ururu sarara r32 rus

Click here to load reader

Post on 03-Dec-2014

255 views

Category:

Technology

3 download

Embed Size (px)

DESCRIPTION

Ururu Sarara R32 rus

TRANSCRIPT

  • 1. Ururu Sarara : FTXZ-N / RXZ-N

2. 2August 20, 2014 I ALL SEASONS CLIMATE COMFORT Ururu Sarara 1. 2. 3. 4. 5. 6. R32 1. 2. R32 3. 3. 3August 20, 2014 I ALL SEASONS CLIMATE COMFORT 1. Daikin SEER SCOP GWP ( ) 4. 4August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. (USP unique selling proposition) : , , , , , 3- on-line GWP ( ) 5. 5August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. SEER A+++ SCOP A+++ swing- c - Ururu Sarara 6. 6August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. : URURU SARARA (Flash streamer technology) 7. 7August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. : URURU 8. 8August 20, 2014 I ALL SEASONS CLIMATE COMFORT 28 2. : URURU , . . 30 , . 30 35 40 20% 22 50% 9. 9August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. : SARARA EKODORAI , , ( ) ( ) 10. 10August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. : SARARA 28 30 35 40 20% 22 50% 11. 11August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. : - (Flash streamer technology) , 12. 12August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. . 25% 13. 13August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. Coanda Ururu Sarara Coanda Coanda Ururu Sarara Ururu Sarara , , 14. 14August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. Comfort mode , .. , Ururu Sarara , 0,3/ . 39dBA ( ) 2 Ururu-Sarara 15. 15August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. 7 . : 35 : 26 Ururu Sarara 16. 16August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. Ururu Sarara 17. 17August 20, 2014 I ALL SEASONS CLIMATE COMFORT FAN 2. Ururu Sarara , . FAN 18. 18August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. 3- 2- Comfort ( ) 2 Comfort (= ) Spot (= ) Spot ( ) , 19. 19August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. , 2- , 20 - 1 ( 3 ) - , 20 min. + 2 - 2 1 ( 3 ) - 20. 20August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. - Quick heat timer , , , 15 , , . 22.00 07.00Program Quick Heat Timer for 7AM next morning , 7 ON OFF , 21. 21August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. , , AFR 22. 22August 20, 2014 I ALL SEASONS CLIMATE COMFORT 6 2. 23. 23August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. 2 : , on-line KKRP01A 24. 24August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. ( ) GWP 0 2.000 4.000 6.000 8.000 10.000 12.000 14.000 RXR50E RXS50K RXZ50N kg CO2 direct effect indirect effect 12 5% , 25% - LOT 10, GWP , 4th IPCCC TEWI 33% , 25. 25August 20, 2014 I ALL SEASONS CLIMATE COMFORT 3. FTXZ 25/35/50 N RXZ 25/35/50 N 295 798 370 15,5 693 795 300 50 26. 26August 20, 2014 I ALL SEASONS CLIMATE COMFORT 3. R410A RXR28E FTXR28E RXR42E FTXR42E RXR50E FTXR50E R32 RXZ25N FTXZ25N RXZ35N FTXZ35N RXZ50N FTXZ50N 27. 27August 20, 2014 I ALL SEASONS CLIMATE COMFORT 4. Preliminary specifications Operation limit Cooling DB -10~43 Heating DB -20~24 Humidifying DB -10~24 FTXZ25N FTXZ35N FTXZ50N RXZ25N RXZ35N RXZ50N kW 0.6 0.6 0.6 kW 2.5 3.5 5.0 kW 3.9 5.3 5.8 kW 0.6 0.6 0.6 kW 3.6 5.0 6.3 kW 7.5 9.0 9.4 A+++ A+++ A+++ kW 2.50 3.50 5.00 9.54 9.00 8.60 kWh 92 136 203 A+++ A+++ A+++ kW 3.50 4.50 5.60 5.90 5.73 5.50 kWh 831 1,099 1,425 6.10 5.30 4.55 5.80 5.00 4.47 dBA 38 42 47 dBA 33 35 38 dBA 26 27 30 dBA 19 19 23 dBA 54 57 60 dBA 59 61 63 type R32 R32 R32 charge 1.34 1.34 1.34 GWP (1) 550 550 550 OU - IU Max. m 10 10 10 System Chargeless m 10 10 10 height IU - OU Max. m 8 8 8 (1) According to IPCC Third Assessment Report refrigerant Piping length sound power indoor unit outdoor unit Sound pressure level indoor Cooling High Nom. Low Silent operation Annual energy consumption Nominal efficiency EER COP Seasonal efficiency Cooling Energy label Pdesign SEER Annual energy consumption Heating (Average climate) Energy label Pdesign SCOP Cooling capacity Min. Nom. Max. Heating capacity Min. Nom. Max. 28. 28August 20, 2014 I ALL SEASONS CLIMATE COMFORT 5. Centralised control board Up to 5 rooms KRC72 (2) KRP413A1S (1) Anti-theft protection for remote control KKF936A4 Interface adaptor for DIII-net KRP928A2S Central remote control DCS302C51 Unified on/off control DCS301B51 DST301B51 KKRP01A KKRPM01A KKRPW01A KBRC01A KBRCS01A KLIC-DD Humidifying hose extension set 2m KPMH974A402 Hose for humidification 10m KPMH974A42 Humidifying hose extension joint (10 pcs.) KPMJ942A4 NEW Humidifying hose L joint (10 pcs.) KPMJ983A4L Humidifying hose L cuff (10 pcs.) KPMH950A4L Wiring adapter normal open contact / normal open pulse contact Schedule timer KNX gateway Simple wall controller (4) Touch LCD wall controller (4) Wifi power cable for online controller External mounting kit for online controller Online controller 29. 29August 20, 2014 I ALL SEASONS CLIMATE COMFORT 6. FTXZ-N FTXR-E RXZ-N - RXR-E - ! 30. 30August 20, 2014 I ALL SEASONS CLIMATE COMFORT R-32 1. 2. R-32 3. 31. 31August 20, 2014 I ALL SEASONS CLIMATE COMFORT 1. ? , Daikin , . R410A GWP ( ) (UNFCCC) . 10 . , , , , . 32. 32August 20, 2014 I ALL SEASONS CLIMATE COMFORT 1. CFC HCFC GWP ? 33. 33August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. R32 R32 R410A R22 HFC HFC HCFC ( % ) R32/R125 (50% 50%) ODP 0 0 0.055 GWP*1 675 2100 1810 () () (suniso) (A2L) (A1) (A1) *2 1.6 1.6 1 *1: IPCC 4th Assessment *2: , R22, 1 R32 R410A GWP CO2 ( ) ( ) 34. 34August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. R32 > R32 , ? ASHRAE A: B: Class 3: A3 (: ) B3 Class 2: A2 B2 A2L (: R32) B2L (: ) Class 1: A1 ( R410A/R22) B1 35. 35August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. R32 > R32 , ? , .. , R32 extremely flammable- . 36. 36August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. R32 > R32 , ? 3- : , : 37. 37August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. R32 > : R32 : 6,7 / (=4 / 0,24 /) R32 : 6,7 / : 46,4 / 38. 38August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. R32 > : LFL UFL ( ) 100% 0% 0% 100% LFL UFL R32 14-31 - 1,8-8,4 5-15,8 R410A / 2,3->80 LFL-UFL 15-30 LFL R32 , , 14% R32 , R32 . , , (, ) LFL 2,3% 39. 39August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. R32 > : - Minimum ignition energy (MIE) , R32 , 15 100 , 0,017 (< 0,6 ), , R32 - Auto ignition temperature (AIT) - , ( ) AIT R32 648 C. 40. 40August 20, 2014 I ALL SEASONS CLIMATE COMFORT 2. R32 R-32 (LCCP) R410A R22 (LCCP - Lifecycle Climate Change Performance) (R32 R-410A) ( ) 41. 41August 20, 2014 I ALL SEASONS CLIMATE COMFORT 3. , R32 R410A , . DENV . 42. 42August 20, 2014 I ALL SEASONS CLIMATE COMFORT 3. 1. , LFL UFL. ( ) ( ) 2. -- , ( ) , ( ) 3. , ( ) 4. F-gas 43. 43August 20, 2014 I ALL SEASONS CLIMATE COMFORT 3. Ururu Sarara , . R32 R410A R-410A R-32 Gauge manifold Charging hose Scale Pipe bender Flare tool Torque wrench Pipe cutter Cylinder adaptor Vacuum pump Refrigerant recovery unit Refrigerant recovery cylinder Electronic gas leak detector Ventilation unit R32 , , R410A. (cylinder adapter). 44. 44August 20, 2014 I ALL SEASONS CLIMATE COMFORT 3. : : R32 45. 45August 20, 2014 I ALL SEASONS CLIMATE COMFORT 3. R32 : * HFC- ( R410A) -, . : 40 48 : ( , ) , 46. 46August 20, 2014 I ALL SEASONS CLIMATE COMFORT !

View more