truset quick reference guide - john deere · 2019. 9. 27. · truset™ quick reference guide...
TRANSCRIPT
TruSet™ Quick Reference Guide
TruSet
TruSet Run Screen
Setup – Select to configure tool.
Warning Setup – Select to set downforce warnings.
Float Mode – Select to toggle the float mode on and off. Option only available when selecting Manual SCV with Power Beyond.
Diagnostics – Select to enter diagnostic information.
TruSet – Main Menu button.TruSet
Press plus or minus button to increase or decrease the downforce.
Select to choose from a list of programmed downforce setpoints.
Select to enter calibration screens, input downforce setpoints, and to verify the tractor SCV controlled by automation.
Disables the downforce system.
Enables the downforce system.
N 734 N 734
Front Rear
Front Rear
(N)
286(N)
286
734 734
734
RearEnter a value to increase or decrease the downforce.
This is the time that the SCV remains on to ensure that the Power Beyond Activates.
Select SCV Configuration.
Select SCV Configuration.
Enable or Disable Continuous SCV Time.
Select Opener Control (SCV with Power Beyond,
SCV Only).
Select Opener Control
(SCV with Power Beyond,
SCV Only).
Enter values for the extend and retract
thresholds if necessary.
Select Opener Control SCV
(SCV1-6).
Select Opener Control SCV
Manual (- - -).
Tool Setup — Automated SCV Tool Setup — Manual SCV
Setup
CAL Tool
SCV Configuration
SCV with Power Beyond
SCV Time
20 S
C
Opener Control
SCV
Variable Rate
Setup
CAL Tool
SCV Configuration
SCV with Power Beyond
Activation Threshold - Pressure
Extend 8274 kPa
Retract 6205 kPa
Opener Control
SCV
Variable Rate
Tool Setup
Select Implement Detection.
Select Tool Model.
Select Nominal Tool Width.
Select row spacing.
Press to save the values.
Select Opener Configuration.
Enable and Disable Opener Control.
Select Opener Depth Setting (1-13).
Setup
Setup
CAL Tool
CAL Tool
Implement Detection
Opener Configuration
Front Opener Rear Opener
Depth Setting 7 Depth Setting 7
Enable Enable
1895
18.3
25.4
Model
Width (m)
Row Spacing (cm)
Variable Rate
Variable Rate
Press Enter to Save Values
Copyright © 2018 Deere & Company. All Rights Reserved. THIS MATERIAL IS THE PROPERTY OF Deere & Company. ALL USE AND OR REPRODUCTION NOT SPECIFICALLY AUTHORIZED BY Deere & Company IS PROHIBITED.
All information, illustrations, and specifications in this manual are based on the latest information available at the time of publication. The right is reserved to make changes at any time without notice.
QRGA116077 (04APR18)
Printed in U.S.A.
Enable Pick 6 Prescription. Enter Delayed Time for the Downforce Disabled Warning.
Enter Delayed Time for the Failure to Reach the Setpoint Timeout.
Enter Target Setpoint for Downforce.
Warning Setup
Delay
Downforce Disabled Warning 5 Sec
Failure to Reach Setpoint 60 Sec Timeout
Tool Setup Warning Setup
Setup
CAL Tool Variable Rate
N Front Rear I/O
1 734 734
2 1000 1000
3 1250 1250
4 1500 1500
5 1750 1750
6 734 734