

10 w w w . v e r a n o - g l o b a l . c o m

WATER CAPACITY FOR VKN SILENT HEATERS

HEATER LENGTHLk [mm]

HEATER T YPE

VKN1-10/17/Lk VKN5-10/25/Lk

WATER CAPACIT Y [dm 3]

650 0,18 0,16

1050 0,33 0,28

1450 0,47 0,40

1850 0,64 0,53

2250 0,78 0,64

2650 - 0,76

3100 - 0,89

3500 - 1,01

DECLARED PROPERTIES

0,0110 100 1000

1

0,1

10

100

100 200 5005020 30 300

0,020,03

0,05

0,20,3

0,5

23

5

2030

50

0,1 1 2 30,2 0,3 0,5

1 102 3 50,3 0,5

1 2 3 5 10 200,5

1 102 3 50,50,2 0,3

0,3

0,2

5

15

Lk=650 mm

Lk=1050 mmLk=1450 mmLk=1850 mmLk=2250 mm

0,0110 100 1000

1

0,1

10

100

100 200 5005020 30 300

0,020,03

0,05

0,20,3

0,5

23

5

2030

50

0,1 1 2 30,2 0,3 0,5

1 102 3 50,3 0,5

1 2 3 5 10 200,5

1 102 3 50,50,2 0,3

0,3

0,2

5

15

Lk=650 mm

Lk=1050 mmLk=1450 mm

Lk=3500 mmLk=3100 mm

Lk=1850 mmLk=2250 mmLk=2650 mm

PRESSURE LOSSES

Pres

sure

loss

Δp

[kPa

]

Pres

sure

loss

Δp

[kPa

]

Water flow ṁ [kg/h] Water flow ṁ [kg/h]

Φ [kW] for Δt=5 K Φ [kW] for Δt=5 K

Φ [kW] for Δt=10 K Φ [kW] for Δt=10 K

Φ [kW] for Δt=15 K Φ [kW] for Δt=15 K

Φ [kW] for Δt=20 K Φ [kW] for Δt=20 K

| VKN1-10/17/Lk | VKN5-10/25/Lk

Maximum permissible operating pressure: 1,0 MPa

Test pressure: 1,3 MPa

Maximum hydraulic pressure: 1,69 MPa

Maximum operating temperature: 110°C

Page 11: Trench heating - VKN SILENT · 2019-10-01 · Trench Heater Acoustic measures” and report no 5/2017 “VKN5 9/25 In-floor Fan Assisted Trench Heater Acoustic measures” both executed

11 w w w . v e r a n o - g l o b a l . c o m

THE 230V AC – IP65 RATED CONNECTION SUPPLY MODULE

VKN SILENT ARE NOT ONLY FAN ASSISTED TRENCH HEATERS IN OUR RANGE

For thermomodernized buildings, it becomes problematic to provide additional 24 V DC low voltage installation. To avoid this problem, the power supply and connection module has been developed that allows the 230 V AC power supply to be connected directly to the heater trench. The internal connection box provides correct connection of the all electrical elements of the trench heater, further installation time on site.

The connection kit includes:• 230 V AC / 24 V DC Power supply • VER-927 Connection Box • 230 Electric Box• Heater trench extension of standard unit

The additional information about accessories for VKN SILENT, as well as the selection method, can be found in the VKN fan assisted trench heaters catalogue.

The other VERANO VKN fan assisted trench heaters:

VKN1:

• VKN1-6,5/14/Lk

• VKN1-6,5/17/Lk

• VKN1-9/14/Lk

• VKN1-9/17/Lk

VKN5:

• VKN5-7,5/25/Lk

• VKN5-7,5/35/Lk

• VKN5-9/25/Lk

• VKN5-9/35/Lk

• VKN5-14/30/Lk

• VKN5-18/30/Lk

1 www.v-k.pl

VKNFan assisted trench heaters

2017_09

Page 12: Trench heating - VKN SILENT · 2019-10-01 · Trench Heater Acoustic measures” and report no 5/2017 “VKN5 9/25 In-floor Fan Assisted Trench Heater Acoustic measures” both executed

12 w w w . v e r a n o - g l o b a l . c o m

After publishing edition of this catalogue i.e. 01.08.2019 there might have been changes in products. The manufacturer reserves the right to changes in construction or deviations from the adapted colour range. The illustrations may include optional equipment. Print technology may cause differences in printed colours. For further information please contact VERANO CONVECTOR sales representative.

VERANO

ul. Vetterów 7a, 20-277 Lublintel. +48 81 44 08 330 | tel. +48 515 166 103

w w w .v e r a n o - g l o b a l . c o m

1 www.v-k.pl

PRICE LIST09/2018

1 www.v-k.pl

CVKTrench heating and cooling units

2018_06

1 www.v-k.pl

VKNFan assisted trench heaters

2017_09

1 www.v-k.pl

FRESHAIR+Trench heating and cooling units with fresh air supply

2018

1 www.v-k.pl

COMODO CALIENTE STANDARDWall mounted and Floor mounted convectors

2018_01

1 www.v-k.pl1

VK15Natural convection trench heaters

2018

PRICE LISTCVKTrench heating

and cooling units

VKNFan assisted

trench heaters

FRESHAIR+Trench heating and cooling units

with fresh air supply

COMODO CALIENTE STANDARDWall mounted and floor mounted

convectors

VK5Natural convection