tri-mer precision-engineered direct drive blowers
TRANSCRIPT
Tri-Mer Blowers Are Low Noise,Low Vibration
DevelopedExclusivelyfor theWorldwideSemiconductorIndustry
Tightening regulations, and increased ergonomic concerns, haveincreased the demand for blowers designed without conventionalsheaves, belts and similar items which produce vibration, raise main-tenance costs and contribute to a range of other problems as well.
Tri-Mer engineered blowers, such as those shownhere, feature direct-drive coupling motor set-up. They are an excellent alternative forsemiconductor manufacturing and otherapplications with high standards for
performance and service life.
Tri-Mer® Precision-EngineeredDirect Drive Blowers
High-Integrity Polypropylene Construction forMaximum Corrosion Resistance
The standard Tri-Mer design for Direct Drive Blowers uses a corro-sion-resistant, polypropylene housing; internal and external supportmembers related to the housing are also manufactured from rigidpolypropylene. Polypropylene is the most effective material forthese applications, and is far superior to fiberglass and other blowermaterials where structural integrity must be combined with excellentresistance to corrosion, wear and mechanical stresses.
Tri-Mer fan systems are also manufactured from rigid PVC, and areoften recommended for ambient temperature processes. Rigid PVCprovides structural integrity similar topolypropylene.
Engineered for Easy Accessand Simplified Maintenance
Tri-Mer Direct Drive Blowers incorporatefan impellers which are custom-engineeredfor your application by New York BlowerCompany. Tri-Mer’s 43 years experiencein the design and fabrication of polypro-pylene equipment, combined with theproven performance of New York Blowerproducts, insures constant, reliable performance.
®
Tri-Mer®
CORPORATION
1400 Monroe St. • P.O. Box 730 • Owosso, MI 48867-0730Phone (989) 723-7838 • FAX (989) 723-7844
www.tri-mer.com • [email protected]© 2003 Tri-Mer Corp.
Quality Design/Build Services Since 1965
Tri-Mer® Direct Drive Blowers
Custom Models Available?
Use Indoors or Out?
OEM Discounts?
U.S. Made?
YES
YES
YES
YES
Housing Construction
Operating Temperatures
Fan Impellers
HP Range
Wheels
Capacity
Pressures
Polypropylene or PVC
To 180°F
18” to 73” Diameter
Up to 300
Backward-inclined; Class I, II, III or IV
1200 to 150,000 cfm
To 20” w.g.
Consult our factory for fan curves relevant to specific applications.
Tri-Mer also offers a complete line of standardbelt-driven blowers with capacities through200,000 cfm in PVC and polypropylene.