tri chlorine generator instruction manual and … · 1 welcome to zodiac congratulations on your...
TRANSCRIPT
TRi ChloRine GeneRaToR
insTRuCTion Manual and WaRRanTy CaRd
1
Part: Qty: description:
a. 1 TRiPowerpack
b. 1 Chlorinegeneratingcell
c. 1 Powerpackbracket
d. 2 Reducingbushes
This KiT ConTains:
1
WelCoMe To ZodiaC
CongratulationsonyourpurchaseofaproductfromtheZodiacrangeofpoolcareproducts.Zodiacproductsaredesignedtoletyouspendmoretimeenjoyingyourpoolandlessonmaintenance.
iMPoRTanT infoRMaTion
YOUMUSTREADTHISINFORMATIONBEFOREINSTALLATION.ALWAYSREADTHELABELANDOPERATIONMANUALBEFOREUSING.PLEASEKEEPYOURMANUALASITCONTAINSYOURWARRANTY.
2 3
ZodiaC Believes in safeTy fiRsT
AtZodiac,wetakesafetyseriously.Alwaysexercisecautionwhenusingelectricalappliancesandfollowtheinstructions.Failuretodosocouldresultinpermanentinjury,electrocutionordrowning.
GeneRal WaRninGs
Zodiacsaltwaterchlorinegeneratorsaredesignedfordomesticswimmingpooluseonly.Contraryusecouldaffectperformanceandvoidwarranty.
Operatingachlorinegeneratorwithoutwaterflowingthroughthecellmaycauseabuildupofflammablegases,resultinginfireorexplosion.
Keepequipmentoutofreachofchildren.
Adamagedsupplycordshouldonlybereplacedbythemanufacturer,authorizedserviceagentorelectrician.
Wheninstallingandusingthiselectricalequipment,alwaysfollowbasicsafetyprecautions.
Beforeperforminginstallation,disconnectallpower.
Forswimmingpools,Australianstandardsrecommendaminimumof1PartPerMillion(ppm)offreeavailablechlorinemustbemaintainedatalltimes.
ServicetoZodiacequipmentshouldonlybecarriedoutbyqualifiedandauthorizedpoolprofessionals.
2 3
ZodiaC Believes in safeTy fiRsT
Child safeTy
Childrenshouldnotbeallowedtooperateorperformmaintenanceonthisproduct.
Noone,particularlychildren,shouldsit,step,lean,orclimbonanyofyourpool’soperationalsystem.
Intheinterestsofchildsafety,allcomponentsofapool’soperationalsystemshouldbelocatedatleast3.5metresawayfromthepool.
eleCTRiCal haZaRd
Toavoidaccidentalcontactwithlawnmowersandhedgetrimmers,powercordsshouldremainwithinsightandabovegroundatalltimes.
TheZodiacTRIPowerpackmustnotcomeintocontactwithwaterandmustbeinstalledatleast3.5metresfromtheinsidewallofyourswimmingpool.
Shouldalackofwaterbedetected,theunit’selectronicflowswitchisdesignedtoturnoffthesystem.Interferingwiththeelectronicflowswitchcouldresultinpersonalinjuryand/ordamagetothecell.
Onepumpperelectricalsocketonly(noancillaryequipmentshouldbeconnectedtothesameoutlet).
Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebyapersonresponsiblefortheirsafety.
Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.
TheinstallationofthechlorinatorshouldbecarriedoutbyaqualifiedpersoninaccordancewiththeAustralianwiringrulesAS/NZS3000.
Thechlorinatorpowerpackshouldbelocatedinthecorrectpoolzoneandconnectedtosupplyviaapoweroutletthatisprotectedbyaresidualcurrentdevice(RCD)havingaratedresidualoperatingcurrentnotexceeding30mA.ThepoweroutletshouldhaveadegreeofprotectionsuitableforthepoolzoneEnsurethatequipotentialbondingofallpartsofthepoolinstallationiscarriedout.
4 5
insTallaTion Guide
ThefollowingstepswillhelpyougetupandrunningwithyournewZodiacTRiChlorinegenerator.
PosiTioninG The PoWeR PaCK
1. Locateasuitablespaceforthepowerpackbracket.Itshouldbeinstallednofurtherthan1.8metresawayfromthecell-ideallyinafiltrationshedorclosetothefiltrationequipment.
PLEASENOTE:iffixingtoapostitmusthaveawaterproofpanelfitted(behindtheunit),atleast450mmwideand470mmhigh.
2. Usingscrewsprovided,fastenthebracketsecurelytothewallandpositionthepowerpackonthebracket.Plugintopowerpoint,butdon’tturnonthepower.
PosiTioninG The ChloRine GeneRaTinG Cell
PLEASENOTE:Thecellshouldalwaysbethelastdeviceplacedonthewaterpipe(Inthereturnlinetothepool).
3. Ensurethecellisplacedhorizontally,withtheInletpipeconnectingtothefittingclosesttothecelllead.
4. Usingscrewbarrelfittings(supplied),attachthecelltothepipe.Ifusing40mmpipe,youwillneedtofitthecellusingthereducingbushes(alsosupplied).
5. Whenconnectingtheleadfromthepowerpacktothecellmatchupthecorrespondingcoloursandpins,thenfittheendcap.
(Note:EitherREDwirecanbeconnectedtoeitherREDpinontheelectrode.)
6. PlugyourpoolpumpintotheoutletsocketinthebottomoftheTRi(thiswillallowtheTRitimertocontrolthefiltrationtimes)
7. OnceallconnectionsaretogetherpressthemainspowerswitchtoON.
4 5
naviGaTion BuTTons
UsethefollowingUIbuttonstoaccessandselectallmenusandcommands:
on/off
TurnUIpoweron/off.
uP/doWn
Scrollup/downwithincurrentmenutohighlightaspecificmenucommand.
Menu/BaCK
Entersintothemainmenu,andusedtogobacktopreviousmenu.
seleCT/enTeR
Select/enterscurrenthighlightedmenucommand.Displaythenextrelatedcommandoractivatetheselectedfunction
6 7
usinG inBuilT CloCK and TiMeRs
Whenitcomestochlorination,everypoolisdifferent.Togetwhat’srightforyou,youwillneedtosettheunit’sclockandtimers.
seTTinG The CloCK
1. Switchpoweron.
2. Waitforthestart-upsequencetocomplete.
3. Pressthe buttontoentertheMAINMENU.
4. Use / buttonsandscrolltoSETCLOCK.
5. Press .
6. Use / buttonstosetthehours.
7. Press tosavethehours.
8. Usethe / buttonstosettheminutes.
9. Press tosavetheminutes.
TRiwillthenreturntotheMAINMENU.
10.Press toreturntotheoperatingscreen.
NOTE:Thetimeisdisplayedin24Hourformat
6 7
TuRninG ChloRine GeneRaTion on
ThechlorinegenerationoftheTRicanbecontrolledinanumberofways:
1. Manuallysettoanoutputlevel,withtheoperatingtimesdeterminedbyanexternaltimer.
2. Usingthein-builttimersontheTRiunit(referto‘TheTimers’)
3. Usingaconnectiontoanexternalcontroller(referto‘Connectingtoacontroller’).
Toturnthechlorinegenerationonmanually,presstheON/OFFbutton.Theoutputlevelcanbesetasdescribedin‘SettingtheChlorineOutput.’NOTE:Forsafetyreasons,theTRichlorinegeneratorwillcontinuallydosechlorineforamaximumof30hoursifleftrunningwithno‘OFF’time–unlessconnectedtoenexternalcontroller.Afterthistime
theTRiwillswitchto‘OFF’.
The TiMeRs
TheZodiacTRichlorinegeneratorcomeswithtwoinbuilttimersthatswitchthefiltrationandchlorinationsystemonandoffasrequired.
Duringswimmingseason,considerrunningthesystemforaround8hoursaday.Thiscanbeincreasedto10hoursduringperiodsofveryhotweather.
Inwinter,itmayonlybenecessarytorunyourpool’sfiltrationsystemfor4hoursaday.Theseshorterperiodsofactivitywilllengthenthelifeoftheunit’selectrode.
Forbestyearroundresults,settheunittooperateduringthecoolerhoursoftheearlymorning,eveningorwhenswimmersareusingthepool.
PRoGRaMMinG The TiMeRs
Toactivatethetimer,youwillneedtoenterbothanONandOFFtime.IfnoOFFtimeisentered,thechlorinegeneratorwillswitchoffatthedefaulttimeof12:00am(0:00).
Youwillknowthatavalidtimehasbeenenteredwhena“T”SymbolisdisplayedinthetoprighthandcorneroftheLCDdisplaywhentheunitisdisplayingthe‘operatingscreen’.
usinG inBuilT CloCK and TiMeRs
8 9
usinG inBuilT CloCK and TiMeRs
Toprogramthetimer:
1. Pressthe button.
2. Press buttontomovearrowto‘SETTIMERS’.
3. Press toenterthe‘SETTIMERS’menu.
4. Press / toselectthetimeryouwishtoset.(Timer1orTimer2)
5. Press .
6. Press / tosetthehours(ontime).
7. Press tosavethehours.
8. Press / tosettheminutes(ontime).
9. Press tosavetheminutes.
10.Press / tosetthehours(offtime).
11.Press tosavethehours.
12.Press / tosettheminutes(offtime).
13.Press tosavetheminutes.
TRiwillreturntothe‘SETTIMERS’menu.
8 9
CleaRinG The TiMeRs
Toclearthetimer:
1. Pressthe button.
2. Press / buttontoscrollto‘SETTIMERS’.
3. Press toenterthe‘SETTIMERS’menu.
4. Press / toscrollto‘CLEARTIMERS’.
5. Press .
Aconfirmationmessagewillappearonthescreen.
exTeRnal TiMe CloCK
Attimes,itmaybedesirabletocontrolchlorinegenerationusinganexternaltimeswitch.IfthechlorinegeneratoristurnedON,andtheexternaltimerfailstoswitchthemainspoweroffwithin30hours,theZodiacTRiwillautomaticallystopchlorinatinginordertopreventoverchlorination.
Tosetthechlorinegeneratortorunfromanexternalclock:
1. CleartheTimerbyfollowingtheprocedureoutlinedin‘ClearingtheTimers’.
2. Pressthe buttontoturnthechlorinegeneratoron.
usinG inBuilT CloCK and TiMeRs
10 11
seTTinG The ChloRine ouTPuT
Theamountofchlorinerequiredbyyourpoolisdependentonanumberoffactorsincludingthesizeofthepool,thenumberofusersandtheclimate.
Outputwillappearasapercentageonthescreenreadout,monitorthelevelaccordingtothereadingovertimewillhelpensureoptimumoutput.
ForuserswhoupgradetotheTRi-PROmodel,chlorineoutputwillbecontrolledautomatically.
TosetChlorineOutputlevels:
1. Pressthe buttontoturnthechlorinegeneratoron.
2. Pressthe / buttonstosetthedesiredoutputlevel.
PLEASENOTE:ifusingapoolcoveryouwillneedtoreducethechlorineproductionsubstantially,pleaseuseLOWmodeifyouuseacover.SimplypressLOWbutton.
ChloRine ouTPuT levels
10 11
CoRReCT seTTinGs foR youR TRi ConTRolled Pool
fre
e
Ch
lori
ne
(p
pm
)
ph
To
tal
alk
alin
ity
(pp
m)
Cal
ciu
m
hard
ne
ss
(pp
m)
Cyan
uri
c a
cid
(p
pm
)
sal
t l
eve
l (p
pm
) s
en
sors
au
stra
lian
sta
nd
ard
1–3
7.2–7.8
80–300
90–300
30–50
4000-7000
ide
al r
ead
ing/
ran
ge
1–3
7.5
80–140
90–300
504000ppm
at27ºC**
To
in
cre
ase
*
Add
chlorine
orincrease
outputof
equipm
ent
Addbuffer
orsodaash
(sodium
carbonate)
Add
sodium
bicarbonate
Add
calcium
chloride
Add
Cyanuric
acid
AddSalt
To
de
cre
ase
*
Add
muriatic
acid
Add
muriatic
acidor
dryacid
Partially
drain
&refillpool
Partially
drain
&refillpool
Partially
drain
&refillpool
fre
qu
en
cy o
f te
stin
g (i
n p
eak
se
aso
n)
Weekly
Weekly
Weekly
Weekly
Weekly
Monthly
Quarterly
Co
RR
eC
T s
eT
Tin
Gs
fo
R y
ou
R T
Ri
Co
nT
Ro
ll
ed
Po
ol
12 13
IfyouuseanautomationorcontrollersystemtocontrolyourpoolyouwillneedtoconfigureyourTRiChlorinegeneratortoallow“communication”betweenthetwo.
you must set the controller type on the TRi before making the wiring connection.
seTTinG The ConTRolleR (To be done before making a wiring connection)
1. SwitchpowertotheTRiuniton.
2. Waitforthestart-upsequencetocomplete.
3. Pressthe button.
4. Pressthe buttontoscrolldownto‘CONTROLLER’.
5. Press toenterthecontrollermenu.
6. Press / tohighlightthecontrollerbeingused.
7. Press tosavethecontrollersetting.
8. TRiwillreturntothemainmenu.
9. Press toreturntotheoperatingscreen.
ConneCTinG To a ConTRolleR
12 13
aTTenTion Jandy ‘Rev l’ oR laTeR useRs
ItiscriticalthatthecontrollersettingbesettothecorrectZodiac,JandyorPentaircontrollerdesignation.ThereareanumberofdifferentrevisionslockedintotheTRisoftware.Pleaseseetheusermanualtodeterminethemodeland/orrevisionyouareusing.Iftheincorrectsettingisselected,damagecanbecausedtotheJandyAqualinkControlUnit.
CauTion When WiRinG To a ConTRolleR
IMPORTANT
Wiringofthecontrollershouldbecompletedbyanauthorisedpoolequipmentinstaller.
Beforeanywiringconnections/disconnectionsensuremainspowerisremovedfromboththecontrollerandtheZodiacTRiunit.
Whenconnectedtoacontroller,theTRiChlorinegeneratoractsasthe‘slave’-respondingtorequests.Thismeanstimersettingsareignoredandtheoutputsettingscannotbechanged,althoughallother‘menu’functionsarestillaccessible,exceptforLOWandBOOSTmodes.
WiRinG To a ConTRolleR
ThefollowinginstructionsshouldbereadinconjunctionwiththeinstallationguideprovidedwiththeController.
1. Removesilver‘dress’coverbypressinginatthesideswhereindicatedbelowandlift.
2. Removethetwoscrewswhichattachthelowercovertothemainunit:
ConneCTinG To a ConTRolleR
14 15
ConneCTinG To a ConTRolleR
3. RemovethelowercoverfromtheTRiunit.NOTE:IfusingeitherpHupgradeorPROunit–carefullydisconnecttheribboncablefromtheTRiunit.
4. RemovethesmallwhitebungclosesttothecentreofthelowerpaneloftheTRiunit.
5. Threadthecontrollercablethroughthehole(agrommetmaybenecessarydependingonthesizeofthecablebeingused).
6. Attachacabletietothecontrollercableasshowninthediagram.Thewiringcolourcodesareoutlinedbelow:
DependingonthemakeoftheController,makethefollowingwiringconnections:
Polaris eos / Jandy / Zodiac aqualink / aqualink TRi
Greenwire(0V)to‘0V’terminalontheTRi
Redwiretothe(+V)‘POS’terminalontheTRi
Yellow/White(B)wireto‘B’terminalonTRi
Blackwire(A)to‘A’terminalonTRi
Pentair intellitouch
GREENwireto‘B’terminalonTRi
Redwireto‘POS’terminalonTRi
Yellowwireto‘A’terminalonTRi
Blackwireto‘0V’terminalonTRi
14 15
TesTinG The WiRinG ConneCTion
OnceaconnectionhasbeenmadebetweentheControllerandtheChlorinegenerator,itwillneedtobetested.
1. TurnonthepowertotheControllerandtheZodiacTRi.
2. Ifsuccessful,a‘ ’symbolwillappearinthetoprighthandcornerofthescreenafterabout20seconds.
3. Ifthecontrollerdoesnotconnect,turnpowerofftoboththedevicesandtryagain.
veRify The WiRinG ConneCTions
Toverifytheconnection:
1. SwitchtheTRiunitonandcheckthecontrollersetting(followinstructionsunder‘SETTINGCONTROLLER’.
2. Re-testtheconnection. Note:Forsafetyreasons,theZodiacTRirevertstotheOFFsettingifthecommunication
connectionislost.
ConneCTion To ConTRolleR foR Pool/sPa CoMBinaTions
ToconnectaZodiacTRiunittoPoolorSpaValves,youwillneedtomakea“splice”intothecontrollinesfromtheController,locatedinsidethecontrolleritself.
Forfurtherinformation,consulttheinstallationmanualoftheControllerbeingused.
ConneCTinG To a ConTRolleR
16 17
Ifyourpoolhasacover,youshouldsettheoutputlevelto“low”.Thisisalsoknownas“winter”mode.
Reducingyourchlorineoutputwillhelppreventdamagetoyourpool’scoverandotherequipment.
Manual seTTinG
1. ToselectLowmodepress .
Thiswilldropthechlorineoutputtoaround10%.
2. ‘Low’willappearonthescreen. Note:LoworWintermodecannotbeselectedwhenTRiisbeing
controlledbyanexternalcontroller.
auToMaTiC seTTinG
TheZodiacTRicanbeconnectedtothevalvesofanautomaticpool/spasystem.
Whentheinputfromthevalvesissetto‘Low’theTRiwillautomaticallyrevertto‘Low’modeandtheoutputwillbelockedat10%
Detailsofthewiringconnectionareoutlinedinthe‘‘ConnectiontoAutomaticPool/SpaValve”sectionofthismanual.
for users who have upgraded to the TRi-ph or TRi-PRo, the automatic ph/aCl control function is disabled when in loW mode.
seTTinG The Mode To loW: Important If usIng a pool cover
16 17
Attimesyourpoolmayrequirealargerthannormalapplicationofchlorine.TheBoostfunctionisusedtorapidlyaddchlorine.
InBOOSTor“Superchlorinate”mode,outputsettingsaretemporarilyoverriddenandthechlorinegeneratorrunsfor24hoursat100%ChlorineProduction.
In‘TIMER’mode,thecirculationpumpwillrunfor24hours,beforeautomaticallyrevertingtopreviousoutput/timersettings.
In‘MANUAL’mode,thechlorinegeneratorwillrunat100%foracumulativetotalof24hoursbeforerevertingtothepreviousoutputsetting.
NOTE:
The‘BOOST’modecannotbeengagedunderthefollowingcurcumstances:
1) IftheTRiisinthe‘OFF’operatingmode.Thechlorinatormustbe‘ON’forBOOSTtobeengaged.
2) IfyouhaveupgradedtotheTRi-PRO
3) OrfromthefrontpanelwhentheTRiisbeingcontrolledbyanexternalcontroller.
InmostcasesaBOOSTfunctioncanbesetfromthecontrollermenu.
Consultyourthirdpartycontrollermanualformoreinformation.
seTTinG The BoosT Mode
ToactivatetheBOOSTsetting:
Pressthe button.
‘BOOST’willbedisplayedonthescreenandchlorinegenerationwillcommence.
The BoosT seTTinG
18 19
TheZodiacTRichlorinegeneratorautomaticallyprovidesanumberofinbuiltwarningsthatcanhelpidentifyproblemsandoffersolutions.
ToaccesstheHELPmenu:
1. Pressthe button.
2. Usingthe / buttons,scrolltothe‘HELP/DIAG’menu.
3. Press toenterthe‘HELP/DIAG’menu.
4. Onceinthe‘HELP/DIAG’menu,usethe / buttonstoscrollto
theerror/warningthathasbeendisplayed.
5. Press .
Anumberofsuggestedsolutionsaremomentarilydisplayed,inorderofpriority.
Afterdisplaying,theTRiautomaticallyrevertsbacktothe‘HELP/DIAG’menu.
6. Toexittothedefaultoperatingscreenwait~5seconds
ORpressthe button.
helP and TRouBleshooTinG
18 19
TokeepyourTRiUnitinthebestpossibleconditionitisrecommendedregularmaintenanceshouldbeperformed.
insPeCTinG and CleaninG The eleCTRode
InareasthatexperiencecalciumhardnesstheTRielectrodewillbenefitfromcleaning.
Tocleanyourelectrode:
1. Switchoffthefilterpumpandchlorinegenerator,closenecessaryvalvesandunplugthecellterminalcap.
2. Unscrewtheretainingringandremovetheelectrode.Ifcalciumbuildupispresent,immersetheelectrodeincellcleaningsolutionwithoutimmersingtheterminals.
3. WerecommendusingZodiacSaltChlorinatorCellCleanertocleantheelectrode.Howeveryoucanmixyourownbycarefullyaddingone(1)partofHydrochloric(Muriatic)acidtoten(10)partswater.Strongersolutionswillshortenterminallife.
4. Allowthecleaningsolutiontodissolvethecalciumdepositsforabout10minutes.DisposeofthecleaningsolutionatanapprovedCouncilDepotandneverintostormwaterorsewagedrains.
6. Rinsetheelectrodeincleanwaterandre-fittheelectrodeinthecellhousing.
7. Replacethecellheadandplugassemblyandresetvalvesandswitches.TurnpumpandTRion.
8. Confirmchlorineoutputandsettingsonthepowerpack.Timersettingswillbeautomaticallyretained.
MainTenanCe
20 21
eRRoRs and WaRninGs. WhaT They Mean.
no floW
Diagnosis:Insufficientwaterflowinthecell.Thiscouldmeanthecirculationpumphasceasedtofunction,orthefilterneedscleaning.Thechlorineoutputwillbeturnedoffatthistime.
CheCK salT
Diagnosis:Saltlevelisbetween3000and4000ppm,dependingonthewatertemperature.
Alwaysmaintainasaltlevelabove4000ppm.ifyoudon’tknowwhatyoursaltlevelisorhowtotestit,consultyourlocalpoolcareprofessional.
CheCK PoWeR suPPly
Diagnosis:Therecouldbeaproblemwiththepowersupply.Turnpoweroffatthepowerpointandconsultyourlocalpoolcareprofessional.
CleaninG
Diagnosis:Thecellisintheprocessofreversingpolarity.Waitapproximately5minutesandchlorineproductionshouldresumeasnormal.
20 21
TRouBleshooTinG
additional information about this product can be found at zodiac.com.au
Forfurtherinformationandassistancepleaseconsultyourlocalpoolprofessional.
Your Local Dealer:
22 23
express Warranty*ZodiacGroupAustralia Pty Ltd (Zodiac australia)warrants that theZodiacTRiSaltwaterChlorineGeneratorwillbefreefromdefectsinmaterialsandworkmanshipfortheperiodof3yearsfromthedateofpurchase.
* The warranty applicable to commercial application is limited to 12 months from the date of installation.
Conditions
1 Thisexpresswarrantyonly applies if theProducthasbeenpurchasedfromadealerauthorisedbyZodiacAustraliatosupplyit(authorised dealer).
PurchasefromanAuthorisedDealerensuresthattheproductisagenuineZodiacproduct,thatitistheversiondesignedforAsiaPacificconditions,and that thePurchaserhasaccess toappropriate technicalknowledgeandadvice.
2 ZodiacAustralia’s liabilityunder thisexpresswarranty is limited, at itsoption,totherepairorreplacementoftheProductorthepaymentofthecostofhavingtheProductrepairedorreplaced.
3 Thisexpresswarrantydoesnotapplyinthefollowingcircumstances:
(a)if the Product has not been installed in accordancewithZodiac’sinstallationinstructions;
(b)iftheProducthasbeenmodifiedotherthanasauthorisedbyZodiacAustraliaorifacomponentparthasbeenreplacedbyapartthatisnotagenuineZodiacproduct;
(c)if a defect results fromuse of the Product outside recommendedoperatingconditions;or
(d)if a defect results from damage (including damage to any internalelectronics)causedbyapowersurgeorlightningstrike.
Zodiac chlorinators are designed and tested in accordance withInternational Standard EN 61000-6-1 immunitymeasurements. Theyaredesignedtotolerateminorfluctuations(2000volts)inpowersupplythatcanbereasonablyexpectedtooccurintheenergygrid.Theywillnottoleratepowersurgesoutsidetheselimitsnorwilltheywithstandlightningstrikes.
ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees
22 23
ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees
4 Withoutlimiting3above,productssoldbyZodiacAustraliaaredesignedforusewithswimmingpoolwaterbalancedinaccordancewithAustralianStandardAS3633-1989withapHrangeof7.0-7.8.Maximumchlorinereadingsshouldnotexceed4ppm.Wherepoolwaterisnotmaintainedwithintheseparameters,ZodiacAustraliawillnotberesponsibleunderthisexpresswarrantyforanyresultingdamage,includingdamagecausedbycorrosion,scalingorstressloading.
5 Replacementpartssuppliedunderthisexpresswarrantyarewarrantedtobefreefromdefectsinmaterialsandworkmanshipfortheremainderofthewarrantyperiodorfor12monthsfromthesupplyofthereplacement,whicheverislonger.
6 WarrantyclaimsrelatingtoreplacementoftheelectrodesforLMseries,Cseries,DuoClearandDserieschlorinatorsaresubjecttothefollowingpro-ratapricingprocedure.ThePurchasermustpayforthereplacementelectrodeaproportionofthecostequaltothatproportionofthewarrantyperiod duringwhich theoriginal electrode functioned effectively. Thewarrantyperiodforthereplacementelectrodeistheremainderofthewarrantyperiodfortheoriginalelectrodeor12monthsfromthesupplyofthereplacement,whicheverislonger.ThePurchasermustpayfullcostforanyreplacementelectrodesafterthefirstreplacement.
Product warranty registration
7 PurchasersshouldregistertheirProductsassoonasconvenientlypossibleafterpurchasebycompletingaProductWarrantyRegistrationFormandpostingittoZodiacAustraliaattheaddressshownontheFormorbyregisteringonlineatwww.zodiac.com.au.
8 Productregistrationmustoccur,andproofofpurchasemustbereceivedbyZodiacAustralia,priortoanywarrantyworkbeingapproved.Whereapplicable,aserialnumber,installationdateandnameofinstallerisrequiredaspartoftheregistrationprocess.
24 25
ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees
how to make a warranty claim
9 ThePurchasermusttelephoneoremailZodiacAustraliaCustomerServiceandobtainawarrantyIDnumberforthewarrantyclaim.
Contactdetailsare:
Zodiac Group australia Pty ltd 219WoodparkRoadSmithfieldNSW2164
Customer service Telephone:1800688552Emailaddress:[email protected]
10ZodiacAustralia reserves the right to determine, in relation to eachwarrantyclaim,whethertheProductshouldbereturnedtotheAuthorisedDealerat theaddresswhere thePurchaserpurchased theProductorwhetherwarrantyservicewillbeprovidedinthefield,repairedataZodiacworkshoporatthepremisesofanauthorizedZodiacwarrantyagent.
11 IfitisnecessaryforthePurchasertoincurfreightchargesinmakingavalidclaimunderthiswarranty,ZodiacAustraliawillreimbursethePurchaserforchargesreasonablyincurreduponproofofthecharges.
24 25
ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees
additional guarantees, rights and remediesaustralian Purchasers - Guarantees under the australian Consumer law
12Thebenefitsofthisexpresswarrantyareinadditiontootherguarantees,rights and remediesAustralian consumers have under theAustralianConsumerLaw.
13ZodiacAustraliaproductscomewithguaranteesthatcannotbeexcludedundertheAustralianConsumerLaw.Youareentitledtoareplacementorrefundforamajorfailureandforcompensationforanyotherreasonablyforeseeablelossordamage.Youarealsoentitledtohavethegoodsrepairedorreplacedifthegoodsfailtobeofacceptablequalityandthefailuredoesnotamounttoamajorfailure.
Purchasers in other Countries
14ThelawsandregulationsofothercountriesmayconferonPurchasersinthosecountriesadditionalrightsandremedies.Totheextentthattheycannotbeexcludedormodified,Purchasershavethebenefitsofthoserightsandremediesinadditiontothebenefitsofthisexpresswarranty.Tothefullextentthatitispermissibletodoso,thoseadditionalrightsandremediesareexcludedormodifiedsoastobeconsistentwithZodiacAustralia’sexpresswarranty.
inConsisTenCy WiTh WaRRanTy sTaTeMenTs in PRoduCT Manuals oR oTheR doCuMenTs aCCoMPanyinG PRoduCTs
Ifanywarrantystatements inaZodiacAustraliaproductmanualorotherdocumentareinconsistentwiththeaboveExpressWarrantyandGuarantees,theaboveoverridesandreplacestheinconsistentstatements.
ZodiacisaregisteredtrademarkofZodiacGroupAustraliaPtyLtdABN87002641965
ZodiaC CusToMeR seRviCe CenTRe
ZodiacGroupAustralia:
219WoodparkRd,Smithfield,NSW2164Australia
Tel:1800688552Fax:1300781688
Email:[email protected]
Duetoconstantdevelopmentsandimprovements,specificationsmaychangewithoutnotice.
Improperusecouldaffectperformanceandvoidwarranty.
©CopyrightZodiacAustraliaLtd2013
W176781REV.A
pH Upgrade
InstrUctIon ManUal and
Warranty card
1
part: Qty: description:
1. 1 TRi-pHModule(ifpurchasedseparately)2. 1 Holesaw3. 1 Tubing4. 1 PODassembly5. 1 pHsensor6. 1 pHsensorcable7. 1 Sensorcalibrationfluid8. 1 AntiFumeCap5ltand15/20lt9. 1 CeramicWeight10. 1 Weightbarbfitting(forendoftube)
WelcoMe to ZodIactHIs KIt contaIns:
9. 10.
1.
4. 5.
6.
7.
8.
2.
3.
1
WelcoMe to ZodIactHIs KIt contaIns:
CongratulationsonyourpurchaseofaproductfromtheZodiacrangeofpoolcareproducts.Zodiacproductsaredesignedtoletyouspendmoretimeenjoyingyourpoolandlessonmaintenance.
IMportant InforMatIon
YOUMUSTREADTHISINFORMATIONBEFOREINSTALLATION.ALWAYSREADTHELABELANDOPERATIONMANUALBEFOREUSING.PLEASEKEEPYOURMANUALASITCONTAINSYOURWARRANTY
AtZodiac,wetakesafetyseriously.Alwaysexercisecautionwhenusingelectricalappliancesandfollowtheinstructions.Failuretodosocouldresultinpermanentinjury,electrocutionordrowning.
general WarnIngs
Zodiacsaltwaterchlorinegeneratorsaredesignedfordomesticswimmingpooluseonly.Contraryusecouldaffectperformanceandvoidwarranty.
Operatingachlorinegeneratorwithoutwaterflowingthroughthecellmaycauseabuildupofflammablegases,resultinginfireorexplosion.
Keepequipmentoutofreachofchildren.
Adamagedsupplycordshouldonlybereplacedbythemanufacturer,authorizedserviceagentorelectrician.
Wheninstallingandusingthiselectricalequipment,alwaysfollowbasicsafetyprecautions.
Beforeperforminginstallation,disconnectallpower.
Forswimmingpools,Australianstandardsrecommendaminimumof1Part
PerMillion(ppm)offreeavailablechlorinemustbemaintainedatalltimes.
ServicetoZodiacequipmentshouldonlybecarriedoutbyqualifiedandauthorizedpoolprofessionals.
2 3
ZodIac BelIeves In safety fIrst IMportant tHIngs to reMeMBer
cHIld safety
Childrenshouldnotbeallowedtooperateorperformmaintenanceonthisproduct.
Noone,particularlychildren,shouldsit,step,lean,orclimbonanyofyourpool’soperationalsystem.
Intheinterestsofchildsafety,allcomponentsofapool’soperationalsystemshouldbelocatedatleast3.5metresawayfromthepool.
electrIcal HaZard
Toavoidaccidentalcontactwithlawnmowersandhedgetrimmers,powercordsshouldremainwithinsightandabovegroundatalltimes.
TheZodiacTRiPowerpackmustnotcomeintocontactwithwaterandmustbeinstalledatleast3.5metresfromtheinsidewallofyourswimmingpool.
Shouldalackofwaterbedetected,theunit’selectronicflowswitchisdesignedtoturnoffthesystem.Interferingwiththeelectronicflowswitchcouldresultinpersonalinjuryand/ordamagetothecell.
Onepumpperelectricalsocketonly(noancillaryequipmentshouldbeconnectedtothesameoutlet).
Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebyapersonresponsiblefortheirsafety.
Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.
TheinstallationofthechlorinatorshouldbecarriedoutbyaqualifiedpersoninaccordancewiththeAustralianwiringrulesAS/NZS3000.
Thechlorinatorpowerpackshouldbelocatedinthecorrectpoolzoneandconnectedtosupplyviaapoweroutletthatisprotectedbyaresidualcurrentdevice(RCD)havingaratedresidualoperatingcurrentnotexceeding30mA.ThepoweroutletshouldhaveadegreeofprotectionsuitableforthepoolzoneEnsurethatequipotentialbondingofallpartsofthepoolinstallationiscarriedout.
2 3
ZodIac BelIeves In safety fIrst IMportant tHIngs to reMeMBer
ThereareanumberofveryimportantthingstorememberwhensettingupandmaintainyourTRi-pH.
1. ItisabsolutelyessentialtohavethepoolwateringoodbalancebeforeturningtheTRi-pHonsoensurethatthepoolwateriscorrectlybalanced(seepage10oftheTRiownersmanualforcompletelist).
2. DoNOTunderanycircumstancesstoretheacidcontainerunderneaththepowerpackunit.RisingacidfumeswillcauseconsiderabledamagetotheunitandthiswillNOTbecoveredunderwarranty
3. Storeyouracidcontainersafelyandoutofreachofchildren.Iftheacidcontainerisstoredinashedalwaysensurethereisadequateventilationforfumestoescape
4. DoNOTdilutethepoolacid.TRiisahighperformance,highdurabilityproductandisdesignedtousestraightacidfromthecontainer,soyoudonothavetodiluteit.
5. Alwayshandlethesensorswithcareandnevertouchthesensortipwithyourfingers.Ifthesensorneedscleaningusesoapandwaterandcleanthoroughly
6. IfinstallingTRi-pHonanewpoolyoumayfindthatahigherthanusualaciddemandisexpected.Thiswillsettleafterafewweekssopleasemonitoritsneedsduringthis‘settling’phase
4 5
InstallIng tHe pH sensor pod
ThefollowingstepswillhelpyougetupandrunningwithyournewZodiacTRipHUpgradeModule.IfyoupurchaseyourZodiacTRipHasacompleteunitgostraighttosection-InstallingSensors.
If yoU Have pUrcHased tHe trI pH Upgrade:
HowtoinstalltheTRipHupgradeunit:
1. Turnmainspoweroffandremovetheexistingtopcover.
2. Unscrewthebottom2screwsonthemainbodypanelandremovethebottomcover.
3. PlugtheribboncablefromthepHunitintothepHconnectorontheTRiunit.
4. Refitthe2removedscrewsaswellasthetopcoverwiththenewpHunitinstalled.
QUIcK start InstallatIon gUIde
4 5
InstallIng tHe pH sensor pod
Installing the pod and sensorTRisensorPODintegratesintoasimpleunit,apHsensorandapHcorrectivesolutiononewayvalve.ThesensorPODmustbepositionedafterfiltrationsystemandbeforeTRicell(andafteranyheatingsystem).SensorPODmustalwaysbepositionedontoahorizontalpipesothatthepHsensorisvertical(45°maximumtolerance).Warning: never store the acid container underneath or near the tri-pH power pack
QUIcK start InstallatIon gUIde
6 7
preparIng pH sensor fIttIng tHe acId delIvery systeM
1. Identifyastraightsectionofhorizontalpipeofappropriatelengthafterthefilterbutbeforethesaltcell(30cmisrecommended).
2. DisassemblesensorPODtogetlowerpartofPODclampwith2holes(picture1).
3. PlacethelowerpartofPODclampupsidedownintopositionontheselectedlengthofpiping
4. Nowmarkthelocationofthe2holestobemadeintopipingusingapencilormarker(picture2).
5. Drillthe2holesusingtheprovidedholesaw.Ensurethatholesareperfectlysmootharoundtheedges(picture3).
6. PositiontheupperpartofPODclampbyslidingitintothe2previouslydrilledholes(picture4).
Warning: arrows on upper part of pod clamp indicate direction of water flow
7. InterlockthelowerpartofPODclampontotheupperpartalreadyinplaceonpiping.(ifusing40mmpipeusethespacerprovided)
8. FitthePODcapontopofupperPODclamp,re-fitlockingringandtightenfirmlyusingprovidedtool.
9. InstallthepHsensorbyfirmlyscrewingintothePODcap.
10.ConnectthesensorswiththeprovidedcabletotheappropriatesocketsontheTRipowerpack.
2
1
Ensureflowarrowsareinthecorrect
4
3
Smoothedges
SensorfittedinPOD
Injectiontubefittedtoonewayvalve
6 7
preparIng pH sensor
2. Removethesmallfacepanelthatcoverstheperistalticpump
3. Thesuctiontubeisconnectedtothelefthandsideoftheperistalticpump.
4. Usealengthoftubelongenoughtoreachfromtheliquidcontainertothecontrolboxandfeedthetubethroughtheblackrubbergrommetinthe‘anti-fume’cap(2sizesareincluded5ltand15/20lt).
5. Oncethecapisonthetube,nowfitthesmallceramicweightonthesuctiontubeandthenfitthesmallbluebarbfittingtotheendofthetubetopreventtheweightfromfallingoff.(seepictureA)
6. Nowconnecttheinjectiontubingtotheinjectionside(righthand)oftheperistalticpump
7. FirstlyremovethesmallscrewfittingandslideitontothetubingthenfittheendofthetubeontotheonewayvalvelocatedinthesensorPODandscrewdownthefittinglockingitintoposition(thisistheinjectionpointforthesolutionbeingdelivered)(seepictureB)
fIttIng tHe acId delIvery systeM
now the pod is in place and the sensor is connected it is time to connect the suction and injection tubes
1. Toconnectthesuctionandinjectiontubesplease‘soften’theendsofthetubingbyimmersinginwarmwaterforafewminutes.
A
B
8 9
fIttIng tHe acId delIvery systeM testIng / prIMIng tHe acId pUMp
8. Onceallconnectionsaremadeplacethesuctionlineintothecontainerandscrewtheantifumecapdownintoposition.(seepictureC)
please taKe note of tHese IMportant poInts WHen connectIng pH control
• only use straight hydrochloric (muriatic) acid, do not dilute or use any other type of acid.
• do not store the acid container in the filtration shed unless there is adequate ventilation as the fumes will corrode any items in the shed - including your pool care equipment. store your acid in a secure location away from any hazards
• do not store the acid container directly under or near the tri power pack.
failing to comply with this could void your warranty.
C
8 9
Afterinstallationit’srecommendedtheacidpumpbetestedandtheacidpump‘primed’.
WARNING!Beforetestingthepump,ensureallacidsupplyanddeliveryconnectionsaresecure.Alwaysuseappropriatesafetyequipmentwhenhandlingacid.
TotesttheAcidPump:
1. Pressthe button.
2. Press / buttonstomovearrowto‘pHSETUP’.
3. Press toenterthe‘pHSETUP’menu.
4. Usethe / buttonstohighlight‘TESTACID’andpress to
entertestacidmenu.
5. Awarningwillmomentarilybedisplayed,thenpress againtostartthepump.
Theacidpumpwillrunforapproximately10minutesandautomaticallyswitchoff.(Ifthepumpneedstobeturnedoffimmediately,pressthe
button)
NOTE:Steps1to5mayrequirerepeatingseveraltimesdependingonthelengthoftheacidsupplytube.
fIttIng tHe acId delIvery systeM testIng / prIMIng tHe acId pUMp
10 11
ThefollowinginformationaboutpHiscriticaltothesuccessfuloperationofyourswimmingpool.
Foradviceandsupplyofthecorrectproducts,consultyourlocalpoolcareprofessional.
preparIng tHe pool
TheTRi-pHunitisdesignedtomaintainthepHofthepool.
Byensuringthatthepooliscorrectlybalancedattheoutsetwilldecreasethechanceofproblems,duringthefirstdaysofoperation.
pH levels
IdealpHrangeformostpoolsis7.2–7.6
AllchemicalbalancesinthepoolareaffectedbypH,makingitthesinglemostimportantelementofswimmingpoolchemistry.
1. TolowerpHlevelusedilutedhydrochloricacidorphosphoricacid(thiswillbedoneautomaticallybytheTRi-pHonceconnected).
2. ToraisepH.Usesodaash.
total alKalInIty (ta) levels
IdealTAlevelrange:80-140partspermillion(PPM)
TotalAlkalinityisameasureofalkalinechemicalsinyourpoolandcanbeusedasa“buffer”tocontrolpHlevels.IfTAlevelsaretoolow,itmaystainpoolsurfacesandmakecontrollingpHlevelsdifficult.
IfTAlevelsaretoohigh,scalingmaybeevidentonpoolwallsandinthechlorinatorcells.
1. Toraisetotalalkalinity.AddpHbufferorstabilizer,accordingtomanufacturer’sinstructions.
2. Tolowertotalalkalinity.Addapproximately400mlofhydrochloricaciddaily.
3. Whentotalalkalinityhasstabilizedwithintheprescribedidealrange,youmayneedtoadjustthepool’spH.
pH controlpH control
10 11
cHlorIne levels
Idealchlorinelevelrange:1-3partspermillion(PPM).
PriortostartingtheTRi-pHthechlorinelevelcanberaisedusingeitherliquidorgranulatedchlorine.
salt levels
IdealSaltlevelrange:3000–5000partspermillion(PPM).
Efficientandcorrectoperationoftheelectrolyticcellrequiresasufficientamountofsaltinthewater.
Notenoughsaltmaycauseareducedchlorineoutputlevelandareducedlifeofthecell.
Toomuchsaltwillcauseeyeirritationandasaltytasteinthepoolwater.
filter / skimmer
Inadditiontothepoolchemistrybeingimportant,theconditionofthefiltrationsystemandskimmerbasketsmustbeassessed.Ifrequired,backwashthefilterandremovedebrisfromthepoolskimmerbasket(s).
aUtoMatIc detectIon
WhentheZodiacTRiUnitautomaticallydetectsthepresenceofaTRipHmoduleitdisplaysthepool’spHsetpoint.
1. Themessage‘pHCONTROL’appearsonthethirdlineofthescreen.
2. Thepool’spH“setpoint”isdisplayedatthebottomofthescreen. NOTE:Fromfactory,theaciddeliveryisdisabledandthepHsetpointwillbedisplayedas“----“.
Referto‘EnablinganddisablingtheAcidPump’formoreinformation.Whentheaciddeliveryisenabled,thepHsetpointisdisplayedatthebottomofthescreen.
pH controlpH control
12 13
WithpHsensorandaciddeliverycomponentssuccessfullysetup,theTRiunitneedstobecalibratedandsetupforpHcontrol.EnsurethatmainspowerissuppliedtotheTRi,turnthepoolpumpoffandisolatethepoolwatersothepHsensorcanbesafelyremoved.
1. RemovethepHsensorandcleanifnecessaryusingsoapywater.(Avoidtouchingtheglasstipofthesensor).Rinseoffwithfreshwater.
2. PlacethepHsensorinasampleofpHcalibrationsolutionwithapHlevelof7.5.
3. Leavethesensorimmersedinthesolutionforaminimumof30secondstosettle.
4. Fromthedefaultoperatingscreen,press .
5. Usethe / buttonstohighlight‘pHSETUP’,thenpress .
6. Usethe /buttonstohighlight‘CALIBRATEpH’,thenpress .
7. Observethe‘CURRENT’pHreading.Ifthereadingisabove8.2orbelow6.4,theremaybeaproblemwiththesensororpHunit.DONOTCONTINUEandrefertoyourlocalpoolprofessionalforassistance.
8. IftheCURRENTreadingiswithintheabovelimits,pressthe buttontobegincalibration.
9. Whencalibrationiscomplete,notethenewpHreading.Ifthereadingisnot7.5,repeattheprevious5steps.(IfthecurrentpHstilldoesn’tread7.5refertoyourlocalpoolprofessionalforassistance.)
10.Pressthe buttontwiceorwait30secondsandtheTRiunitwill
returntothedefaultoperatingscreen.
pH set poInt
12 13
pH set poInt
ThedefaultpHsettingofyourZodiacTRiis7.2.Thiscanbechangedaccordingtoyourpool’srequirements.
TochangethepHsetpoint:
1. CalibratethepHsensor.
2. Fromthedefaultoperatingscreen,press .
3. Usethe / buttonstohighlight‘pHSETUP’,thenpress .
4. Usethe / buttonstohighlight‘pHSETPOINT’,thenpress .
5. Usethe / buttonsuntilthedesired“setpoint”isachieved
Thenpressthe tosavethedesiredsetpointthenpress twice
togobacktooperatingscreenorwaitforoneminute.
14 15
pH set poInt pH set poInt
settIng tHe pool sIZe
this setting controls the maximum amount of acid which is delivered to the pool daily. your unit comes factory set on pool size 2.
the recommended settings for various size pools are as follows:
1: Forsmallpoolsupto40000litres
2: Formediumpools40000to60000litres
3: Forlargepools60000to100000litres
4: Foroversizepoolsabove100000litres
Theabovesettingsareaguidelineonly.Itisrecommendedthatalowersettingbeselectedinitially–thissettingcanbeincreasedatalatertimeifinsufficientacidisbeingdosedtomaintainthecorrectpHlevel.
Tosetthepoolsize,followtheprocedurebelow:
1. Fromthedefaultoperatingscreen,press .
2. Usethe / buttonstohighlight‘pHSETUP’,thenpress .
3. Usethe / buttonstohighlight‘POOLSIZE,thenpress .
4. Usethe / buttonstoselectthepoolsizetothedesiredvalue.
Thenpress tosave.
5. Nowpress twicetoreturntothemainoperatingscreen.
(Orthiswillautomaticallyhappenafteroneminute)
NOTE: Acid is dosed into the pool while the chlorinator and filtration system are running.
14 15
pH set poInt pH set poInt
WarnIng! It is advised that the pool size be set as low as possible to avoid overdosing acid into the pool.
UsIng pH control
TheTRi-pHisnowreadyforusewithautomaticpHcontrol.
1. Set‘ON’and‘OFF’times.
2. Selectdesiredchlorineoutputlevel.
3. EnabletheAcidPump(RefertoEnablinganddisablingtheAcidPump.)
TheTRiunitwillnowautomaticallymaintainthepHlevelofthepool.
16 17
AlthoughautomaticpHcontrolreducestheneedforregulartesting,therearestillanumberofcheckstoensurethesafeoperationofthesystemandapleasantswimmingexperience.
always check:
Acidsupplylevels.
TotalAlkalinity.
TheaccuracyofthepHsensorbymanuallycheckingthepHlevel.
ThatthepHsensoriscleanedandre-calibrated.
acid pump and feed line Maintenance
1. Lubricatethepumpsqueezetubeevery6months.Uselubricantrecommendedbyyourlocalpoolcareprofessional
2. Thepumpsqueezetubeisawearingitemandmayneedtobereplacedduringthelifeoftheproduct,regularcheckingwillletyouknowwhenthisisneeded.
please note: peristaltic pump and associated fittings, tubing etc are covered by a 1 year limited* warranty only
3. Theacidinjectionpointandfeedlinesshouldbecheckedforblockagesandbecleanedasrequired.Alwaysensureyouwearappropriatesafetyequipmentwhenhandlingacid
*seewarrantytermsandconditionsattheendofthismanual
adjUstIng total alKalInIty (ta) regUlar cHecK Ups
16 17
Asacidisaddedautomaticallyovertime,totalalkalinitylevelswilldecreaseandmayresultininconsistentpHlevels.
Itmaybenecessarytoadda“buffer”elementtothewaterinyourpool.
Asitisnotrecommendedtoaddacidafteraddinga“buffer”,temporarilydisabletheacidpump(refertoEnablinganddisablingtheacidpump).
enaBlIng and dIsaBlIng tHe acId pUMp.
Intheinterestsofsafety,theZodiacTRi-pHisshippedwiththeacidpumpdisabled.
WhenaTRi-pHisconnected,theacidpumpisprogrammedtobeginoperationafterapproximately8hoursofbeingactivated.Thiscanbeoverriddenbydisablingtheacidpump.
Whentheacidpumpisdisabled,thesetpointreadingwillbereplacedwith“---“untiltheacidpumpisre-enabled.
After8hours,thedeactivatedpumpwillautomaticallyre-enableitself.
to enable the acid pump manually:
1. Fromthedefaultoperatingscreen.
2. Pressthe button.
3. Press / buttonstomovearrowto‘pHSETUP’.
4. Press toenterthepHmenu.
5. Usethe / buttonstohighlight‘ACIDPAUSED’
(OR‘ACIDENABLED’).
6. Press totogglebetween‘ACIDENABLED’and‘ACIDPAUSED’.
7. Oncetheappropriateselectionhasbeenmade,press twiceorwait
~60secondsfortheTRitorevertbacktothedefaultoperatingscreen.
adjUstIng total alKalInIty (ta) regUlar cHecK Ups
18 19
WhenusingautomaticpHcontrol,therequirementforregularpoolchemistrychecksislowered.Itishowever,necessarytoregularlycheckanumberofcriticalthingstoensuresafeandcorrectoperationofthesystem:
cleanIng tHe pH sensor
Whencleaningthesensoravoidusingsolventssuchasacetone.Alwayscalibrateaftercleaning.
Tocleanthesensor:
Iftheelectrodehasbecomecoatedwithoilorgrease,carefullywashtheelectrodeunderwarmtapwaterusingdish-washingdetergent.Rinsethesensorthoroughlywithcleantapwater.
Iftheaboveproceduredoesnotwork,soakthesensorinadilutedhydrochloricacid(HCL)solutionfor10seconds.
Thiscanbepurchasedfromyourlocalpoolprofessionalormadebycarefullyaddingone(1)partofHydrochloric(Muriatic)acidtoten(10)partswaterinasuitablecontainer.ALWAYSADDACIDTOTHEWATER.Aftersoaking,rinsethesensorthoroughlyincleantapwaterandrecalibratebeforeuse.
Iftheabovetwoproceduresfailtorestorethesensor,thesensorshouldbereplaced.
errors and WarnIngs. WHat tHey Mean.
18 19
errors and WarnIngs. WHat tHey Mean.
pH loW
Diagnosis:thepHLevelinthepoolhasdroppedtoofarbelowthesetpoint.ThiscouldindicatethePOOLSIZEsettingistoohigh,causingacidtooverdoseorthepHsensorisfaultyorneedscalibrationand/orcleaning.Manuallytestthepool’spHbeforefurtherinvestigation,ifallequipmentisoperatingfinethenadjustyourpoolsettingtoalowervalue.
pH error
Diagnosis:theacidpumphascompleteditsdosingcycleswithoutreachingthesetpoint.Thiscouldindicatetheacidsupplyisempty,thepHsensorisfaultyorneedingcalibration/cleaning,thePoolsizeissettoolowortheacidpumpisfaulty.Toclearthiserrorpleaseholddowntheselectbuttonfor5seconds(theTRimustbeon).
additional information about this product can be found at zodiac.com.au
Forfurtherinformationandassistancepleaseconsultyourlocalpoolprofessional.
your local dealer:
20 21
express Warranty and gUarantees notes
express WarrantyZodiac GroupAustralia Pty Ltd (Zodiac australia)warrants that theTRi-pHChlorinatorwill be free fromdefects inmaterialsandworkmanship.TheCellandPowerPackiswarrantedfortheperiodofthree(3)years,ifusedinadomestic/residentialpool.ThePeristalticpump,sensorsandotherextraneousequipmentareconditionallywarrantedfortheperiodoftwelve(12)months,ifusedinadomestic/residentialpool.conditions1 ThisexpresswarrantyonlyappliesiftheProducthasbeen
purchasedfromadealerauthorisedbyZodiacAustraliatosupplyit(authorised dealer).Purchase from anAuthorisedDealer ensures that theproductisagenuineZodiacproduct,thatitistheversiondesignedforAsiaPacificconditions,andthatthePurchaserhasaccesstoappropriatetechnicalknowledgeandadvice.
2 ZodiacAustralia’sliabilityunderthisexpresswarrantyislimited,atitsoption,totherepairorreplacementoftheProductorthepaymentofthecostofhavingtheProductrepairedorreplaced.
3 This expresswarranty does not apply in the followingcircumstances:(a)iftheProducthasnotbeeninstalledinaccordancewith
Zodiac’sinstallationinstructions;(b)if the Product has been modified other than as
authorisedbyZodiacAustraliaorifacomponentparthasbeenreplacedbyapartthatisnotagenuineZodiacproduct;
(c)if a defect results fromuse of the Product outsiderecommendedoperatingconditions;or
(d)ifadefectresultsfromdamage(includingdamagetoanyinternalelectronics)causedbyapowersurgeorlightningstrike.
Zodiacchlorinatorsaredesignedandtestedinaccordancewith International Standard EN 61000-6-1 immunitymeasurements. They are designed to tolerateminorfluctuations (2000 volts) in power supply that can bereasonablyexpectedtooccur intheenergygrid. Theywillnottoleratepowersurgesoutsidethese limitsnorwilltheywithstandlightningstrikes.
4 Withoutlimiting3above,productssoldbyZodiacAustraliaaredesignedforusewithswimmingpoolwaterbalancedinaccordancewithAustralianStandardAS3633-1989withapHrangeof7.0-7.8.Maximumchlorinereadingsshouldnotexceed4ppm.Wherepoolwaterisnotmaintainedwithin these parameters, ZodiacAustraliawill not beresponsibleunderthisexpresswarrantyforanyresultingdamage,includingdamagecausedbycorrosion,scalingorstressloading.
5 Replacementpartssuppliedunderthisexpresswarrantyarewarrantedtobe free fromdefects inmaterialsandworkmanshipfortheremainderofthewarrantyperiodor for 12months from the supply of the replacement,whicheverislonger.
6 Warrantyclaimsrelatingtoreplacementoftheelectrodesfor LM series, C series, Duo Clear and D serieschlorinatorsaresubjecttothefollowingpro-ratapricingprocedure.ThePurchasermustpayforthereplacementelectrodeaproportionofthecostequaltothatproportionof the warranty period during which the originalelectrode functioned effectively. Thewarranty periodfor the replacement electrode is the remainder of thewarrantyperiodfortheoriginalelectrodeor12monthsfromthesupplyofthereplacement,whicheverislonger.The Purchasermust pay full cost for any replacementelectrodesafterthefirstreplacement.
product warranty registration7 Purchasers should register their Products as soon as
conveniently possible after purchase by completing aProductWarrantyRegistration Form and posting it toZodiacAustraliaattheaddressshownontheFormorbyregisteringonlineatwww.zodiac.com.au.
8 Productregistrationmustoccur,andproofofpurchasemustbereceivedbyZodiacAustralia,priortoanywarrantyworkbeingapproved.Whereapplicable,aserialnumber,installationdateandnameofinstallerisrequiredaspartoftheregistrationprocess.
How to make a warranty claim9 ThePurchasermusttelephoneoremailZodiacAustralia
CustomerServiceandobtainawarrantyIDnumberforthewarrantyclaim.Contactdetailsare:Zodiac group australia pty ltd 219WoodparkRoadSmithfieldNSW2164customer service Telephone:1800688552Emailaddress:[email protected]
10ZodiacAustraliareservestherighttodetermine,inrelationtoeachwarrantyclaim,whethertheProductshouldbereturnedtotheAuthorisedDealerattheaddresswherethePurchaserpurchasedtheProductorwhetherwarrantyservicewillbeprovidedinthefield,repairedataZodiacworkshopor at the premises of an authorizedZodiacwarrantyagent.
11IfitisnecessaryforthePurchasertoincurfreightchargesinmakingavalidclaimunderthiswarranty,ZodiacAustraliawill reimburse the Purchaser for charges reasonablyincurreduponproofofthecharges.
additional guarantees, rights and remediesaustralian purchasers - guarantees under the australian consumer law12The benefits of this expresswarranty are in addition
to other guarantees, rights and remediesAustralianconsumershaveundertheAustralianConsumerLaw.
13ZodiacAustralia products comewith guarantees thatcannotbeexcludedundertheAustralianConsumerLaw.Youareentitledtoareplacementorrefundforamajorfailure and for compensation for any other reasonablyforeseeablelossordamage.Youarealsoentitledtohavethegoodsrepairedorreplacedifthegoodsfailtobeofacceptablequalityandthefailuredoesnotamounttoamajorfailure.
purchasers in other countries14Thelawsandregulationsofothercountriesmayconfer
on Purchasers in those countries additional rights andremedies. To theextent that they cannotbeexcludedormodified,Purchasershavethebenefitsofthoserightsandremediesinadditiontothebenefitsofthisexpresswarranty.Tothefullextentthat it ispermissibletodoso,thoseadditionalrightsandremediesareexcludedormodifiedsoas tobeconsistentwithZodiacAustralia’sexpresswarranty.
I n con s I s t e n c y W I t H Wa r r a n t y stateMents In prodUct ManUals or otHer docUMents accoMpanyIng prodUctsIf anywarranty statements in aZodiacAustralia productmanualorotherdocumentareinconsistentwiththeaboveExpressWarrantyandGuarantees,theaboveoverridesandreplacestheinconsistentstatements.
20 21
express Warranty and gUarantees
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
notes
W176831REVA
Zodiac customer service centre
ZodiacGroupAustralia:
219WoodparkRd,Smithfield,
NSW2164Australia
Tel:1800688552
Fax:1300781688
Email:[email protected]
www.zodiac.com.au
Duetoconstantdevelopmentsandimprovements,specificationsmaychangewithoutnotice.
Improperusecouldaffectperformanceandvoidwarranty.