    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 1 of 28

    Schema

    Ultima Fort

    Required Data Inputs for EricssonMarkets 2G-3G Infrastructure(for Version 4.0 and above)

    Copyright Notice

    Due to a policy of continuous product development and refinement, Schema reserves the right to alter thespecifications and descriptions outlined in this publication without giving prior notice of any kind. In addition,

    no part of this publication, taken as a whole or separately, shall be deemed to be part of any contract forequipment or services.

    Schema retains the sole proprietary rights to all information contained in this document. No part of thispublication may be reproduced, stored in a retrieval system, transmitted in any form or by any means,

    including but not limited to: electronic, mechanical, magnetic, photocopy, recording, or otherwise, in use now

    or in the future, without prior written consent from Schema.

    Copyright 2008 Schema

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    2/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 2 of 28

    Schema

    Table of Contents

    1 Introduction.............................................................................................. 4

    2 Required Information and Data................................................................. 5

    2.1 Optimization Area...........................................................................................5

    Network Data........................................................................................................6

    2.1.1 GSM Network Configuration....................................................................6

    2.1.2 UMTS Network Configuration (XML Format) ..............................................7

    2.1.3 Sector Coordinates File..........................................................................9

    2.1.4 UMTS Antenna File.............................................................................. 10

    2.1.5 *.mpr File.......................................................................................... 11

    2.1.6 Generic Loss File................................................................................. 11

    2.1.7 Mobile Measurement Data Recordings.................................................... 122.1.8 Activation of Recordings ...................................................................... 13

    2.1.9 Retrieval of Recordings........................................................................19

    2.2 Handover Statistics....................................................................................... 21

    2.3 Network Performance Statistics ...................................................................... 22

    2.3.1 Network Performance Evaluation........................................................... 24

    2.3.2 Radio Network Performance KPI Calculation............................................ 24

    3 Data Collection Checklist......................................................................... 26

    4 Appendix: Troubleshooting ..................................................................... 27

    4.1.1 The removeFile Parameter for BARFIL and MRR File Deletion..................... 27

    4.1.2 Additional Ericsson Information............................................................. 284.1.3 Parameter Database (PDB) Maps .......................................................... 28

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    3/28

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    4/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 4 of 28

    Schema

    1 Introduct ion

    This document contains a list of all the required information and data that must be collected on

    Ericsson GSM infrastructures for execution of the optional GSMUMTS Neighbor List

    Optimization feature in Ultima Fort v4.0, for systems with the Ericsson GSM infrastructure.

    The following data is required:

    Optimization area

    Ericsson BSS network configuration data (XML format)

    UMTS system network configuration (vendor XML format or Schema Format)

    GSM Sector coordinates data

    UMTS antenna file

    UMTS-to-GSM handover statistics

    UTRAN neighboring cell quality measurements

    Generic Loss File (optional)

    Performance reports

    The following data and information is required:

    Optimization area

    Nokia BSS network configuration data (XML format)

    UMTS system network configuration (vendor XML format or Schema Format)

    GSM Sector coordinates data

    UMTS antenna file

    UMTS-to-GSM handover statistics AKA Counter 93 (Section 2.3)

    UTRAN neighboring cell quality measurements AKA Counter 94 (Section 2.3)

    Generic Loss File (optional)

    Performance reports

    The following sections provide a more in-depth description of the required data sources and

    how to obtain them.

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    5/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 5 of 28

    Schema

    2 Requi red Information and Data

    2.1 Optim izat ion Ar eaThe definition of the network area to be optimized is:

    List of cells (from both networks) in the optimization area

    Extended list of cells, including a guard zone (in which only GSM cells required)

    Both lists are .txt files with one column, the first item being the word Sector, followed by a list

    of sector names (both GSM and UMTS).

    These lists can be generated by using the Ultima Fort selection tool, and saving the

    selection.

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    6/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 6 of 28

    Schema

    Netw or k Data

    2.1.1 GSM Netwo rk Conf ig urat io n

    2.1.1.1 CNA Export in Text Format

    Retrieve the required BSS network configuration file from the Ericsson OSS, using the Cellular

    Network Administrator (CNA), by running the following commands:

    Overall Network Configuration:

    cna_export NW = all, MSC = all, MSC_REF = none, BSC = all, BSC_REF = all, SITE = all,SITE_REF = none, CELL = all, CELL_REF = all, OUTPUT=AllParameters_YYYYMMDD.txt

    Foreign Cells:

    cna_export NW = all, FCELL = all, FCELL_REF = all, OUTPUT=foreign_HO_YYYYMMDD.txt

    (where: YYYY year, MM month, DD day)

    Notes:

    Foreign cell data must be exported in order to import the IRAT Handover with any UMTS

    network (Ericsson, as well as Nokia).

    Daily CNA adjustment jobs should be scheduled for each BSC to ensure that the network

    configuration is updated in the OSS.

    It is recommended that the BSS network configuration file be retrieved for each day of

    mobile measurement recordings. However, it is mandatory that this file be retrieved if any

    BCCH/BSIC changes were made between two days of recordings.

    The BSS network configuration file should be generated just before initiating the BAR and

    MRR recording sessions.

    The BSS network configuration should be retrieved for each OSS that is relevant to the

    optimization and surrounding areas in the network.

    BSC data is optional beginning from Release R12.

    At the beginning and end of the data collection process, the following optional data should be

    retrieved for all BSCs, and included in the Ultima Fort network environment:

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    7/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 7 of 28

    Schema

    Data Description

    RLCRP:CELL=ALL,DETAIL;Cell ResourcesDetails

    RXMOP:MOTY=RXOTG;Managed ObjectData

    RAEPP:ID=ALL;BSC ExchangeProperties

    Data retrieval should be performed via the BSC command line interface.

    The output of the command printout should be stored in text files. The command name (RLCRP,

    RXMOP, RAEPP) of each output type should be at the beginning of the file name, e.g.,

    RLCRP_BSC1.txt.

    2.1.1.2 New CNAI Export Format - R12:

    Release R12 supports the New CNAI (CNA Import) alternative format for network configuration

    files.

    The required BSS network configuration file can be retrieved from the Cellular Network

    Administrator (CNA) of the Ericsson OSS, using the following command: CNAI export valid i >

    AllParameters_YYYYMMDD.txt.

    2.1.2 UMTS Networ k Conf ig ur at io n (XML Form at)The UMTS Network configuration is an XML file in standard 3GPP format. Each UMTS OSS

    vendor has its own method of retrieving this file.

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    8/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 8 of 28

    Schema

    To retrieve the required BSS network configuration files from the Ericsson OSS:

    1. Go to ConfigurationWCDMA Radio access NetworkWCDMA RAN Explorer (usually via

    Citrix or OSS workstation).

    2.

    Right click on the root of the network and select Export Network Configuration.

    Figure 1: Retrieve the Required BSS Network Configuration Files

    Figure 2: Export the Required BSS Network Configuration Files

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    9/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 9 of 28

    Schema

    Choose the File Name and Radio topology.

    Figure 3: Save the Required BSS Network Configuration Files

    2.1.3 Secto r Coord inates Fi le

    The sector coordinates file should be in tab-delimited text file format, and should include

    geographical information for all of the network sectors, including the following columns:

    Sector

    Latitude

    Longitude

    Azimuth

    LAC (optional)

    CI (optional)

    Keywords (optional)

    The latitude and longitude values should be expressed in decimal-degree format, with up to six

    digits following the decimal point.

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    10/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 10 of 28

    Schema

    2.1.4 UMTS An ten na Fil e

    The UMTS Antenna file must be in tab-delimited text file format with full information for all the

    sectors in the optimization and guard-zone areas.

    Note: This file contains many fields (intended for future use), whose values are not currently

    used for the GSMUMTS Neighbor List Optimization feature.

    The required fields are in boldletters. Non-required fields should have real values for

    database integrity (but the feature can run with dummy values).

    RNC Name

    RNC Id

    Vendor

    NodeB Name

    NodeB Id

    NodeB Longitude

    NodeB Latitude

    Sector Name

    Active (boolean)

    Noise Figure

    AntennaID

    Antenna Model

    Sector Keywords

    Antenna Longitude

    Antenna Latitude

    Height

    Electrical DownTilt

    Mechanical DownTilt

    Azimuth

    Downlink Loss

    Uplink Loss RTT fix A Coefficient

    RTT fix B Coefficient

    In Building

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    11/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 11 of 28

    Schema

    The following file has a sample entry that corresponds to one antenna.

    Antennas.txt

    2.1.5 *.mpr Fi le

    The .mpr file is a text file (with the *.mpr extension) that points to the UTRAN topology file with

    the following pointer:

    ERICSSON_XML_FILE_NAME=path\topology_file_name.xml

    2.1.6 Generic Lo ss Fi le

    The Generic Loss File is of a generic horizontal antenna pattern, used to determine the order of

    potential neighbors in a measurement plan.

    If a user-defined file (optional) is not provided, Ultima Fort uses a one-column text file, with

    default values for each relative angle between the source and target sectors, in the following

    structure:

    Relative angle[degrees]= Loss[dB]

    For example:

    0=0

    1=0

    2=0.01

    3=0.03

    4=0.05

    5=0.08

    6=0.12

    7=0.15

    8=0.2

    9=0.25

    ..

    359=0

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    12/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 12 of 28

    Schema

    The following is a full example of the file:

    GenericLossFile.txt

    2.1.7 Mobi le Measurement Data Recor din gs

    The following activities should stop during data recording:

    BSC or RNC split

    Site re-parenting (e.g., BSC/site relation changes in the GSM network)

    LAC and CI changes in the GSM network, scrambling codes in the UMTS network, BCCH and

    BSIC in the GSM network

    Site and carrier additions

    Sector mechanical changes, such as tilt, azimuth, and antenna

    Manual UMTS GSM Neighbor additions or deletions

    The following changes should be performed only during maintenance (not during recording):

    TRX/Carrier additions

    Frequency changes (TCH)

    Frequency changes (BCCH and BSIC)

    Scrambling codes changes

    Manual UMTS GSM Neighbor additions or deletions

    Site additions

    No other parameters should be changed.

    Note: BSC Version R06A (R12) (or later versions) should be used.

    OSS Version RC3, RC5.3 (or later versions) should be used.

    The following features should be activated to collect mobile measurements on the

    Ericsson GSM OSS:

    NCS-G, (NCS-GSM)

    NCS-GW, (NCS-GSM/WCDMA)

    In addition to the optional OSS NCS GSM-WCDMA feature, the following features are required

    for IRAT modeling:

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    13/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 13 of 28

    Schema

    Optional OSS features:

    o FAJ 122 477, Neighboring Cell Support - GSM RAN (NCS-G)

    Optional BSS features:

    o

    FAJ 121 815, GSM-WCDMA Active BA-list Recording

    o FAJ 121 57, GSM-UMTS Cell Reselection and Handover

    Mobile measurements files can be extracted from the Ericsson OSS, and used by Ultima Fort

    either in binary format (Section 2.3.1) or in text format (Section 2.3.2).

    2.1.8 Act i vat ion of Recor din gs

    2.1.8.1 BA List Recordings (BAR) Recordings

    BAR recordings should be performed during three to five consecutive working days.BAR recording is activated by:

    RNO interface (if available): FAJ 122 477 Neighboring Cell Support - GSM RAN (NCS-G)

    BSC command interface

    To perform BAR recordings, using the RNO interface:

    1. Log in to OSS.

    2. Start RNO.

    3.

    Go to File

    New Recording

    NCS.4. Name the recording session.

    5. Select the Measure GSMand Measure WCDMAcheck boxes.

    6. Set the Relative SS Threshold to -12db.

    7. Set the Absolute SS Threshold to -80dbm.

    8. Set the BA List Change interval to 15 minutes.

    9. Set the number of test frequencies to add to each interval to 10.

    10.Enter a start date.

    11.Enter a repeat value (set to daily) and a number of repetitions (set to 5).

    12.Enter a date type with working days only (e.g., Monday to Friday five consecutive

    working days).

    13.Enter an hour range (four hours that include the network busy hour).

    14.Select the cell set or BSC (including every cell in the entire network).

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    14/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 14 of 28

    Schema

    15.Set the Cell Filter to a desired (available) frequency band (with the recorded cell set

    limited to a specified frequency band.)

    16.Select Frequencies. Create a Frequency Set for BAR recordings, including all frequencies

    used for the BCCH in the desired band for the entire network.

    17.Save and schedule the recording.

    Figure 4: RNO NCS New Recording

    Noteon WCDMA Settings:

    The recording configuration consists of the following:

    Number of WCDMA cells in each Measurement report.

    An Absolute Ec/No threshold.

    The maximum number of test UMFIs that may be added to the 3G active mode BA lists

    at one time.

    A set of test-UMFIs to be used in recording.

    The number of WCDMA cells in each measurement report is a recording parameter that can be

    set to either Network Settingsor to a numerical value between 1 and 3. The Network

    Settings value uses the current FDDMRRnetwork setting for the recording, which will remain

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    15/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 15 of 28

    Schema

    the same. The numerical values will activate a temporary value of the FDDMRRparameter to

    be used during recording. When active, this temporary value, called TFDDMRR,blocks any

    FDDMRR value update for the cells included in the recording.

    The temporary value is used to increase the amount of measurement data during the recording,and affects how the Multi-RAT mobiles report data in the measurement report. This, in turn,

    may affect the locating performance.

    The absolute Ec/No threshold is related to a counter, which is incremented whenever the

    Ec/NoUMFI> absequation is fulfilled absis the Ec/No absolute threshold and Ec/NoUMFIis the

    Ec/No value for a specific UMFI, reported by the Multi-Rat mobile. The ratio between Ec/NoUMFI

    and the number of measurement reports that include at least one reported UMFI during the

    period when the specific UMFI has been included in the 3G Active BA-list for the cell is a value

    that is used to determine whether or not the undefined WCDMA neighboring cell is included as a

    defined neighbor.

    A function calculates an appropriate set of test-UMFIs, based on a set of GSM cells. The WCDMA

    cell coordinates determine which of those cells, located in the same area as the GSM cells, are

    included in the recording. The user defines at which distance from the GSM cells the search is

    performed. A list of test-UMFIs is then generated, based on the WCDMA cells that are found.

    Since a maximum of 128 test-UMFIs may be included in a set, four recordings are needed to

    measure all 512 Scrambling Codes for a single WCDMA-frequency.

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    16/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 16 of 28

    Schema

    Figure 5: RNO NCS UMTS Settings

    Figure 6: RNO NCS New UMFI Set

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    17/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 17 of 28

    Schema

    Figure 7: RNO NCS Select Cell Set

    Additional Notes:

    Recordings in a dual band network should be made separately, based on the cell band.

    However, to provide full functionality of handover optimization, inter-band recordings

    should be made. Each band cell set should record a frequency set with the BCCH

    frequencies for both bands. Multi Band Cells Reported (MBCR), is a cell parameter that

    indicates how many neighbors from each frequency band are reported in the

    measurement report. The recommended setting is either 2 or 3 in multi-band network,

    in order for mobiles to report measurements from the opposite band.

    While BAR files can also be generated with the Frequency Allocation Support (FAS), the

    Neighboring Cell Support (NCS) should be used if possible.

    The NCCPERM defines the allowed NCCs on the BCCH carriers for which MSs are

    permitted to send measurement reports. Hence, if all NCCs are used, NCCPERM should

    be set accordingly (i.e., all NCCs included in NCCPERM parameter) so that all NCCs are

    reported. NCCPERM has no impact on idle mode behavior, since idle mode cell

    reselection is based on CGI, and not on ARFCN/BSIC).

    The Active BA list Recording may sometimes contain measurement results with

    unexpected, disallowed BSICs, (e.g., 00 or 77). This occurs when some MSs report

    irrelevant BSICs initially, before decoding actual BSIC information and is not related to a

    fault in the BA List recordings feature.

    If an operator has not purchased the RNO application to activate BAR recordings through NCS,

    the BAR recordings can be activated, using the following BSC command line interface:

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    18/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 18 of 28

    Schema

    1. RABRE:RID=RARID00; Terminate an NCS recording.

    2. RABIE:RID=BARID00; Delete a recording.

    3. RABII; Initiate a new recording.

    4.

    RABRP:RID=BARID00; Print a BAR recording status (optional).

    5. RABDC:RID=BARID00, CELL=ALL; Record all BSC cells.

    6. RABDC:RID=BARID00,TMBCCHNO=50&&124; Frequencies to measure 50 to 124.*

    7. RABDC:RID=BARID00,NUMFREQ=10; The number of test frequencies at each interval.

    8. RABDC:RID=BARID00,SEGTIME=15; The recording segment time in minutes.

    9. RABDC:RID=BARID00,RELSSN=12; Negative signal strength thresholds.

    10.RABDC:RID=BARID00,RELSS2P=0; Positive signal strength thresholds.

    11.

    RABDC:RID=BARID00, ABSS=80; Absolute signal strength (means negative dBm).12.RABDP:RID=BARID00; View recording properties.

    13.RABRI:RID=BARID00,DTIME=120; Recording period time in minutes, beginning as soon

    as this command is entered!

    14.RABTI:RID=BARID00,IO=FILE; After recording is complete, this command creates the

    output binary file in the OSS.

    15.RABTI:RID=BARID00, IO=AT-##; Substitute at-## with the number of the AT device

    seen when connecting to this BSC. The text output iproduced on the AT-## device**.

    * - The relevant frequency set should be used for each specific case.

    ** - If, for some reason, a binary file cannot be created, the BAR text output can be

    generated at the BSC command terminal, with the generated printout being stored as a

    text file.

    2.1.8.2 MRR Recordings

    Measurement Results Recordings (MRR) are files that contain RxLevel, RxQual, and traffic data.

    MRR recordings should be generated with, and for the same cell set as, BAR recordings, and

    without filtering or thresholds.

    An MRR recording may be activated via:

    RNO interface (if available): FAJ 122 522, Measurement Result Recording (MRR)

    BSC command interface

    To make MRR recordings using the RNO interface:

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    19/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 19 of 28

    Schema

    1. Log in to OSS.

    2. Start RNO.

    3. Go to File

    New Recording

    MRR.

    4.

    Name the recording session.

    5. Enter a Start date.

    6. Enter a repeat value (set to daily) and a number of repetitions (set to 5).

    7. Enter a date type with working days only (Monday to Friday five consecutive working

    days).

    8. Enter an hour range (three hours defined to include the network busy hour).

    9. Select the cell set or BSC (including every cell in the entire network).

    10.Set Cell Filter to a desired (available) frequency band. (The recorded cell set is limited to

    a specified frequency band.)

    11.Save and schedule the recording.

    In the absence of an RNO application, MRR recordings may be activated using the BSC

    command line interface, as follows:

    1. RAMRE: RID=MRRID00; Terminate an MRR recording.

    2. RAMIE: RID=MRRID00; Delete a recording.

    3. RAMII; Initialize a new recording.

    4.

    RAMRP: RID=MRRID00; Print status (optional).5. RAMDC: RID=MRRID00, CELL=ALL; All cells of a BSC are recorded.

    6. RAMDC: RID=MRRID00, MEASTYPE=NOTYPE; All measurement types are collected.

    7. RAMRI: RID=MRRID00, DTIME=120; Recording period time, which starts as soon as this

    command is entered!

    8. RAMRP: RID=MRRID00; Print status (optional).

    9. RAMTI: RID=MRRID00; After the recording is finished, this command should be run to

    create the output file.

    2.1.9 Retr i eval of Recor din gs

    2.1.9.1.1 BA list recordings (BAR) Record ings : Binary mode

    Binary format files contain C/I measurements.

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    20/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 20 of 28

    Schema

    Once recording is finished, the BARFILs files should be stored for each BSC on FTP. If they are

    not stored within 48 hours after recording, they will be deleted from the system.

    Binary BARFILs files are located in the following OSS directories:

    R8:

    o /var/opt/ehpt/eac/data/fs/BSC_NAME/

    R9/R10 and later with IOG20:

    o /root/var/opt/ericsson/nms_eam_eac/data/fs/BSC_NAME/

    R9/R10 and later with APG40:

    o /root/var/opt/ericsson/brf/data/db/tmpfileStore/BSC_NAME/

    Note:

    The binary transfer method should be used to transfer BARFILs from UNIX to Windows via FTP.

    All BARFILs recorded on the same day should be stored in the same directory.

    The Appendix provides information on troubleshooting situations in which BAR files are not

    created.

    2.1.9.2 Measurement Resul ts Recordings (MRR) - Binary Mode

    When the recording is finished, store the MRRFILs files for each BSC on an FTP. If they are not

    stored within 48 hours after recording, they will be deleted from the system.

    Binary MRRFILs files are located in the following OSS directories:

    R8:

    o /var/opt/ehpt/eac/data/fs/BSC_NAME/

    R9/R10 and later with IOG20:

    o /root/var/opt/ericsson/nms_eam_eac/data/fs/BSC_NAME/

    R9/R10 and later with APG40:

    o /root/var/opt/ericsson/brf/data/db/tmpfileStore/BSC_NAME/

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    21/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 21 of 28

    Schema

    Notes:

    Use the binary transfer method to transfer MRRFILs from UNIX to Windows via FTP.

    All MRRFILs recorded on the same day should be stored in the same directory.

    The Appendix provides information on troubleshooting situations in which MRR files are not

    created.

    2.1.9.3 NCS Recordings - Text Format Files

    NCS Recording files, available in the RNO application window, contain C/I measurements, which

    are similar to the information available in the raw binary BAR recordings.

    NCS files can be exported from the RNO application window in pairs, one with an *.msmt

    extension (data) and one with a *.conf extension (file configurations and recordings

    information).

    2.1.9.4 MRR Recordings - Text Format Files

    MRR Recording files contain RxLevel, RxQual, and traffic data, which can be extracted in either

    binary or text formats. Text format can be exported directly form the RNO application window.

    Text MRR files are extracted in pairs: one with an *.msmt extension (data) and one with a

    *.conf extension (file configurations and recordings).

    MRR recordings are exported to ASCII files via the RNO GUI. Both export files (*.msmt and

    *.conf) should be transferred. The data from these files may be used to back up MRRFIL files.

    2.2 Hando ver Stat i st ic s

    Handover statistics for each cell-to-cell relation should be collected for handover optimization.

    These statistics should be aggregated for an entire week for each cell-to-cell relation, and

    provided in a tab-delimited text file with the following fields:

    Serving Sector

    Target Sector

    Handover Attempts

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    22/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 22 of 28

    Schema

    Notes:

    The following counter can be extracted from 3G OSS for IRAT Handovers from 3G to 2G

    cells: pmnoattoutirathospeech

    It is not necessary to import 3G to 3G handover attempts, since they are not optimized inFort.

    2.3 Netw or k Perf orm ance Stat ist ic s

    Network performance statistics should be collected for network traffic modeling and post-

    optimization network performance benchmarking.

    The following network performance statistics should be collected per cell, and calculated hourly

    over seven consecutive days:

    Overall GSM HO Performance (Cell to Cell Relation, HO Attempts, HO Reversions, HO Lost,).

    These statistics should include the following counters: HOVERCNT, HOVERSUC, HORTTOCH,

    HOASBCL, HOASWCL, HOUPLQA, HODWNQA, HOATTLSS, HOATTHSS.

    Specific IRAT HO performance should be calculated from a 2G network using the following:

    o The number of handover commands sent to mobile station, with the neighboring UTRAN

    cell as target cell (HOVERCNTUTRAN).

    o The number of successful handovers to the neighboring UTRAN cell (HOVERSUCUTRAN).

    o The number of handover attempts to the neighboring UTRAN cell when the MS returned

    to the old channel (HORTTOCHUTRAN).

    o

    The number of handover commands sent to mobile station due to urgency in the GSMcell, with the neighboring UTRAN cell as target cell (URGHOVERUTRAN).

    o The number of successful handover attempts, due to urgency in the GSM cell, to the

    neighboring UTRAN cell (SUCURGHOUTRAN).

    Specific IRAT HO performance should be calculated from a 3G network using the following:

    KPI DESC Equation

    Voice 3G-2G IRAT HOFailure Rate (%)

    IRAT failure rate forvoice calls when thetrigger is based on an RFcondition. When thevoice call is notsuccessfully handed overto GSM network, the callis returned to the UMTSnetwork and continues inUMTS until it attempts

    100*[1-(pmnosuccessoutirathospeech/pmnoattouthospeech)]

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    23/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 23 of 28

    Schema

    another IRAT HO. Thiscounter will only beincremented in theSRNC.

    Voice 3G-2G IRAT HOfailures

    Total number of voiceIRAT 3G-2G failures.

    (pmnoattoutirathospeech -pmnosuccessoutirathospeech)

    Total Voice 3G-2G IRAT HO(incl SBHO) Failure Rate(%)

    The IRAT failure rate forvoice calls when thetrigger is based on an RFcondition and a service-based handover. Whenthe voice call is notsuccessfully handed overto the GSM network, thecall is returned to theUMTS network and

    continues in UMTS until itattempts another IRATHO. This counter willonly be incremented inthe SRNC.

    100*[1-{pmNoSuccessOutIratHoSpeech+pmNoSucssSbHoSpeech}/{pmNoAttOutIratHoSpeecpmNoAttOutSbHoSpeech}]

    Total Voice 3G-2G IRAT HO(incl SBHO) failures

    Total number of IRATfailures, includingService based HOs.

    [(pmNoAttOutIratHoSpeech+pmNoAttOutSoSpeech)-(pmNoSuccessOutIratHoSpeech+pmNoSucssSbHoSpeech)]

    PS Interactive IRAT FailureRate (%)

    The inter-RAT CC fromUTRAN to GPRS when UEis on DCH. The counter isincreased when the CellChange Order FromUTRAN Failure (RRC)message is received fromthe UE.

    100*(pmnooutiratccreturnoldch/pmnooutircatt)

    PS interactive IRAT HOfailures

    Total number of PSinteractive IRAT failures (pmnooutiratccatt - pmNoOutIratCcSuccess

    Multi-RAB IRAT Failure Rate(%)

    The outgoing (to GSM)inter-RAT handoverfailure rate for multi-RABfor the best cell in the

    active set. The counter isonly incremented inSRNC.

    100*[1-{pmNoSuccessOutIratHoMulti/pmNoAttOuttHoMulti}]

    Multi RAB IRAT HO failuresTotal number of Multi-RAB IRAT failures.

    (pmNoAttOutIratHoMulti -pmNoSuccessOutIratHoMulti)

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    24/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 24 of 28

    Schema

    Hs Cell Change Failure Rate(%)

    The HS Cell Changefailure rate. The counterstops after a RRCPhysical ChannelReconfigurationComplete has beenreceived from the UEduring the HS-DSCH CellChange, or after a RRCRadio BearerReconfiguration whenthere is a PDU sizechange during a HS-DSCH Cell Change.

    100*[1-{pmNoHsCcSuccess/pmNoHsCcAttempt}]

    HS Cell Change FailuresTotal number of HS CellChange failures, (pmNoHsCcAttempt - pmNoHsCcSuccess)

    2.3.1 Netwo rk Perfo rmanc e Evaluat ion

    Each KPI improvement rate will be calculated as:

    %100__

    =before

    afterbefore

    KPI

    KPIKPIratetimprovemenKPI

    The improvement in the handover success rate will be calculated as:

    %1001

    __

    =

    before

    beforeafter

    KPI

    KPIKPIratetimprovemenSuccess

    Each KPI improvement ratio can be calculated separately over a period of five working days

    (during each days network busy hour) before and after the optimization cycle.

    Any network performance KPIs that are not related to the BSS subsystem should be excluded

    from the calculation.

    2.3.2 Radio Netwo rk Perfo rmanc e KPI Calcu lat ion

    The following formulae calculate the KPIs that evaluate radio network performance:

    =)HOVERCNT(

    )HOVERSUC(___ RateSuccessHOOutgoing

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    25/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 25 of 28

    Schema

    Outgoing 3G-2G IRAT HO Failure Rate (%) = (pmnosuccessoutirathospeech /

    pmnoattoutirathospeech)

    Outgoing 2G-3G IRAT HO Failure Rate (%) = HOVERSUCUTRAN/ HOVERCNTUTRAN

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    26/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 26 of 28

    Schema

    3 Data Col lect ion Checkl istSOURCE COMMENTS CHECK

    Network Data

    GSMS Network Configuration

    UMTS Network Topology(XML)

    GSM Sector Coordinates File

    UMTS Antennas file

    UMTS .mpr file

    Generic Loss File optional

    Mobile Measurements & IRAT HO statistics Recordings

    Day 1 Day 2 Day 3 Day 4 Day 5

    Prior to the measurementplan

    During the measurementplan

    After the measurement plan

    Network Performance Statistics (before and after the plan)

    IRAT HO failure rate UMTS-to-GSM HO attempts

    UMTS-to-GSM HO Success

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    27/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    May 08 Proprietary and Confidential Page 27 of 28

    Schema

    4 Appendix: Troub leshoot in g

    BARFIL and MRRFIL files are transferred from the BSC to the OSS, once the recording has

    finished.

    4.1.1 The removeFi le Parameter for BARFIL and MRR Fi le Delet i on

    To check the setting of the removeFile parameter:

    1. Connect to the OSS via an external application, such as Citrix ICA Client.

    2. Check the file removing option in OSS, which automatically deletes MS files (perhaps to

    avoid hard disk space problems). The possible values for this parameter are:

    removeFile Value Result

    0MS files will not beremoved

    1MS files will beremoved

    Parameters in OSS are stored in Parameter Database (PDB) maps. The removeFile parameter

    belongs to the BRF map.

    To determine the value of the OSS parameters, use the cap_pdb_get_para command:

    cap_pdb_get_para n brf removeFile

    The Ericsson Alex Library has additional details.

    3. Change the value of the file removing option from 1 to 0, using the cap_pdb_mu

    command (with the correct user privileges). (If the file removing option is set to 1, files

    will be deleted.) If the BRF map is edited with an editor such as VI, it may lock the

    database, and the cap_pdb_mu command may not work with BRF. A user with Super

    User access (and perhaps additional knowledge) may be able to resolve this problem.

    4. Activate the NCS recording using the RNO.

    5. Look for BARFIL and MRRFIL files after completing the collection process, since these

    files must be located in their corresponding directories.

    6. Return the file removing option to its original value (1) after completing the MS

    collection. If this parameter is not changed back to the original value, the result may be

    a reduction in hard disk space, in addition to other collateral problems.

  • 8/9/2019 Ultima forte required data inputs for ericsson markets 2g-3g infrastructure.pdf

    28/28

    Ultima Fort Required Data Inputs for Ericsson Markets 2G-3G Infrastructure

    4.1.2 Addi t i ona l Er icsso n In format ion

    (This material originally appears in official documentation, entitled Op e r a t i o n s Su p p o r t

    S y s t em ( O s s ) R c 1 . 1 , Cp 4 ).

    Files retrieved from APG40 are stored in the /tmpFileStore/ directory.

    File Description

    The path is stated bythe dbPathparameter in BRFmap.

    The BSC.

    The removeFile parameter in the BRF map can be set up to delete files automatically, as

    explained in the previous section.

    4.1.3 Paramet er Databas e (PDB) Maps

    Each application has its own parameter database map, with parameters relating to the current

    installation.

    When the appropriate command is entered in the command shell window (man -s7 ), additional map information is displayed on the main page.

    Application Map Name

    BRF Brf

    FAS Fas

    FOX Fox

    NCS Ncs

    NOX Nox

    TET Tet

    MRR Mrr

    Use cap_pdb_mu to edit the map.

    Note:

    To edit system parameters, select RNO System Parametersfrom the Optionsmenu in the

    RNO main window.