ul listed cdma & hspa+ cellular communication for fire ...ul listed cdma & hspa+ cellular...

4
Search dmpalarms UL Listed CDMA & HSPA+ Cellular Communication for Fire Alarm Control Panels DIGITAL CELLULAR FIRE COMMUNICATORS FEATURES • 263C/263H enhances system security that conforms with NFPA and UL requirements • Direct reporting to the DMP Central Station receiver, with no relaying of alarm signals • Fire Slave Input option of the XR150/XR550 with 263C/263H approved for any FACP • Modular solution means easily updated for newer technologies • Eight-path redundancy with multiple message delivery available • DMP Adaptive Technology™ switches communication paths while maintaining supervision if the current path becomes unavailable The 263C/263H, when installed with a DMP XR150/XR150FC or XR550/XR550FC Panel, is UL approved as a primary (standalone) fire communicator with no backup, and is approved as a fire slave communicator, compatible with any FACP. The 263C/263H provides a dependable communications link between your alarm system panel and Central Station. • Compared to a dialup communication link, cellular can save significantly in annual telecommunication costs • UL Listed as the Primary Communicator and Fire Slave Input for the XR150/XR550 in Fire Applications under ANSI/UL 864 Commercial Fire (Meets NFPA 72) • Works on digital cellular data networks over a variety of carriers • 263C/263H uses power from panel with low current draw for long standby battery life • Can be equipped with local or remote antenna, offering more flexibility when installing • Ability to check signal strength indication at the keypad • Messaging features transmit alarms/alerts to users via SMS text messages, and allow users to remotely control their panel via text commands XR550FC with 263C Cellular Communicator

Upload: others

Post on 20-Mar-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: UL Listed CDMA & HSPA+ Cellular Communication for Fire ...UL Listed CDMA & HSPA+ Cellular Communication for Fire Alarm Control Panels Digital Cellular Fire CommuniCators Features •

Search dmpalarms

UL Listed CDMA & HSPA+ Cellular Communication for Fire Alarm Control Panels

Digital Cellular Fire CommuniCators Features• 263C/263HenhancessystemsecuritythatconformswithNFPAandULrequirements

• DirectreportingtotheDMPCentralStationreceiver,withnorelayingofalarmsignals

• FireSlaveInputoptionoftheXR150/XR550with263C/263HapprovedforanyFACP

•Modularsolutionmeanseasilyupdatedfornewertechnologies

• Eight-pathredundancywithmultiplemessagedeliveryavailable

• DMPAdaptiveTechnology™switchescommunicationpathswhilemaintainingsupervisionifthecurrentpathbecomesunavailable

The263C/263H,wheninstalledwithaDMPXR150/XR150FCorXR550/XR550FCPanel,isULapprovedasaprimary(standalone)firecommunicatorwithnobackup,andisapprovedasafireslavecommunicator,compatiblewithanyFACP.The263C/263HprovidesadependablecommunicationslinkbetweenyouralarmsystempanelandCentralStation.

• Comparedtoadialupcommunicationlink,cellularcansavesignificantlyinannualtelecommunicationcosts

• ULListedasthePrimaryCommunicatorandFireSlaveInputfortheXR150/XR550inFireApplicationsunderANSI/UL864CommercialFire(MeetsNFPA72)

•Worksondigitalcellulardatanetworksoveravarietyofcarriers

• 263C/263Husespowerfrompanelwithlowcurrentdrawforlongstandbybatterylife

• Canbeequippedwithlocalorremoteantenna,offeringmoreflexibilitywheninstalling

• Abilitytochecksignalstrengthindicationatthekeypad•Messagingfeaturestransmitalarms/alertstousersviaSMStextmessages,andallowuserstoremotelycontroltheirpanelviatextcommands

XR550FCwith263CCellularCommunicator

Page 2: UL Listed CDMA & HSPA+ Cellular Communication for Fire ...UL Listed CDMA & HSPA+ Cellular Communication for Fire Alarm Control Panels Digital Cellular Fire CommuniCators Features •

Intrusion | Fire | Access | Network | Cellular

463G

Fully superviseDYou’re kept fully informed of systemstatus. The unit sends full reportingmessages including Zones, Areas,andUsers,withallnamesanddetailsincluded.Fullsupervisionensuresthatthe cellular communication path isintactandfunctional.

eigHt-patH reDunDanCy Feelmore secure with up to eightpaths of communication redundancy.Select fromTCP,UDP,CDMA,HSPA+,Single LineDialer, Dual LineDialerwith mult iple IP numbers, andmultiple telephone numbers. Youidentifyandconfigureyour redundantcommunicationlinksviaRemoteLink.

ADACT(digitalalarmcommunicatortransmitter)systemmaybeconfiguredas:• Path1TypeDDPrimaryandPath2TypeDDBackup

• Path1TypeDDPrimaryandPath2TypeCELLBackup

• Path1TypeDDPrimaryandPath2TypeNETBackup

ANETorCELLsystemmaybeconfiguredas:• Path1TypeNETPrimarywithnoBackup

• Path1TypeCELLPrimarywithnoBackup

• Path1TypeNETPrimaryandPath2TypeDDBackup

• Path1TypeNETPrimaryandPath2TypeCELLBackup

• Path1TypeCELLPrimaryandPath2TypeNETBackup

DireCt reportingThe digital cellular communicatorstransmit IPdatapacketsdirectlyfromthepanel’sprocessoroverthewirelessdata network. All of themessagesthat are capableof beingsent by thecontrol panel are received directlyby theDMPCentral Station receiver.There are no intermediary serversornetworkoperationcenters, andnoretransmission or reinterpretation oftheinformation.Directreportingmeansfasterresponse,withnoconcernsaboutsignalsnot beingproperly relayedorintermediate communication linksfailing.

aDD-on to Xr150/Xr550 panel The263C/263Hworksasaneasy-to-install XR150/XR550 expansion card,withplug-and-playeaseofinstallation.No extra programming is required.It provides full data delivery of DMPZones,Areas,andUsers,withallnamesanddetailsincluded.The remarkably compact 263C/263Hwon’t take up a lot of space in yourcommunicationscloset.Theunitdirectlyinstallsinthepanelexpansioncardslot,whichismountedinsideasturdyUL-listedmetalcabinet.Tamperprotectionisalsoavailableforaddedsecurity.

ul listeDInstall the DMP 263C/263H DigitalCellular Communicator in anXR150/XR550 Series panel to create a ULlisted, primary communication pathfor commercial fire installations. TheFire Slave Input option of the XR550hasalsobeenapprovedunderANSI/UL864(NFPA722007&2010),allowingittobeusedasaSlaveCommunicatorforanyFACP.

aDaptive teCHnology™ If theprimary communicationpath iscompromisedorbecomesunavailable,Adaptive Technology almost instantlyswitchestoadesignatedbackuppath.Wheremultiplebackupsareavailable,communications canbeprogrammedtoswitchtoanotherpathasnecessary.Thecheckinfrequencyandprogrammingforabackuppathadapttothecheckinprogramming of the primary path.When the primary path becomesavailable,normalcommunicationsarerestored.AdaptiveTechnologyprovidesadditionalconfidenceintheintegrityofyoursystem,whileprotectingyoufromunexpectedcellularservicecharges.

reDuCeD eQuipment neeDsWithothercellularbackupequipment,you need to purchase additionalenclosures,powersupplies,batteries,cabling, andconduit connections. The263C/263Hreducesthenumberofpiecesof equipment you have to purchase.It comes ready tomount, reducingyour initial costsandsimplifyingbothinstallationandongoingoperation.

reDuCeD CommuniCation CostsAddingthecellularcommunicatortotheDMPXR150/XR550 fire alarm controlpanel can lower costs significantlycompared to dial-up connections.Fire systems typically require twodial-up lines that can be eliminatedand replacedwith a single cellularconnection.

slave CommuniCatorsXR150/XR550 panels operate asslave communicators via cellularcommunicaton in fire installationscompa t i b l e w i t h an FACP. I naddition to standard hardwire slavecommunications that connect viainputstotheDMPpanel,1103WirelessTransmitters can be installed tocommunicateFACPstatus.

antenna plaCementTheunitincludesbothlocalandremoteSMA(S-bandmultipleaccess)antennaconnections,givingyouaddedfreedomandflexibilityduringinstallation.

263H

Page 3: UL Listed CDMA & HSPA+ Cellular Communication for Fire ...UL Listed CDMA & HSPA+ Cellular Communication for Fire Alarm Control Panels Digital Cellular Fire CommuniCators Features •

Intrusion | Fire | Access | Network | Cellular

SPEC SHEET

low Current DrainWith its extremely low current drainand long standby battery life, the263C/263Hwill continue to provide acommunications link for anextendedperiod of time, even during a powerfailure.Itdrawshalfthecurrentofothercomparableunits.

simple to install anD programConnectthe263Cor263Htoyourpanel,attach the antenna and power, andinstallationiscomplete.Programmingthe 263C/263H is fast and simple,accomplishedwithinthepanelitself.After programming the 263C/263Hcellular communications path viaRemoteLink,youwillbepresentedwiththeActivateSIM/MEIDwindowtoactivateyour cellular plan. Once activated,the wireless backup connection isimmediately online protecting yourcommunications link. No separateprogrammingutilityisrequired.

seCureCom Cellular serviCesThe263HcomesstandardwithaSIM(SubscriberIdentityModule)cardreadyto useSecureComWirelessCellularService fromDMP.The263CdoesnotincludeaSIMCardandisactivatedwiththeMEIDnumber.Withthe263C/263HandSecureCom, youhaveaone-stopresourceforbothhardwareandcellularservice.

enHanCeD Fire proteCtionCompared to dial-up connections, adigital cellular communication linkprovidesgreater reliability, protectionfrom sabotage, and is less proneto being knocked out by weather.Unlikemobile cellular connections,the263C/263Hcreatesafixednetworkconnection thatminimizeshand-offsandthechancefordroppedconnections.Whentroubleconditionsoccur,theycanbemorequicklydiagnosedandoftencorrectedremotely.TheNFPA 72 code requires a test oftheentirecommunicationspatheveryfiveminutes. TheDMPModelXR150/XR550PanelusedwithDMP263C/263HDigital CellularCommunicatormeetsthis requirementwhen check-in andfail time settings are programmedfor fiveminutes. The net result is ahigher level of system reliability incomparisonwith traditional systemsthatrelyonredundantphonelinesandthesubstantiallylessfrequent24-hoursupervisionreportsassociatedwiththatapproach.

upDateableIn addition to being able to changecellular carriers, you will also beready to take advantage of technicalimprovementsastheyoccur.Theunit’smodulararchitectureenablesseamlessupgrades as improved technologybecomesavailable.

mobile platFormsDMPmobile platforms provide youwiththetoolsyouneed tobuild strong connectionswithyourcustomers.• MyAccess™enablesendusers tomonitor andmanage their systemsremotelyfromanymobilephoneusingsimpleSMStexting.• The Virtual Keypad™App puts akeypadon theuser’sApple iPhone®,iPad™,orAndroidcompatibledevices.Dealers can offer these much-appreciatedservicestotheircustomersand realize the benefits of additionalrecurringrevenue.

myaCCessYourcustomerscansendmanyofthemost commonsystemcommands totheirresidentialorcommercialsystemsviatextmessages.Theycanalsochoosetohavealertssent to themeachtimethere’s an arm/disarm, an alarm, orotherselectedevents.Alertscanbetransmittedbythepanelastextmessagestouptothreephones.UserscanalsouseMyAccesstointeractwithanyZ-WavedevicesprogrammedthroughtheirDMPpanel,enablingthemtocontrollights,thermostats,andmoreviatextcommands.

tHe virtual KeypaD appDealers can invite their customers tobegin using their APP to give themcontrol of their security system. TheVirtualKeypadallowsthemtoarmordisarm,andtocheckthestatusoftheircellularconnectedDMPsecuritysystemfromanywheretheyhavecellservice.TheycanalsoaccessanyZ-Wavehomecontrol devicesprogrammed throughtheirDMPpanelandDMPcameras.

UseanymodelofcellphoneforMessagingFeatures

Page 4: UL Listed CDMA & HSPA+ Cellular Communication for Fire ...UL Listed CDMA & HSPA+ Cellular Communication for Fire Alarm Control Panels Digital Cellular Fire CommuniCators Features •

© 2

014

Dig

ital M

onito

ring

Prod

ucts

, Inc

. |

LT-1

348

| 02/

14

Intrusion | Fire | Access | Network | Cellular 2500 North Partnership BoulevardSpringfield, Missouri 65803-8877

800.641.4282 | dmp.comDesigned, Engineered & Assembledin Springfield, Missouri

CDMA & HSPA+ Cellular Communicators

speCiFiCations PrimaryPower 12VDCfrompanel CurrentDraw(263C) Standby 13mA Alarm 13mA

CurrentDraw(263H) Standby 24mA Alarm 28mA

CompatibilityDMPXR150 |XR350 |XR550SeriesPanels (A381cable isrequiredfortheXR150|XR350|XR550Series)

orDering inFormation 263C CDMACellularCommunicator(Verizon) 263C/381-2 CDMACellularCommunicatorw/381-2 Cable(Verizon)

263H HSPA+CellularCommunicator (AT&T,T-Mobile,(263HCAN-Rogers))

263H/381-2 HSPA+CellularCommunicatorw/381-2 Cable(AT&T,T-Mobile,(263HCAN-Rogers))

aCCessories270 NetworkTransientSuppressor277 TroubleAnnunciator318 BatteryHarness381-2 18"CoaxExtension381-12 12'CoaxExtension381-25 25'CoaxExtension383 RubberDuckAntenna386 WallMountAntennaBracket387-1 3dBFiberglassAntennaw/bracket387-2 2dBAttackEnclosureAntenna387-3 3dBMEGAntenna387-25 SMATONCABLE,25FT,LMR195387-50 SMATONCABLE,50FT,LMR195866 StyleWNotificationCircuitModule893A DualPhoneLineModule

listings anD approvalsCaliforniaStateFireMarshal(CSFM)UnderwritersLaboratories(UL)ListedUnderwritersLaboratoriesCanada(ULC)Listed

Foradditionalapprovalinformation,accesswww.dmp.comandselectCompliance.

two-way CommuniCation Superior to tradit ional wirelessdevices that just broadcast until thezone is restored, DMP 1100 Seriesrequire an acknowledgement fromthe 1100 Series Receiver, indicatingsuccessfulcommunication.Thissmarttechnology ensures that each andevery communication is receivedandefficiently processed at the panel.With the 900MHz frequency-hoppingspread-spectrum technology, clearand accurate signal transmissionswithout interference inpracticallyanyenvironmentistobeexpected.

1100 series reCeivers The1100SeriesReceivers:1100Xand

1100XHallowyoutoaddup to 500 transmittersand is required forwireless capability inboth regularandharshenvironments.

1103 universal transmitter Model 1103Universal Transmitter istypically used in commercial fire orburglarydoor/windowapplications.Itoffers thesame lookand featuresasthe1101transmitter,withtheadditionofa470kend-of-lineresistorandwalltamperswitch.

1165/1165H/1165Hs CommerCial smoKe DeteCtors TheModel1165SmokeDetector,1165HSmoke/Heat Detector, and 1165HS

Smoke/HeatDetectorwith Sounder includea tamper switch thatsendsatroublesignalifthedetectorisremovedfrom the mountingbase.

1181 post inDiCator valve Themodel1181PIVisaweatherproofand tamper resistantwireless switchformonitoringtheopenpositionoffiresprinkler control values of the postindicator,butterflyandothertypes.

1182 os&y The1182OS&YSwitchisusedtomonitortheopenpositionof anOS&Y (OutsideScrewand Yoke) type gate valve. The1182mountsconvenientlytomostOS&Yvalvesranginginsizefrom½”to12”.Theswitchoperatestheexternalcontactsofthewirelesstransmitterwhenthevalvepositionisalteredfromanopenstate.

Dmp wireless DeviCes For ansi/ul 864 CommerCial FireCompleteyourfiresystemwithotherDMPwirelessdevicesthatareANSI/UL864ListedforFireProtectiveSignalingSystems.