UPDATE THE NODEBWITH M2000
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Before starting work on site, you need to enter the following command on the side of BSC
enter SET BTSAUTODLDACTINFO in the Command Input box, and then click Assist.
Set the parameters displayed below the Command Input box as follows:
Index Type: BYNAME(By Name) or BYID(By Index)
Auto Download Active Function Switch: OFF(OFF).
Then, click Exec.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 3
Connect your laptop to the Ethernet
port of GTMU
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Setting the IP Address of the Site Maintenance Terminal PC
Procedure
To set the IP address of the PC, perform the following steps:
Choose Start> Setting > Control Panel.
Double-click Network Connections in the displayed Control Panel window. Right-click Local Area Connection in the displayed dialog box.
Choose Properties from the shortcut menu. The Local Area Connection Properties dialog box is displayed.
Select Internet Protocol (TCP/IP), and click Properties. The Internet Protocol (TCP/IP) Properties dialog box is displayed.
Select Use the following IP address.
Enter the correct IP address, subnet mask. (192.168.0.71 or other in the same segment)
Ensure that the IP address of the SMT PC is in the same network segment as the IP addresses (192.168.0.72/255.255.255.0) of the BTS so that a maintenance channel on the BTS side can be established.
Click OK to complete the settings.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
PING THE BTS
On the command prompt of your computer, run ping 192.168.0.72
If the information similar to that in the following example is returned, the SMT PC and the BBU can communicate normally.
Pinging 192.168.0.72 with 32 bytes of data: Pinging 192.168.0.72 with 32 bytes of data:
Reply from 192.168.0.72: bytes=32 time=1ms TTL=253 Reply from 192.168.0.72: bytes=32 time=1ms TTL=253 Reply from 192.168.0.72: bytes=32 time=1ms TTL=253 Reply from 192.168.0.72: bytes=32 time=1ms TTL=253
Ping statistics for 192.168.0.72: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 1ms, Maximum = 1ms, Average = 1ms
HUAWEI TECHNOLOGIES CO., LTD. Page 6All rights reserved
OPEN THE SMT
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
SETTING THE PARAMETERS TO CONNECT TO THE BTS
To connect to the BTS with the SMT:
1. Select Network Port
2. Input the ip 192.168.0.72
3. Click ok
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
GET THE MANAGEMENT RIGHTS
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
CLICK GET
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
CONFIRMATION OF THE MANAGEMENT RIGHTSACQUIRED
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Checking the Software Versions of the BTS Boards
Click Board in the navigation tree, and then double-click
Board Management in the Function pane on the right
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
In the displayed Board Management window, right-click the GTMU and
then choose Board Information from the shortcut menu.
The Board Information dialog box is displayed
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Loading the GTMU Software
On the SMT, click Site in the navigation tree, and then double-click Forced
Software Load in the Function pane on the right,
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
In the displayed Software Download dialog box, set the associated
parameters
File Name: Specify the path and name of the target software package required for the
upgrade.
Send Window Size: 200
Version: Type V100R009C00SP72 in the lower box.
File ID: Select GTMU_MAIN from the drop-down list.
Click Start.
When the progress bar displays "100%" in the lower corner and the status bar
displays "Loading Software Successfully", click Close
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Activating the GTMU Software
On the SMT, click Site in the navigation tree, and then double-click Software
Activation under Function.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
In the displayed dialog box, set the associated parameters as follows:
Version: Type V100R009C00SP72 in the lower box.
File ID: Select GTMU_MAIN from the drop-down list.
Board No.: You are not required to set this parameter.
Click OK..
When the status bar displays "Activation is confirmed and the Site will
be reset in a few minutes", click Close.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Checking the Software Versions of the BTS Boards Verify that the software is loaded correctly:
close and restart BTSM Click Board in the navigation tree, and then double-click Board Management in the
Function pane on the right
In the displayed Board Management window, right-click the GTMU and then choose Board Information from the shortcut menu.
The Board Information dialog box is displayed
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved