TruSet QUICK Reference Guide TruSet TruSet Run Screen Setup Select to configure tool. Warning Setup Select to set downforce warnings. Float Mode Select to toggle the float mode on and off. Option only available when selecting Manual SCV with Power Beyond. Diagnostics Select to enter diagnostic information. TruSet Main Menu button. TruSet Press plus or minus button to increase or decrease the downforce. Select to choose from a list of programmed downforce setpoints. Select to enter calibration screens, input downforce setpoints, and to verify the tractor SCV controlled by automation. Disables the downforce system. Enables the downforce system. N 734 N 734 Front Rear Front Rear (N) 286 (N) 286 734 734 734 Rear Enter a value to increase or decrease the downforce.

Upload: others

Post on 20-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TruSet Quick Reference Guide - John Deere · 2019. 9. 27. · TruSet™ Quick Reference Guide TruSet TruSet Run Screen Setup – Select to configure tool. Warning Setup – Select

TruSet™ Quick Reference Guide

TruSet

TruSet Run Screen

Setup – Select to configure tool.

Warning Setup – Select to set downforce warnings.

Float Mode – Select to toggle the float mode on and off. Option only available when selecting Manual SCV with Power Beyond.

Diagnostics – Select to enter diagnostic information.

TruSet – Main Menu button.TruSet

Press plus or minus button to increase or decrease the downforce.

Select to choose from a list of programmed downforce setpoints.

Select to enter calibration screens, input downforce setpoints, and to verify the tractor SCV controlled by automation.

Disables the downforce system.

Enables the downforce system.

N 734 N 734

Front Rear

Front Rear

(N)

286(N)

286

734 734

734

RearEnter a value to increase or decrease the downforce.

Page 2: TruSet Quick Reference Guide - John Deere · 2019. 9. 27. · TruSet™ Quick Reference Guide TruSet TruSet Run Screen Setup – Select to configure tool. Warning Setup – Select

This is the time that the SCV remains on to ensure that the Power Beyond Activates.

Select SCV Configuration.

Select SCV Configuration.

Enable or Disable Continuous SCV Time.

Select Opener Control (SCV with Power Beyond,

SCV Only).

Select Opener Control

(SCV with Power Beyond,

SCV Only).

Enter values for the extend and retract

thresholds if necessary.

Select Opener Control SCV

(SCV1-6).

Select Opener Control SCV

Manual (- - -).

Tool Setup — Automated SCV Tool Setup — Manual SCV

Setup

CAL Tool

SCV Configuration

SCV with Power Beyond

SCV Time

20 S

C

Opener Control

SCV

Variable Rate

Setup

CAL Tool

SCV Configuration

SCV with Power Beyond

Activation Threshold - Pressure

Extend 8274 kPa

Retract 6205 kPa

Opener Control

SCV

Variable Rate

Page 3: TruSet Quick Reference Guide - John Deere · 2019. 9. 27. · TruSet™ Quick Reference Guide TruSet TruSet Run Screen Setup – Select to configure tool. Warning Setup – Select

Tool Setup

Select Implement Detection.

Select Tool Model.

Select Nominal Tool Width.

Select row spacing.

Press to save the values.

Select Opener Configuration.

Enable and Disable Opener Control.

Select Opener Depth Setting (1-13).

Setup

Setup

CAL Tool

CAL Tool

Implement Detection

Opener Configuration

Front Opener Rear Opener

Depth Setting 7 Depth Setting 7

Enable Enable

1895

18.3

25.4

Model

Width (m)

Row Spacing (cm)

Variable Rate

Variable Rate

Press Enter to Save Values

Page 4: TruSet Quick Reference Guide - John Deere · 2019. 9. 27. · TruSet™ Quick Reference Guide TruSet TruSet Run Screen Setup – Select to configure tool. Warning Setup – Select

Copyright © 2018 Deere & Company. All Rights Reserved. THIS MATERIAL IS THE PROPERTY OF Deere & Company. ALL USE AND OR REPRODUCTION NOT SPECIFICALLY AUTHORIZED BY Deere & Company IS PROHIBITED.

All information, illustrations, and specifications in this manual are based on the latest information available at the time of publication. The right is reserved to make changes at any time without notice.

QRGA116077 (04APR18)

Printed in U.S.A.

Enable Pick 6 Prescription. Enter Delayed Time for the Downforce Disabled Warning.

Enter Delayed Time for the Failure to Reach the Setpoint Timeout.

Enter Target Setpoint for Downforce.

Warning Setup

Delay

Downforce Disabled Warning 5 Sec

Failure to Reach Setpoint 60 Sec Timeout

Tool Setup Warning Setup

Setup

CAL Tool Variable Rate

N Front Rear I/O

1 734 734

2 1000 1000

3 1250 1250

4 1500 1500

5 1750 1750

6 734 734