ucs 500n5t series - gomeasuregomeasure.dk/wp-content/uploads/2017/02/ucs500n5t.pdf · range the...
TRANSCRIPT
DATA SHEET > UCS 500N5T > 20151007
UCS 500N5T SERIESMULTIFUNCTIONAL TESTGENERATOR FOR CONDUCTEDTRANSIENTS (EFT/BURST, SURGE, TELECOM-SURGE & POWERFAIL) UP TO 5.5KV FOR TESTS ACCORDING TO ...
> EN 300329> EN 300340> EN 300342-1> EN 300386 V1.3.2> EN 301489-1> EN 301489-17> EN 301489-24> EN 301489-7> EN 50121> EN 55024> EN 61000-4-11> EN 61000-4-29> EN 61000-4-4> EN 61000-4-5> EN 61000-4-8> EN 61000-4-9> EN 61000-6-1> EN 61000-6-2> FCC 97-270 (part 68)> IEC 60255-22-5> IEC 61000-4-11> ...
UCS 500N5T SERIES - COMPACT TESTER FOR EFT/BURST, SURGE, TELECOM-SURGE AND POWER FAIL
The UCS 500N5T Series ultra-compact simulator is the most versatile tester to cover transient and power fail requirementsaccording to international standards (basic and generic standards) and product/product family standards. The UCS 500N5TSeries is the most economic solution for tests during development as well as for full-compliant immunity tests and CEMarking for single phase DUT with the ability to be extended for testing three-phase DUTs by means of an automaticallycontrolled external coupling network up to 200 A.EM TEST supplies a large range of accessories for the various applications such as magnetic field tests.
HIGHLIGHTS
> Burst module IEC/EN 61000-4-4 (up to 5.5 kV)
> Surge module IEC/EN 61000-4-5/-9 (up to 5 kV)
> TSurge module IEC/EN 61000-4-5 up (to 5 kV)
> PowerFail module IEC/EN 61000-4-8/-11/-29 (DC)
> Built-in single phase coupler 300 V/16 A
> Manual operation from front panel
> USB and GPIB-Bus for remote control
APPLICATION AREAS
INDUSTRY
MEDICAL
RESIDENTIAL
TELECOM
COMPONENTS
BROADCAST
RENEWABLE ENERGY
www.emtest.com © EM TEST > PAGE 1/9
DATA SHEET > UCS 500N5T > 20151007
TECHNICAL DETAILS
BENEFITS
ALL IN ONE - ALL WHAT YOU NEED FOR YOUR TESTS
The UCS 500N5T Series includes everything necessary toconduct fully compliant tests. The power mains supply forthe controls and for the DUT is separate to render it moreflexible to use with different DUT supply voltages.The UCS 500N5T Series can be operated manually fromthe front panel or by remote via the built-in USB or GPIBinterface. Fail inputs allow to control an ongoing testsequence based on the status of the DUT. Monitoringoutputs (BNC) are offered for easy signal measurementand verification. Safety features such as interlock andwarning lamp control are available.Pre-programmed Standard Test routines allow highestuser convenience. Still the UCS 500N5T Series offers theQuick Start test routine where parameters can be changedon-line during the test to evaluate the susceptibility levelof an individual DUT.
OPERATION
EASY TO OPERATE
Front panel menu and function keys enable the user toprogram his test routines quickly and accurately. Thecursor allows fast control of all test parameters of theprogrammed routine, thus test procedures are simplifiedand confidence is generated that every step is carried outcorrectly.
SOFTWARE
IEC.CONTROL SOFTWARE FOR CONTROL ANDDOCUMENTATION
User convenience, clearly structured windows andoperation features and the unique EM TEST standardslibrary along with the flexibility to generate user specifictest sequences very easily are the main features ofiec.control software. The software is automaticallyconfigured according to the connected EM TESTgenerators. Extensive reporting capabilities help the userto create test reports that meet internationalrequirements.iec.control is supported by Windows XP, Windows Vista,Windows 7 and Windows 8. Remote control is achievedeither via USB or GPIB. iec.control supports a wide rangeof GPIB cards of National Instruments.
OTHER MODELS
UCS 500N SERIES - COMPACT TESTERS UP TO 7KV
The ultra-compact testers UCS 500NT for EFT/Burst, Surgeand Power Fail are available in different models; withvoltage capability up to 5.5 kV or up to 7 kV.
www.emtest.com © EM TEST > PAGE 2/9
DATA SHEET > UCS 500N5T > 20151007
TECHNICAL DETAILS
AUXILIARY DEVICES
CNI 503 - 3PHASE COUPLING/DECOUPLING NETWORKSFOR BURST AND SURGE
EM TEST offers a range of fully automatic 3-phasecoupling/decoupling networks for burst and surge toextend the test capability for three-phase DUTs. Thenetworks have a rated current of up to 200 A.
MV 2616 / MV 2632 - MOTORISED VARIAC FOR VOLTAGEVARIATION
A motorised variac is offered as an alternative to thetapped autotransformers for voltage dips/interruptionsand voltage variation tests as per IEC/EN 61000-4-11. Themotorised variac can also be used for automatedmagnetic field tests.
V 4780 - TAPPED VOLTAGE TRANSFORMER FOR VOLTAGEDIPS
The V 4780 tapped autotransformer is designed to supplythe required voltages as per IEC 61000-4-11 Ed.2:2004 toperform voltage dips.
V 4780S2 - TAPPED VOLTAGE TRANSFORMER FORVOLTAGE DIPS
The V 4780S2 tapped autotransformer is designed tosupply the required voltages as per IEC 61000-4-11Ed.2:2004 to perform voltage dips. Compared to themanually operated V 4780 the V 4780S2 model offersautomatic change of taps according to the selectedvoltage level.
CNV 504/508 N- AND T SERIES - SURGECOUPLING/DECOUPLING NETWORKS FOR SIGNAL/DATALINES
CNV 504/508N- and T-series coupling/decouplingnetworks are available to perform surge tests on I/O lines,signal/data lines and telecom lines as per IEC/EN61000-4-5 Ed 3.0.
ACCESSORIES
MS 100N - MAGNETIC FIELD COIL FOR POWER-FREQUENCYAND PULSED MAGNETIC FIELDS
The MS 100N is a 1sqm magnetic field coil as specified inIEC/EN 61000-4-8 and IEC/EN 61000-4-9. Its designallows easy moving of the coil. The field coil is adjustablein height and allows for 360degr rotation.To generate power-frequency magnetic fields in the lowerrange the current transformer MC 2630 is used whilehigh-field strength above 100 A/m requires the MC 26100current transformer.
HFK - CAPACITIVE COUPLING CLAMP
Capacitive coupling clamp as per specification IEC/EN61000-4-4.
ITP - IMMUNITY TEST PROBES
ITP is a tool being used for development test. It consistsof a variety of electrical field probes. The probes allow tolocate weak points within a system or on a PCB. The burstpulse is used to generate the disturbance signal.
CA EFT KIT - VERIFICATION KIT FOR EFT/BURST PULSES
The pulse shape of EFT/burst generators designed as perIEC/EN 61000-4-4 have to be verified both into a 50ohmand a1,000ohm load at the 50ohm coaxial HV output as wellinto 50ohm load at the output of the coupling networkwhere the DUT is connected when testing mains supplylines.The CA EFT kit includes the load resistors and a set ofadapter to connect the coaxial matching resistorsappropriately to theDUT output port.
CA HFK KIT - VERIFICATION FOR CAPACITIVE COUPLINGCLAMP
The IEC/EN 61000-4-4 Ed 3.0 published 2012 recomendsthe calibration of the capacitive coupling clamp into a50ohm coaxial load.The capacitive coupling clamp (HFK) is connected to the50 ohm output of the EFT generator. A flexible insulatedplate inside the HFK is connected to a coaxial 50 ohmload resistor for verificate the EFT / Burst wave of thecapacitive coupling clamp.
www.emtest.com © EM TEST > PAGE 3/9
DATA SHEET > UCS 500N5T > 20151007
TECHNICAL DETAILS
MODEL OVERVIEW
UCS 500N5T SERIES
UCS 500N5T AC: 300 V / 16 A; 50/60 HzDC: 300 V / 16 A
UCS 500N5.1T AC: 300 V / 32 A; 50/60 HzDC: 300 V / 32 A
ELECTRICAL FAST TRANSIENTS
BURST MODULE, EFT/N5
As per IEC/EN 61000-4-4 and EN 61000-6-1, -6-2
Test voltage 200 V - 5,500 V ± 10%;100 V - 2,750 V ± 10% into 50 ohm
Pulse shape 5/50 ns into 50ohm and 1,000 ohm
Rise time tr 5 ns ± 30% into 50 ohm;5 ns ± 30% into 1,000 ohm
Pulse width td 50 ns ± 30% into 50 ohm;50 ns -15/+100 ns into 1,000 ohm
Source impedance 50 ohm
Polarity Positive/negative
TRIGGER CIRCUIT
Trigger of bursts Automatic, manual, external
Synchronization 0° - 360°, resolution 1° (16 - 500 Hz)
Burst duration td = 0.10 ms - 999 ms
Repetition rate tr = 10 ms - 9,999 ms
Spike frequency f = 0.1 kHz - 1,000 kHz
Test duration T = 0:01 min - 99:59 minT > 99:59 min --> endless
OUTPUTS
Direct Via 50 ohm coaxial connector
Coupling mode L, N, PE; all combinations
CRO trigger 5 V trigger signal for oscilloscope
ELECTRICAL FAST TRANSIENTS
TEST ROUTINES
Quick Start On-line adjustable parameters,easy-to-use
Standard Testroutines
As per IEC/EN 61000-4-4, Levels 1 -4As per IEC/EN 61000-6-1, -6-2Manual Standard Test routine
User Test routines Synchronous burst releaseRandom burst releaseChange voltage after TFrequency sweep within one burstFrequency sweep with constantnumber of pulsesFrequency sweep with constant burst durationChange polarity after T
OPTIONS
HFK Capacitive coupling clamp as per IEC/EN 61000-4-4
KW50 100:1 divider, 50ohm
KW1000 500:1 divider, 1,000 ohm
CA EFT kit Kit for burst pulse verificationconsisting of KW 50, KW 1000 andadapter for DUT port in a plastic casefor storage
CA HFK kit Adapter set for capacitive couplingclamp calibration included:- Transducer plate as per IEC/EN61000-4-4 Ed 3.0- Support for positioning the KW 50adapter on 100mm height as thecapacitive coupling clamp
CA MC F Adapter to match KW 50 loadresistor to the EUT supply of3-phaseN-series coupling network
A6dB 6 dB attenuator, 50 ohm
ITP Immunity test probes (electrical fieldgeneration)
ITP/H Immunity test probe (magnetic fieldgeneration)
www.emtest.com © EM TEST > PAGE 4/9
DATA SHEET > UCS 500N5T > 20151007
TECHNICAL DETAILS
COMBINATION WAVE / SURGE
SURGE MODULE, VCS/N5
As per IEC/EN 61000-4-5 and IEC/EN 61000-6-1, -6-2
Voltage (o.c.) 160 V - 5,000 V ± 10%
Pulse front time 1.2 us ± 30%
Pulse time to halfvalue
50 us ± 20%
Current (s.c.) Max. 2,500 A ± 10%
Pulse front time 8 us ± 20%
Pulse time to halfvalue
20 us ± 20%
Polarity Positive/negative/alternating
Event counter 1 - 30,000 or endless, selectable
TRIGGER CIRCUIT
Release of pulses Automatic, manual, external
Synchronization 0° - 360°, resolution 1°
Repetition rate max. 1 Hz (1 s - 999 s)
OUTPUTS
Direct Via HV connectors for externalcoupling networks (Zi = 2 ohm with optional adapterIMN 2)
Coupling mode Line to lineLine(s) to ground
CRO trigger 5 V trigger signal for oscilloscope
MEASUREMENTS
CRO Û-monitor 10 Vp at 5,00 0V
CRO Î-monitor 10 Vp at 2,500 A
Peak voltage 5,000 V in the LCD display
Peak current 2,500 A in the LCD display
COMBINATION WAVE / SURGE
TEST ROUTINES
Quick Start One-line adjustable parameters,easy-to-use
Standard Testroutines
As per IEC/EN 61000-4-5, Levels 1 -4As per IEC/EN 61000-6-1, -6-2Manual Standard Test routine
User Test routines Change polarity after n pulsesChange coupling after n pulsesChange voltage after n pulsesChange phase angle after n pulses
Pulsed MagneticField
as per IEC/EN 61000-4-9Test levels 100, 300 and 1,000A/mTest level steplessly adjustableunder Quick Start
OPTIONS
CNV504Nx Coupling network for 4 signal/datalines as per IEC/EN 61000-4-5 Ed 3.0
CNV508Nx Coupling network for 8 signal/datalines as per IEC/EN 61000-4-5 Ed 3.0
CNI 508N2Assembly
Set of coupling/decoupling andprotection networks for testingunshielded and shielded high-speedcommunication lines (Ethernet lines)
IMN 2 Impedance matching adapter tomatch direct output to 2 ohm sourceimpedance
www.emtest.com © EM TEST > PAGE 5/9
DATA SHEET > UCS 500N5T > 20151007
TECHNICAL DETAILS
POWER FAIL, DIPS & INTER-RUPTIONS, VOLTAGE VARIATIONS
POWER FAIL MODULE, PFS/N5
As per EN/IEC 61000-4-11, IEC/EN 61000-4-29 and IEC/EN 61000-6-1, -6-2
UCS 500N5TChannel PF1/PF2
AC voltage: max. 30 0VAC current: max. 16 ADC voltage: max. 30 0VDC current: max. 16 A
UCS 500N5.1TChannel PF1/PF2
AC voltage: max. 300 VAC current: max. 32 ADC voltage: max. 300 VDC current: max. 32 A
Frequency 16 Hz - 500 Hz and DC
Switching time < 5 us into a 100 ohm resistive load
Inrush current > 500 A
Protection Both channels are protected againstshort-circuit conditions.
TRIGGER CIRCUIT
Trigger of events Automatic, manual, external
Synchronization 0° - 360°, resolution 1° (16 - 500 Hz)
Repetition rate 10 ms - 9,999 s
Event duration 20 us - 9,999 s
OUTPUTS
DUT terminals L, N and PE
CRO trigger 5 V trigger signal for oscilloscope
MEASUREMENTS
DUT voltage In the LCD display
DUT current In the LCD display
MON V Measurement of the DUT voltage;built-in 100:1 divider
MON I Measurement of the DUT current; 10mV/A; max. 1,000 A
POWER FAIL, DIPS & INTER-RUPTIONS, VOLTAGE VARIATIONS
TEST ROUTINES
Quick Start On-line adjustable parameters,easy-to-use
Standard Testroutines
As per IEC/EN 61000-4-11 for AC suppliesAs per IEC/EN 61000-4-29 for DCsuppliesAs per EN 61000-6-1, -6-2Manual Standard Test routine
User Test routines Voltage variation, control of anexternal variacChange phase angle after n eventsChange event duration after neventsInverse mode
50/60Hz magneticfield
As per IEC/EN 61000-4-8Test levels 1, 3, 10 and 30A/m withexternal current transformer MC2630Test levels 100, 300 and 1,000 A/mwith external current transformer MC26100
OPTIONS
V 4780 Tapped autotransformer as perIEC/EN 61000-4-11 Ed.2
V 4780 S2 Tapped autotransformer as perIEC/EN 61000-4-11 Ed.2 withautomatic change of tap
MV 2616 Motorised variac (0 - 260 V, 16 A)
MV 2632 Motorised variac (0 - 260 V, 32 A)
MS 100N Magnetic field coil, 1 m x 1 m
MC 2630 Current transformer for magneticfields up to 30 A/m
MC 26100 Current transformer for magneticfields up to 1,000 A/m
CA PFS Calibration box for inrush currentverification as per IEC/EN61000-4-11
www.emtest.com © EM TEST > PAGE 6/9
DATA SHEET > UCS 500N5T > 20151007
TECHNICAL DETAILS
TELECOM SURGE
TSURGE MODULE, TSURGE5
Test voltage 160 V - 5,000 V ± 10%
Energy storagecapacitor
20 uF
Polarity Positive, negative, alternating
Counter 1 - 30,000 or endless, selctable
As per ITU and ETSIrecommendations
Front time 10 us ± 30%
Pulse duration 700 us ± 20%
As per FCC part 68, Pulse B
Front time 9 us ± 30%
Pulse duration 720 us ± 20%
Output current@25 ohm output
4 - 125 A (short-circuit)
Rise time 5 us ± 30%
Pulse duration 320 us ± 20%
As per IEC/EN 61000-4-5
Rise time 10 us ± 30%
Pulse duration 700 us ± 20%
Output current@25 ohm output
4 A - 125 A (short-circuit)
Rise time 5 us ± 20%
Pulse duration 320 us ± 20%
TELECOM SURGE
TRIGGER CIRCUIT
Trigger of events Automatic, manual, external
Repetition rate max. 0.5 Hz (2 s - 999 s)
OUTPUTS
As per ITU For 2-wire T1/T2 with 25 ohm each
As per FCC part 68 For 2-wire T1/T2 with 25 ohm each
As per IEC61000-4-5 Ed 3.0
For 4-wire T1,T2,T3,T4 with 25 ohmeach
For other requirements specialoutput configurations are available
OPTIONS
CNV 504T5 Coupling/decoupling network forunshielded symmetrical lines(communication lines) as per IEC/EN61000-4-5 Ed.3 (fig. 10) for 4 lines.
CNV 508T5 Coupling/decoupling network forunshielded symmetrical lines(communication lines) as per IEC/EN61000-4-5 Ed.3 (fig. 10) for 8 lines.
www.emtest.com © EM TEST > PAGE 7/9
DATA SHEET > UCS 500N5T > 20151007
TECHNICAL DETAILS
GENERAL DATA
INTERFACES
Serial interface USB
Parallel interface IEEE 488, addresses 1 - 30
Analog output 0 - 10 VDC to control an externaltransformer
CN interface 15pin SubD connector to control anexternal coupling network
Fail inputs DUT monitoring via Fail1 and Fail2input (one each)
DIMENSIONS
Dimensions 19", 6HU, (with TSurge5 module)
Weight approx. 35 kg
MAINS
Supply voltage 115V/230 VAC +10%/-15%
Power approx. 75 W
Frequency 50/60 Hz
Fuses 2 x 2 AT (230 V) or 2 x 4 AT (115 V)
SAFETY
Safety standard IEC/EN 61010
Security circuit Control input (24 VDC)
Warning lamp Floating contact (max. 230 V/6 A)
GENERAL DATA
ACCESSORIES INCLUDED
Mains supply Plug depends on the country of use
DUT supply Plug depends on the country of use
DUT adapter Socket depends on the country ofuse
Operation manual, Calibration certificate, iec.control remote control software
OPTIONS
CNI 503Ax 3-phase coupling/decouplingnetworks as per IEC/EN 61000-4-4and -4-5 up to 200 A per phase
iec.control 1 Remote control and documentationsoftware, including standard testroutines and reporting capabilities.
www.emtest.com © EM TEST > PAGE 8/9
DATA SHEET > UCS 500N5T > 20151007
COMPETENCE WHEREVERYOU ARE
CONTACT EM TEST DIRECTLY
SwitzerlandEM TEST (Switzerland) GmbH > Sternenhofstraße 15 > 4153 Reinach >SwitzerlandPhone +41 (0)61/7179191 > Fax +41 (0)61/7179199Internet: www.emtest.ch > E-mail: [email protected]
GermanyAMETEK CTS Germany GmbH > Lünener Straße 211 > 59174 Kamen >DeutschlandPhone +49 (0)2307/26070-0 > Fax +49 (0)2307/17050Internet: www.emtest.com > E-mail: [email protected]
FranceEM TEST FRANCE > Le Trident - Parc des Collines > Immeuble B1 - Etage 3 > 36, rue Paul Cézanne > 68200 Mulhouse > FrancePhone +33 (0)389 31 23 50 > Fax +33 (0)389 31 23 55Internet: www.emtest.fr > E-mail: [email protected]
PolandEM TEST Polska > ul. Ogrodowa 31/35, 00-893 Warszawa > Polska Phone +48 (0)518 64 35 12Internet: www.emtest.com/pl > E-mail: [email protected]
USA / CanadaAMETEK Compliance Test Solutions > 52 Mayfield Ave. > Edison > NJ 08837Phone +1 (732) 417-0501Internet: www.emtest.com > E-mail: [email protected]
P.R. ChinaE & S Test Technology Limited > Rm 913, Leftbank > No. 68 Bei Si Huan Xi Lu > Haidian District > Beijing 100080 > P.R. ChinaPhone +86 (0)10 82 67 60 27 > Fax +86 (0)10 82 67 62 38Internet: www.emtest.com > E-mail: [email protected]
Republic of KoreaEM TEST Korea Limited > #405 > WooYeon Plaza > #986-8 > YoungDeok-dong >Giheung-gu > Yongin-si > Gyeonggi-do > KoreaPhone +82 (31) 216 8616 > Fax +82 (31) 216 8616Internet: www.emtest.co.kr > E-mail: [email protected]
Information about scope of delivery, visual design and technical data correspond with the state of development at time of release. Subject tochange without further notice.
www.emtest.com © EM TEST > PAGE 9/9