university of texas health science center · 2015-11-06 · hvac shaft shaft fec3 cg cg cg cg fvc...
TRANSCRIPT
C 2014 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.
CLIENT
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DESIGN TEAM
PROJECT ADDRESS
45009.0000
UNIVERSITY OF TEXAS
95% CONSTRUCTION DOCUMENTS
10/30/15
6901 BERTNERHOUSTON, TEXAS 77030
ARCHITECT:
FKP ARCHITECTS, INC.8 GREENWAY PLAZA, SUIITE 300HOUSTON, TEXAS 77046-0801P: 713-621-2100F: 713-621-2178WWW.FKP.COM
.M.E.P. ENGINEER:
CCRD808 TRAVIS STREET, SUITE 200HOUSTON, TEXAS 77002P: 713-237-8900F: 713-237-0123WWW.CCRD.COM
HEALTH SCIENCE CENTER
SCHOOL OF NURSINGLEVEL'S 5 & 6OFFICE SUITE RENOVATION
SHAFT
SHAFT
FVCFVC FVC
SHAFT
DN
UPUP
DN
OPEN OPEN
DNUP
SHAFT
FEC3
HVAC
SHAFT
SHAFT
FEC3
CG CGCG CG
FVCFVC FVC
FEC1FEC1
DN
UPUP
DN
OPEN OPEN
DNUP
FE2 FE2
FEC3
FEC3
25'
23'-63_8"Surplus Storage
10'-0" High Surplus Storage Containment Wall
HVAC
SHAFT
SHAFT
FEC3
CG CGCG CG
FVCFVC FVC
FEC1FEC1
DN
UPUP
DN
OPEN OPEN
DNUP
FE2 FE2
FEC3
HVAC
SHAFT
SHAFT
FEC3
CG CGCG CG
FVCFVC FVC
FEC1FEC1
DN
UPUP
DN
OPEN OPEN
DNUP
FE2 FE2
FEC3
SHAFT
SHAFT
FVCFVC FVC
SHAFT
DN
UPUP
DN
OPEN OPEN
DNUP
SHAFT
1i
A1011
SIM
A1.00 2
A1.00 2
1A101
SIM
1A101
SIM
1
A101
SIM
5' - 0"
1
01
EQ8888
#
ROOM NAME
?
DOOR TAG
WINDOW TAG
01 GLAZING TAG
CUT LINE
CENTER LINE
COLUMN GRID
PLAN DETAIL REFERENCE
PLAN DETAIL REFERENCE
EQUIPMENT TAG
EXTERIOR ELEVATION
INTERIOR ELEVATION
BUILDING SECTION REFERENCE
WALL SECTION REFERENCE
DETAIL SECTION REFERENCE
SPOT ELEVATION
KEYNOTE REFERENCE (NOTES TO SHEET)
WALL TAG
REFERENCE POINT
LEVEL LINE
REVISION SYMBOL
MATCH LINE
1 INS
NAMEELEVATION
Base
Floor
Wes
t
North
East
South
ROOM FINISH TAG
NON RATED SMOKE PARTITION1 HOUR FIRE PARTITION WITH 1/3 HOUR OPENINGS1 HOUR FIRE/SMOKE PARTITION WITH 1/3 HOUR OPENINGS1 HOUR FIRE BARRIER WITH 3/4 HOUR OPENINGS1 HOUR FIRE/SMOKE BARRIER WITH 3/4 HOUR OPENINGS1 HOUR FIRE BARRIER WITH 1 HOUR OPENINGS1 HOUR FIRE/SMOKE BARRIER WITH 1 HOUR OPENINGS2 HOUR FIRE BARRIER WITH 1 1/2 HOUR OPENINGS2 HOUR FIRE/SMOKE BARRIER WITH 1 1/2 HOUR OPENINGS3 HOUR FIRE BARRIER WITH 3 HOUR OPENINGS3 HOUR FIRE/SMOKE BARRIER WITH 3 HOUR OPENINGS
NON RATEDPARTITION
2 HR FIRE BARRIER 11/2 HR OPNG
2 HR FIRE/SMOKEBARRIER 1 1/2 HR OPNG
1 HR FIRE PARTITION1/3 HR OPNG
1 HRFIRE/SMOKEPARTITION1/3 HR OPNG
1 HR FIREBARRIER 3/4HR OPNG
1 HR FIRE/SMOKEBARRIER 3/4 HROPNG
NONRATEDSMOKEPARTITION
F.E.
F.E.C. F.V.C.FIRE EXTINGUISHER CABINIETAND EXTINGUISHER
SURFACE MOUNTEDFIRE EXTINGUISHER
DISCHARGE FROM FLOOR
EXIT LIGHT
FIRE VALVE CABINET
AREA OUT OF THE SCOPE
AREA OFWORK
AREA OFWORKAREA OF
WORK
1 2 3 4 5 67 8
2.2 7.7
A
B
C
D
E
A.1
D.9
A.9
C.1
12 3 4
5 67 8
2.2 7.7
A
B
C
D
E
A.1
D.9
A.9
C.1
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
45009.0000
GENERALINFORMATION & LIFESAFETY PLANS
A0.1
SCHOOL OF NURSINGLEVELS 5 & 6 OFFICESUITE RENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
A. DO NOT SCALE DRAWINGS: USE FIGURED DIMENSIONS ONLY.B. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE PROCEEDING
WITH THE WORK.C. ENLARGED PLANS: WHERE ENLARGED OR PARTIAL PLANS ARE
REFERENCED, DIMENSIONS AND SPECIAL DETAILING OR FINISHREQUIREMENTS ARE NOTED ON THE ENLARGED PLANS AND AREUSUALLY OMITTED ON THE SMALLER SCALE PLANS.
D. WALL AND PARTITION OPENINGS: DOOR AND WINDOW OPENINGS AREIDENTIFIED BY A TAG THAT CORRESPONDS TO THE ROOM NUMBER INWHICH THE OPENING OCCURS OR GIVES ACCESS TO. IF MORE THANONE DOOR OR WINDOW OCCURS IN A SPACE, EACH IS DIFFERENTIATEDWITH A LETTER SUFFIX.
E. NOTES TO SHEET: NOTE BUBBLES WITH INSCRIBED NUMERALS REFERTO THE "NOTES TO SHEETS" COLUMN CONTAINED ON THE SAME SHEET.IF A NOTE CONTAINS WORDING REFERENCING OTHER CONSULTANT’SWORK THEN IT IS INFERRED THAT CORRESPONDING DOCUMENTSPREPARED BY THE RELATED CONSULTANT SHOULD BE REVIEWED FORMORE SPECIFIC INFORMATION.IF THE FOLLOWING WORDS (BELOW LEFT) APPEAR IN THEARCHITECTURAL DRAWINGS OR NOTES, REFER TO DOCUMENTSPREPARED BY THE CORRESPONDING CONSULTANTS OR ENGINEERS.(BELOW RIGHT).. "MECHANICAL" REFER TO MECHANICAL DOCUMENTS. "ELECTRICAL" REFER TO ELECTRICAL DOCUMENTS. "PLUMBING" REFER TO PLUMBING DOCUMENTS
G. DETAILS: DETAILS MAY BE REFERENCED BY SYMBOL OR BY "NOTES TOSHEET" REFERENCES. KEYED OR NOTED DETAILS REPRESENT THEDESIRED CONFIGURATION AND FINISHES FOR ALL SIMILAR CONDITIONS.
H. SCHEDULES: FOR ROOM FINISHES, SEE "FINISH SCHEDULE(S)" LOCATEDIN SPECIFICATION DIVISION 09. FOR DOOR AND FRAME OPENINGS SEE“OPENING SCHEDULE(S)” LOCATED IN SPECIFICATION DIVISION 08.
I. EXISTING CONDITIONS: ONLY THE AREAS DESCRIBED IN THE PROJECTSCOPE HAVE BEEN FIELD VERIFIED. "FIELD VERIFIED" MEANS THATEXISTING PARTITIONS HAVE BEEN PARTIALLY LOCATED, MOST OF THEM.E.P. ITEMS HAVE BEEN LOCATED, AND MOST OF THE ARCHITECTURALELEMENTS LOCATED. AREAS THAT ARE CONCEALED OR OTHERWISENOT ACCESSIBLE HAVE NOT BEEN VERIFIED. OTHER AREAS IN THEBUILDING NOT IN THE PROJECT SCOPE HAVE NOT BEEN FIELD VERIFIED.THE PARTITIONS SHOWN IN THE RENOVATED AREAS ARE DERIVED FROMOWNER PROVIDED DOCUMENTS. THE EXISTING SMOKE COMPARTMENTSQUARE FOOTAGES ARE DERIVED FROM OWNER PROVIDEDDOCUMENTS. REVISIONS TO THESE SQUARE FOOTAGES ARE BASED ONTHIS INFORMATION.
J. THE NOTE "NO WORK IN THIS AREA OR COMPARTMENT" IS A GENERALSTATEMENT. SOME M.E.P. WORK AND ARCHITECTURAL WORK MAY BEREQUIRED IN THESE AREAS TO COMPLETE A SYSTEM TO OPERATIONALSTATUS. THESE AREAS MAY REQUIRE MINOR RENOVATION, TOUCH UPWORK, OR REPAIRS DUE TO VERIFICATION OF EXISTING CONDITIONS (I.E.PREVIOUSLY INACCESSIBLE AREAS) PERTINENT TO THE SCOPE OFWORK.
K. OWNER FURNISHED OWNER INSTALLED ITEMS NOTED ON THE PLANSARE PROVIDED UNDER SEPARATE CONTRACT AND ARE SHOWN FORGENERAL INFORMATION ONLY. THE GENERAL CONTRACTOR ISRESPONSIBLE FOR ALL REQUIRED ROUGH-IN AND FINAL CONNECTIONSAT WALLS, FLOORS, AND CEILINGS AS INDICATED ON THECONSTRUCTION DOCUMENTS.
SHEET INDEXSHEET NO. SHEET NAME VOLUME
A0.0 COVER VOLUME 1A0.1 GENERAL INFORMATION & LIFE SAFETY PLANS 1A0.2 OPENING SCHEDULES & TYPES, PARTITION TYPES, & STANDARD
DETAILS1
AD1.1 DEMOLITION FLOOR PLANS 1AD1.2 DEMOLITION REFLECTED CEILING PLANS 1A2.1 ENLARGED RENOVATION FLOOR PLANS 1A3.1 RENOVATION REFLECTED CEILING PLANS 1MD201 LEVEL 05-HVAC DEMO PLAN 1MD202 LEVEL 06 - HVAC DEMO PLAN 1M201 LEVEL 05 - HVAC RENO PLAN 1M202 LEVEL 06 - HVAC RENO PLAN 1ED201 LEVEL 05 - POWER DEMO PLAN 1ED202 LEVEL 05 - POWER DEMO PLAN 1ED301 LEVEL 05 - LIGHTING DEMO PLAN 1ED302 LEVEL 06 - LIGHTING DEMO PLAN 1E201 LEVEL 05 - POWER RENO PLAN 1E202 LEVEL 06 - POWER RENO PLAN 1E301 LEVEL 05 - LIGHTING RENO PLAN 1E302 LEVEL 06 - LIGHTING RENO PLAN 1E401 ELECTRICAL SCHEDULES AND ONE-LINE DIAGRAM 1COVER KI COVER VOLUME 2 22 FLOOR PLAN 23 LEGEND 24 CONNECTOR PLAN 2
A6 REFERENCE SYMBOLS
D5 GENERAL NOTES TO PROJECT
A1 DRAWING INDEX
C1 PROJECT AREA SUMMARY
B1 FIRE AND SMOKE LEGEND
1" = 30'-0"A3 WORK AREA PLAN - LEVEL 6 1" = 30'-0"A5 WORK AREA PLAN - LEVEL5
1/16" = 1'-0"D4 LIFE SAFETY PLAN - L5
1/16" = 1'-0"B4 LIFE SAFETY PLAN - L6
NN
CODE SUMMARY
Project Address 6901 Bertner, Houston, TX 77030
Applicable codes and ordinances 2006 International Building Code (with City of HoustonAmendments)2006 International Fire Code2006 Mechanical Code2006 Plumbing Code2011 National Electric Code2009 International Energy Conservation Code2012 Texas Accessibilty Standards
Occupancy Classification: Business Gruop B
Construction Type: Type II-A
Area: 24,200 sf/per floor194,000 sf total building
Renovated Area Levle 5 2876 sf / Level 6 371sfTravel Distance: 300'-0"
Dead End Corridor 50'-0"
Shaft Enclosures: 1 HR
Occupancy Separation Not Required
Fire Protection Systems: Sprinkled
DEAN'S OFFICE RENOVATION AREA (SQ FT)LEVEL 5 NORTHEASTOFFICE 534A 132OFFICE 534B 104OFFICE 545A 104OFFICE 545B 104OFFICE 549C 146CORRIDOR 549B 100OFFICE 544 112OFFICE 549A 116
LEVEL 5 SOUTHEASTOFFICE 584C 119OFFICE 584B 114OFFICE 586 115OFFICE 594B 140OFFICE 584A 456OFFICE 594A 142
LEVEL6LEARNING RESOURCE CENTER 510 371
TOTAL 2,375*AREA SQUARE FOOTAGECALCULATIONS ARE APPROXIMATE.
NN
20.6L1AS
3.3S
3.3S
3.3S
20.3
L1B
2.3
2.3
20.6L1A
20.6
L1B
20.6L1A
TYPICAL PARTITION
PARTITION TYPE REFERENCE
UNBALANCED PARTITION SUFFIXSOUND RATED PARTITION
LEAD LINED SUFFIXSTUD OR CMU SIZEPARTITION TYPE
.6 = 6" STUDS OR CMU
.8 = 8" CMU
.12 = 12" CMU
PARTITION STUD SIZE LEGEND
.3 = 3 5/8" STUDS
.2 = 2 1/2" STUDS
.1 = 1 5/8" STUDS
.4 = 4" STUDS OR CMU
TYPICAL PARTITIONWITH 3 5/8" STUDS
L = LEAD LINED PARTITION (L1=1/32", L2=1/16",S = SOUND RATED PARTITIONB = SIDE "B" OF UNBALANCED PARTITIONA = SIDE "A" OF UNBALANCED PARTITIONPARTITION SUFFIX LEGEND
ACOUSTICAL PARTITIONWITH 3 5/8" STUDS
ACOUSTICALPARTITION
PARTITIONACOUSTICAL
LEAD LINED PARTITIONLEAD LINEDWITH 6" STUDS, SIDE A
LEAD LINED, SIDE A
SIDE BSIDE ATYPE 3.3S ENTIRE
LENGTH TO NEARESTOUTSIDE CORNERS
DRYWALL PARTITION
MORE THAN 3/8". REMOVESHIMS.
4. METAL STUD @ 16" O.C.FOR SIZE SEE CHART ABOVE.HOLD GYPSUM BOARD 1/4"MIN. ABOVE FLOOR, BUT NOT
5.
GYPSUM BOARD 5/8" THICK.3.
AND HEIGHT.
ANCHOR STUD TRACK TOCEILING SUPPORT GRID @ 24" O.C.
SEE REFLECTED CELING PLANS.2.
SCHEDULED CEILING FINISH1.
FLOOR SLAB.8.
CONDITIONS.SOUND SEAL TAPE.CONTINUOUS UNDERPARTITION HEAD. SEE DETAIL XX/AXX.
7.
CASING BEAD AT ALL6.
STC - NOT TESTED
MAXIMUM.CHANNEL SHAPED STUD RUNNERANCHOR @ 24" O.C. MAXIMUM.
9.
4 7/8"3 5/8"
7 1/4"6"15.6
3 3/4"
PARTITIONTHICKNESSSIZETYPE
15.3
2 1/2"15.2
STUDPART.
BASE
PLAN
HEAD
1
2
3
4
3
9
5
7
8
6
1/2"
MIN
.
BATT INSULATION10.
10
ELEVATION
DOUBLE STUDS REQUIRED AT ALLOPENINGS. LOCATE SECONDSTUD 2" APART, THROAT TOTHROAT WITH JAMB STUDS.JAMB STUD. DOUBLE STUDABOVE FRAME HEAD. LOCATE1/2" APART. WEB TO WEB. SEE"GENERAL NOTES TOPARTITIONS" FOR ADDITIONALDETAIL REFERENCES.FOR FRAME AT HEAD & DETAILREFERENCES, SEE DOOR & OPENINGSCHEDULE AND FRAME TYPES.
FOR FRAME AT JAMB & DETAILREFERENECES, SEE DOOR OPENINGSCHEDULES AND FRAME TYPES.SCHEDULED BASE FINISH.SCHEDULED FLOOR FINISH.FOR OPENING REQUIREMENTS,SEE DOOR & OPENING SCHEDULE.
1.
2.
3.
4.
5.
6.7.8.
C10
11Z
SCHEDULED CEILING FINISH.SEE REFLECTIVE CEILING PLANFOR HEIGHT.
2 3
4
2
1
67
5
8
5/8"
5/8"
2"MAX.
2"MAX.
A. HEAD B. ADJACENT JAMBS
C. JAMB/PARTITION
FOR FRAME THROAT REQUIREMENTSSEE PARTITION TYPE REFERENCE.PARTITION INTERSECTION ATCEILING. SEE PART TYPE.SCHEDULED CLG. FINISH & HEIGHT.SCHEDULED FRAME MATERIAL &SIZE. SEE DOOR & OPENING SCHED.FRAME PROFILE - SEE OPENINGTYPES FOR DIMENSION.FRAME RABBIT-EQUAL ON BOTH SIDESOF STOP.PARTITION HEADER TRACK.CONTINUOUS ACROSS OPENING.SCHEDULED DOOR SIZE & MATERIAL.STUD REQUIRED @ THIS LOCATION
REGARDLESS OF SCHEDULED SPACING.JAMB STUDS-20 GA. MINIMUMUNLESS HEAVIER STUDS SPECIFIED.FRAME ANCHOR. CONCEALEDANCHORAGE REQUIRED.SCHEDULED OPENING WIDTHABUTTING PARTITION. 4" MIN.BACKSET UNLESS OTHERWISENOTED. IF LESS THAN 4"PENETRATION PARTITIONFRAMING REQUIRED.PARTITION INTERSECTION-SEEGENERAL NOTES TO PARTITIONTYPES FOR DETAIL REFERENCE.
1.
2.
3.4.
5.
6.
7.
8.9.
10.
11.
12.13.
14.
C10
20
12
56
2
3
4
8
7
13 131
9 10 104
11
12 1314
149
AL-1
FIN. FL.
2"SC
HED
. DO
OR
HT.
2" SCHED.WIDTH
2"
INTERIOR
FIN. FL.
FULL GLASS
SCHED.WIDTH
10"
SCH
ED. D
OO
R H
T.
5"
5" 5"
(ALUMINUM)
AL-2
FIN. FL.6"
SCH
ED. D
OO
R H
T.2'-0" SCHED.
WIDTH2"
2"
20.5
"
SCHED. WIDTH
SCH
ED. D
OO
R H
T.
DP-10
SURFACE SLIDER DOORS(SLIDING)
G2
G2
FG
G1.
ROOMSIGNAGE
A
1010
1012
1011
1009
1015
1008
1016
1010
1013
1008
1008
605
1017
1018
1001
0' -
4"0'
- 6"
0' -
2"
1013
1008
1010
10111009
3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"
G2 G2
G1
AA.1
2' -
4"7'
- 8"
3' - 0" 3' - 0" 3' - 0" EQEQ.
G1
EXISTING WALL SYSTEM
ACOUSTICAL TAPE
L-BEADSCHEDULED PARTITION
DOUBLE SIDED TAPE
ALUMINUM CAP(TO MATCH MULLION)
WINDOW WALL SYSTEM
SECTION @ PANEL
SECTION @ WINDOW
5/16" ACOUSTICAL TAPE
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
45009.0000
OPENING SCHEDULES& TYPES, PARTITIONTYPES, & STANDARDDETAILS
A0.2
SCHOOL OF NURSINGLEVELS 5 & 6 OFFICESUITE RENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
A. PARTITION TYPES: THE FLOOR PLANS ARE USED TO DESIGNATE THELOCATIONS OF INDIVIDUAL PARTITION TYPES. THE SUFFIX LETTER "A" OR "B"FOLLOWING THE PARTITION TYPE NUMBER INDICATES UNBALANCED PARTITIONCONSTRUCTION REQUIRING DIFFERENT MATERIALS ON EACH FACE OFPARTITION. REFER TO THE PARTITION TYPE REFERENCING EXAMPLE, DETAILC5/A.02 FOR THE GRAPHIC ILLUSTRATION OF HOW THE PARTITIONS AREIDENTIFIED ON THE FLOOR PLANS.
G. PLAN DIMENSIONS: PARTITIONS ARE LOCATED ON THE FLOOR PLANS TO THEFINISH FACE OF THE PARTITION (I.E. FACE OF GYPSUM BOARD OR CONCRETEMASONRY UNIT). APPLIED FINISHES SUCH AS WOOD TRIM, PANELING, ANDCERAMIC TILE ARE APPLIED TO FACE OF THE PARTITION AND ARE NOTINCLUDED IN THE PLAN DIMENSIONS.
H. IF NECESSARY, FOR CONTINUITY OF FACE PLANES OF PARTITIONS, PROVIDEADDITIONAL LAYER(S) OF GYPSUM BOARD, THICKER STUDS, FURRING, OROTHER APPROVED MEANS TO ACCOMPLISH THESE REQUIREMENTS WITHOUTREDUCING THE PHYSICAL EFFECTS OF THE SCHEDULED PARTITION TYPE.
K. ALL CORRIDOR PARTITIONS TO BE CONSTRUCTED TO RESIST THE PASSAGE OFSMOKE.
L. UNLESS OTHERWISE NOTED ON THE PLANS ALL PARTITIONS ARE TO BEPARTITION TYPE 1.3.
R. ALL STC VALUES GIVEN ARE APPROXIMATE VALUES, BUT INDICATED MINIMUMVALUES ANTICIPATED FOR THAT WALL ASSEMBLY
S. METAL STUD GAUGE ALLOWABLE HEIGHTS BASED ON STUDS AT 16” ONCENTER, 5 PSF LATERAL LOAD WITH AN L/240 ALLOWABLE DEFLECTION. THESCHEDULE BELOW DOES NOT APPLY TO FURRING PARTITION TYPES, ANDDOUBLE STUD PLUMBING CHASE PARTITION TYPES. (METAL STUDS AT FIRERATED PARTITION ASSEMBLIES, 20 GAUGE MINIMUM).
STUD GAUGE STUD SIZE. | 1 5/8" 2 1/2" 3 5/8" 4"6"25 GAUGE | 8'-4" 11'-3" 14'-4" 15'-4"19'-9"20 GAUGE | 9'-8" 12'-10" 16'-5" 18'-4"24'-6"
1. A MINIMUM OF ONE 1/2” LAYER OF GYPSUM BOARD EACH SIDE FULL HEIGHTIS ASSUMED IN THE SCHEDULE ABOVE. (PARTITION TYPES ARE BASED ON 5/8”GYPSUM BOARD, UNLESS OTHERWISE NOTED).2. FOR ALL OTHER CONDITIONS, THE RECOMMENDATIONS OF THE STEEL STUDMANUFACTURER’S ASSOCIATION AND THE STUD MANUFACTURER SHALL BEFOLLOWED.3. ALL METAL STUDS, EXCEPT TRACKS, ARE “C” SHAPES STUDS U.O.N.
1/8" = 1'-0"C6 PARTITION TYPE EXAMPLE
1/8" = 1'-0"D5 TYPE 15 PARTITION ABUTTING CEILING 1/8" = 1'-0"D2 OPENING AT STUD FRAMED PARTITION
1/8" = 1'-0"D4 DOOR HEAD & JAMB AT STUDDED PARTITION
D1 GENERAL NOTES TO PARTITION TYPES
OPENING - DOOR SCHEDULE
ROOM NAMEOPENINGNUMBER
OPENINGFRAME TYPE
HARDWARESET REMARKSWIDTH HEIGHT TYPE MATERIAL
OFFICE SUITE 511 3' - 0" 7' - 6" FG AL-1 EXISTINGOFFICE 535B 3' - 0" 7' - 6" FG AL AL-2 2 1,2OFFICE 535C 3' - 0" 7' - 6" FG AL AL-2 2 1,2OFFICE 535D 3' - 0" 7' - 6" FG AL AL-2 2 1,2CONFERENCE 535E 3' - 0" 7' - 6" FG AL AL-2 2 1,2OFFICE 535G 3' - 0" 7' - 6" FG AL AL-2 2 1,2CONFERENCE 535H 3' - 0" 7' - 6" FG AL AL-2 2 1,2OFFICE 535I 3' - 0" 7' - 6" FG AL AL-2 2 1,2OFFICE 535J 3' - 0" 7' - 6" FG AL AL-2 2 1,2CORRIDOR 549A 2' - 11 1/2" 7' - 6" FG AL AL-1 1 1, WALL SYSTEMOFFICE 549B 3' - 0" 7' - 6" FG AL AL-1 1 1,2OFFICE 580B 3' - 0" 7' - 6" DP-10 EXISTING EXISTING CASED OPENING TO ACCEPT RELOCATED
DOOROFFICE 580C 3' - 0" 7' - 6" DP-10 EXISTING EXISTING CASED OPENING TO ACCEPT RELOCATED
DOOROFFICE 580D 3' - 0" 7' - 6" DP-10 EXISTING EXISTING CASED OPENING TO ACCEPT RELOCATED
DOOROFFICE 580E 3' - 0" 7' - 6" DP-10 EXISTING EXISTING CASED OPENING TO ACCEPT RELOCATED
DOOROFFICE 580F 3' - 0" 7' - 6" DP-10 EXISTING EXISTING CASED OPENING TO ACCEPT RELOCATED
DOORLEARNING RESOURCECENTER
620 2' - 10 3/4" 7' - 6" FG AL STOREFRONT 1 1,2
C3 DOOR SCHEDULE
A. FOR FRAME THROAT REQUIREMENTS, SEE "PARTITION TYPES" AND PARTITIONREFERENCES ON FLOOR PLANS OR FIELD VERIFY EXISTING PARTITIONTHICKNESS. SEE REFERENCED DETAILS FOR REQUIRED ANCHORAGE.
B. FRAME TYPE: SEE "CODE TO OPENING SCHEDULE" FOR DEFINITION OFDESIGNATIONS IN "OPENING TYPE" COLUMN. THE SCHEDULED FRAME TYPEDEFINES THE CONFIGURATION OF THE OPENING AND INDICATES DETAILREFERENCES.
C. OPENING SIZE: FRAMED OPENINGS – THE TOTAL WIDTH OF THE OPENING ISTHE FRAME DIMENSION (PROFILE) ADDED TO SCHEDULED DOOR SIZE. SEEREFERENCED DETAILS FOR RELATION OF FRAME SIZE TO ACTUAL SIZE OFWALL OR PARTITION OPENING. SEE FLOOR PLANS FOR GLAZED OPENINGWIDTHS.
D. SEE CODE TO FINISH SCHEDULE CONTAINED ON THE "FINISH SCHEDULE" ORTHE INTERIOR DESIGN DRAWINGS FOR DEFINITION OF HARDWOOD SPECIES,PAINT COLORS AND PLASTIC LAMINATE COLORS.
G. SEE "CODE TO OPENING SCHEDULE" FOR DOOR, FRAME, AND TRANSOMMATERIAL ABBREVIATIONS.
H. THE CLEARANCE BETWEEN THE FLOOR AND THE BOTTOM OF THE DOOR ATFIRE RATED DOORS SHALL NOT EXCEED LIMITS SET BY THE APPLICABLECODES. THE CLEARANCE BETWEEN THE FLOOR AND THE BOTTOM OF THEDOOR ON NON-RATED DOORS SHALL NOT EXCEED 3/4”.
I. ALL GRAPHICS INDICATED WILL BE DETAILED, FURNISHED AND INSTALLED BYOWNERS GRAPHICS SUPPLIER (NIC).
J. DOOR AND WINDOWS IN EXIT ENCLOSURES MUST MEET IBC 714.2.4: "THEMAXIMUM TRANSMITTED TEMPERATURE END POINT SHALL NOT EXCEED 450DEGREES F, ABOVE AMBIENT TEMPERATURE AT THE END OF 30 MINUTES OFTHE FIRE EXPOSURE OF STANDARD FIRE TEST EXPOSURE."
K. ALL DOORS AT SMOKE BARRIERS AND PRESSURIZED STAIR ENCLOSURESSHALL HAVE SMOKE SEAL GASKETS AT THE HEAD AND JAMB.
C1 GENERAL NOTES TO OPENING SCHEDULE
1/8" = 1'-0"C5 OPENING & FRAME TYPES
1. G2 GLAZING AT DOOR2. ALL DOORS TO RECEIVE ROOM SIGNAGE TO MATCH EXISTING
1 1/2" = 1'-0"A4 PARTITION ABUTTING PERIMETER 1 1/2" = 1'-0"A3 SECTION AT SIDELITE
1 1/2" = 1'-0"A2 PARTITION AT PERIMETER MULLION 1/4" = 1'-0"A1 INTERIOR ELEVATION L6
1/4" = 1'-0"B1 OFFICE TRANSOM 1 1/2" = 1'-0"B2 PARTITION AT WALL SYSTEM
NOTES TO SHEET605 SCHEDULED CEILING.1001 METAL STUD FRAMING, (SIZE).1008 PARTITION AS SCHEDULED, SEE PLAN.1009 EXISTING EXTERIOR WALL ASSEMBLY.1010 EXISTING WINDOW SYSTEM.1011 EXISTING SOLID SURFACE SILL CAP.1012 EXISTING SPACE HEATER.1013 EXTRUDED ALUMINUM VERTICAL CLOSURE, MATCH WINDOW FINISH.
SEE SPECIFICATIONS1015 EXISTING ACCESS FLOORING SYSTEM.1016 CONTINUOUS SILICON BEAD AROUND SILL PENETRATION.1017 INTERIOR ALUMINUM STOREFRONT SYSTEM, MATCH EXISTING FINISH.1018 GLASS TRANSOM.
D03
D03
D03D03
D01 D01
D05D05
7 8
A
B
A.1
A.9
D04D04
D05
D04
D06
D06D06
D06
D05
D02
2 3 4
A
B
A.1
A.9
D01
D01 D01
D03
D03
D03
D03
D03
D04 D04 D04
D07
D06
D05D05
D06
D10
D10
D08
TYP.
D01
D01
D01
1 2
D
D06
D05
D02
INDICATES NO WORK IN THISAREA OR COMPARTMENT.
EXISTING WALL TO REMAIN.
TO BE DEMOLISHED.
NEW DRYWALL PARTITION. SEE GENERALNOTES TO PARTITION TYPES.
NEW WALL SYSTEM PANEL
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
45009.0000
DEMOLITION FLOORPLANS
AD1.1
SCHOOL OF NURSINGLEVELS 5 & 6 OFFICESUITE RENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/4" = 1'-0"D3 ENLARGED DEMOLITION FLOOR PLAN - L5 SOUTHEAST 1/4" = 1'-0"D6 ENLARGED DEMOLITION FLOOR PLAN - L5 NORTHEAST
1/4" = 1'-0"B6 ENLARGED DEMOLITION PLAN - L6
A. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS.B. DEMOLITION QUANTITIES ARE UNCLASSIFIED EXCEPT WHERE
EXISTING CONSTRUCTION IS GRAPHICALLY DESIGNATED OR NOTEDTO REMAIN. WHERE PARTITIONS, CEILINGS, FLOORS ETC. ARESHOWN TO BE REMOVED, DEMOLITION SHALL BE INCLUSIVE OF MEPSERVICES/UTILITIES CONTAINED WITHIN, UNLESS SCHEDULED ORNOTED TO REMAIN OR BE EXTENDED. FOR ADDITIONAL DEMOLITIONAND SALVAGE REQUIREMENTS SEE CIVIL, STRUCTURAL,MECHANICAL, ELECTRICAL AND PLUMBING DOCUMENTS. SEE NEWCONSTRUCTION DOCUMENT TIE-INS TO EXISTING SYSTEMS,SERVICES AND MATERIALS TO FULLY DETERMINE ACTUALDEMOLITION LIMITS.
C. THE OWNER RESERVES THE RIGHT TO RETAIN THE FOLLOWINGSALVAGE ITEMS, IF SO NOTIFIED (AND IF NOT SPECIFICALLYINCORPORATED OR REUSED IN THIS PROJECT). CAREFULLYREMOVE, TAG, TRANSPORT, AND STORE IN OWNER DESIGNEDSTORAGE SPACE (ON CAMPUS) THE FOLLOWING ITEMS:1. ELECTRICAL AND, PLUMBING FIXTURES AND DEVICES2. DOORS, FRAMES, AND HARDWARE3. MECHANICAL GRILLS/DIFFUSERS4. WALL FURNITURE SYSTEM5. MILLWORK AND CASEWORK UNITS6. SHOULD THE OWNER DECLINE TO ACCEPT AND PROVIDE STORAGEFOR ANY OF THE ABOVE, THEY SHALL BE COME PROPERTY OF THECONTRACTOR, AND MUST BE PROMPTLY REMOVED FROM THE SITE.
D. REMOVE ALL ATTACHMENTS FOUND ON PARTITION FACES ANDCEILINGS, AND TURN OVER TO OWNER, I.E. SURFACE MOUNTEDTOILET ACCESSORIES, (SOAP DISPENSERS) CUBICLE CURTAINTRACKS, TV WALL MOUNTING BRACKETS, ETC.
E. REMOVAL OF ANY ANTENNAS OR COMPUTER AND TELEPHONE CABLEAND/OR SYSTEM BOARDS MUST BE COORDINATED AND SCHEDULEDWITH THE OWNER.
F. PROTECT BY APPROPRIATE MEANS ALL EXISTING CONSTRUCTION,FINISHES, AND EQUIPMENT THAT IS TO REMAIN. ALL DAMAGEDITEMS/FINISHES MUST BE REPAIRED/RESTORED TO THEIR ORIGINAL(PRE-DAMAGED) CONDITION.
G. DEMOLITION REQUIRING AIR HAMMERS OR OTHER LOUD NOISEGENERATING EQUIPMENT MUST BE CAREFULLY COORDINATED ANDSCHEDULED WITH THE OWNER. WORKING HOURS FOR SUCHACTIVITY WILL BE RESTRICTED.
H. ALL PENETRATIONS FOUND IN EXISTING CHASES AND FIRE-RATEDPARTITIONS OR SHAFTS, NOT SPECIFICALLY CALLED OUT, MUST BEPATCHED/FIRE-SAFED TO MEET THE REQUIRED FIRE ASSEMBLYRATING.
I. REFER TO MEP DEMO DRAWINGS FOR FLOOR DIFFUSER SALVAGENOTES.
J. AFTER REMOVAL OF EXISTING CONSTRUCTION OR FINISHES, PATCHOR REPAIR EXISTING SUBSTRATES REMAINING AS REQUIRED TORECEIVE THE SCHEDULED FINISH.
K. REFER TO WALL SYSTEM DRAWINGS FOR DEMOLITION OF SYSTEM.L. REPLACE DAMAGED ACCESS FLOORING AS REQUIRED.
A5 GENERAL NOTES TO DEMOLITION
NOTES TO SHEETD01 SALVAGE FOR REUSE: DOOR FRAME, DOOR, AND HARDWARE.D02 REMOVE FLOORING & BASE THROUGHOUT SCOPE OF WORK.D03 REMOVE EXISTING PARTITION PANELS. SEE RENOVATION PLAN FOR
EXTENTS OF DEMOLITION.D04 RELOCATE EXISTING FLOOR MOUNTED ELECTRIC HEATER. RE: MECH
DWGD05 REMOVE BLINDS.D06 RELOCATE EXISTING FLOOR MOUNTED SUPPLY GRILLES. RE: MECH
DWG.D07 REMOVE EXISTING CASEWORK AND RETURN TO OWNER.D08 REMOVE PLUG MOLD & LIGHTING FROM WALL SYSTEM.REPLACE WITH
BLANK WALL SYSTEM COVER.D10 FURNITURE TO BE REMOVED AND RETURNED TO OWNER
A6 PROJECT LEGEND1/4" = 1'-0"
N N
N
SF6
FEC3
7 8
A
B
A.1
A.9
D11
D12 D12 D12
D13 D13
D13
D13 D13
23 4
A
B
A.1
A.9
D11
D12 D12
D13
D12
D13 D13
D12 D12
D13
D13 D13
1 2
D
D11 D12
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
45009.0000
DEMOLITIONREFLECTED CEILINGPLANS
AD1.2
SCHOOL OF NURSINGLEVELS 5 & 6 OFFICESUITE RENOVATION
95% CONSTRUCTIONDOCUMENTS
09/29/15
1/4" = 1'-0"D3 DEMOLITION REFLECTED CEILING PLAN - L5 SOUTHEAST 1/4" = 1'-0"D6 DEMOLITION REFLECTED CEILING PLAN - L5 NORTHEAST
1/4" = 1'-0"B6 DEMOLITION REFLECTED CEILING PLAN - L6
NOTES TO SHEETD11 REMOVE LIGHT FIXTURE AND SALVAGE FOR REUSE.D12 CEILING GRID TO REMAIN. REMOVE TILES AS REQUIRED TO ACCESS
ABOVE CEILING. REPLACE DAMAGED TILES.D13 REMOVE EXISTING CEILING MOUNTED RETURN GRILLES AND SALVAGE
FOR REUSE.
10' - 0" 10' - 2 1/2" 11' - 2" 11' - 2"
114 SF
OFFICE580C
125 SF
OFFICE580D
128 SF
OFFICE580E
119 SF
OFFICE580B
150 SF
OFFICE580F
12' -
0"
4' -
0"11
' - 6
"
15.3 15.3 15.3
15.3
1.3
15.3
15.3
446 SF
CONFERENCE580A
7 8
A
B
A.1
580B
580C
580D
580E
580F
15' - 8"
A.9
302
302
302
301 301
303 303
303
303
303
300
A0.2B1
A0.2A2
RB-1
CPT-1
PT-1
PT-1
PT-1
PT-1RB-1
CPT-1
PT-1
PT-1
PT-1
PT-1RB-1
CPT-1
PT-1
PT-1
PT-1
PT-1RB-1
CPT-1
PT-1
PT-1
PT-1
PT-1
RB-1
CPT-1
PT-1
PT-1
PT-1
PT-1RB-1
CPT-1
PT-1
PT-1
PT-1
/DEC
-1
PT-1
2 3 4
A
B
A.1
158 SF
OFFICE535C
124 SF
OFFICE535D
104 SF
OFFICE535E
104 SF
OFFICE535G
146 SF
OFFICE535J
109 SF
CORRIDOR549B
113 SF
CONFERENCE535H 113 SF
OFFICE535I
9' - 11" 9' - 11" 9' - 11"
1' -
1"10
' - 7
"5'
- 4"
11' -
4"15.3 15.3 15.3 15.3
15.3
15.3
15.3
15.3
535H 53
5I
535J
535G
535E
535D
535C
549A
A.9
394 SF
CONFERENCE535A
7' - 6" 10' - 5" 10' - 5"
302 302 302
301301
A0.2A2
14' -
0"
12' - 3 3/4"
92 SF
OFFICE535B
10' - 0"
10' -
0"
A0.2B2
549B
535B
A0.2B2
511
300300
15.3
RB-1
CPT-1PT
-1
PT-1
PT-1
PT-1RB-1
CPT-1
PT-1
PT-1
PT-1
PT-1 RB-1
CPT-1
PT-1
PT-1
PT-1
PT-1
RB-1
CPT-1
PT-1
/DEC
-1 PT-1
PT-1
PT-1
RB-1
CPT-1
PT-1
PT-1
PT-1
PT-1
RB-1
CPT-1
PT-1
PT-1
PT-1
PT-1RB-1
CPT-1
PT-1
PT-1
PT-1
PT-1
RB-1
CPT-1
PT-1
PT-1
PT-1
PT-1
RB-1
CPT-1
PT-1
PT-1
PT-1
PT-1
RB-1
CPT-1
PT-1
/DEC
-1 PT-1
PT-1
PT-1
303ALL WINDOWSIN SCOPE OFWORK
1 2
D
371 SF
LEARNINGRESOURCE
CENTER
620
4' - 10"
19' -
9"
15.3
303303
300 300
A3A0.2
A0.2
A1
620
A0.2A2
RB-1
CPT-1
PT-1
/DEC
-1 PT-1
PT-1
/DEC
-1
PT-1
INDICATES NO WORK IN THISAREA OR COMPARTMENT.
EXISTING WALL TO REMAIN.
TO BE DEMOLISHED.
NEW DRYWALL PARTITION. SEE GENERALNOTES TO PARTITION TYPES.
NEW WALL SYSTEM PANEL
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
45009.0000
ENLARGEDRENOVATION FLOORPLANS
A2.1
SCHOOL OF NURSINGLEVELS 5 & 6 OFFICESUITE RENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/4" = 1'-0"D3 ENLARGED RENOVATION FLOOR PLAN - L5 SOUTHEAST 1/4" = 1'-0"D6 ENLARGED RENOVATION FLOOR PLAN - L5 NORTHEAST
1/4" = 1'-0"B6 ENLARGED RENOVATION PLAN - L6
A. INFORMATION SHOWN OR REFERENCED ON ENLARGED AND/OR 1/4” SCALEDRAWINGS WILL GENERALLY NOT BE SHOWN ON THE SMALLER SCALEDRAWINGS.
B. PARTITION TYPES ARE SCHEDULED ON PLANS BY NUMBER.C. FIELD COORDINATE ALL FIELD ROUTED PIPE, CONDUIT RUNS, ETC., WITH
LOCATIONS OF RECESSED ACCESSORIES AND EQUIPMENT. IN THE EVENTOF A CONFLICT, ACCESSORY LOCATIONS TAKE PRECEDENCE.
D. CLOSE ALL JOINTS BETWEEN PLUMBING FIXTURES/ACCESSORIES ANDDISSIMILAR MATERIALS W/SEALANT (I.E. BETWEEN SINKS ANDCOUNTERTOPS, TOILET FIXTURES AND ACCESSORIES TO WALL, ETC.)
F. PLAN DIMENSIONS ARE TO FINISHED FACE OF PARTITIONS AND GENERALLYARE TIED TO A COLUMN CENTERLINE UNLESS SPECIFICALLY SHOWNCENTERED ON A PARTICULAR BUILDING ELEMENT I.E. A CHASE WALL,WINDOW MULLION, ETC.
N N
N
NOTES TO SHEET300 LEVEL 5 SMOOTH WALL FINISH PREP FOR DRY ERASE COATING
DEC-1.301 NEW WALL SYSTEM PANEL.302 RELOCATED FLOOR MOUNTED ELECTRIC HEATER.303 NEW BLINDS BL-1.
CODE TYPE FINISH PATTERN / STYLE THICKNESS MANUFACTURER COLOR SIZE
ACT-1 ACOUSTICAL CEILING TILE WHITE E (LIGHTLY TEXTURED) 7/8" CHICAGO METALIC WHITE 2'X2'CPT-1 CARPET TILE CHENILLE WARP /
1462902500INTERFACE FLOR 3688 REMEMBRANCE 50CM X 50CM
PT-1 PAINT EGG SHELL BENJAMIN MOORE VERIFY WITH OWNERRB-1 RUBBER BASE TOELESS MATCH EXISTING 6"D-1 DOOR FRAMES DURATEC STARLIGHT SILVERG-1 GLASS 1/4" TEMPERED CLEARG-2 GLASS WITH ETCHING BENDHIEM 1/4" TEMPERED KI-137 SATIN ETCHBL-1 MINI-BLINDS ALUMINUM ALUMINUMDEC-1 DRY ERASE COATING GLOSS SHERWIN WILLIAMS CLEAR
A. ALL FINISHES TO MATCH EXISTINGB. MINI BLINDS TO MATCH EXISTING AT EACH WINDOW IN
RENOVATED AREAE. ALL PAINT TO HAVE EGGSHELL FINISH, UNLESS NOTED
OTHERWISE.H. REFER TO SPECS FOR MARKBOARD FINISH INFORMATION.I. ALL PAINTED WALLS TO RECEIVE PT-1, UNLESS NOTED
OTHERWISE.K. CONTROL JOINTS TO BE PROVIDED EVERY 30'-0"" AT GYP WALLS.
ALIGN WITH DOOR JAMBS WHEN POSSIBLE.N. ALL EXPOSED SCREW HEADS SHALL MATCH ADJACENT
SURFACES UNLESS NOTED ELSEWHERE. ALL GRILLES,REGISTERS, ACCESS DOORS, SPEAKERS, COVER PLATES, FIREEQUIPMENT CABINETS AND ALL OTHER APPLIEDDEVICESREQUIRE JOB FINISH AND SHALL MATCH COLOR OFADJACENT SURFACE, UNLESS OTHERWISE NOTED.
S. ALL CARPET TO BE DIRECT GLUE, UNLESS NOTED OTHERWISE.U. RUBBER TRANSITION STRIPS, UNLESS NOTED OTHERWISE.V. ALL ALUMINUM DOOR FRAMES BAKED ENAMAL FINISH TO MATCH
WALL SYSTEMX. ALL PAINTED FINISHES TO TERMINATE AT INSIDE CORNER,
UNLESS NOTED OTHERWISE.
PT-1
SF6
FEC3
2 3 4
A
B
OFFICE535C
OFFICE535E
OFFICE535J
OFFICE535I
CONFERENCE535H
OFFICE535G
OFFICE535D
CORRIDOR549B
CONFERENCE535A
7 8
A
B
A.1
A.9
OFFICE580B
OFFICE580C
OFFICE580D
OFFICE580E
CONFERENCE580A
OFFICE580F
1 2
D
LEARNINGRESOURCE
CENTER
620
2' X 2' SUSPENDED ACOUSTICAL TILE
RECESSED LED DOWN LIGHT
PENDANT LIGHT
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
45009.0000
RENOVATIONREFLECTED CEILINGPLANS
A3.1
SCHOOL OF NURSINGLEVELS 5 & 6 OFFICESUITE RENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/4" = 1'-0"D6 RENOVATION REFLECTED CEILING PLAN - L5 NORTHEAST
A1 RCP NOTES & LEGEND
1/4" = 1'-0"D3 RENOVATION REFLECTED CEILING PLAN - L5 SOUTHEAST
A. REFER TO "FINISH SCHEDULE" FOR FURTHER DEFINITION OF CEILINGMATERIALS AND FINISHES.
B. CEILING GRID AND TILE TO REMAIN. REPLACE DAMAGED OR STAINED TILEDAS REQUIRED.
C. LOCATE ALL CEILING MOUNTED SMOKE DETECTORS AND SPEAKERS IN THECENTER OF FULL PANELS AT LAY-IN CEILINGS.
D. LOCATE ALL SPRINKLER HEADS IN THE CENTER OF FULL PANELS AT LAY-INCEILINGS. AT GYPSUM BOARD CEILINGS, SYMMETRICALLY SPACE HEADSAND CENTER ON LIGHT ROWS WHERE AREA LIMITATIONS PERMIT.
1/4" = 1'-0"B6 RENOVATION REFLECTED CEILING PLAN - L6
N N
N
HVAC
SHAFT
SHAFT
FEC3
CG CGCG CG
FVC
FVCFVC
FEC1FEC1
DN
UP
UP
DN
OPEN OPEN
DN
UP
FE2 FE2
FEC3
T
T
T
T
T
1 2
3 4
5 67 8
2.2 7.7
A
B
C
D
E
A.1
D.9
A.9
C.1
1(TYP,5)
2 (TYP,7)
3 (TYP,4)
44
2(TYP,3) 3
4
4
5
2 (TYP,6) 2(TYP,6)
3 (TYP,3)
3 3
3(TYP,3)
4
1 1
1444
3 3 35
2 22
5
6
(TYP,7)
(TYP,2) (TYP,2)
(TYP,6)(TYP,6)
(TYP,2) (TYP,2) (TYP,5)
(TYP,2)(TYP,3)
5
5
I N T E R I M R E V I E W O N L Y
Engineer:
Eng. Reg. No.:
permit, or construction purposes.
are not intended for regulatory approval,
are released for interim review only and
These documents are incomplete, and
TX Firm Number:
Date:
Dept. Rep. Date As Shown As Noted
This document represents the conclusion of the departmental
planning for the above indicated design phase of services and
is approved as follows:
CONSTRUCTION DOCUMENTS
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
DEPARTMENT REVIEW
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
Jared R. Machala
100512
F2289
10/30/2015
45009.0000
LEVEL 05 -MECHANICALDEMOLITION PLAN
MD201
SCHOOL OF NURSINGLEVEL'S 5 & 6OFFICE SUITERENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/8" = 1'-0"1
LEVEL 05 - MECHANICAL DEMOLITION PLAN
KEYED NOTES:1 FLOOR MOUNTED ELECTRIC HEATER. RETAIN FOR REUSE IN RENOVATION.
2 RETURN SLOT IN CEILING (24"). RETAIN FOR REUSE IN RENOVATION.
3 UNDERFLOOR VAV BOX. RETAIN FOR REUSE IN RENOVATION.
4 ROUND FLOOR GRILLE. RETAIN FOR REUSE IN RENOVATION.
5 DEMOLISH EXISTING THERMOSTAT AND RETAIN FOR REUSE INRENOVATION. REFER TO RENOVATION PLANS FOR NEW THERMOSTATLOCATIONS.
6 DEMOLISH SINK. REMOVE ALL ASSOCIATED HOT AND COLD WATER PIPING,SANITARY WASTE AND VENT PIPING AND ASSOCIATED HANGERS BACK TOITS NEAREST ACTIVE SOURCE AND CAP. SEAL ALL FLOOR AND WALLPENETRATIONS TO MAINTAIN RATING OF ASSEMBLY AS REQUIRED. CUTAND CAP LAB VACUUM, COMPRESSED AIR, AND LAB WATER BACK AT ITSNEAREST ACTIVE SOURCE.
SHAFT
SHAFT
FVC
FVCFVC
SHAFT
DN
UP
UP
DN
OPEN OPEN
DN
UP
SHAFT
T
1 2
3 4
5 67 8
2.2 7.7
A
B
C
D
E
A.1
D.9
A.9
C.1
1
2
3
4
5
6 7
6
(TYP,4)
(TYP,2)
I N T E R I M R E V I E W O N L Y
Engineer:
Eng. Reg. No.:
permit, or construction purposes.
are not intended for regulatory approval,
are released for interim review only and
These documents are incomplete, and
TX Firm Number:
Date:
Dept. Rep. Date As Shown As Noted
This document represents the conclusion of the departmental
planning for the above indicated design phase of services and
is approved as follows:
CONSTRUCTION DOCUMENTS
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
DEPARTMENT REVIEW
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
Jared R. Machala
100512
F2289
10/30/2015
45009.0000
LEVEL 06 -MECHANICALDEMOLITION PLAN
MD202
SCHOOL OF NURSINGLEVEL'S 5 & 6OFFICE SUITERENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/8" = 1'-0"1
LEVEL 06 - MECHANICAL DEMOLITION PLAN
KEYED NOTES:1 FLOOR MOUNTED ELECTRIC HEATER. RETAIN FOR REUSE IN RENOVATION.
2 RETURN SLOT IN CEILING (24"). RETAIN FOR REUSE IN RENOVATION.
3 UNDERFLOOR VAV BOX. RETAIN FOR REUSE IN RENOVATION.
4 ROUND FLOOR GRILLE. RETAIN FOR REUSE IN RENOVATION.
5 DEMOLISH EXISTING THERMOSTAT AND RETAIN FOR REUSE INRENOVATION. REFER TO RENOVATION PLANS FOR NEW THERMOSTATLOCATIONS.
6 UNDERFLOOR GRILLE TO REMAIN IN CURRENT LOCATION.
7 DEMOLISH SINK. REMOVE ALL ASSOCIATED HOT AND COLD WATER PIPING,SANITARY WASTE AND VENT PIPING AND ASSOCIATED HANGERS BACK TOITS NEAREST ACTIVE SOURCE AND CAP. SEAL ALL FLOOR AND WALLPENETRATIONS TO MAINTAIN RATING OF ASSEMBLY AS REQUIRED. CUTAND CAP LAB VACUUM, COMPRESSED AIR, AND LAB WATER BACK AT ITSNEAREST ACTIVE SOURCE.
HVAC
SHAFT
SHAFT
FEC3
CG CGCG CG
FVC
FVCFVC
FEC1FEC1
DN
UP
UP
DN
OPEN OPEN
DN
UP
FE2 FE2
FEC3
T
T T
T
T
158 SF
OFFICE
535C
124 SF
OFFICE
535D
104 SF
OFFICE
535E
104 SF
OFFICE
535G
146 SF
OFFICE
535J
109 SF
CORRIDOR
549B
113 SF
OFFICE
535I113 SF
CONFERENCE
535H
394 SF
CONFERENCE
535A92 SF
OFFICE
535B
119 SF
OFFICE
580B
114 SF
OFFICE
580C
125 SF
OFFICE
580D
128 SF
OFFICE
580E
446 SF
CONFERENCE
580A
150 SF
OFFICE
580F
1 2
3 4
5 67 8
2.2 7.7
A
B
C
D
E
A.1
D.9
A.9
C.1
1 1 1 1 1
2 2 2 2 2
22
33
3
4 4 4 4 4 33
(TYP,2) (TYP,2) (TYP,2) (TYP,2) (TYP,3)
(TYP,5)(TYP,3) (TYP,3)
(TYP,3) (TYP,5)
2
4 4(TYP,3) (TYP,3)
1 1
1
1
1
2 2 2
2
2
2
3 3 3
3 3
3
4 4
4
4
4
4
(TYP,5) (TYP,5)
(TYP,5)
(TYP,2) (TYP,2)
(TYP,2)
(TYP,2)
4(TYP,3)
(TYP,5)
(TYP,4)
2 2
2
(R)
2
2
1
(R)(R)
(R)(R)
I N T E R I M R E V I E W O N L Y
Engineer:
Eng. Reg. No.:
permit, or construction purposes.
are not intended for regulatory approval,
are released for interim review only and
These documents are incomplete, and
TX Firm Number:
Date:
Dept. Rep. Date As Shown As Noted
This document represents the conclusion of the departmental
planning for the above indicated design phase of services and
is approved as follows:
CONSTRUCTION DOCUMENTS
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
DEPARTMENT REVIEW
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
Jared R. Machala
100512
F2289
10/30/2015
45009.0000
LEVEL 05 -MECHANICALRENOVATION PLAN
M201
SCHOOL OF NURSINGLEVEL'S 5 & 6OFFICE SUITERENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/8" = 1'-0"1
LEVEL 05 - MECHANICAL RENOVATION PLAN
KEYED NOTES:1 FLOOR MOUNTED ELECTRIC HEATER REUSED FROM EXISTING STOCK.
2 FLOOR MOUNTED VAV BOX REUSED FROM EXISTING STOCK. COORDINATE
LOCATION IN FLOOR WITH FURNITURE LAYOUT.
3 ROUND FLOOR MOUNTED SUPPLY GRILLE REUSED FROM EXISTING STOCK.
COORDINATE LOCATION IN FLOOR WITH FURNITURE LAYOUT.
4 24" RETURN SLOT LOCATED IN CEILING GRID REUSED FROM EXISTING
STOCK.
SHAFT
SHAFT
FVC
FVCFVC
SHAFT
DN
UP
UP
DN
OPEN OPEN
DN
UP
SHAFT
371 SF
LEARNING
RESOURCE
CENTER
620
1 2
3 4
5 67 8
2.2 7.7
A
B
C
D
E
A.1
D.9
A.9
C.1
11
2 2
3 3
(TYP,2)(TYP,2)
I N T E R I M R E V I E W O N L Y
Engineer:
Eng. Reg. No.:
permit, or construction purposes.
are not intended for regulatory approval,
are released for interim review only and
These documents are incomplete, and
TX Firm Number:
Date:
Dept. Rep. Date As Shown As Noted
This document represents the conclusion of the departmental
planning for the above indicated design phase of services and
is approved as follows:
CONSTRUCTION DOCUMENTS
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
DEPARTMENT REVIEW
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
Jared R. Machala
100512
F2289
10/30/2015
45009.0000
LEVEL 06 -MECHANICALRENOVATION PLAN
M202
SCHOOL OF NURSINGLEVEL'S 5 & 6OFFICE SUITERENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/8" = 1'-0"1
LEVEL 06 - MECHANICAL RENOVATION PLAN
KEYED NOTES:1 FLOOR MOUNTED ELECTRIC HEATER REUSED FROM EXISTING STOCK.
2 FLOOR MOUNTED VAV BOX REUSED FROM EXISTING STOCK. COORDINATE
LOCATION IN FLOOR WITH FURNITURE LAYOUT.
3 ROUND FLOOR MOUNTED SUPPLY GRILLE REUSED FROM EXISTING STOCK.
COORDINATE LOCATION IN FLOOR WITH FURNITURE LAYOUT.
SHAFT
SHAFT
FVC
FVCFVC
SHAFT
DN
UP
UP
DN
OPEN OPEN
DN
UP
SHAFT
1 2
3 4
5 67 8
2.2 7.7
A
B
C
D
E
A.1
D.9
A.9
C.1
1 1 1 1
2
2
2
2
2
2
2
2
I N T E R I M R E V I E W O N L Y
Engineer:
Eng. Reg. No.:
permit, or construction purposes.
are not intended for regulatory approval,
are released for interim review only and
These documents are incomplete, and
TX Firm Number:
Date:
Dept. Rep. Date As Shown As Noted
This document represents the conclusion of the departmental
planning for the above indicated design phase of services and
is approved as follows:
CONSTRUCTION DOCUMENTS
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
DEPARTMENT REVIEW
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
Jared R. Machala
100512
F2289
10/30/2015
45009.0000
LEVEL 06 - POWERDEMOLITION PLAN
ED202
SCHOOL OF NURSINGLEVEL'S 5 & 6OFFICE SUITERENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/8" = 1'-0"1
LEVEL 06 - ELECTRICAL POWER DEMOLITION PLAN
KEYED NOTES:1 EXISTING RAISED ACCESS FLOOR BOX EQUIPPED WITH (2) DUPLEX
RECEPTACLES AND VOICE/DATA CONNECTIONS TO REMAIN. RECONNECTANY RECEPTACLES DEACTIVED DURING DEMOLITION TO CIRCUIT SERVINGRECEPTACLES PRIOR TO DEMOLITION.
2 DEMOLISH EXISTING RAISED ACCESS FLOOR BOX EQUIPPED WITH (2)DUPLEX RECEPTACLES AND VOICE/DATA CONNECTIONS AND RETAIN FORREUSE IN RENOVATION.
HVAC
SHAFT
SHAFT
FEC3
CG CGCG CG
FVC
FVCFVC
FEC1FEC1
DN
UP
UP
DN
OPEN OPEN
DN
UP
FE2 FE2
FEC3
1 2
3 4
5 67 8
2.2 7.7
A
B
C
D
E
A.1
D.9
A.9
C.1
1 1
2
11 1 1
1
1
1
1
1
1 1
1
1
11
1
1
1
1
3
3
3 3
I N T E R I M R E V I E W O N L Y
Engineer:
Eng. Reg. No.:
permit, or construction purposes.
are not intended for regulatory approval,
are released for interim review only and
These documents are incomplete, and
TX Firm Number:
Date:
Dept. Rep. Date As Shown As Noted
This document represents the conclusion of the departmental
planning for the above indicated design phase of services and
is approved as follows:
CONSTRUCTION DOCUMENTS
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
DEPARTMENT REVIEW
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
Jared R. Machala
100512
F2289
10/30/2015
45009.0000
LEVEL 05 - POWERDEMOLITION PLAN
ED201
SCHOOL OF NURSINGLEVEL'S 5 & 6OFFICE SUITERENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/8" = 1'-0"1
LEVEL 05 - ELECTRICAL POWER DEMOLITION PLAN
KEYED NOTES:1 DEMOLISH EXISTING RAISED ACCESS FLOOR BOX EQUIPPED WITH (2)
DUPLEX RECEPTACLES AND VOICE/DATA CONNECTIONS AND RETAIN FORREUSE IN RENOVATION.
2 DEMOLISH EXISTING RAISED ACCESS FLOOR BOX EQUIPPED WITH DUPLEXRECEPTACLE AND RETURN TO OWNERS STOCK.
3 DEMOLISH EXISTING SURFACE MOUNTED DUAL CHANNEL RACEWAY ANDASSOCIATED CONDUCTORS, CONDUIT, AND EQUIPMENT BACK TO SOURCE.
HVAC
SHAFT
SHAFT
FEC3
CG CGCG CG
FVC
FVCFVC
FEC1FEC1
DN
UP
UP
DN
OPEN OPEN
DN
UP
FE2 FE2
FEC3
OS OS
OS
OS OS OS OS OS
OS
1 2
3 4
5 67 8
2.2 7.7
A
B
C
D
E
A.1
D.9
A.9
C.1
1
1 1 1
1 1
1 1 1
I N T E R I M R E V I E W O N L Y
Engineer:
Eng. Reg. No.:
permit, or construction purposes.
are not intended for regulatory approval,
are released for interim review only and
These documents are incomplete, and
TX Firm Number:
Date:
Dept. Rep. Date As Shown As Noted
This document represents the conclusion of the departmental
planning for the above indicated design phase of services and
is approved as follows:
CONSTRUCTION DOCUMENTS
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
DEPARTMENT REVIEW
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
Jared R. Machala
100512
F2289
10/30/2015
45009.0000
LEVEL 05 - LIGHTINGDEMOLITION PLAN
ED301
SCHOOL OF NURSINGLEVEL'S 5 & 6OFFICE SUITERENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/8" = 1'-0"1
LEVEL 05 - ELECTRICAL LIGHTING DEMOLITION PLAN
KEYED NOTES:1 DEMOLISH EXISTING LIGHTING FIXTURES AND LIGHTING CONTROL
DEVICES AND RETURN TO OWNERS STOCK. DEMOLISH ASSOCIATED
CONDUCTORS, CONDUIT, AND EQUIPMENT BACK TO SOURCE.
SHAFT
SHAFT
FVC
FVCFVC
SHAFT
DN
UP
UP
DN
OPEN OPEN
DN
UP
SHAFT
OS
1 2
3 4
5 67 8
2.2 7.7
A
B
C
D
E
A.1
D.9
A.9
C.1
1
2
2
2
2
I N T E R I M R E V I E W O N L Y
Engineer:
Eng. Reg. No.:
permit, or construction purposes.
are not intended for regulatory approval,
are released for interim review only and
These documents are incomplete, and
TX Firm Number:
Date:
Dept. Rep. Date As Shown As Noted
This document represents the conclusion of the departmental
planning for the above indicated design phase of services and
is approved as follows:
CONSTRUCTION DOCUMENTS
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
DEPARTMENT REVIEW
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
Jared R. Machala
100512
F2289
10/30/2015
45009.0000
LEVEL 06 - LIGHTINGDEMOLITION PLAN
ED302
SCHOOL OF NURSINGLEVEL'S 5 & 6OFFICE SUITERENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/8" = 1'-0"1
LEVEL 06 - ELECTRICAL LIGHTING DEMOLITION PLAN
KEYED NOTES:1 DEMOLISH EXISTING LIGHTING FIXTURES AND LIGHTING CONTROL
DEVICES AND RETURN TO OWNERS STOCK. DEMOLISH ASSOCIATED
CONDUCTORS, CONDUIT, AND EQUIPMENT BACK TO SOURCE.
2 EXISTING CAN DOWNLIGHTS IN THIS ROOM TO REMAIN. RECIRCUIT AND
CONTROL AS INDICATED ON SHEET E302.
HVAC
SHAFT
SHAFT
FEC3
CG CGCG CG
FVC
FVCFVC
FEC1FEC1
DN
UP
UP
DN
OPEN OPEN
DN
UP
FE2 FE2
FEC3
158 SF
OFFICE
535C
124 SF
OFFICE
535D
104 SF
OFFICE
535E
104 SF
OFFICE
535G
146 SF
OFFICE
535J
109 SF
CORRIDOR
549B
113 SF
OFFICE
535I113 SF
CONFERENCE
535H
394 SF
CONFERENCE
535A92 SF
OFFICE
535B
119 SF
OFFICE
580B
114 SF
OFFICE
580C
125 SF
OFFICE
580D
128 SF
OFFICE
580E
446 SF
CONFERENCE
580A
150 SF
OFFICE
580F
1 2
3 4
5 67 8
2.2 7.7
A
B
C
D
E
A.1
D.9
A.9
C.1
1 1 1 1 1
1
1
2
1
1
1 1
1
218"
5LA-4,6
5LA-41
5LB-21,23
5LB-25
1
18"
I N T E R I M R E V I E W O N L Y
Engineer:
Eng. Reg. No.:
permit, or construction purposes.
are not intended for regulatory approval,
are released for interim review only and
These documents are incomplete, and
TX Firm Number:
Date:
Dept. Rep. Date As Shown As Noted
This document represents the conclusion of the departmental
planning for the above indicated design phase of services and
is approved as follows:
CONSTRUCTION DOCUMENTS
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
DEPARTMENT REVIEW
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
Jared R. Machala
100512
F2289
10/30/2015
45009.0000
LEVEL 05 - POWERRENOVATION PLAN
E201
SCHOOL OF NURSINGLEVEL'S 5 & 6OFFICE SUITERENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/8" = 1'-0"1
LEVEL 05 - ELECTRICAL POWER RENOVATION PLAN
KEYED NOTES:1 RELOCATE DEMOLISHED RAISED ACCESS FLOOR BOX EQUIPPED WITH (2)
DUPLEX RECEPTACLES AND VOICE/DATA CONNECTIONS TO LOCATIONINDICATED. COORDINATE VOICE/DATA CONNECTIONS REQUIRED AT NEWLOCATION. RECONNECT RECEPTACLES TO CIRCUIT(S) INDICATED.CONNECT ONE DUPLEX RECEPTACLE TO FIRST CIRCUIT INDICATED, ANDSECOND DUPLEX RECEPTACLE TO SECOND CIRCUIT INDICATED. RELABELREUSED RECEPTACLES TO INDICATE NEW CIRCUIT THAT RECEPTACLESARE FED FROM.
2 RELOCATE DEMOLISHED RAISED ACCESS FLOOR BOX EQUIPPED WITH (2)DUPLEX RECEPTACLES AND VOICE/DATA CONNECTIONS TO LOCATIONINDICATED. COORDINATE VOICE/DATA CONNECTIONS REQUIRED AT NEWLOCATION. RECONNECT RECEPTACLES TO CIRCUIT(S) INDICATED.RELABEL REUSED RECEPTACLES TO INDICATE NEW CIRCUIT THATRECEPTACLES ARE FED FROM.
SHAFT
SHAFT
FVC
FVCFVC
SHAFT
DN
UP
UP
DN
OPEN OPEN
DN
UP
SHAFT
371 SF
LEARNINGRESOURCE
CENTER
620
1 2
3 4
5 67 8
2.2 7.7
A
B
C
D
E
A.1
D.9
A.9
C.1
1 1 1 1
2 2
2 2
6LA-26,30
I N T E R I M R E V I E W O N L Y
Engineer:
Eng. Reg. No.:
permit, or construction purposes.
are not intended for regulatory approval,
are released for interim review only and
These documents are incomplete, and
TX Firm Number:
Date:
Dept. Rep. Date As Shown As Noted
This document represents the conclusion of the departmental
planning for the above indicated design phase of services and
is approved as follows:
CONSTRUCTION DOCUMENTS
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
DEPARTMENT REVIEW
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
Jared R. Machala
100512
F2289
10/30/2015
45009.0000
LEVEL 06 - POWERRENOVATION PLAN
E202
SCHOOL OF NURSINGLEVEL'S 5 & 6OFFICE SUITERENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/8" = 1'-0"1
LEVEL 06 - ELECTRICAL POWER RENOVATION PLAN
KEYED NOTES:1 EXISTING RAISED ACCESS FLOOR BOX EQUIPPED WITH (2) DUPLEX
RECEPTACLES AND VOICE/DATA CONNECTIONS TO REMAIN. RECONNECTANY RECEPTACLES DEACTIVED DURING DEMOLITION TO CIRCUIT SERVINGRECEPTACLES PRIOR TO DEMOLITION.
2 RELOCATE DEMOLISHED RAISED ACCESS FLOOR BOX EQUIPPED WITH (2)DUPLEX RECEPTACLES AND VOICE/DATA CONNECTIONS TO LOCATIONINDICATED. COORDINATE VOICE/DATA CONNECTIONS REQUIRED AT NEWLOCATION. RECONNECT RECEPTACLES TO CIRCUIT(S) INDICATED.CONNECT ONE DUPLEX RECEPTACLE TO FIRST CIRCUIT INDICATED, ANDSECOND DUPLEX RECEPTACLE TO SECOND CIRCUIT INDICATED. RELABELREUSED RECEPTACLES TO INDICATE NEW CIRCUIT THAT RECEPTACLESARE FED FROM.
HVAC
SHAFT
SHAFT
FEC3
CG CGCG CG
FVC
FVCFVC
FEC1FEC1
DN
UP
UP
DN
OPEN OPEN
DN
UP
FE2 FE2
FEC3
VS VS
158 SF
OFFICE
535C
124 SF
OFFICE
535D
104 SF
OFFICE
535E
104 SF
OFFICE
535G
146 SF
OFFICE
535J
109 SF
CORRIDOR
549B
113 SF
OFFICE
535I113 SF
CONFERENCE
535H
394 SF
CONFERENCE
535A92 SF
OFFICE
535B
119 SF
OFFICE
580B
114 SF
OFFICE
580C
125 SF
OFFICE
580D
128 SF
OFFICE
580E
446 SF
CONFERENCE
580A
150 SF
OFFICE
580F
1 2
3 4
5 67 8
2.2 7.7
A
B
C
D
E
A.1
D.9
A.9
C.1
A
C
(N)
(N) C(N)
A(N) A(N) A(N) A(N) A(N) A(N)
A(N) A(N)
D(N) D(N) D(N) D(N)
D(N) D(N)
D(N) D(N)
D(N)
D(N)
D(N)
D(N) D(N)D(N)D(N)
A(N) A(N)A(N)A(N)
A(N) A(N)A(N)
3
V V
V V V
V V
3
V
33
A(N)
VV V V
V
1
2 2 2 2 2
22
32
2 2 2 2
2
3
1
I N T E R I M R E V I E W O N L Y
Engineer:
Eng. Reg. No.:
permit, or construction purposes.
are not intended for regulatory approval,
are released for interim review only and
These documents are incomplete, and
TX Firm Number:
Date:
Dept. Rep. Date As Shown As Noted
This document represents the conclusion of the departmental
planning for the above indicated design phase of services and
is approved as follows:
CONSTRUCTION DOCUMENTS
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
DEPARTMENT REVIEW
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
Jared R. Machala
100512
F2289
10/30/2015
45009.0000
LEVEL 05 - LIGHTINGRENOVATION PLAN
E301
SCHOOL OF NURSINGLEVEL'S 5 & 6OFFICE SUITERENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/8" = 1'-0"1
LEVEL 05 - ELECTRICAL LIGHTING RENOVATION PLAN
KEYED NOTES:1 CONNECT LIGHTING FIXTURES TO 120V, 20A CIRCUIT SERVING AREA PRIOR
TO DEMOLITION. VERIFY LOAD ON CIRCUIT DOES NOT EXCEED 1500VA.
2 FURNISH AND INSTALL WALL-MOUNTED VACANCY SENSOR WHERE
INDICATED TO CONTROL LIGHTING IN SPACE. PROVIDE SEPARATE GROUND
AND NEUTRAL CONDUCTOR FOR VACANCY SENSOR. INSTALL SENSOR IN
LOCATION WHERE DOOR AND FURNITURE WILL NOT CONFLICT WITH
PROPER OPERATION OF SENSOR. CONNECT LIGHTING FIXTURE IN ROOM
TO 120V, 20A LIGHTING CIRCUIT SERVING SPACE PRIOR TO DEMOLITION.
VERIFY LOAD ON CIRCUIT DOES NOT EXCEED 1500VA.
3 FURNISH AND INSTALL CEILING-MOUNTED VACANCY SENSOR WHERE
INDICATED TO CONTROL LIGHTING IN SPACE. PROVIDE SEPARATE GROUND
AND NEUTRAL CONDUCTOR FOR VACANCY SENSOR. INSTALL SENSOR IN
LOCATION WHERE DOOR AND FURNITURE WILL NOT CONFLICT WITH
PROPER OPREATION OF SENSOR. CONNECT LIGHTING FIXTURE IN ROOM
TO 120V, 20A LIGHTING CIRCUIT SERVING SPACE PRIOR TO DEMOLITION.
VERIFY LOAD ON CIRCUIT DOES NOT EXCEED 1500VA.
SHAFT
SHAFT
FVC
FVCFVC
SHAFT
DN
UP
UP
DN
OPEN OPEN
DN
UP
SHAFTVS
VS
371 SF
LEARNING
RESOURCE
CENTER
620
1 2
3 4
5 67 8
2.2 7.7
A
B
C
D
E
A.1
D.9
A.9
C.1
B(N)B(N)
1
I N T E R I M R E V I E W O N L Y
Engineer:
Eng. Reg. No.:
permit, or construction purposes.
are not intended for regulatory approval,
are released for interim review only and
These documents are incomplete, and
TX Firm Number:
Date:
Dept. Rep. Date As Shown As Noted
This document represents the conclusion of the departmental
planning for the above indicated design phase of services and
is approved as follows:
CONSTRUCTION DOCUMENTS
PROJECT NAME
PROJECT NUMBER
ISSUE
DATE
DRAWING TITLE
DRAWING NUMBER
2015 FKP Architects, Inc. All rights reserved. No part of this document may be reproduced or utilized in any form without prior written authorization of FKP Architects, Inc.©
A
B
C
D
E
6 5 4 3 2 1
DEPARTMENT REVIEW
|
ARCHITECT OF RECORD
INTERIM REVIEW ONLY
Not to be used forregulatory approval,permit, or construction.
RICHARD M. HARRIS
DATE:
Houston | Dallas | Columbus
Jared R. Machala
100512
F2289
10/30/2015
45009.0000
LEVEL 06 - LIGHTINGRENOVATION PLAN
E302
SCHOOL OF NURSINGLEVEL'S 5 & 6OFFICE SUITERENOVATION
95% CONSTRUCTIONDOCUMENTS
10/30/15
1/8" = 1'-0"1
LEVEL 06 - ELECTRICAL LIGHTING RENOVATION PLAN
KEYED NOTES:1 CONNECT LIGHTING FIXTURES TO 120V, 20A CIRCUIT SERVING AREA PRIOR
TO DEMOLITION. VERIFY LOAD ON CIRCUIT DOES NOT EXCEED 1500VA.
I N T E R I M R E V I E W O N L Y
Engineer:Eng. Reg. No.:
permit, or construction purposes.are not intended for regulatory approval,are released for interim review only andThese documents are incomplete, and
TX Firm Number:Date:
RICHARD M. HARRIS
Jared R. Machala100512
F228910/27/2015