update of the heating of alfa detector in 2011

11
Update of the heating of ALFA detector in 2011 F. Caspers, P. Fassnacht, A. Grudiev, S. Jakobsen, E. Métral, B. Salvant

Upload: rian

Post on 06-Jan-2016

21 views

Category:

Documents


2 download

DESCRIPTION

Update of the heating of ALFA detector in 2011. F. Caspers, P. Fassnacht, A. Grudiev, S. Jakobsen, E. Métral, B. Salvant. Courtesy Sune Jakobsen et al. Beam intensity. Temperatures in 7R1. Temperatures in 7L1. Beam energy. Detector temperature cannot increase by more than 40 degrees - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Update of the heating of ALFA detector in 2011

Update of the heating of ALFA detector in 2011

F. Caspers, P. Fassnacht, A. Grudiev, S. Jakobsen, E. Métral, B. Salvant

Page 2: Update of the heating of ALFA detector in 2011

Beam intensity

Temperatures in 7L1

Temperatures in 7R1

Beam energy

Courtesy Sune Jakobsen et al

Detector temperature cannot increase by more than 40 degrees Temperature increased by max 18 degrees in 2011 interesting to note that the temperature increase started already at injection

Page 3: Update of the heating of ALFA detector in 2011

ALFASMARTEAM references for the relevant CATIA drawings:• ST0243713_01• ST0040591_02

CST model

Page 4: Update of the heating of ALFA detector in 2011

CST simulations for ALFA• 3D model imported from Catia• Time domain• Ferrite 4s60 model• 40 m wake (100 m for the model with no ferrite)

Page 5: Update of the heating of ALFA detector in 2011

Power spectrum and impedanceM

easu

red

pow

er s

pect

rum

from

Phi

lippe

and

The

mis

Impe

danc

e si

mul

ated

by

CST

in O

hm

Top energy

Page 6: Update of the heating of ALFA detector in 2011

Power loss calculations

1

2 22Re2p

revrevlongrevbloss pMfrumPowerspectpMfZfeMNP

Top energy

Total loss 15W

Page 7: Update of the heating of ALFA detector in 2011

CST eigenmode

Ferrite on the wrong side?

f ~ 0.96 GHzR ~ 23kOhmQ ~ 700

Page 8: Update of the heating of ALFA detector in 2011

CST simulations for ALFA

No ferrite

2 ferrites (current situation)

4 ferrites

Page 9: Update of the heating of ALFA detector in 2011

Power loss at top energy and injection Vs detector gap

Slightly worse at injection smaller loss for bigger gaps

Page 10: Update of the heating of ALFA detector in 2011

Outlook

• Do we need to worry for 2012?– Do we take the detector out?– Cooling (as TOTEM)?– Change location of ferrites?

• What to do to understand more?– Measurements with wire on a bench– Simulations with HFSS

Page 11: Update of the heating of ALFA detector in 2011

TOTEM installed cooling, but when it is off: