    Release UpgradeInstructions

    Release Delivery: (R4.2.2 L5.01)Product Family: (SURPASS)Product: (hiT 7025)Release: (R4.2.2)

    Nokia Siemens Networks Company Confidential 1 (38)

  • 8/9/2019 Upgrade 7025 for R4.2.2

    2/39

    Table of Contents

    ......................................................................................................................................................... 41 Purpose ....................................................................................................................................................... 52 Overview

    .................................................... ........................................................ ...................................... 52.1 Service interruption ...................................................... ........................................................ ........................... 62.2 Management interruption ........................................................ ........................................................ ...................................... 62.3 MIB compatibility

    .................................................................................................................................................. 63 Preparations ................................................. ........................................................ ..................................... 63.1 Material requirements ........................................................ ........................................................ ...................................... 63.2 Hardware Check ...................................................... ........................................................ ......................... 113.3 Backup NE Configuration

    .......................................................... ................................... 113.3.1 Uninstall the old version of TNMS-CT ..................................................... ................................... 123.3.2 Install and start TNMS-CT V3.01. 071.01 .................................................... ............................................. 123.3.3 Setup FTP Service in Windows XP ............................................................ ........................................................ 153.3.4 NE FTP Service set up

    .................................................................................................. 164 Making a safe copy of the active package .................................................. ....................................................... ......................... 164.1 NE MIB Upload and Backup ................................................ ....................................................... ......................... 174.2 Basic NE configuration record .................................................... ........................................................ .................................... 194.3 Alarm Management .................................................. ....................................................... ......................... 194.4 Modify the TP configurations

    ...................................................................................................................... 205 SW downlaoding instructions ....................................................... ........................................................ .................................... 205.1 New NE Software ...................................................... ............................................................ ....... 205.2 NE Software Management Setting ............................................... ........................................................ ................................... 205.3 NE Software Download

    ........................................................................................................ 216 Release delivery upgrade instructions ..................................................... ........................................................ .................................... 216.1 Software Switching ........................................................ ....................................................... .......................... 226.2 SCE Card Replacement

    ....................................................... ........................................................ ............... 236.2.1 Warm reboot NE .......................................................... .............................................. 246.2.2 Move CF card from SC to SCE

    ..................................................... 246.2.3 Connect SCE console port with PC COM port with serial cable. ....................................................... 246.2.4 Plug in SCE card into chassis and stop start up process of NE ........................................................... ................................... 256.2.5 Press X and R to warm reboot NE ........................................................... .............................................. 256.2.6 Check the boot image version

    ....................................................... ....................................................... ............................................... 266.3 Reboot NE ........................................................... .............................................. 276.3.1 Warm rebooting NE approach ................................................... ........................................................ 316.3.2 Cold rebooting NE approach

    ........................................................................................................ 337 Checking of the package consistency ........................................................ ........................................................ .................................... 337.1 Alarm verification ................................................ ........................................................ ................................... 337.2 NE Version verification

    ....................................................................................................................................................... 348 Fallback .................................................... ........................................................ ......................... 348.1 Switch to foregone release ............................................... ........................................................ ........................................................ 368.2 Clear MIB .................................................. ........................................................ .............................................. 378.3 Download MIB

    ....................................................... ....................................................... ............................................... 378.4 Switch MIB

    Nokia Siemens Networks Company Confidential 2 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    3/39

    Contact:

    Contact your local Nokia Siemens Networks support

    Summary of changes:

    Date Version Summary of changes

    2010-6-18 1 Draft

    2010-8-3 2 Add cold reboot cards

    Nokia Siemens Networks Company Confidential 3 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    4/39

    1 PURPOSE

    This document provides detailed guideline to carry out the software upgrade of hiT7025 R4.2.2. Itincludes detailed instructions on how to update the TNMS-CT SW and the Element SW to the latestSystem SW versions release (SVR).

    Nokia Siemens Networks Company Confidential 4 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    5/39

    2 OVERVIEW

    This document instructs the steps for upgrading the Node software from SVR 4.1 to SVR 4.2.2, SVR4.1.1 to SVR 4.2.2, SVR 4.2 to SVR 4.2.2 and SVR 4.2.1 to SVR 4.2.2, including the available rollback options.

    2.1 Service interrupt ion

    NE reboot is mandatory during the upgrade. One of the following two approaches should bechosen to reboot

    Warm reboot NE and cold reboot cards as shown below

    Case Release Load Cold reboot cards

    1. XCT [15/5G] w.STM-16/4(S42024-L5470-A1)

    2. 2x STM-1 (S42024-L5484-A1/A2)1 R4.1->R4.2.2

    3. 2x STM1E (W/P) (S42024-L5460-A1)4. 8x FE/L2 (4x VC4) (S42024-L5495-A1)

    1. XCT [15/5G] w.STM-16/4(S42024-L5470-A1)2. 2x STM-1 (S42024-L5484-A1/A2)

    2 R4.1.1->R4.2.23. 2x STM1E (W/P) (S42024-L5460-A1)4. 8x FE/L2 (4x VC4) (S42024-L5495-A1)

    1. 1xGE/T (S42024-L5472-A1/A2)3 R4.2->R4.2.2

    2. 8xFE/T (S42024-L5469-A1/A2)

    N/A4 R4.2.1->R4.2.2

    Table 2.1-1 Reboot Information

    The traffic on those cards will be interrupted for no more than 1 minute in worst scenario.The NE will be offline up to 10 minutes in worst scenario after NE rebooting.

    Cold reboot whole NE to complete the upgrade. The traffic interruption could be up to 5minutes in worst scenario. The NE will be offline up to 10 minutes in worst scenario afterNE reboot.

    Note

    ii Since the upgrade procedure will change R4.1/R4.1.1 SC card to R4.2.2 SCE card, during thisperiod the Ethernet traffic which running on RSTP/MSTP/GVRP will be interrupted since youplug out the SC card. After SCE card has been inserted chassis and R4.2.2 software loadsuccessfully these traffic will be auto recovered.

    Noteii Please note that during SCE card replacement, after press R to warm reboot NE to load new

    R4.2.2 software, following card will be automatically cold rebooted and traffic existed on thesetwo cards will be interrupted.

    Nokia Siemens Networks code Description

    S42024- L5469- A1/A2 8xFE/T(4xVC-4)

    S42024- L5472- A1/A2 1GE /T(4xVC-4)

    Nokia Siemens Networks Company Confidential 5 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    6/39

    2.2 Management interruption

    During the upgrade, the NE management will be offline for max. 30 minutes.

    2.3 MIB compatibi lity

    The MIB structure between hiT 7025 Release 4.1 Load 4.60/ Release 4.1.1 Load 5.02/Release 4.2Load 3.20/Release 4.2.1 Load4.07 and Release 4.2.2 Load 5.01 is compatible..

    3 PREPARATIONS

    3.1 Material requirements

    Before upgrade, following material is required. (Figure 3.1-1 Material requirements)

    Hardware

    CPU Pentium 4 1.7 GHz

    Memory 512 MB

    Hard disk 1000 Mbytes free

    NIC 10/100 Mbps

    CD-ROM 16x Min.

    Communication port At least 1 serial communication port isneeded.

    Software

    OS Windows XP Professional (English Version)

    Windows 2003 Server (English Version)

    Console HyperTerminal (9600 bps)

    New NE software CD SURPASS hiT 7025 Release 4.2.2 Load5.01 CD (P42022-P5142-R42)

    New TNMS-CT software CD TNMS CT RoW P42024-P5106-A5-59

    TNMS CT Embargo P42024-P5106-A35-27

    TNMS CT Embargo Prerequisites P42024-P5106-A38-24

    TNMS-CT V3.01.071.01

    Accessories

    Network 1x cross-over Ethernet cable

    Console 1x console cable(V42256-T6-A20)

    Figure 3.1-1 Material requirements

    3.2 Hardware Check

    It is important that all the NEs hardware versions should be reviewed. In the SURPASS hiT7025R4.2.2 Load 5.01 only following hardware is supported.Contact your next level technical support organization for further assistance, if your circuit packs

    are not listed in following table. (Figure 3.2-1 Hardware version check)

    Nokia Siemens Networks Company Confidential 6 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    7/39

    Nokia Siemens Networks Company Confidential 7 (38}

    S42024-

    L5600- A1 907-00-00110 SCE (Enhanced System Controller)

    09:1011:12

    15

    S42024- L5458- A1 907-00-00006 System Interface 02:02

    S42024- L5470- A1 907-00-00031 XCT [15/5G] w. STM-16/4 04:08

    S42023- L5089- A1 906-00-00017 Chassis Assembly w/o Power Module 7025 01:03

    S42023- L5089- A2 906-00-00063 Chassis Assembly w/o Power Module 7025 for phaseIII 03:05

    S42024- L5477- A1 906-00-00007 Power Module 05:09

    S42024- L5459- A1 906-00-00009 XCT [7G/2.5G] w. STM-4/1 (w. Stratum 3 Clock) 04:05

    V50004- F887- T800 Blandk Compact Flash Card (hiT7025/35/60/65/80)

    S42023- L5104- A1 906-00-00001 Basic Chassis for 7025 01:01

    S42023- L5105- A1 906-00-00005 Backplane for 7025 01:02

    S42023- L5105- A2 906-00-00064 Backplane for 7025 phaseIII 03:03

    S42024- L5474- A1 906-00-00003 Fan Assembly 01:01

    S42024- L5475- A1 400-40-50151 Air Filter 7025 with metal structure (10pcs/1pack) 01:01

    S42024- L5474- A2 906-00-00067 7025 Fan Assembly for phaseIII 02:03

    S42024- L5619- A1 906-00-00068 7025 Fan Circuit Board for phaseIII 03:03

    S42024- L5454- A1 907-00-00010 Dummy Faceplate for L-FC 01:02

    S42024- L5455- A1 907-00-00011 Dummy Faceplate for S-FC 01:02

    S42024- L5457- A1 907-00-00013 Dummy Faceplate for S-EC 01:02

    S42024- L5353- A2 EOW VoIP Phone, ALTESYS

    S42023- L5087- A1 590-00-00039 SURPASS hiT70 XOW 05:06

    S42024- L5355- A1 521-00-00102 DCM G.652 (40km, 6dB)

    S42023- L5108- A1 906-00-00071 SIPAC panel 02:03

    S42024- L5621- A1 906-00-00070 SIPAC panel board 01:02

    S42024- L5484- A1 907-00-00036 2STM-1 04:04

    S42024- L5484- A2 907-00-00119 2xSTM-1 for 55 degree 02:04

    S42024- L5602- A1 907-00-00111 4xSTM-1 07:08

    S42024- L5464- A1 907-00-00022 1STM-4 04:05

    S42024- L5465- A1 907-00-00026 Booster OA (13dBm) 03:04

    S42024- L5466- A1 907-00-00027 Booster OA (15dBm) 03:04

    S42024- L5467- A1 907-00-00033 Booster OA (18dBm) 03:04

    S42024- L5468- A1 907-00-00032 Preamp OA (20dB, w. 1555.75nm filter) 03:04

    S42024- L5479- A1 906-00-00010 21E1 (W/P) 03:03

    S42024- L5480- A1 906-00-00011 21E1 Paddle (75 Ohm) 01:01

    S42024- L5481- A1 906-00-00012 21E1 Paddle (120 Ohm) 01:01

    S42024- L5559- A1 906-00-00052 21E1 Paddle (75 Ohm) for new E1 cable 02:02

    S42024- L5560- A1 906-00-00053 21E1 Paddle (120 Ohm) for new E1 cable 02:02

    S42024- L5460- A1 907-00-00017 2STM-1E (W/P) 02:02

    S42024- L5461- A1 907-00-00018 2STM-1E Paddle 03:04

    S42024- L5462- A1 907-00-00019 3E3/DS3 (W/P) 04:04

    S42024- L5463- A1 907-00-00020 3E3/DS3 Paddle 03:03,05:05

    S42024- L5472- A1 907-00-00023 1GE /T(4xVC-4) 04:04

    S42024- L5472- A2 907-00-00120 1xGE/T for 55 degree 02:03

    S42024- L5495- A1 907-00-00038 8FE/L2 (4xVC-4) 05:06

    S42024- L5469- A1 907-00-00030 8FE/T(4xVC-4) 04:04

  • 8/9/2019 Upgrade 7025 for R4.2.2

    8/39

    Nokia Siemens Networks Company Confidential 8 (38}

    S42024- L5469- A2 907-00-00121 8xFE/T for 55 degree 02:03

    V50017- U3234- K500 090-00-00839 STM-16 Module U16.2, DWDM 1555.75nm

    S42025- L5127- A1 090-00-00701 STM-16 (L16.2 80km E-SFP)

    S42025- L5128- A1 090-00-00700 STM-16 (L16.1 40km E-SFP)

    S42025- L5129- A1 090-00-00699 STM-16 (S16.1 15km E-SFP)

    V50017- U342- K500 090-00-00798 STM-16 (L16.2 80km, 1550nm)

    V50017- U341- K500 090-00-00797 STM-16 (L16.1 40km, 1310nm)

    V50017- U340- K500 090-00-00796 STM-16 (S16.1 15km, 1310nm)

    V50017- U342- K550 STM-16 Module L-16.2/3, EBG

    V50017- U341- K550 STM-16 Module L-16.1, EBG

    V50017- U340- K550 STM-16 Module S-16.1, EBG

    V50017- U442- K550 STM-16 Module L-16.2/3, i-SFP,EBG

    V50017- U441- K550 STM-16 Module L-16.1, i-SFP,EBG

    V50017- U440- K550 STM-16 Module S-16.1,i-SFP EBG

    V50017- U442- K500 STM-16(L16.2 80km i-SFP)

    V50017- U441- K500 STM-16 (L16.1 40km i-SFP)

    V50017- U440- K500 STM-16 (S16.1 15km i-SFP)

    S42025- L5148- A1 090-00-00636 STM-4 (V4.2 120km)

    S42025- L5130- A1 090-00-00696 STM-4 (L4.2 80km E-SFP)

    S42025- L5131- A1 090-00-00695 STM-4 (L4.1 40km E-SFP)

    S42025- L5132- A1 090-00-00694 STM-4 (S4.1 15km E-SFP)

    V50017- U333- K500 090-00-00795 STM-4 (V4.2 120km, 1550nm)

    V50017- U332- K500 090-00-00794 STM-4 (L4.2 80km, 1550nm)

    V50017- U331- K500 090-00-00805 STM-4 (L4.1 40km, 1310nm)

    V50017- U330- K500 090-00-00793 STM-4 (S4.1 15km, 1310nm)

    V50017- U332- K550 STM-4 Module L-4.2/3, EBG

    V50017- U331- K550 STM-4 Module L-4.1, EBG

    V50017- U330- K550 STM-4 Module S-4.1, EBG

    V50017- U337- K550 STM-4 Module L-4.2/3, i-SFP, EBG

    V50017- U336- K550 STM-4 Module L-4.1, i-SFP,EBG

    V50017- U335- K550 STM-4 Module S-4.1, i-SFP,EBG

    V50017- U337- K500 090-00-00815 STM-4 (L4.2 80km i-SFP)

    V50017- U336- K500 090-00-00814 STM-4 (L4.1 40km i-SFP)

    V50017- U335- K500 090-00-00813 STM-4 (S4.1 15km i-SFP)

    S42025- L5149- A1 090-00-00578 STM-1 (V1.2 120km E-SFP) w/ LOS Adjust

    S42025- L5133- A1 090-00-00693 STM-1 (L1.2 80km E-SFP) w/ LOS Adjust

    S42025- L5134- A1 090-00-00692 STM-1 (L1.1 40km E-SFP) w/LOS Adjust

    S42025- L5135- A1 090-00-00691 STM-1 (S1.1 15km E-SFP) w/LOS Adjust

    V50017- U325- K500 090-00-00791 STM-1 (L1.2 80km, 1550nm)

    V50017- U324- K500 090-00-00790 STM-1 (L1.1 40km , 1310nm)

    V50017- U323- K500 090-00-00789 STM-1 (S1.1 15km, 1310nm)

    V50017- U325- K550 STM-1 (L1.2 80km, 1550nm),EBG

    V50017- U324- K550 STM-1 (L1.1 40km , 1310nm),EBG

    V50017- U323- K550 STM-1 (S1.1 15km, 1310nm),EBG

    V50017- U322- K500 STM-1(L1.2 80km,i-SFP)

    V50017- U321- K500 STM-1(L1.1 40km,i-SFP)

    V50017- U320- K500 STM-1(S1.1 15km,i-SFP)

    V50017- U322- K550 STM-1(L1.2 80km,i-SFP),EBG

  • 8/9/2019 Upgrade 7025 for R4.2.2

    9/39

    Nokia Siemens Networks Company Confidential 9 (38}

    V50017- U321- K550 STM-1(L1.1 40km,i-SFP),EBG

    V50017- U320- K550 STM-1(S1.1 15km,i-SFP),EBG

    V50017- U329- K500 090-00-00678 STM-1E (Electrical SFP)

    S42025- L5136- A1 090-00-00702 GE-ZX (1550nm 80km E-SFP)

    S42025- L5137- A1 090-00-00703 GE (1310nm 35km E-SFP)

    S42025- L5138- A1 090-00-00698 GE-LX (1310nm 10km E-SFP)

    S42025- L5139- A1 090-00-00697 GE-SX (850nm 500m E-SFP)

    V50017- U467- K500 GE (1310nm 35km i-SFP)

    V50017- U461- K500 1G FC/GE Multirate SFP (1310nm,SM 10km)industrial Temp

    V50017- U468- K500 090-00-00723 1G FC/GE Multirate SFP (1550nm,SM 80km)

    V50017- U467- K500 090-00-00724 1G FC/GE Multirate SFP (1310nm,SM 40km)

    V50017- U463- K500 090-00-00725 1G FC/GE Multirate SFP (1310nm,SM 10km)

    V50017- U462- K500 090-00-00726 1G FC/GE Multirate SFP (850nm,MM 500m)

    V50017- U468- K550 090-00-00723 1G FC/GE Multirate SFP (1550nm,SM 80km),EBG

    V50017- U467- K550 090-00-00724 1G FC/GE Multirate SFP (1310nm,SM 40km),EBG

    V50017- U463- K550 090-00-00725 1G FC/GE Multirate SFP (1310nm,SM 10km),EBG

    V50017- U600- K500 090-00-00727 GE Electric SFP (100m, CAT-5)

    V50017- U403- K500 090-00-00781 STM-1 (Bidi 20km, E-SFP,Tx:1310; Rx:1550)

    V50017- U413- K500 090-00-00782 STM-1 (Bidi 20km, E-SFP,Tx:1550; Rx:1310)

    V50017- U402- K500 090-00-00779 GE-LX (Bidi 10km, E-SFP,Tx:1310; Rx:1490)

    V50017- U412- K500 090-00-00780 GE-LX (Bidi 10km, E-SFP,Tx:1490; Rx:1310)

    V50017- U406- K500 GE Bidi SFP, 10km,TX1310nm, RX1490nm,1.25G_622MBp, -40 to 85deg

    V50017- U416- K500 GE Bidi SFP, 10km,TX1490nm, RX1310nm,1.25G_622MBp, -40 to 85deg

    V50017- U407- K500 GE Bidi SFP, 40km,TX1310nm, RX1490nm,1.25G_622MBp, -40 to 85deg

    V50017- U417- K500 GE Bidi SFP, 40km,TX1490nm, RX1310nm,1.25G_622MBp, -40 to 85deg

    V50017- U415- K500 STM-16 (Bidi 40km, E-SFP,Tx: 1570nm; Rx:1490nm, Industrial SFP)

    V50017- U405- K500 STM-16 (Bidi 40km, E-SFP, Tx: 1490nm; Rx:1570nm,Industrial SFP)

    V50017- U414- K500 STM-16 (Bidi 15km, E-SFP,Tx: 1550nm; Rx:1310nm, Industrial SFP)

    V50017- U404- K500 STM-16 (Bidi 15km, E-SFP, Tx: 1310nm; Rx:1550nm,Industrial SFP)

    V50017- U3044- K500 090-00-00757 2.5G DWDM Multirate (1563.86nm,SM 80km)

    V50017- U3043- K500 090-00-00756 2.5G DWDM Multirate (1563.05nm,SM 80km)

    V50017- U3042- K500 090-00-00755 2.5G DWDM Multirate (1562.23nm,SM 80km)

    V50017- U3041- K500 090-00-00754 2.5G DWDM Multirate (1561.42nm,SM 80km)

    V50017- U3040- K500 090-00-00753 2.5G DWDM Multirate (1560.61nm,SM 80km)

    V50017- U3039- K500 090-00-00752 2.5G DWDM Multirate (1559.79nm,SM 80km)V50017- U3038- K500 090-00-00751 2.5G DWDM Multirate (1558.98nm,SM 80km)

    V50017- U3037- K500 090-00-00750 2.5G DWDM Multirate (1558.17nm,SM 80km)

    V50017- U3036- K500 090-00-00749 2.5G DWDM Multirate (1557.36nm,SM 80km)

    V50017- U3035- K500 090-00-00748 2.5G DWDM Multirate (1556.55nm,SM 80km)

    V50017- U3034- K500 090-00-00730 2.5G DWDM Multirate (1555.75nm,SM 80km)

    V50017- U3033- K500 090-00-00747 2.5G DWDM Multirate (1554.94nm,SM 80km)

    V50017- U3032- K500 090-00-00735 2.5G DWDM Multirate (1554.13nm,SM 80km)

    V50017- U3031- K500 090-00-00746 2.5G DWDM Multirate (1553.33nm,SM 80km)

    V50017- U3030- K500 090-00-00745 2.5G DWDM Multirate (1552.52nm,SM 80km)

    V50017- U3029- K500 090-00-00744 2.5G DWDM Multirate (1551.72nm,SM 80km)

    V50017- U3028- K500 090-00-00743 2.5G DWDM Multirate (1550.92nm,SM 80km)V50017- U3027- K500 090-00-00722 2.5G DWDM Multirate (1550.12nm,SM 80km)

  • 8/9/2019 Upgrade 7025 for R4.2.2

    10/39

    Nokia Siemens Networks Company Confidential 10 (38}

    V50017- U3026- K500 090-00-00742 2.5G DWDM Multirate (1549.32nm,SM 80km)

    V50017- U3025- K500 090-00-00741 2.5G DWDM Multirate (1548.51nm,SM 80km)

    V50017- U3024- K500 090-00-00740 2.5G DWDM Multirate (1547.72nm,SM 80km)

    V50017- U3023- K500 090-00-00739 2.5G DWDM Multirate (1546.92nm,SM 80km)

    V50017- U3022- K500 090-00-00738 2.5G DWDM Multirate (1546.12nm,SM 80km)

    V50017- U3021- K500 090-00-00737 2.5G DWDM Multirate (1545.32nm,SM 80km)

    V50017- U3020- K500 090-00-00736 2.5G DWDM Multirate (1544.53nm,SM 80km)

    V50017- U3019- K500 090-00-00758 2.5G DWDM Multirate (1543.73nm,SM 80km)

    V50017- U3018- K500 090-00-00759 2.5G DWDM Multirate (1542.94nm,SM 80km)

    V50017- U3017- K500 090-00-00760 2.5G DWDM Multirate (1542.14nm,SM 80km)

    V50017- U3016- K500 090-00-00761 2.5G DWDM Multirate (1541.35nm,SM 80km)

    V50017- U3015- K500 090-00-00762 2.5G DWDM Multirate (1540.56nm,SM 80km)

    V50017- U3014- K500 090-00-00763 2.5G DWDM Multirate (1539.77nm,SM 80km)

    V50017- U3013- K500 090-00-00764 2.5G DWDM Multirate (1538.98nm,SM 80km)

    V50017- U3012- K500 090-00-00765 2.5G DWDM Multirate (1538.19nm,SM 80km)

    V50017- U3011- K500 090-00-00766 2.5G DWDM Multirate (1537.40nm,SM 80km)

    V50017- U3010- K500 090-00-00767 2.5G DWDM Multirate (1536.61nm,SM 80km)

    V50017- U3009- K500 090-00-00768 2.5G DWDM Multirate (1535.82nm,SM 80km)

    V50017- U3008- K500 090-00-00769 2.5G DWDM Multirate (1535.04nm,SM 80km)

    V50017- U3007- K500 090-00-00770 2.5G DWDM Multirate (1534.25nm,SM 80km)

    V50017- U3006- K500 090-00-00771 2.5G DWDM Multirate (1533.47nm,SM 80km)

    V50017- U3005- K500 090-00-00772 2.5G DWDM Multirate (1532.68nm,SM 80km)

    V50017- U3004- K500 090-00-00773 2.5G DWDM Multirate (1531.90nm,SM 80km)

    V50017- U3003- K500 090-00-00774 2.5G DWDM Multirate (1531.12nm,SM 80km)

    V50017- U3002- K500 090-00-00775 2.5G DWDM Multirate (1530.33nm,SM 80km)

    V50017- U3001- K500 090-00-00776 2.5G DWDM Multirate (1529.55nm,SM 80km)

    C39055- Z1- C199 400-80-80200 Heat Sink for SFP cage

    C39055- Z1- C197 400-80-80199 Heat Sink Clip for SFP cage

    V50017- U3147- K500 090-00-00619 2.5G CWDM E-SFP Multirate @ 1471nm 80km

    V50017- U3149- K500 090-00-00620 2.5G CWDM E-SFP Multirate @ 1491nm 80km

    V50017- U3151- K500 090-00-00621 2.5G CWDM E-SFP Multirate @ 1511nm 80km

    V50017- U3153- K500 090-00-00622 2.5G CWDM E-SFP Multirate @ 1531nm 80km

    V50017- U3155- K500 090-00-00623 2.5G CWDM E-SFP Multirate @ 1551nm 80km

    V50017- U3157- K500 090-00-00624 2.5G CWDM E-SFP Multirate @ 1571nm 80km

    V50017- U3159- K500 090-00-00625 2.5G CWDM E-SFP Multirate @ 1591nm 80km

    V50017- U3161- K500 090-00-00626 2.5G CWDM E-SFP Multirate @ 1611nm 80km

    V50017- U3347- K500 090-00-00627 2.5G CWDM E-SFP Multirate @ 1471nm 40km

    V50017- U3349- K500 090-00-00628 2.5G CWDM E-SFP Multirate @ 1491nm 40km

    V50017- U3351- K500 090-00-00629 2.5G CWDM E-SFP Multirate @ 1511nm 40km

    V50017- U3353- K500 090-00-00630 2.5G CWDM E-SFP Multirate @ 1531nm 40km

    V50017- U3355- K500 090-00-00631 2.5G CWDM E-SFP Multirate @ 1551nm 40km

    V50017- U3357- K500 090-00-00632 2.5G CWDM E-SFP Multirate @ 1571nm 40km

    V50017- U3359- K500 090-00-00633 2.5G CWDM E-SFP Multirate @ 1591nm 40km

    V50017- U3361- K500 090-00-00634 2.5G CWDM E-SFP Multirate @ 1611nm 40km

    DVA:61000091 SFP/2G5U/C1470V/SM/LC

    DVA:61000092 SFP/2G5U/C1490V/SM/LC

    DVA:61000093 SFP/2G5U/C1510V/SM/LC

    DVA:61000094 SFP/2G5U/C1530V/SM/LC

  • 8/9/2019 Upgrade 7025 for R4.2.2

    11/39

    DVA:61000095 SFP/2G5U/C1550V/SM/LC

    DVA:61000096 SFP/2G5U/C1570V/SM/LC

    DVA:61000097 SFP/2G5U/C1590V/SM/LC

    DVA:61000098 SFP/2G5U/C1610V/SM/LC

    DVA:61000161 SFP/2G5U/C1470L/SM/LC

    DVA:61000162 SFP/2G5U/C1490L/SM/LC

    DVA:61000163 SFP/2G5U/C1510L/SM/LC

    DVA:61000164 SFP/2G5U/C1530L/SM/LC

    DVA:61000165 SFP/2G5U/C1550L/SM/LC

    DVA:61000166 SFP/2G5U/C1570L/SM/LC

    DVA:61000167 SFP/2G5U/C1590L/SM/LC

    DVA:61000168 SFP/2G5U/C1610L/SM/LC

    DVA:61704491 SFP/2G5U/C1470V/SM/LC

    DVA:61704492 SFP/2G5U/C1490V/SM/LC

    DVA:61704493 SFP/2G5U/C1510V/SM/LC

    DVA:61704494 SFP/2G5U/C1530V/SM/LC

    DVA:61704495 SFP/2G5U/C1550V/SM/LC

    DVA:61704496 SFP/2G5U/C1570V/SM/LC

    DVA:61704497 SFP/2G5U/C1590V/SM/LC

    DVA:61704498 SFP/2G5U/C1610V/SM/LC

    DVA:61704691 SFP/2G5U/C1470L/SM/LC

    DVA:61704692 SFP/2G5U/C1490L/SM/LC

    DVA:61704693 SFP/2G5U/C1510L/SM/LC

    DVA:61704694 SFP/2G5U/C1530L/SM/LC

    DVA:61704695 SFP/2G5U/C1550L/SM/LC

    DVA:61704696 SFP/2G5U/C1570L/SM/LC

    DVA:61704697 SFP/2G5U/C1590L/SM/LC

    DVA:61704698 SFP/2G5U/C1610L/SM/LC

    Figure 3.2-1 Hardware version check

    3.3 Backup NE Configuration

    3.3.1 Uninstall the old version of TNMS-CTPlease uninstall TNMS-CT if it is older than V3.01.071.01 on your computer.

    Note

    ii If you have configured the parameters in the Monitor Point Filter window (bothSDH PM and Ethernet PM) (Figure 3.3-1 Monitor Point Filter Window), theseconfigurations will be lost after you close and restart TNMS-CT, and you shouldreconfigure it.

    Nokia Siemens Networks Company Confidential 11 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    12/39

    Figure 3.3-1 Monitor Point Filter Window

    3.3.2 Install and start TNMS-CT V3.01. 071.01

    TNMS-CT CD (P42024-P5106-A5-59) contains TNMS-CT V3.01.071.01 software that will be usedfor managing the new release of SURPASS hiT7025.

    3.3.3 Setup FTP Service in Windows XP1. Prepare Windows XP SP2 installation CD. Insert into computer CD/DVD ROM.

    2. Install FTP server. Click StartControl Panel Add/Remove ProgramsAdd/RemoveWindows ComponentInternet Information ServiceDetailsCommon FilesFileTransfer Protocol (FTP) Service . (Figure 3.3-2 Install Windows XP SP2 IIS FTP Service)

    Nokia Siemens Networks Company Confidential 12 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    13/39

    Figure 3.3-2 Install Windows XP SP2 IIS FTP Service

    Nokia Siemens Networks Company Confidential 13 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    14/39

    3. Configure FTP server. Click StartControl PanelAdministrative ToolsInternetInformation Servicexx (local computer) FTP SitesDefault FTP Site. Right-click the

    Default FTP Site, select the FTP properties. Referring to the following configuration in Fig 3.3.3-2,suggest to allow user Anonymous, make sure FTP Site Directory is where the MIB andsoftware Load file located, by default ,it is c:\Inetpub\ftproot. (Figure 3.3-3 Configure IIS FTPService)

    Figure 3.3-3 Configure IIS FTP Service

    4, Test FTP server

    After finish upper procedure, operator should verify the FTP server; click StartRun. Inputftp 127.0.0.1, then a DOS window will open, input anonymous as the user name and anywords in password, input dir to check whether the software load is in the folder. (Figure 3.3-4Verify IIS FTP Service)

    Nokia Siemens Networks Company Confidential 14 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    15/39

    Figure 3.3-4 Verify IIS FTP Service

    3.3.4 NE FTP Service set upThe operator can use the cross-over Ethernet cable to connect to NE directly or use DCN network. Itjust needs to be made sure there is no firewall or TCP/IP port blocking equipment between PC and

    NE.

    Click on ConfigurationNEFTP configuration.Ensure your FTP server has been setup properly.(Figure 3.3-5 NE FTP settings)

    Figure 3.3-5 NE FTP settings

    While username and password should be the same as the configuration of FTP server application, if

    the user is using XP IIS FTP, and setup it according to chapter 3.3.3, the default user name isanonymous, password is any word.

    Nokia Siemens Networks Company Confidential 15 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    16/39

    4 MAKING A SAFE COPY OF THE ACTIVE PACKAGE

    4.1 NE MIB Upload and Backup

    WARNING

    !! Even if the MIB backup has been done before, please use the TNMS-CT V3.01.071.01 to do the MIB backup again.

    Click on ConfigurationNEMIB Management, you will get following window.(Figure 4.1-1 NE MIB upload)

    Figure 4.1-1 NE MIB upload

    test.mib is the file in where the MIB will be stored.

    Then, click upload MIB to upload hiT 7025 MIB from the NE to your local PC. Once theuploading is finished, a message note will be prompted as followsFigure 4.1-2 NE MIB upload successful)(

    Figure 4.1-2 NE MIB upload successful

    Nokia Siemens Networks Company Confidential 16 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    17/39

    4.2 Basic NE configuration record

    Basic NE configuration listed below should be recorded before upgrade. (Figure 4.2-1 NEproperties)Click on configurationNE Property Configuration, you can get following information:

    NE Label

    IP Address

    Gateway

    Figure 4.2-1 NE properties

    Click Print button to save NE Properties as an html file. (Figure 4.2-2 NE properties record list)

    Nokia Siemens Networks Company Confidential 17 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    18/39

    Figure 4.2-2 NE properties record list

    Click on DCNChange Ethernet IP to get: (Figure 4.2-3 Ethernet IP address configuration)

    Current IP Address

    Current Subnet Mask

    Nokia Siemens Networks Company Confidential 18 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    19/39

    Figure 4.2-3 Ethernet IP address configuration

    4.3 Alarm Management

    It is recommended that NE is running alarm-free during the upgrade.

    4.4 Modify the TP configurations

    Noteii Since hiT 7025 R4.2.2 does not support Fixed-1 byte of TI Mode for J1 and J2 bytes please

    modify them to 16-byte or Provisioned 1-byte mode in R4.1 /R4.1.1before you upgrade.Otherwise, after upgrade to hiT 7025 R4.2.2 unexpected compatibility problems will happen.

    Nokia Siemens Networks Company Confidential 19 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    20/39

    5 SW DOWNLAODING INSTRUCTIONS

    5.1 New NE Software

    The SURPASS hiT7025 Release 4.2.2Load 5.01 CD (P42022-P5142-R42) contains the new NErelease software.It is necessary to copy this file from the CD to the FTP folder in your local PC, e.g., the filenameof new release software is PBk1r42b501.bld. Normally the FTP folder is %SystemDrive%\Inetpub\ftproot

    5.2 NE Software Management Setting

    Click on ConfigurationNE software Management, you will get following window. Make surethat the Active Software Version is Release 4.1 Load 4.60 or Release 4.1.1 Load 5.02 orRelease 4.2 Load 3.20 or Release 4.2.1 Load 4.07. (Figure 5.2-1 NE software managementpreparation)

    Figure 5.2-1 NE software management preparation

    5.3 NE Software Download

    Write down the new NE software filename in the software file name field, as Figure 5.2-1 NEsoftware management shows, then click on Download software from FTP Server. It will take 30minutes in worst case to download the new NE software. If the downloading is successful, thefollowing window will pop up: (Figure 5.3-1 NE software downloads successfully)

    Nokia Siemens Networks Company Confidential 20 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    21/39

    Figure 5.3-1 NE software downloads successfully

    6 RELEASE DELIVERY UPGRADE INSTRUCTIONS

    6.1 Software Switching

    Click on Configuration NENE software Management, you will get following window.Make sure that Backup Software Version is Release 4.2.2 Load 5.01. (Figure 6.1-1 NE softwareswitching)

    Figure 6.1-1 NE software switching

    Click on Switch and the following window will pop out, (Figure 6.1-2 NE Software switching(continued))

    Nokia Siemens Networks Company Confidential 21 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    22/39

    Figure 6.1-2 NE Software switching (continued)

    Click on Yes, the value of Status of Last Command will change to Need reboot to accomplishload switch, if switching is successful, TNMS-CT prompts as following, (Figure 6.1-3 Prompt

    window of switching successfully)

    Figure 6.1-3 Prompt window of switching successfully

    6.2 SCE Card Replacement

    Noteii This chapter is only for upgrade from R4.1 to R4.2.2 or R4.1.1 to R4.2.2. If upgrade from R4.2

    to R4.2.2 or R4.2.1 to R4.2.2, please go to chapter 6.3directly.

    Noteii It is important to connect the console cable between SCs serial port and computers COM port

    and make sure the Hyper Terminal is working normally before warm reboot NE.

    Noteii Since the upgrade procedure will change R4.1/R4.1.1 SC card to R4.2.2 SCE card, during this

    period the Ethernet traffic which running on RSTP/MSTP/GVRP will be interrupted since youplug out the SC card. After SCE card has been inserted chassis and R4.2.2 software loadsuccessfully these traffic will be auto recovered.

    Noteii Please note that during SCE card replacement, after press R to warm reboot NE to load new

    R4.2.2 software, following card will be automatically cold rebooted and traffic existed on these

    two cards will be interrupted.

    Nokia Siemens Networks Company Confidential 22 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    23/39

    Nokia Siemens Networks code Description

    S42024- L5469- A1/A2 8xFE/T(4xVC-4)

    S42024- L5472- A1/A2 1GE /T(4xVC-4)

    6.2.1 Warm reboot NEClick on Configuration NEWarm Reboot, you will get following window. Click Yes toexecute warm reboot.

    Keep on watching the Hyper Terminal screen and when the screen displays Press b toconfigure please press b to stop the start up process of NE

    Noteii It is very important to stop the NE start up process below. If you forgetting to stop it please plug

    out the SC card immediately.

    Nokia Siemens Networks Company Confidential 23 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    24/39

    6.2.2 Move CF card from SC to SCE

    First please plug out the SC card from chassis, and then please plug out the Compact FlashCard from SC card and insert it into SCE card.

    6.2.3 Connect SCE console port with PC COM port with serial cable.

    6.2.4 Plug in SCE card into chassis and stop start up process of NE

    When the screen displays Press b to configure please press b to stop the start up process ofNE

    Nokia Siemens Networks Company Confidential 24 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    25/39

    Press F to enter the Boot commands window

    Press 1 to format board flash of SCE card

    6.2.5 Press X and R to warm reboot NE

    6.2.6 Check the boot image version

    Nokia Siemens Networks Company Confidential 25 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    26/39

    Noteii The correct Boot Image for SCE card is 1.8.8.8. If the Boot Image does not correct please

    contact your next level technical support organization for further assistance.

    6.3 Reboot NE

    NE reboot is mandatory during the upgrade. One of the following two approaches should bechosen to reboot

    Warm reboot NE and cold reboot cards as shown below

    Case Release Load Cold reboot cards

    5. XCT [15/5G] w.STM-16/4(S42024-L5470-A1)6. 2x STM-1 (S42024-L5484-A1/A2)

    1 R4.1->R4.2.27. 2x STM1E (W/P) (S42024-L5460-A1)

    8. 8x FE/L2 (4x VC4) (S42024-L5495-A1)5. XCT [15/5G] w.STM-16/4(S42024-L5470-A1)6. 2x STM-1 (S42024-L5484-A1/A2)

    2 R4.1.1->R4.2.27. 2x STM1E (W/P) (S42024-L5460-A1)8. 8x FE/L2 (4x VC4) (S42024-L5495-A1)

    3. 1xGE/T (S42024-L5472-A1/A2)3 R4.2->R4.2.2

    4. 8xFE/T (S42024-L5469-A1/A2)

    N/A4 R4.2.1->R4.2.2

    Table 6.3-1 Reboot Information

    Nokia Siemens Networks Company Confidential 26 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    27/39

    The traffic on those cards will be interrupted for no more than 1 minute in worst scenario.The NE will be offline up to 10 minutes in worst scenario after NE rebooting.

    Cold reboot whole NE to complete the upgrade. The traffic interruption could be up to 5minutes in worst scenario. The NE will be offline up to 10 minutes in worst scenario afterNE reboot.

    Note:

    Either approach can be chosen to complete the reboot, but first approach isrecommended

    6.3.1 Warm rebooting NE approachIf the cold reboot approach is selected, please skip th is chapter and start from chapter6.3.2

    6.3.1.1 Warm reboot NE (only fo r case 3 and case 4)

    Click on Configuration

    NE

    Warm Reboot, you will get following window.Figure 6.3-1 Prompt window of warm reboot)(

    Figure 6.3-1 Prompt window of warm reboot

    Then click Yes to warm reboot NE. After successfully warm reboot NE, TNMS-CT willdisconnect NE automatically. During the warm reboot, the connectivity between NE and TNMS-CT is interrupted. Operator should re-open the Element manager windows manually aftersystem comes up. It is very important that you should close the current Element Manger afterNE disconnected automatically during warm reboot. Please wait 5 minutes before restartElement Manager so that NE can boot up completely. Restart the Element Manager in order toaccess the NE upgraded with corresponding version of Element Manager.

    6.3.1.2 Cold reboot cards (only for case 1, case 2 and case3, refer to Table 6.3-1 Reboot Information)

    Cold reboot 8xFE/T

    Right click on the 8FE/T card and then click Cold Reboot Card, the following window willpop up:

    Then click Yes to cold reboot card, after that all traffic on the card will be interrupted

    Nokia Siemens Networks Company Confidential 27 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    28/39

    Cold reboot the 1xGE/T

    Right click on the 1GE/T card and then click Cold Reboot Card, the following window will

    pop up:

    Then click Yes to cold reboot card, after that all traffic on the card will be interrupted.

    Cold reboot 2x STM-1

    Right click on the 2 x STM-1 card and then click Cold Reboot Card, the following windowwill pop up:

    Then click Yes to cold reboot card, after that all traffic on the card will be interrupted

    Cold reboot 2x STM-1E(W/P)Right click on the 2 x STM-1E(W/P) card and then click Cold Reboot Card, the followingwindow will pop up:

    Then click Yes to cold reboot card, after that all traffic on the card will be interrupted

    Cold reboot 8x FE/L2Right click on the 8x FE/L2 card and then click Cold Reboot Card, the following windowwill pop up:

    Then click Yes to cold reboot card, after that all traffic on the card will be interrupted

    Nokia Siemens Networks Company Confidential 28 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    29/39

    Cold reboot XCT [15/5G] w. STM-16/4 card with CC 1+1 protection

    Following behaviors and procedure should be followed to finish CC card (XCT [15/5G] w. STM-16/4) cold reboot.

    a. Check the active card. Click on ConfigurationCC 1+1 Protection, you will get followingwindow.

    Make sure CC cards are working with CC 1+1 Protection mode. And please record active cardand standby card. Here is an example for CC1 is active card and CC2 is standby CC card.

    b. Right click on the standby card and then click Cold Reboot Card, the following window willpop up:

    Then click Yes to cold reboot card, after that traffic on the card will be interrupted. About 15seconds later, the traffic will be restored. After finishing cold reboot, the card status will be activefrom chassis view.

    c. After the standby card cold reboots successfully and normally works, doing CC 1+1 forceswitch to standby card. Click on Configuration CC 1+1 Protection.

    Nokia Siemens Networks Company Confidential 29 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    30/39

    Choose Force switch to CC2, and click on apply. Here standby CC is CC2

    Make sure active card and standby card are exchanged.

    d. Cold reboot standby CC card to finish.

    Nokia Siemens Networks Company Confidential 30 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    31/39

    6.3.1.3 NE Version verification

    Click on ConfigurationNE software Management, you will get following window. Makesure that Active Software Version is Rel.4.2.2 Load 5.01.Figure 6.2-2 NE Software version verification)(

    Figure 6.3-2 NE Software version verification

    6.3.2 Cold rebooting NE approach

    If the warm reboot approach i s selected, please skip thi s chapter and start f rom chapter6.3.1

    6.3.2.1 Cold reboot NE

    Click on Configuration NE Cold Reboot NE, you will get following window.Figure 6.2-3 Prompt window of cold Reboot)(

    Nokia Siemens Networks Company Confidential 31 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    32/39

    Figure 6.3-3 Prompt window of cold Reboot

    Then click Yes to cold reboot NE. After successfully cold reboot NE, TNMS-CT will disconnectNE automatically. During the cold reboot, the connectivity between NE and TNMS-CT isinterrupted, and the traffic will be interrupted also. It is very important that you should close thecurrent Element Manger after NE disconnected automatically during cold reboot. Please wait 5minutes before restart Element Manger so that NE can boot up completely. Then restart theElement Manger in order to access the NE upgraded with corresponding version of ElementManger

    6.3.2.2 NE version verification

    Click on ConfigurationNEsoftware Management, you will get following window. Makesure that Active Software Version is Rel.4.2.2 Load 5.01.(Figure 6.2-4 NE Software version verification)

    Figure 6.3-4 NE Software version verification

    Nokia Siemens Networks Company Confidential 32 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    33/39

    7 CHECKING OF THE PACKAGE CONSISTENCY

    7.1 Alarm verification

    Click on Fault Active Alarms, you will get following window, make sure there is no activealarm in this table. Otherwise, please refer to SURPASS hiT7025 Troubleshooting Manual andclear all active alarms.Figure 7.1-1 Alarm verification)(

    Figure 7.1-1 Alarm verification

    7.2 NE Version verification

    Click on ConfigurationNEsoftware Management, you will get following window. Makesure that Active Software Version is Rel.4.2.2 Load 5.01.(Figure 7.2-1 NE Software version verification)

    Nokia Siemens Networks Company Confidential 33 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    34/39

    Figure 7.2-1 NE Software version verification

    8 FALLBACK

    If the traffic is abnormal after upgrade (For example: function problem, traffic dont return, orother unpredictable problem), please fallback the foregone release. During the fallback, all trafficwill be interrupted.

    8.1 Switch to foregone release

    Click on Configuration NEsoftware Management, you will get following window. Makesure that the Backup Software Version is Rel. 4.1 Build 4.60/ Rel. 4.1.1 Build 5.02/ Rel. 4.2 Build3.20/Rel. 4.2.1 Build 4.07.(Figure 8.1-1 NE backup software check)

    Nokia Siemens Networks Company Confidential 34 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    35/39

    Figure 8.1-1 NE backup software check

    Click Switch and the following window will pop up:(Figure 8.1-2 NE Software switching confirm)

    Figure 8.1-2 NE Software switching confirm

    Click Yes, the value of Status of Last Command will change to Need reboot to accomplishload switch!, if switching is successful, TNMS-CT prompts as following:(Figure 8.1-3 Prompt window of switching)

    Figure 8.1-3 Prompt window of switching

    Nokia Siemens Networks Company Confidential 35 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    36/39

    8.2 Clear MIB

    Click ConfigurationNE MIB Management To Local Folder, you will get followingwindow:(Figure 8.2-1 NE MIB upload)

    Figure 8.2-1 NE MIB upload

    The Clear MIB button is unavailable before upload MIB. So do it following Chapter 4.1 Then Click the Clear MIB button to clear the MIB.

    Cold reboot NEClick on Configuration NECold Reboot NE, you will get following window:Figure 8.2-2 Prompt window of cold Reboot)(

    Figure 8.2-2 Prompt window of cold Reboot

    Then click Yes to Cold reboot NE, after that the connection between NE and TNMS-CT will beinterrupted. About 5 minutes later, the traffic will restore.

    Nokia Siemens Networks Company Confidential 36 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    37/39

    8.3 Download MIB

    Click on Configuration NE MIB Management To Local Folder, you will get followingwindow. (Figure 8.3-1 NE MIB download)

    Figure 8.3-1 NE MIB download

    Then, click Download To NE to download hiT7025 MIB to the NE which you upload before toyour local PC in Chapter 4.1. Message will be prompted as the upper figure. Then clickYes .Once the downloading is finished, a message note will be prompted as follows.(Figure 8.3-2 NE MIB download successful)

    Figure 8.3-2 NE MIB download successful

    8.4 Switch MIB

    Click ok button. Then click Switch NE MIB button to switch the MIB.

    (Figure 8.4-1 NE MIB switch)

    Nokia Siemens Networks Company Confidential 37 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    38/39

    Figure 8.4-1 NE MIB switch

    Cold root NE

    Click on Configuration NE Cold Reboot NE, you will get following window:(Figure 8.4-2 Prompt window of cold Reboot)

    Figure 8.4-2 Prompt window of cold Reboot

    Then click Yes to Cold reboot NE, after that the connection between NE and TNMS-CT will beinterrupted. About 5 minutes later, the traffic will restore.

    Nokia Siemens Networks Company Confidential 38 (38}

  • 8/9/2019 Upgrade 7025 for R4.2.2

    39/39

    DisclaimerThe information in this document is subject to change without notice and describes only the

    product defined in the introduction of this documentation. This documentation is intended for theuse of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted inany form or means without the prior written permission of Nokia Siemens Networks. Thedocumentation has been prepared to be used by professional and properly trained personnel,and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomescustomer comments as part of the process of continuous development and improvement of thedocumentation.

    The information or statements given in this documentation concerning the suitability, capacity, orperformance of the mentioned hardware or software products are given as is and all liabilityarising in connection with such hardware or software products shall be defined conclusively andfinally in a separate agreement between Nokia Siemens Networks and the customer. However,Nokia Siemens Networks has made all reasonable efforts to ensure that the instructionscontained in the document are adequate and free of material errors and omissions. Nokia

    Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues whichmay not be covered by the document.

    Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NOEVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THISDOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL,DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUTNOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESSOPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THEINFORMATION IN IT.

    This documentation and the product it describes are considered protected by copyrights andother intellectual property rights according to the applicable laws.

    The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademarkof Nokia Corporation. Siemens is a registered trademark of Siemens AG.

    Other product names mentioned in this document may be trademarks of their respective owners,and they are mentioned for identification purposes only.

    Copyright Nokia Siemens Networks 2010. All rights reserved.