university of south carolina notes: callcott social
TRANSCRIPT
University ofSouth CarolinaCallcott Social
ScienceRoof Replacement
(H27-6100-B)
10/131
Notes:
No. Revision/Issue Date
T-1(Title Page)
Lyon & AssociatesRoofing and WaterproofingConsultants
Prepared by
Not to Scale1 of 5
10/2013SheetDate
Scale
University of South CarolinaCallcott Social Science
Roof Replacement
Drawing IndexT-1 Title SheetR-1 Roof Plan - Existing ConditionsR-2 Roof Plan - NewD-1 Roof DetailsD-2 Roof DetailsS1.0 Safety Anchor Plan Callcott Social Science Building
709 Bull StreetColumbia, South Carolina
DateRevision/IssueNo.
General Notes
1 10/13
1) Roof top equipment and drainlocationsare approximate
2) Contractor's are responsible forall measurements
Legend
GravityVent
Roof Drain
StackVent
LigtningRod
Pitch Pan
Plumbing Vent
Curb
RoofAccessStairs
Wood ConduitSupport
Contractor Notes:
R-1(EXISTING)
Lyon & AssociatesRoofing and WaterproofingConsultants
Prepared by
Not to Scale2 of 5
10/2013SheetDate
Scale
University ofSouth CarolinaCallcott Social
ScienceRoof Replacement
(H27-6100-B)
DateRevision/IssueNo.
General Notes
1 10/13
R-2(NEW)
1) Roof top equipment and drainlocationsare approximate
2) Contractor's are responsible forall measurements
3) Insulation cricket length to widthratio is 3:1. Cricket slope is doublethat of roof slope
4) Existing roof drains may requirelowering in order to achieveproper sump. Sump size: 4' x 4'
5) Roof top security lighting is tobe flashed with pitch pan and sheetmetal hood
6) 110 power outlet is to besupported with new stand
Legend
SumpedRoof Drain
StackVent
LigtningRod
Lyon & AssociatesRoofing and WaterproofingConsultants
Prepared by
Not to Scale3 of 5
10/2013SheetDate
Scale
Contractor Notes:
Curb
RoofAccessStairs
ConduitSupport
Pitch Pan
Plumbing Vent
110 Power Outlet
University ofSouth CarolinaCallcott Social
ScienceRoof Replacement
(H27-6100-B)
D-1(Roof Details)
Lyon & AssociatesRoofing and WaterproofingConsultants
Prepared by
Not to Scale4 of 5
10/2013SheetDate
Scale
University ofSouth CarolinaCallcott Social
ScienceRoof Replacement
(H27-6100-B)
DateRevision/IssueNo.
1 10/13
COUNTERFLASHING
APPROPRIATE SEALANT
FRICTION FIT SHEET-METALREGLET--INSERT IN RAGGLEJOINT
APPROPRIATE FASTENERSAPPROX. 24'' O.C.
3'' LAP WITH BEAD OF SEALANT
REMOVABLE SHEET-METALCOUNTERFLASHING
OPTIONAL: 2'' WIDE CLIPAPPROX. 30'' O.C.
APPROX. 3'' LAP AT JOINTS
LEAD WEDGE AT APPROX. 24''O.C.
INSERT REGLET AND COUNTERFLASHINGWITH OVERLAP JOINT
SHEET-METAL RECEIVER WITHREMOVABLECOUNTERFLASHING--SEE NOTES 5 AND 6
OPTIONAL: SEAL TOP OFFLASHING WITH A COMPATIBLEVERTICAL-GRADE ROOF CEMENTAND REINFORCEMENT
FASTENERS APPROX. 8'' O.C.
NONCOMBUSTIBLE SUBSTRATE,PRIME SURFACE AS REQUIRED
OPTIONAL: EXTENDED FIELDPLIES ABOVE TOP OF CANT
CANT
BASE FLASHING WITH TWO-PIECE SHEET-METALCOUNTERFLASHING
8''M
INIM
UM
FLAS
HIN
GH
EIG
HT
BACKER (FOR TORCH-APPLIEDSYSTEMS: SELF-ADHERINGSHEET, MOPPED POLYMER-MODIFIED-BITUMEN BASE SHEETOR TWO TYPE IV PLIES MOPPED)WITH SEALED LAPS
MEMBRANE FLASHING SHEETADHERED TO BACKER (FORTORCH-APPLIED SYSTEMS--SEE NOTE 3)
APPROX. 4''
ROOF DRAIN
POLYMER-MODIFIED BITUMENMEMBRANE STRIPPING SHEET
APPROX. 4"
OPTIONAL: COMPATIBLESEALANT AT JUNCTION OFMEMBRANE AND EDGEMETAL
SET FLANGE IN COMPATIBLEROOF CEMENT AND PRIMEFLANGE BEFORE STRIPPING
POLYMER-MODIFIEDBITUMEN PLY SHEET
2 X 6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE--OVERALL THICKNESS TO MATCH INSULATION
ONE PLY OR SEPARATE MEMBRANE SHEETEXTENDED BELOW BLOCKING
EMBEDDED EDGE METAL FLASHING
POLYMER-MODIFIED BITUMEN CAPSHEET
SHEET-METAL GRAVELSTOP--SEE NOTES 4 AND 5
3 to 6 inchesmax.
PERIMETER EDGE-METAL SECUREMENT AND FASCIA EXTENSION
EMBEDDED EDGE (A-TYPE)
UP TO1 1/2''
3'' MIN.FLANGE
FASTEN APPROX. 3'' TO 6'' O.C. STAGGERED(USE 3" SPACING FOR ANSI/SPRI ES-1 COMPLIANCE),WITH CORROSION-RESISTANT, BARBED, ANNULAR RINGOR SCREW SHANK NAIL. LENGTH TO ACHIEVE APPROX. 11/4'' PENETRATION INTO NAILER
FASCIA EXTENSION
PERIMETER EDGE METAL WITH COVER PLATE
ROOF SIDE
FACE SIDE
SHEET-METAL COVER PLATESET IN SEALANT
SHEET-METAL COVER PLATESET IN SEALANT
PERIMETER EDGE METAL
APPROX.1/2'' G
AP
6" MIN.
6" MIN.
APPROX.1/2'' G
AP
BEND FLANGE ATROOF SIDE
OPTION
APPROPRIATE FASTENERSAPPROX. 3" TO 6" O.C.STAGGER PATTERN VARIES PERROOF SYSTEM
APPROPRIATE FASTENERSAPPROX. 3" TO 6" O.C.STAGGER PATTERN VARIES PERROOF SYSTEM
Contractor Notes:
Wood Nailer Fastener
Mechanical Watertight Connection Seal
Existing Rain Water Leader
Drain Body
Existing Drain Bowl
Base Sheet
Cap Sheet
Aluminum Strainer Dome
Metal stud with self locking nut
Flange Fastener
Insulation sloped to drain
Sealant
Aluminum Clamping Ring
Cold Adhesive
ReinforcingPly
Wood Nailer
Concrete Deck
ANTI-SLIP TREADA
TREAD WELDED AND BOLTEDTO STRINGER WITH 3/8"
HEX HEAD BOLTS
1-1/4" x 1-1/4" x 1/4"ANGLE WELDED TO TREAD
ASREQ'D
ALUMINUM PIPE1-1/4" SCH 40
(6005-T5)HANDRAIL
ALUMINUM CHANNEL8" x 2-1/4" x 1/4"
A
AS REQ'D BY CODE
INTERNALALUMINUMFITTINGS
TOE BOARDS
(TYPICAL)42"
B
VERTICALHEIGHT
APPROX3'
POLYMER-MODIFIED BITUMENPLY SHEET
OPTIONAL: COMPATIBLEROOF CEMENT OR COMPATIBLESEALANT AT PENETRATION-TO-MEMBRANE JUNCTURE
WEATHERPROOF SHEET-METALPENETRATION POCKET
NONSHRINKGROUT
POLYMER-MODIFIED BITUMENMEMBRANE STRIPPING SHEET
FLANGE SET IN COMPATIBLE ROOF CEMENT OVER FIELDPLIES--PRIME FLANGE BEFORE STRIPPING
SHEET-METAL RAIN COLLAROVERLAPPING PENETRATIONPOCKET WITH APPROPRIATESEALANT (E.G., POLYURETHANE)AND DRAWBAND
2" APPROX. POURABLE SEALANT
POLYMER-MODIFIED BITUMENCAP SHEET
APPROX. 4''
D-2(Roof Details)
Lyon & AssociatesRoofing and WaterproofingConsultants
Prepared by
Not to Scale5 of 5
10/2013SheetDate
Scale
L
CUAT / ALAT - STYLE GENTLYTAPERED AIR TERMINAL
155 / 156 - STYLEUNIVERSAL CONCEALEDAIR TERMINAL BASEMOUNTED VERTICALLY
CCC / ACC - STYLECABLE FASTENER
COPPER OR ALUMINUM,CLASS I OR CLASS IILIGHTNING PROTECTIONCONDUCTOR
120 - STYLE AIR TERMINALADAPTER
L5 H0 2
U
PH
LIGHTENING PROTECTION CABLE FLASHING
CLOSED CELLNEOPRENE PLUG (SLOTTED)
PVC
PVC STACKFACTORYSEALED TOSTAINLESSSTEEL SLEEVE
STAINLESSSTEELSLEEVEFACTORYSOLDERED
CLEAR TREAD22"MIN-48"MAX
CLEAR TREAD + 4-1/2"
8" MIN
3 1/2" TYP.
University ofSouth CarolinaCallcott Social
ScienceRoof Replacement
(H27-6100-B)
DateRevision/IssueNo.
Contractor Notes:
1 10/2013
CANT
2 X 6 MIN.WOOD NAILERATTACHED TOSUBSTRATE--OVERALLTHICKNESS TO MATCHINSULATION
OPTIONAL: EXTENDEDFIELD PLIES ABOVE TOPOF CANT
FASTENERS APPROX. 8''O.C.
GASKETED FASTENERS--MIN. TWO FASTENERS PERSIDE
SEALING MATERIAL
CONCRETE ORWOOD CURB
BASE FLASHING AT CURB LOCATIONS
FLAS
HIN
GH
EIG
HT
8''M
INIM
UM
BACKER
ROOFTOP EQUIPMENTFRAME
MOP- OR COLD-APPLIEDMEMBRANE FLASHINGSHEET ADHERED TOBACKER
APPROX. 4''
SHEET-METAL STACK VENT
OPTIONAL: METAL LINERAND INSULATION
COMPATIBLE ROOFCEMENT OR COMPATIBLESEALANT ATFLASHING-TO-MEMBRANE JUNCTURE
4'' MIN. FLANGESET IN COMPATIBLEROOF CEMENT--PRIME FLANGEBEFORE STRIPPING.
SHEET-METAL RAINCOLLAR
SHEET-METAL FLASHING
POLYMER-MODIFIEDBITUMEN MEMBRANESTRIPPING SHEET
APPROPRIATE SEALANT(E.G., POLYURETHANE)
DRAWBAND
8''M
INIM
UM
FLAS
HIN
GH
EIG
HT
SEALANT
POLYMER-MODIFIEDBITUMEN PLY SHEET
POLYMER-MODIFIEDBITUMEN CAP SHEET
APPROX. 4"
APPROX. 4''
TOP OF FLASHING CAPPED ORROLLED INTO PIPE APPROXIMATELY1''
SOFT METAL PIPE FLASHING--SEE NOTE 1
PLUMBING VENT STACK
POLYMER-MODIFIED BITUMENMEMBRANE STRIPPING SHEET
OPTIONAL: COMPATIBLE ROOFCEMENT OR COMPATIBLE SEALANTAT PENETRATION-TO-MEMBRANE JUNCTURE
POLYMER-MODIFIED BITUMEN CAPSHEET
SET FLANGE IN COMPATIBLE ROOFCEMENT--PRIME FLANGE BEFORESTRIPPING.
PLUMBING VENT
8''M
INIM
UM
FLAS
HIN
GH
EIG
HT
POLYMER-MODIFIED BITUMEN PLYSHEET
PENETRATION POCKET--SINGLE PENETRATION
WALL MOUNTED LIGHTNINGPROTECTION TERMINAL
CONDUIT SUPPORT ROOF ACCESS STAIRS