Mining CablesMedium Voltage
®
Table of contents
®BiTmining NTSCGEWOEU .../3 ......................................................-W ®BiTmining NTSCGEWOEU-W .../3E......................................................®
BiTmining (N)TSKCGECWOEU-CH......................................................®
BiTmining (N)TSKCGECWOEU-FN......................................................®
BiTmining (N)TSCGEWOEU-F...............................................................®
BiTmining (N)TSCGEWOEU-R.............................................................. ®BiTmining (N)TSCGEWOEU-SR............................................................®BiTmining (N)TSCGEWOEU-TR............................................................
2
5
Technical data: Construction:
Application:
Chemical parameters:
Power supply cable for use strip and open-pit mining facilities designed for operation in water and exposed to high mechanical stresses, e.g. for connection to dredgers, floating docks, submersible pumps, etc. Cables are suitable to work in sewage, salt and brackish water.
Resistance to oil: EN 60811-2-1, IEC 60811-2-1Behaviour in case of fire: VDE 0482 Part 332-1-2, EN 60332-1-2, IEC 60332-1-2Water compatability: HD 22.16 (VDE 0282 Part 16)Weather resistance: Unrestricted use outdoors and indoors, resistant to ozone, UV and moisture
®BiTmining NTSCGEWOEU .../3-W Medium voltage, flexible power supply cable for use in water
Operating temperature:Fixed systems: -40°C to 90°CFlexible operation: -25°C to 80°CMaximum permissible water temperature: 40°CMaximum permissible operating temperature of the conductor: 90°CMaximum conductors operating temperature in short-circuit: 250°CTensile load: 15 N/mm²Torsional stresses: +/- 100°/mMin. bending radius: according to DIN VDE 0298, Part 3Operating voltage: U /U= 3,6/6 kV to 18/30 kV0
Test voltage: 11 kV to 43 kVStandard: according to DIN VDE 0250, p.813
Conductor: finely stranded class 5 (EN 60228, DIN VDE 0295) tinned, electrolytic copperInsulation: EPR compound with improved electrical and mechanical characteristics (DIN VDE 0207, Part 20) Arrangement of protective-earth conductor: protective-earth conductor split into 3 in the outer intersticesElectrical field control: Inner and outer semiconductive layer of semiconductive rubberCore colours: Natural colouring with black semiconductive rubber with printed white digits 1-3Core arrangement: Three main conductors laid-up with protective-earth conductor split into 3 in the outer intersticesWrapping: semiconductive, reinforced, swellable, binding and separating tapeInner sheath: EPR compound type GM1b, waterproof (acc. to DIN VDE 0201, Part 21)Outer sheath: 5GM5 compound with improved mechanical characteristics (acc. to DIN VDE 0207, Part 21), colour: red
®
Rated voltage U /U [kV]0
Maximum permissible operating voltage in AC systems U U [kV]/0
Maximum permissible operating voltage in DC systems U /U [kV]0
AC test voltage [kV]Current-carrying capacity According to DIN VDE 0298, Part 4
4,2/7,2
5,4/10,8
11
6,9/12
9/18
17
3,6/6 6/10 8,7/15 12/20 14/25 18/30
10,4/18
13,5/27
24
13,9/24
18/36
29
17,3/30
22,5/45
36
20,8/36
27/54
43
PN-EN60332-1industrial applications
mining applications
high flexibility
UV
UV resistance oil resistant mechanical resistance
oxygen index
>29
low operating temperature
explosion hazardous areas
a b cA B
2
Number of coresand nominalcross-section
2n x mm
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
Maximumpermissibletensile force
[N]
53,655,860,364,969,672,377,883,6
48,250,354,559,463,166,572,472,477,977,9
11251575225031504275540067508325
1125157522503150427554006750675083258325
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x50/3 3x150+3x70/3 3x185+3x50/3 3x185+3x95/3
0,7950,5650,3930,2770,2100,1640,1320,108
0,7950,5650,3930,2770,2100,1640,1320,1320,1080,108
0,390,370,350,330,320,310,300,29
0,370,350,330,310,300,290,280,280,280,28
0,250,280,310,340,390,420,460,48
0,310,350,390,430,490,530,580,580,620,62
139172215265319371428488
131162202250301352404404461461
3,04,36,18,5
11,614,618,322,6
3,04,36,18,5
11,614,618,318,322,622,6
386042605100630076508600
1010011800
32503650440055706720775091009100
1070010800
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
Medium voltage, flexible power supply cable for use in water
®BiTmining NTSCGEWOEU .../3 -W 3,6/6kV
BiTmining NTSCGEWOEU .../3 ®-W 6/10kV
BiTmining NTSCGEWOEU .../3 ® -W 8,7/15kV
®
45,848,052,457,161,864,370,175,8
11251575225031504275540067508325
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
0,7950,5650,3930,2770,2100,1640,1320,108
0,360,340,320,310,290,280,280,27
0,340,380,440,480,540,590,640,69
131162202250301352404461
3,04,36,18,5
11,614,618,322,6
3050340041505300655074508750
10450
®BiTmining NTSCGEWOEU-W .../3
3
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
71,573,677,982,886,589,895,8
101,3
11251575225031504275540067508325
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
0,7950,5650,3930,2770,2100,1640,1320,108
0,450,430,410,390,370,350,340,33
0,170,190,210,230,250,270,300,31
139172215265319371428488
3,04,36,18,5
11,614,618,322,6
6220669076609100
10400116001325015200
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
58,061,165,470,273,977,383,288,6
11251575225031504275540067508325
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
0,7950,5650,3930,2770,2100,1640,1320,108
0,410,390,370,350,330,320,310,30
0,220,240,270,300,330,360,390,41
139172215265319371428488
3,04,36,18,5
11,614,618,322,6
436049005770705083009370
1090012650
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
65,467,572,076,681,383,989,695,4
11251575225031504275540067508325
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
0,7950,5650,3930,2770,2100,1640,1320,108
0,430,410,390,370,350,340,330,32
0,190,210,230,250,280,300,330,35
139172215265319371428488
3,04,36,18,5
11,614,618,322,6
53505780675080509500
105001205014000
Medium voltage, flexible power supply cable for use in water
Cable Factory BITNER reserve the right to modify specifications without prior notification.
*Cable outer diameter may differ from the one shown in table
Note: On customer's request other cross sections or number of cores can be produced
BiTmining NTSCGEWOEU .../3 ® -W 12/20kV
BiTmining NTSCGEWOEU .../3 ®-W 14/25kV
BiTmining NTSCGEWOEU .../3 ® -W 18/30kV
®
®BiTmining NTSCGEWOEU-W .../3
4
®BiTmining NTSCGEWOEU .../3E-W Medium voltage, flexible power supply cable for use in water
Technical data:
Operating temperature:Fixed systems: -40°C to 90°CFlexible operation: -25°C to 80°CMaximum permissible water temperature: 40°CMaximum permissible operating temperature of the conductor: 90°CMaximum conductors operating temperature in short-circuit: 250°CTensile load: 15 N/mm²Torsional stresses: +/- 25°/mMin. bending radius: according to DIN VDE 0298, Part 3Operating voltage: U /U= 3,6/6 kV to 18/30 kV0
Test voltage: 11 kV to 43 kVStandard: according to DIN VDE 0250, p.813
Construction:
Application:
Chemical parameters:
Power supply cable for use strip and open-pit mining facilities designed for operation in water and exposed to high mechanical stresses, e.g. for connection to dredgers, floating docks, submersible pumps, etc. Cables are suitable to work in sewage, salt and brackish water.
Resistance to oil: EN 60811-2-1, IEC 60811-2-1Behaviour in case of fire: VDE 0482 Part 332-1-2, EN 60332-1-2, IEC 60332-1-2Water compatability: HD 22.16 (VDE 0282 Part 16)Weather resistance: Unrestricted use outdoors and indoors, resistant to ozone, UV and moisture
Conductor: finely stranded class 5 (EN 60228, DIN VDE 0295) tinned, electrolytic copperInsulation: EPR compound with improved electrical and mechanical characteristics (DIN VDE 0207, Part 20)Arrangement of protective-earth conductor: Individual concentric protective-earth conductors distributed over the insulation of three power coresElectrical field control: Inner and outer layers of semiconductive rubber and individual concentric protective-earth conductorCore colours: Natural colouring with black semiconductive rubber with printed white digits 1-3Core arrangement: Three main conductors and protective-earth conductor split into 3 elements distributed concentrically over the insulation of three power conductors laid-up together Wrapping: semiconductive, reinforced, swellable, binding and separating tapeInner sheath: EPR compound type GM1b, waterproof (acc. to DIN VDE 0201, Part 21)Outer sheath: 5GM5 compound with improved mechanical characteristics (acc. to DIN VDE 0207, Part 21), colour: red
Rated voltage U /U [kV]0
Maximum permissible operating voltage in AC systems U U [kV]/0
Maximum permissible operating voltage in DC systems U /U [kV]0
AC test voltage [kV]Current-carrying capacity According to DIN VDE 0298, Part 4
4,2/7,2
5,4/10,8
11
6,9/12
9/18
17
3,6/6 6/10 8,7/15 12/20 14/25 18/30
10,4/18
13,5/27
24
13,9/24
18/36
29
17,3/30
22,5/45
36
20,8/36
27/54
43
®
PN-EN60332-1industrial applications
mining applications
high flexibility
UV
UV resistance oil resistant mechanical resistance
oxygen index
>29
low operating temperature
explosion hazardous areas
a b cA B
5
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
50,154,157,561,467,370,377,181,8
11251575225031504275540067508325
3x25+3x16/3E3x35+3x16/3E3x50+3x25/3E3x70+3x35/3E3x95+3x50/3E
3x120+3x70/3E 3x150+3x70/3E3x185+3x95/3E
BiTmining ®
-W NTSCGEWOEU .../3E 6/10kV
0,7950,5650,3930,2770,2100,1640,1320,108
0,370,350,330,310,300,290,280,28
0,310,340,380,430,480,540,580,61
131162202250301352404461
3,04,36,18,5
11,614,618,322,6
338039804770583072508460
1000011800
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
48,951,056,260,166,067,074,080,5
11251575225031504275540067508325
3x25+3x16/3E3x35+3x16/3E3x50+3x25/3E3x70+3x35/3E3x95+3x50/3E
3x120+3x70/3E 3x150+3x70/3E3x185+3x95/3E
® BiTmining NTSCGEWOEU .../3E 3,6/6kV-W
0,7950,5650,3930,2770,2100,1640,1320,108
0,360,340,320,310,290,280,280,27
0,340,380,440,480,540,590,640,69
131162202250301352404461
3,04,36,18,5
11,614,618,322,6
3250363046205660707082709500
11580
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
56,758,862,367,972,076,981,888,3
11251575225031504275540067508325
3x25+3x16/3E3x35+3x16/3E3x50+3x25/3E3x70+3x35/3E3x95+3x50/3E
3x120+3x70/3E 3x150+3x70/3E3x185+3x95/3E
BiTmining ® NTSCGEWOEU-W .../3E 8,7/15kV
0,7950,5650,3930,2770,2100,1640,1320,108
0,390,370,350,330,320,310,300,29
0,250,280,310,340,390,420,460,48
139172215265319371428488
3,04,36,18,5
11,614,618,322,6
413045505355673079509470
1078012980
Medium voltage, flexible power supply cable for use in water
®
®BiTmining NTSCGEWOEU-W .../3E
6
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining ® NTSCGEWOEU-W .../3E 18/30kV
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
11251575225031504275540067508325
3x25+3x16/3E3x35+3x16/3E3x50+3x25/3E3x70+3x35/3E3x95+3x50/3E
3x120+3x70/3E 3x150+3x70/3E 3x185+3x95/3E
BiTmining ®
NTSCGEWOEU-W .../3E 12/20kV
0,7950,5650,3930,2770,2100,1640,1320,108
0,410,390,370,350,330,320,310,30
0,220,240,270,300,330,360,390,41
139172215265319371428488
3,04,36,18,5
11,614,618,322,6
46505340620073408900
102001155013800
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
68,370,573,979,683,788,693,598,2
61,065,068,472,378,281,286,192,6
11251575225031504275540067508325
3x25+3x16/3E3x35+3x16/3E3x50+3x25/3E3x70+3x35/3E3x95+3x50/3E
3x120+3x70/3E 3x150+3x70/3E3x185+3x95/3E
BiTmining ® NTSCGEWOEU-W .../3E 14/25kV
0,7950,5650,3930,2770,2100,1640,1320,108
0,430,410,390,370,350,340,330,32
0,190,210,230,250,280,300,330,35
139172215265319371428488
3,04,36,18,5
11,614,618,322,6
56506120705085209850
115001295014900
Medium voltage, flexible power supply cable for use in water
73,577,580,984,890,793,7
100,5105,2
11251575225031504275540067508325
3x25+3x16/3E3x35+3x16/3E3x50+3x25/3E3x70+3x35/3E3x95+3x50/3E
3x120+3x70/3E 3x150+3x70/3E3x185+3x95/3E
0,7950,5650,3930,2770,2100,1640,1320,108
0,450,430,410,390,370,350,340,33
0,170,190,210,230,250,270,300,31
139172215265319371428488
3,04,36,18,5
11,614,618,322,6
6420722081709400
11120124601435016400
®
Cable Factory BITNER reserve the right to modify specifications without prior notification.
*Cable outer diameter may differ from the one shown in table
Note: On customer's request other cross sections or number of cores can be produced
®BiTmining NTSCGEWOEU-W .../3E
7
Technical data: Construction:
Application:
Chemical parameters:
Flexible power supply cable for use in underground mining facilities for mobile machines like coal cutters etc. Designed for use in cable chains trailed behind the machines. Chains have protective function and absorb the tensile forces occuring during operation.
Resistance to oil: EN 60811-2-1, IEC 60811-2-1Behaviour in case of fire: VDE 0482 Part 332-1-2, EN 60332-1-2, IEC 60332-1-2Weather resistance: Unrestricted use indoors, outdoors, resistance to ozone, UV and moisture
BiTmining (N)TSKCGECWOEU®-CH
Medium voltage, flexible power supply coal cutter cable for chain operation
Fixed systems: -40°C to 90°C Flexible operation: -25 °C to 80 °C Maximum permissible operating temperature of the conductor: 90°CMaximum conductors operating temperature in short-circuit: 250°C
2Tensile load: 15 N/mm Min. bending radius: acc. to DIN VDE 0298,
2Part 3, or 2.3x D with tensile load limited to 5 N/mmMinimum distance with S-type directional changes: 20 x DOperating voltage: U /U= 3,6/6 kV 0
Test voltage: 11 kV Standard: based on DIN VDE 0250, p.813
Conductor: finely stranded class 6 (EN 60228, DIN VDE 0295) tinned, electrolytic copperControl/protective conductor: spirally applied concentric CuSn wires forming control conductors around support element, EPR insulation and spirally applied concentric CuSn wires to form protective conductor Insulation: EPR compound with improved electrical and mechanical characteristics (DIN VDE 0207, Part 20)Electrical field control: inner and outer layers of semiconductive rubberCore identification: Natural colouring with black semiconductive rubber with printed white digits 1-3Core arrangement: Three power conductors laid-up with double concentric control/protective conductor elements in the outer interstices, with optimised lay lengthInner sheath: GM1b (acc. to DIN VDE 0207, Part 21)Signal/monitoring conductor: spirally applied FeZn and CuSn wires in a vulcanized bond between inner and outer sheath.Outer sheath: 5GM5 compound with improved mechanical characteristics (acc. to DIN VDE 0207, Part 21), colour: red
®
Rated voltage U /U [kV]0
Maximum permissible operating voltage in AC systems U U [kV]/0
Maximum permissible operating voltage in DC systems U /U [kV]0
AC test voltage [kV]Current-carrying capacity According to DIN VDE 0298, Part 4
4,2/7,2
5,4/10,8
11
3,6/6
PN-EN60332-1industrial applications
mining applications
high flexibility
UV
UV resistance oil resistant mechanical resistance
oxygen index
>29
low operating temperature
explosion hazardous areas
a b cA B
power chains
8
Number of coresand nominalcross-section
2n x mm
Overallcable
diameter*[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
56,660,964,067,071,3
15752250315042755400
3x35+3x(1,5ST KON+25/3KON) + 6ÜL KON)3x50+3x(1,5ST KON+25/3KON) + 6ÜL KON)3x70+3x(1,5ST KON+35/3KON) + 6ÜL KON)3x95+3x(1,5ST KON+50/3KON) + 6ÜL KON)3x120+3x(1,5ST KON+70/3KON) + 6ÜL KON)
® BiTmining (N)TSKCGECWOEU -CH 3,6/6kV
0,5540,3860,2720,2060,164
0,310,300,290,280,27
0,380,430,490,550,60
162202250301352
4,36,18,511,614,6
47106060664081609700
Medium voltage, flexible power supply coal cutter cable for chain operation
®
®BiTmining (N)TSKCGECWOEU-CH
Cable Factory BITNER reserve the right to modify specifications without prior notification.
*Cable outer diameter may differ from the one shown in table
Note: On customer's request other cross sections or number of cores can be produced
9
Technical data: Construction:
Application:
Chemical parameters:
Flexible power supply cable for use in underground mining facilities especially for festoon systems
Resistance to oil: EN 60811-2-1, IEC 60811-2-1Behaviour in case of fire: VDE 0482 Part 332-1-2, EN 60332-1-2, IEC 60332-1-2Weather resistance: Unrestricted use indoors, outdoors, resistance to ozone, UV and moisture
BiTmining (N)TSKCGECWOEU® -FN
Medium voltage, flexible power supply cable for underground festoon systems
Operating temperature:Fixed systems: -40°C to 90°C Flexible operation: -25°C to 80 °C Maximum permissible operating temperature of the conductor: 90°CMaximum conductors operating temperature in short-circuit: 250°C
2 Tensile load: 15 N/mm Min. bending radius: acc. to DIN VDE 0298, Part 3Operating voltage: U /U= 3,6/6 kV0
Test voltage: 11 kVStandard: based on DIN VDE 0250 p.813
Conductor: finely stranded class 5 (EN 60228, DIN VDE 0295) tinned, electrolytic copperControl/protective conductor: spirally applied concentric CuSn wires forming control conductors around support element, EPR insulation and spirally applied concentric CuSn wires to form protective conductor Insulation: EPR compound with improved electrical and mechanical characteristics (DIN VDE 0207, Part 20)Electrical field control: inner and outer layers of semiconductive rubberCore identification: Natural colouring with black semiconductive rubber with printed white digits 1-3Core arrangement: Three power conductors laid-up with double concentric control/protective conductor elements in the outer interstices, with optimised lay lengthInner sheath: GM1b (acc. to DIN VDE 0207, Part 21)Signal/monitoring conductor: spirally applied FeZn and CuSn wires in a vulcanized bond between inner and outer sheath.Outer sheath: 5GM5 compound with improved mechanical characteristics (acc. to DIN VDE 0207, Part 21), colour: red
®
Rated voltage U /U [kV]0
Maximum permissible operating voltage in AC systems U U [kV]/0
Maximum permissible operating voltage in DC systems U /U [kV]0
AC test voltage [kV]Current-carrying capacity According to DIN VDE 0298, Part 4
4,2/7,2
5,4/10,8
11
3,6/6
PN-EN60332-1industrial applications
mining applications
high flexibility
UV
UV resistance oil resistant mechanical resistance
oxygen index
>29
low operating temperature
explosion hazardous areas
a b cA B
10
®BiTmining (N)TSKCGECWOEU-FNMedium voltage, flexible power supply cable for underground festoon systems
Number of coresand nominalcross-section
2n x mm
Overallcable
diameter*[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
50,154,558,565,068,2
15752250315042755400
3x35+3x(1,5ST KON+3x25/3KON) + 6ÜL KON3x50+3x(1,5ST KON+3x25/3KON) + 6ÜL KON3x70+3x(1,5ST KON+3x35/3KON) + 6ÜL KON3x95+3x(1,5ST KON+3x50/3KON) + 6ÜL KON3x120+3x(1,5ST KON+3x70/3KON) + 6ÜL KON
® BiTmining (N)TSKCGECWOEU -FN 3,6/6kV
0,5540,3860,2720,2060,164
0,300,290,280,270,26
0,280,330,370,420,46
162202250301352
4,36,18,511,614,6
41205000606073108670
®
Cable Factory BITNER reserve the right to modify specifications without prior notification.
*Cable outer diameter may differ from the one shown in table
Note: On customer's request other cross sections or number of cores can be produced
11
Technical data: Construction:
Operating temperature:Fixed systems: -40°C to 90°CFlexible operation: -25 °C to 80 °CMaximum permissible water temperature: 40°C Maximum permissible operating temperature of the conductor: 90°CMaximum conductors operating temperature in short-circuit: 250°C
2Tensile load: 15 N/mmTorsional stresses: +/-100°/mMin. bending radius: acc. to DIN VDE 0298, Part 3Travel speed on rewinding: up to 100m/minOperating voltage: U /U= 3,6/6 kV to 18/30 kV0
Test voltage: 11 kV to 43 kVStandard: based on DIN VDE 0250 p.813
Application:Flexible power supply cable for fixed installations in strip and open-pit mining facilities, alongside belt conveyors also for continuous slight movements (free overhang, slight twisting). Can also be used as connection cable between upper and lower part of excavator, stacker/reclaimer. It is suitable also for constant operation in water as power supply cable to submersible pumps.
Chemical parameters:Resistance to oil: EN 60811-2-1, IEC 60811-2-1Behaviour in case of fire: VDE 0482 Part 332-1-2, EN 60332-1-2, IEC 60332-1-2Water compatability: HD 22.16 (VDE 0282 Part 16)Weather resistance: Unrestricted use indoors, outdoors, resistance to ozone, UV and moisture
Conductor: finely stranded class 5 (EN 60228, DIN VDE 0295) not tinned, electrolytic copperInsulation: EPR compound with improved electrical and mechanical characteristics (DIN VDE 0207, Part 20)Electrical field control: inner and outer layers of semiconductive rubberCore identification: Natural colouring with black semiconductive rubber and printed white digits 1 to 3Core arrangement: Three main conductors laid-up with protective-earth conductor split into 3 in the outer intersticesInner sheath: special EPR compound (acc. to DIN VDE 0207, Part 21)Outer sheath: 5GM5 compound with improved mechanical characteristics (acc. to DIN VDE 0207, Part 21), waterproof, colour: red
®BiTmining (N)TSCGEWOEU -F Medium voltage, flexible power supply cable for fixed installations
®
Rated voltage U /U [kV]0
Maximum permissible operating voltage in AC systems U U [kV]/0
Maximum permissible operating voltage in DC systems U /U [kV]0
AC test voltage [kV]Current-carrying capacity According to DIN VDE 0298, Part 4
4,2/7,2
5,4/10,8
11
6,9/12
9/18
17
3,6/6 6/10 8,7/15 12/20 14/25 18/30
10,4/18
13,5/27
24
13,9/24
18/36
29
17,3/30
22,5/45
36
20,8/36
27/54
43
PN-EN60332-1industrial applications
mining applications
high flexibility
UV
UV resistance oil resistant mechanical resistance
oxygen index
>29
low operating temperature
explosion hazardous areas
a b cA B
12
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (®
-FN)TSCGEWOEU 8,7/15kV
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
®BiTmining (N)TSCGEWOEU 3,6/6kV-F
Medium voltage, flexible power supply cable for fixed installations
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (® -FN)TSCGEWOEU 6/10kV
3x25+3x25/33x25+3x50/33x35+3x25/33x35+3x50/33x50+3x25/33x50+3x50/33x70+3x35/33x70+3x50/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
41,943,644,046,247,547,553,153,155,858,466,170,877,682,5
0,7800,7800,5540,5540,3860,3860,2720,2720,2060,1610,1290,1060,0800,004
0,340,360,320,340,300,300,290,290,280,270,260,260,250,24
0,400,400,450,450,510,510,570,570,650,710,780,830,951,04
131131162162202202250250301352404462540620
3,583,585,015,017,157,15
10,0110,0113,6017,1621,4526,4634,3242,90
271632203065362536904040491551405900676083209830
1227614666
112511251575157522502250315031504275540067508325
1080013500
45,346,247,547,550,950,956,656,659,263,169,674,381,086,0
3x25+3x25/33x25+3x50/33x35+3x25/33x35+3x50/33x50+3x25/33x50+3x50/33x70+3x35/33x70+3x50/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
0,7800,7800,5540,5540,3860,3860,2720,2720,2060,1610,1290,1060,0800,004
0,360,380,340,340,320,320,310,310,290,280,280,270,260,25
0,320,320,360,360,410,410,450,450,510,560,600,650,730,80
139139172172215215265265319371428488574665
3,583,585,015,017,157,15
10,0110,0113,6017,1621,4526,4634,3242,90
30,403470340037554060440053205545632573808820
103651286015290
112511251575157522502250315031504275540067508325
1080013500
39,243,642,745,346,246,650,050,054,557,164,869,674,581,2
0,7800,7800,5540,5540,3860,3860,2720,2720,2060,1610,1290,1060,0800,004
0,330,360,310,330,300,300,290,290,270,260,260,250,240,24
0,450,450,500,500,580,580,640,640,730,800,880,941,071,18
131131162162202202250250301352404462540620
3,583,585,015,017,157,15
10,0110,01
13,617,1621,4526,4634,3242,90
247532252950354035653960456047805750660081409640
1175014440
112511251575157522502250315031504275540067508325
1080013500
3x25+3x25/33x25+3x50/33x35+3x25/33x35+3x50/33x50+3x25/33x50+3x50/33x70+3x35/33x70+3x50/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
®
®BiTmining (N)TSCGEWOEU-F
13
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (®-FN)TSCGEWOEU 18/30kV
Medium voltage, flexible power supply cable for fixed installations
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (®-FN)TSCGEWOEU 12/20kV
3x25+3x25/33x25+3x50/33x35+3x25/33x35+3x50/33x50+3x25/33x50+3x50/33x70+3x35/33x70+3x50/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
48,348,350,550,555,755,759,659,665,067,672,679,184,089,0
0,7800,7800,5540,5540,3860,3860,2720,2720,2060,1610,1290,1060,0800,004
0,380,380,360,360,340,340,320,320,310,300,290,280,270,26
0,280,280,310,310,350,350,380,380,430,470,510,540,620,67
139139172172215215265265319371428488574665
3,583,585,015,017,157,15
10,0110,0113,6017,1621,4526,4634,3242,90
33453690372540754625497556955920712580409280
111801339515850
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (® -FN)TSCGEWOEU 14/25kV
54,454,456,656,660,060,065,765,769,371,976,983,488,393,3
0,7800,7800,5540,5540,3860,3860,2720,2720,2060,1610,1290,1060,0800,004
0,400,400,370,370,350,350,340,340,320,310,300,290,280,27
0,240,240,260,260,300,300,330,330,360,400,430,460,520,56
139139172172215215265265319371428488574665
3,583,585,015,017,157,15
10,0110,0113,6017,1621,4526,4634,3242,90
112511251575157522502250315031504275540067508325
1080013500
112511251575157522502250315031504275540067508325
1080013500
40304380444047905160551065356760775086809970
119301418516690
3x25+3x25/33x25+3x50/33x35+3x25/33x35+3x50/33x50+3x25/33x50+3x50/33x70+3x35/33x70+3x50/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
3x25+3x25/33x25+3x50/33x35+3x25/33x35+3x50/33x50+3x25/33x50+3x50/33x70+3x35/33x70+3x50/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
57,957,960,060,065,365,369,169,172,877,282,186,891,896,7
0,7800,7800,5540,5540,3860,3860,2720,2720,2060,1610,1290,1060,0800,004
0,410,410,390,390,370,370,350,350,330,320,310,300,290,28
0,210,210,240,240,260,260,290,290,320,350,380,400,460,49
139139172172215215265265319371428488574665
3,583,585,015,017,157,15
10,0110,0113,6017,1621,4526,4634,3242,90
112511251575157522502250315031504275540067508325
1080013500
4450480048755220588562307030726082759545
10880125551485017390
®
®BiTmining (N)TSCGEWOEU-F
Cable Factory BITNER reserve the right to modify specifications without prior notification.
*Cable outer diameter may differ from the one shown in table
Note: On customer's request other cross sections or number of cores can be produced
14
Technical data:
Application:
Chemical parameters:
Flexible power supply cable for use in strip and open-pit mining facilities, for high mechanical stresses, designed for connection of large material handling machines such as excavators, dumpers or mobile crushers. Main application: operation on cable reels
Resistance to oil: EN 60811-2-1, IEC 60811-2-1Behaviour in case of fire: VDE 0482 Part 332-1-2, EN 60332-1-2, IEC 60332-1-2Weather resistance: Unrestricted use indoors, outdoors, resistance to ozone, UV and moisture
Operating temperature:Fixed systems: -40°C to 90°CFlexible operation: -25°C to 80°CMaximum permissible operating temperature of the conductor: 90°CMaximum conductors operating temperature in short-circuit: 250°C
2Tensile load: 20 N/mmTorsional stresses: +/-100°/mMin. bending radius: acc. to DIN VDE 0298, Part 3Minimum distance with S-type directional changes: 20 x DTravel speed:- In operation: up to 60m/min- On rewinding: up to 100m/minOperating voltage: U /U= 3,6/6 kV to 18/30 kV0
Test voltage: 11 kV to 43 kVStandard: based on DIN VDE 0250 p.813
®BiTmining (N)TSCGEWOEU-RMedium voltage, flexible power supply cable for reeling applications
Construction:
Conductor: very finely stranded class 6 (EN 60228, DIN VDE 0295) not tinned, electrolytic copperInsulation:
Electrical field control: inner and outer layers of semiconductive rubberCore identification: Natural colouring with black semiconductive rubber and printed white digits 1 to 3Core arrangement: Three main conductors laid-up with protective-earth conductor split into 3 in the outer intersticesInner sheath: special EPR compound (acc. to DIN VDE 0207, Part 21)Anti-torsion reinforcement: braid of polyamide threads in a vulcanized bond between inner and outer sheath being integral part of an outer sheath
Outer sheath:
EPR compound with improved electrical and mechanical characteristics (DIN VDE 0207, Part 20)
. Protection from transverse and longitudinal stress.
5GM5 compound with improved mechanical characteristics (acc. to DIN VDE 0207, Part 21), waterproof, colour: red
®
Rated voltage U /U [kV]0
Maximum permissible operating voltage in AC systems U U [kV]/0
Maximum permissible operating voltage in DC systems U /U [kV]0
AC test voltage [kV]Current-carrying capacity According to DIN VDE 0298, Part 4
4,2/7,2
5,4/10,8
11
6,9/12
9/18
17
3,6/6 6/10 8,7/15 12/20 14/25 18/30
10,4/18
13,5/27
24
13,9/24
18/36
29
17,3/30
22,5/45
36
20,8/36
27/54
43
PN-EN60332-1industrial applications
mining applications
high flexibility
UV
UV resistance oil resistant mechanical resistance
oxygen index
>29
low operating temperature
explosion hazardous areas
a b cA B
power chains
15
Medium voltage, flexible power supply cable for reeling applications
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (
®-RN)TSCGEWOEU 8,7/15kV
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
® BiTmining (N)TSCGEWOEU -R 3,6/6kV
3x25+3x25/33x25+3x50/33x35+3x25/33x35+3x50/33x50+3x25/33x50+3x50/33x70+3x35/33x70+3x50/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
39,243,143,345,846,848,050,550,556,258,465,569,174,180,8
0,7800,7800,5540,5540,3860,3860,2720,2720,2060,1610,1290,1060,0800,064
0,310,350,300,320,280,300,270,270,260,250,250,240,240,23
0,440,440,500,500,580,580,650,650,740,820,900,971,101,21
131131162162202202250250301352404462540620
3,583,585,015,017,157,15
10,0110,01
13,617,1621,4526,4634,3242,90
15001500210021003000300042004200570072009000
111001440018000
254532163087366038104280475049606230713686509585
1177214440
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (®
-RN)TSCGEWOEU 6/10kV
3x25+3x25/33x25+3x50/33x35+3x25/33x35+3x50/33x50+3x25/33x50+3x50/33x70+3x35/33x70+3x50/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
41,844,545,047,148,548,553,355,157,960,167,270,877,682,5
0,7800,7800,5540,5540,3860,3860,2720,2720,2060,1610,1290,1060,0800,064
0,320,320,310,310,290,290,280,280,270,260,250,250,240,24
0,390,390,450,450,510,510,580,580,660,730,790,860,971,07
131131162162202202250250301352404462540620
3,583,585,015,017,157,15
10,0110,0113,6017,1621,4526,4634,3242,90
15001500210021003000300042004200570072009000
111001440018000
276533553250379539854320505554856430734088909840
1236014740
3x25+3x25/33x25+3x50/33x35+3x25/33x35+3x50/33x50+3x25/33x50+3x50/33x70+3x35/33x70+3x50/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
45,246,148,448,452,052,057,157,161,464,870,674,381,086,0
0,7800,7800,5540,5540,3860,3860,2720,2720,2060,1610,1290,1060,0800,064
0,340,340,330,330,310,310,300,300,280,270,270,260,250,25
0,310,310,360,360,410,410,450,450,510,570,620,670,750,82
139139172172215215265265319371428488574665
3,583,585,015,017,157,15
10,0110,0113,6017,1621,4526,4634,3242,90
15001500210021003000300042004200570072009000
111001440018000
30853500359039254350469055055715687079759390
103701294015350
®
®BiTmining (N)TSCGEWOEU-R
16
Medium voltage, flexible power supply cable for reeling applications
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (® -RN)TSCGEWOEU 18/30kV
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (® -RN)TSCGEWOEU 12/20kV
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (® -RN)TSCGEWOEU 14/25kV
3x25+3x25/33x25+3x50/33x35+3x25/33x35+3x50/33x50+3x25/33x50+3x50/33x70+3x35/33x70+3x50/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
48,248,251,451,456,856,860,560,565,469,373,679,184,089,0
0,7800,7800,5540,5540,3860,3860,2720,2720,2060,1610,1290,1060,0800,064
0,360,360,340,340,320,320,310,310,300,290,280,270,260,26
0,270,270,310,310,350,350,390,390,440,480,520,560,630,69
139139172172215215265265319371428488574665
3,583,585,015,017,157,15
10,0110,0113,6017,1621,4526,4634,3242,90
33853720391042404925546059356145741586509850
111701346015900
3x25+3x25/33x25+3x50/33x35+3x25/33x35+3x50/33x50+3x25/33x50+3x50/33x70+3x35/33x70+3x50/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
54,454,456,656,660,060,065,765,769,371,976,983,488,393,3
0,7800,7800,5540,5540,3860,3860,2720,2720,2060,1610,1290,1060,0800,064
0,380,380,360,360,340,340,320,320,310,300,290,280,270,27
0,230,230,260,260,300,300,330,330,370,410,440,470,530,58
139139172172215215265265319371428488574665
3,583,585,015,017,157,15
10,0110,0113,6017,1621,4526,4634,3242,90
15001500210021003000300042004200570072009000
111001440018000
40304380444047905160551065356760775086809970
119301418516690
3x25+3x25/33x25+3x50/33x35+3x25/33x35+3x50/33x50+3x25/33x50+3x50/33x70+3x35/33x70+3x50/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
15001500210021003000300042004200570072009000
111001440018000
3,583,585,015,017,157,15
10,0110,0113,6017,1621,4526,4634,3242,90
139139172172215215265265319371428488574665
57,457,460,660,664,564,569,369,373,178,582,886,891,896,7
0,7800,7800,5540,5540,3860,3860,2720,2720,2060,1610,1290,1060,0800,064
0,400,400,380,380,350,350,340,340,320,310,300,290,280,27
0,210,210,240,240,260,260,290,290,330,360,390,420,460,51
441547505005534059206255714573608550
1009511380125301490017425
15001500210021003000300042004200570072009000
111001440018000
®
®BiTmining (N)TSCGEWOEU-R
Cable Factory BITNER reserve the right to modify specifications without prior notification.
*Cable outer diameter may differ from the one shown in table
Note: On customer's request other cross sections or number of cores can be produced
17
Technical data:
Application:
Chemical parameters:
Flexible power supply cable for use in open-pit and underground mining facilities, a shipyards and docks for extremely high mechanical stresses during high travel speeds, multiple changes of direction into different planes, dynamic tensile loads etc. Cable designed mainly for large mobile equipment, excavators, container cranes etc.
Resistance to oil: EN 60811-2-1, IEC 60811-2-1Behaviour in case of fire: VDE 0482 Part 332-1-2, EN 60332-1-2, IEC 60332-1-2Water compatability: HD 22.16 (VDE 0282 Part 16)Weather resistance: Unrestricted use indoors, outdoors, resistance to ozone, UV and moisture
®BiTmining (N)TSCGEWOEU-SRMedium voltage, flexible power supply cable for high speed reeling applications
Operating temperature:Fixed systems: -50°C to 90°C Flexible operation: -35 °C to 80 °C Maximum permissible water temperature: 40°CMaximum permissible operating temperature of the conductor: 90°CMaximum conductors operating temperature in short-circuit: 250°C
2 Tensile load: 20 N/mm Torsional stresses: +/-25°/mMin. bending radius: acc. to DIN VDE 0298, Part 3Minimum distance with S-type directional changes: 20 x DTravel speed on gantry (reeling operation): 240m/min Operating voltage: U /U= 3,6/6 kV to 18/30 kV0
Test voltage: 11 kV to 43 kVStandard: based on DIN VDE 0250 p.813
Construction:
Conductor: very finely stranded class 6 (EN 60228, DIN VDE 0295) tinned, electrolytic copperInsulation:
Electrical field control: inner and outer layers of semiconductive rubberCore identification: natural colouring with black semiconductive rubber and printed white digits 1 to 3Core arrangement: three main conductors laid-up with optimised lay length, protective-earth conductor split into 3 in the outer intersticesInner sheath: special rubber compound, better than (acc. to DIN VDE 0207, Part 21) acting as a water barrier, colour redAnti-torsion reinforcement: braid of polyamide threads in a vulcanized bond between inner and double outer sheath being integral part of an outer sheath. Outer sheath: special double layer sheath made of 5GM5 compound, water-, abrasion- and tear-proof (acc. to DIN VDE 0207, Part 21), colour: red
EPR compound with improved electrical and mechanical characteristics (DIN VDE 0207, Part 20)
Protection from transverse and longitudinal stress
5GM5
®
Rated voltage U /U [kV]0
Maximum permissible operating voltage in AC systems U U [kV]/0
Maximum permissible operating voltage in DC systems U /U [kV]0
AC test voltage [kV]Current-carrying capacity According to DIN VDE 0298, Part 4
4,2/7,2
5,4/10,8
11
6,9/12
9/18
17
3,6/6 6/10 8,7/15 12/20 14/25 18/30
10,4/18
13,5/27
24
13,9/24
18/36
29
17,3/30
22,5/45
36
20,8/36
27/54
43
PN-EN60332-1industrial applications
mining applications
high flexibility
UV
UV resistance oil resistant mechanical resistance
oxygen index
>29
low operating temperature
explosion hazardous areas
a b cA B
power chains
18
Medium voltage, flexible power supply cable for reeling applications
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (®-SRN)TSCGEWOEU 8,7/15kV
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
®BiTmining (N)TSCGEWOEU -SR 3,6/6kV
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
39,442,746,051,356,459,865,369,376,381,4
2730323039555130660077159090
101551279015310
1500210030004200570072009000
111001440018000
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (®
-SRN)TSCGEWOEU 6/10kV
41,444,847,353,557,761,366,670,678,083,9
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
2915345041005400679079309300
103801312015810
1500210030004200570072009000
111001440018000
45,048,251,456,961,266,070,074,181,489,2
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
3290384045855855728086659860
109801377016890
1500210030004200570072009000
111001440018000
®
®BiTmining (N)TSCGEWOEU-SR
19
Medium voltage, flexible power supply cable for reeling applications
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (®-SRN)TSCGEWOEU 18/30kV
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (® -SRN)TSCGEWOEU 12/20kV
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (® -SRN)TSCGEWOEU 14/25kV
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
48,852,255,660,365,668,773,078,784,891,2
371537205120634079509100
10380118201446017330
1500210030004200570072009000
111001440018000
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
54,157,759,965,470,373,278,582,690,195,5
437050405720710087159870
11380125751556518300
1500210030004200570072009000
111001440018000
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
3x240+3x120/3 3x300+3x150/3
57,661,263,369,773,777,782,086,093,699,9
48305530623077909300
1066012040132701632019320
1500210030004200570072009000
111001440018000
®
®BiTmining (N)TSCGEWOEU-SR
Cable Factory BITNER reserve the right to modify specifications without prior notification.
*Cable outer diameter may differ from the one shown in table
Note: On customer's request other cross sections or number of cores can be produced
20
Technical data:
Application:
Chemical parameters:
Flexible cable for power supply or connections for large material handling or mining machines in open-pit mines where exposed to extremely high mechanical stresses, abrasion and tear usually during trailing operation.
Resistance to oil: EN 60811-2-1, IEC 60811-2-1Behaviour in case of fire: VDE 0482 Part 332-1-2, EN 60332-1-2, IEC 60332-1-2Weather resistance: Unrestricted use indoors, outdoors, resistance to ozone, UV and moisture
®BiTmining (N)TSCGEWOEU-TRMedium voltage, flexible power supply trailing cable
Operating temperature:Fixed systems: -40°C to 90°CFlexible operation: -25°C to 80°CMaximum permissible operating temperature of the conductor: 90°CMaximum conductors operating temperature in short-circuit: 250°CTensile load: 15 N/mm2Torsional stresses: +/-100°/mMin. bending radius: acc. to DIN VDE 0298, Part 3Operating voltage: U /U= 3,6/6 kV to 18/30 kV0
Test voltage: 11 kV to 43 kVStandard: based on DIN VDE 0250 p.813
Construction:
Conductor: finely stranded class 5 (EN 60228, DIN VDE 0295) tinned, electrolytic copperProtective-earth conductor: very finely stranded class 6 (EN 60228, DIN VDE 0295) tinned, electrolytic copperInsulation:
Electrical field control: inner and outer layers of semiconductive rubberCore identification: Natural colouring with black semiconductive rubber and printed white digits 1 to 3Core arrangement: Three main conductors laid-up with protective-earth conductor split into 3 in the outer intersticesReinforcement: extremely tear-resistant reinforcing tape preventing sheath movements and protecting from transverse and longitudinal stressInner and outer sheath: special EPR based 5GM5 compound (acc. to DIN VDE 0207, Part 21) with special tear- and abrasion resistance characteristics, inner and outer sheath are inseparably bonded. Sheath colour black.
EPR compound with improved electrical and mechanical characteristics (DIN VDE 0207, Part 20)
®
Rated voltage U /U [kV]0
Maximum permissible operating voltage in AC systems U U [kV]/0
Maximum permissible operating voltage in DC systems U /U [kV]0
AC test voltage [kV]Current-carrying capacity According to DIN VDE 0298, Part 4
4,2/7,2
5,4/10,8
11
6,9/12
9/18
17
3,6/6 6/10 8,7/15 12/20 14/25 18/30
10,4/18
13,5/27
24
13,9/24
18/36
29
17,3/30
22,5/45
36
20,8/36
27/54
43
PN-EN60332-1industrial applications
mining applications
high flexibility
UV
UV resistance oil resistant mechanical resistance
oxygen index
>29
low operating temperature
explosion hazardous areas
a b cA B
21
Medium voltage, flexible power supply trailing cable
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
®BiTmining (N)TSCGEWOEU -TR 3,6/6kV
45,848,052,457,161,764,370,175,8
0,7950,5650,3930,2770,2100,1640,1320,108
0,360,340,320,300,290,280,270,27
0,340,390,430,490,540,600,650,70
131162202250301352404461
3,054,276,108,54
11,5914,6418,3022,57
11251575225031504275540067508325
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x50/3 3x185+3x95/3
3120350042895450675076509015
10755
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (® -TRN) 6/10kVTSCGEWOEU
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (®
-TRN) /15kVTSCGEWOEU 8,7
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x50/3 3x150+3x70/33x185+3x50/3 3x185+3x95/3
48,150,354,559,463,066,472,472,477,977,9
0,7950,5650,3930,2770,2100,1640,1320,1320,1080,108
0,370,340,330,310,300,290,280,280,280,27
0,310,350,390,440,490,540,580,580,630,63
131162202250301352404404461461
3,054,276,108,54
11,5914,6418,3018,3022,5722,57
1125157522503150427554006750675083258325
33653750454057456925796093709380
1097011120
53,755,860,264,969,672,177,983,6
0,7950,5650,3930,2770,2100,1640,1320,108
0,390,370,350,330,320,310,300,29
0,250,280,310,350,390,420,460,50
139172215265319371428488
3,054,276,108,54
11,5914,6418,3022,57
11251575225031504275540067508325
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
400044105270652079008840
1030012140
®
®BiTmining (N)TSCGEWOEU-TR
22
Medium voltage, flexible power supply trailing cable
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (® -TRN)TSCGEWOEU 12/20kV
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (®-TR N) /30kVTSCGEWOEU 18
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
58,061,165,370,273,977,283,288,5
453051005985731085809690
1125013100
0,7950,5650,3930,2770,2100,1640,1320,108
0,410,390,370,350,330,320,310,30
0,220,250,270,300,330,360,390,42
139172215265319371428488
3,054,276,108,54
11,5914,6418,3022,57
11251575225031504275540067508325
Number of coresand nominalcross-section
2n x mm
Overallcable diameter*
[mm]
Conductorresistanceat 20 °C[Ω/km]
Inductance
[mH/km]
Operatingcapacitance
[µF/km]
Currentcarryingcapacityat 30 °C
[A]
Permissibleshort-circuitcurrent (1s)
[kA]
Approx. netweight[kg/km]
Maximumpermissibletensile force
[N]
BiTmining (® -TRN) /25kVTSCGEWOEU 14
0,7950,5650,3930,2770,2100,1640,1320,108
6480698079909440
10810120201374015770
71,573,777,982,886,489,895,7
101,3
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
0,450,430,400,380,370,350,340,33
0,170,190,210,230,250,270,290,31
139172215265319371428488
3,054,276,108,54
11,5914,6418,3022,57
11251575225031504275540067508325
3x25+3x25/33x35+3x25/33x50+3x25/33x70+3x35/33x95+3x50/3
3x120+3x70/3 3x150+3x70/3 3x185+3x95/3
65,367,571,976,681,383,889,695,3
55506020699083509850
108701248014470
0,7950,5650,3930,2770,2100,1640,1320,108
0,430,410,390,370,350,340,330,32
0,190,210,230,250,280,300,330,35
139172215265319371428488
3,054,276,108,54
11,5914,6418,3022,57
11251575225031504275540067508325
®
®BiTmining (N)TSCGEWOEU-TR
Cable Factory BITNER reserve the right to modify specifications without prior notification.
*Cable outer diameter may differ from the one shown in table
Note: On customer's request other cross sections or number of cores can be produced
23
®
Notes