use of 2 piece guide post for single implant case with linear & angular corrections 9.2016 jb
TRANSCRIPT
BLAND 3.28.15
in
Single Implant Casewith
Linear & Angular Corrections
Featuring
2-Piece Guide Post
Diagnostic & Surgical Guide
Software
Cone Beam X-rays
Bending Tool Corrections
A Geometric Approach to In-office Guided Implant Placement
DéPlaque
▪ fabricate diagnostic guide
▪ evaluate▪ correct ▪ re-fabricate surgical guide▪ verify▪ place
Guide Right™ Surgical Guide System
Method Used
Guide Right™ Surgical Guide System
fabricate ▪ evaluate ▪ correct ▪ verify ▪ place
Fabricate DIAGNOSTIC guide
Cone beam X-ray taken with DIAGNOSTIC guide in place
Evaluate linear & angular position of guide
Corrections: linear & angular
Verify
Fabricate SURGICAL guide
Surgical placement using corrected surgical guide
DéPlaque
▪ fabricate diagnostic guide
▪ evaluate▪ correct ▪ re-fabricate surgical guide▪ verify▪ place
Guide Right™ Surgical Guide System
3/32” drill used to drill prosthetically planned # 4 site.
A 3 mm straight guide post is placed in the prospective osteotomy site.
The cast is lubricated, Triad® gel applied to guide sleeve & adjacent
teeth capturing cleats to form the Diagnostic Guide
DéPlaque
▪ fabricate diagnostic guide
▪ evaluate ▪ correct ▪ re-fabricate surgical guide▪ verify▪ place
Guide Right™ Surgical Guide System
# 4Angle Correction: 10° to buccal
Implant: 11.5 x 4.5 mm
axial cross sectional
tangential volumetric
Invivo5
# 4
Angle Correction: 10.2° to buccal ▪ hard sharp setting
axial cross sectional
tangential volumetric
# 4
Linear Correction: 1 mm – 1.5 mm offset to the buccal
axial cross sectional
tangential volumetric
# 4
HOME POSITION: DIAGNOSTIC GUIDE
Setting: “hard sharpened” setting is used
axial cross sectional
tangential volumetric
DéPlaque
▪ fabricate
▪ evaluate
▪ correct ▪ re-fabricate [surgical guide]▪ verify▪ place
Guide Right™ Surgical Guide SystemGuide Right™ Surgical Guide System
2-Piece Straight Guide Post in Bending Tool Block
Guide Right™
Bending Tool
10°
10° correction made to the 1 mm offset guide post using the bending tool
Guide Right™
GUIDE POST BENDING TOOL
Steps to SINGLE BEND
Step 1 Place bending tool plate on a secure flat surface with the degree increments at the top & the stainless steel bar at the bottom.
Step 2 Locate the two 3/32” holes in the top of the stainless steel bar. The hole closest to the plate is used for all guide posts up to 3.0 mm offsets. The front hole is used for offsets 3.5 mm or larger. Place the bottom half of the guide post to be bent into the appropriate hole. Position the offset guide post in the hole determined by the planned direction of the correction. Tighten the set screw.
Step 3 Select the appropriate stylus to fit over the top half of the guide post.
Step 4 Fit the stylus over the guide post securely with the point directed at 0 ° & the bottom of the stylus in contact with the platform of 2-piece guide post or if no platform on post, in contact with block.
Step 5 Using the stylus as a lever, bend the guide post to the degree of angle ofcorrection. You may need to ease the point of the stylus beyond the point of the desired degree.
Step 6 Remove the stylus. Loosen screw to remove the guide post bent to the desired angle.
Steps to COMPOUND BEND
Guide Right™
GUIDE POST BENDING TOOL
Step 1 Position a straight or offset guide post in the bending plate, tightening the set screw against one of the 8 flat surfaces on the lower half of the guide post.
Step 2 The 1st bend can be made to the right or left direction.
Step 3 The set screw is loosened & the guide post is rotated 90° next flat surface.
Step 4 The 2nd bend in the 2nd plane is made after rotating the guide post up away from the surface of the bending plate to register the stylus point back at 0º.
Step 5 Slide the stylus support bar down under the stylus until it supports the stylus. Tighten the side screws before making the 2nd bend.
Step 6 The 2nd bend can be made in either direction according to the X-ray.
Step 7 Remove the stylus and place the guide post back in the cast with the appropriate side indicated by a mark with a felt tip pen facing the buccal
or lingual surface. Be sure the post is in the correct position.
Linear Corrections, using an offset guide post, must be determined & made before Angle Corrections.
Offset 2-Piece Guide Posts available in the 3 mm guide post: 0.5,1, 1.5, 2.0, 2.5 & 3.0 mm.
DéPlaque
▪ fabricate [diagnostic guide]
▪ evaluate
▪ correct
▪ re-fabricate [surgical guide]
▪ verify▪ place
Guide Right™ Surgical Guide SystemGuide Right™ Surgical Guide System
placed back in the cast with angle toward the buccal.
Straight Guide Post
bent 10°
3.8 mm guide sleeve
over 10° bent guide post
guide post with sleeve positioned in the cast hole
with cleat toward the lingual surface.
• Cast is lubricated & undercuts blocked out with yellow wax
• Triad® gel applied to guide sleeve capturing cleat & adjacent teeth
to form the Surgical Guide
Checking alignment of surgical guide
Guide Right™ Surgical Guide System
DéPlaque
▪ fabricate [diagnostic guide]
▪ evaluate
▪ correct
▪ re-fabricate [surgical guide]
▪ verify
▪ place
Final Implant Placement
Final abutment placement indicating use of straight abutment
Straight abutment
Occlusal View
Final Restoration
Final Restoration
Tangential View
Articulated View
Clinical Occlusal View
Final Restoration
Radiograph taken after the restoration is placed
Start With Precision. Place With Confidence.™
1.800.314.0065 • www.deplaque.com
DéPlaque
Guide Right™ Surgical Guide System
fabricate ▪ evaluate ▪ correct ▪ verify ▪ place
A Geometric Approach to Guided Surgery