twinplus 310-320w

2
ELECTRICAL TYPICAL VALUES Model Type Rated Power (Pmpp) Tolerance Rated Current (Impp) Rated Voltage (Vmpp) Short Circuit Current (Isc) Open Circuit Voltage (Voc) Module Efficency (%) Voltage Temperature Coefficient Current Temperature Coefficient Power Temperature Coefficient NOCT (Nominal Operation Cell Temperature) Monocrystalline 6 inch x 3 inch square Note: This datasheet is not legally binding. Phono Solar Technology Co., Ltd. reserves the right to adjust specifications without notice. Further information please refer to our Website:www.phonosolar.com, E-mail:[email protected] 43±20~+5w -0.286%/+0.051%/-0.368%/315W PS315M-20/UH 9.31 33.84 9.76 40.11 18.96 320W PS320M-20/UH 9.39 34.08 9.85 40.35 19.26 310W PS310M-20/UH 9.22 33.63 9.67 39.90 18.66 PS315MH-20/UH PS320MH-20/UH PS310MH-20/UH 10 12 8 6 4 2 0 0 5 Current [A] 10 20 15 40 35 30 25 Cell temp.=25Incident Irrad.=1000W/m2 Incident Irrad.=800W/m2 Incident Irrad.=600W/m2 Incident Irrad.=400W/m2 Incident Irrad.=200W/m2 MECHANICAL CHARACTERISTICS Dimension (L× W × H) Weight Front Glass Frame Cable Junction Box Length: 1675mm (65.95 inch) Width: 992mm (39.06 inch) Height: 35mm (1.38 inch) 18.5kg (40.78 lbs) 3.2mm toughened glass Anodized aluminium alloy 4mm² (IEC) Length:350mmvertical1150mmhorizontalor Customized length IP 68 rated ABSOLUTE MAXIMUM RATING Parameter Values Operating Temperature Hail Diameter @ 80km/h Surface Maximum Load Capacity Maximum Series Fuse Rating Application Class and Safety Class Fire Rating (IEC61730) From -40 to +85°C Up to 25mm Up to 5400Pa 20A C Module Fire Performance (UL 1703) Type1 Maximum System Voltage DC 1000V/1500V (IEC/ETL) PACKING CONFIGURATION Container Pieces/Container 20' GP 312 40' HQ 832 ELECTRICAL CHARACTERISTICS 1. In compliance with our warranty terms and conditions. 2. Measurement conditions under irradiance level of Standard Test Conditions(STC): 1000W/m Air mass 1.5 Spectrum, cell temperature of 25°C. 250 300 350 200 150 100 50 0 0 10 20 Voltage [V] Power [W] 30 40 Cell temp.=25Incident Irrad.=1000W/m2 Incident Irrad.=800W/m2 Incident Irrad.=600W/m2 Incident Irrad.=400W/m2 Incident Irrad.=200W/m2 T O P P E R F O R M E R 2018 PV MODULE RELIABILITY SCORECARD 310-320W TwinPlus Outstanding performance in weak-light conditions PID Anti-PID 25 YEARS 15-year product warranty 25-year linear performance warranty Excellent temperature coefficient gives higher yields in the long term True Black

Upload: others

Post on 23-Dec-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

ELECTRICAL TYPICAL VALUES

Model

Type

Rated Power (Pmpp)

Tolerance

Rated Current (Impp)

Rated Voltage (Vmpp)

Short Circuit Current (Isc)

Open Circuit Voltage (Voc)

Module Efficency (%)

Voltage Temperature Coefficient

Current Temperature Coefficient

Power Temperature Coefficient

NOCT (Nominal Operation Cell Temperature)

Monocrystalline 6 inch x 3 inch square

Note: This datasheet is not legally binding. Phono Solar Technology Co., Ltd. reserves the right to adjust specifications without notice. Further information please refer to our Website:www.phonosolar.com, E-mail:[email protected]

43±2℃

0~+5w

-0.286%/℃

+0.051%/℃

-0.368%/℃

315W

PS315M-20/UH

9.3133.849.76

40.1118.96

320W

PS320M-20/UH

9.3934.089.85

40.3519.26

310W

PS310M-20/UH

9.2233.639.67

39.9018.66

PS315MH-20/UH PS320MH-20/UHPS310MH-20/UH

10

12

8

6

4

2

00 5

Curre

nt [A

]

10 2015 40353025

Cell temp.=25℃

Incident Irrad.=1000W/m2

Incident Irrad.=800W/m2

Incident Irrad.=600W/m2

Incident Irrad.=400W/m2

Incident Irrad.=200W/m2

MECHANICAL CHARACTERISTICS

Dimension (L× W × H)

Weight

Front Glass

Frame

Cable

Junction Box

Length: 1675mm (65.95 inch)

Width: 992mm (39.06 inch)

Height: 35mm (1.38 inch)

18.5kg (40.78 lbs)

3.2mm toughened glass

Anodized aluminium alloy

4mm² (IEC) ,Length:350mm(vertical)1150mm(horizontal)or Customized length

IP 68 rated

ABSOLUTE MAXIMUM RATINGParameter Values

Operating Temperature

Hail Diameter @ 80km/h

Surface Maximum Load Capacity

Maximum Series Fuse RatingApplication Class and Safety Class

Fire Rating (IEC61730)

From -40 to +85°C

Up to 25mm

Up to 5400Pa

20A Ⅱ

C Module Fire Performance (UL 1703) Type1 Maximum System Voltage DC 1000V/1500V (IEC/ETL)

PACKING CONFIGURATIONContainer

Pieces/Container

20' GP312

40' HQ832

ELECTRICAL CHARACTERISTICS

1. In compliance with our warranty terms and conditions.2. Measurement conditions under irradiance level of Standard Test Conditions(STC): 1000W/mAir mass 1.5 Spectrum, cell temperature of 25°C.

250

300

350

200

150

100

50

00 10 20Voltage [V]

Powe

r [W

]

30 40

Cell temp.=25℃Incident Irrad.=1000W/m2Incident Irrad.=800W/m2Incident Irrad.=600W/m2Incident Irrad.=400W/m2Incident Irrad.=200W/m2

TOP PERFORMER2018

PV MODULERELIABILITY SCORECARD

310-320WTwinPlus

Outstanding performance in weak-light conditions

PID Anti-PID

25YEARS

15-year product warranty25-year linear performance warranty

Excellent temperature coefficient gives higher yields in the long term

TrueBlack

MORE RELIABILITY BETTER SHADING PERFORMANCE

BETTER OUTDOOR PERFORMANCE

The low current can significantly reduce the risk of hot spot, increase durability and avoid damages to modules because of shading, which makes Phono Solar TwinPlus module a perfect solution for rooftops.

Low temperature coefficient of Phono TwinPlus module can bring more power generation at high operating temperatures. According to weekly power generation experimental data in the table below, half cell modules can generate 4.64% additional power in average.*

MORE POWER FROM HIGH MODULE EFFICIENCY

4.95KWPoly Module 270W 5.76KWTwinPlus 320W

kwh/KW

2.2kwh/KW

2.3kwh/KW

4.5

4.0

3.5

3.0

2.5

2.0

1.5

1.0

0.5

0.0

Cloudy 1 Sunny 1 Cloudy 2 Rainy 1 Cloudy 3 Rainy 1 Rainy 2 Rainy 3 Cloudy 4

Power Generation Comparison

* The data above is based on the outdoor environment located in Nanjing China. The test time is from10am to 15pm. Data may vary in different environments.

Power generation of half cell modules/ /KW Power generation of conventional module/ /KW

Arverage of half cell modules Averrage of sconventional modules

TYPE

Full cell module

Half cell module

VALUESRated Power

Power loss

Rated Power

Power loss

A305w

0

320w

0

B198w

35.22%

284w

11.15%

C40w

87.17%

208w

35.15%

D32w

89.66%

182w

43.18%

ShadingShading Shading

Full Full Half Full HalfHalf

Power loss35.22%

Power loss11.15%

Power loss35.15%

Power loss87.17%

Power loss43.18%

Power loss89.66%

Heavy snow load up to 5400 Pa, wind load up to 2400 Pa

Low power loss in cell connection

Minimizes micro-cracks

Lower hot spot temperature

IP68 IP68 connectors enhance the reliability of the PV system

Certified Quality Brings You More Reliability

Less shading effect

97%

100%

80.7%90%

70%0 5 10 15 20 25 Year

15-year product warranty25-year linear performance warranty