use of rt for tml (cml), in lieu of ut study

14
Use of RT for TML (CML), in lieu of UT study Randall Bellard Bellard Consulting Services www.bellardcs.com (225) 993-2443

Upload: grace-horton

Post on 04-Jan-2016

51 views

Category:

Documents


3 download

DESCRIPTION

Use of RT for TML (CML), in lieu of UT study. Randall Bellard Bellard Consulting Services www.bellardcs.com (225) 993-2443. Purpose of trials. How does RT Profile thickness data compare with UT for both accuracy and repeatability? - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Use of RT for TML (CML),  in lieu of UT study

Use of RT for TML (CML), in lieu of UT study

Randall BellardBellard Consulting Serviceswww.bellardcs.com(225) 993-2443

Page 2: Use of RT for TML (CML),  in lieu of UT study

Purpose of trials

• How does RT Profile thickness data compare with UT for both accuracy and repeatability?

• How accurate and repeatable are RT measurements in locations that are not adjacent to the comparator due to uneven blow-up?

• Testing of different size test coupons to determine accuracy of computer radiography equipment for the determination of piping wall thickness

• Determine the variance between insulated and un-insulated piping• Testing of techniques utilized by the technicians for comparable results

2

Page 3: Use of RT for TML (CML),  in lieu of UT study

Testing parameters-1st trial• Worked with NDT Vendor to produce the images on a GE Rhythm CR 100• 1st trial utilized 2” and 6” coupons-piping and elbows-same technician with

supervised instruction• UT readings were taken at the (10) selected TML locations• Placed 1” comparator balls on the coupons for each RT exposure• Performed the trial with (4) different exposure setups (Slides 5, 6, & 7)• Performed trial with insulation and without• Measured at all locations with calibrations performed next to ball and at the

typical O.D. of elbow• Determined the extent of the accuracy of the Measuring Tool, as compared

to UT data

Page 4: Use of RT for TML (CML),  in lieu of UT study

Testing parameters-2nd trial• 2nd trial performed on in-service field circuit – (3/4”, 4”, and 6”)• Tested (3) operators-no formal instructions provided, other than circuit and

RT locations• Tested (2) additional technicians with technique specifics given (source

location, ball, and film placement, etc…)• Computed RT readings were taken with the Manual Measuring Tool and

with the Automated Wall Thickness Measurement Tool • Determined the variance from UT and RT readings acquired

4

Page 5: Use of RT for TML (CML),  in lieu of UT study

Setup details of 1st trial

5

Page 6: Use of RT for TML (CML),  in lieu of UT study

Setup details of 1st trial

6

Page 7: Use of RT for TML (CML),  in lieu of UT study

Setup details of 1st trial

7

Page 8: Use of RT for TML (CML),  in lieu of UT study

Trial 1 – 2” measurements

Setup 1 Setup 2 Setup 1 Setup 2 Setup 3 Setup 4 Setup 3 Setup 4

Source Position 1

Source Position 2

Source Position 1

Source Position 2

Source Position 1

Source Position 2

Source Position 1

Source Position 2

1 0.218 0.216 0.210 0.214 0.215 0.213 0.214 0.210 0.2142 0.218 0.212 0.206 0.212 0.208 0.211 0.208 0.215 0.2103 0.207 0.201 0.203 0.202 0.202 0.203 0.201 0.198 0.2004 0.219 0.215 0.213 0.213 0.214 0.219 0.220 0.217 0.2195 0.219 0.215 0.209 0.212 0.206 0.211 0.210 0.208 0.2096 0.219 0.215 0.209 0.212 0.206 0.211 0.210 0.208 0.2097 0.252 0.242 0.236 0.246 0.246 0.239 0.246 0.244 0.2458 0.270 0.252 0.260 0.258 0.262 0.262 0.262 0.262 0.2629 0.250 0.258 0.243 0.255 0.252 0.255 0.251 0.256 0.259

10 0.223 0.214 0.214 0.210 0.215 0.220 0.218 0.214 0.218

Calibraton Nearest Ball

Insulated

LocationUT

Thickness

Calibration Center OD Ball

Calibraton Nearest Ball

Uninsulated Calibration Center OD

Ball

8

Page 9: Use of RT for TML (CML),  in lieu of UT study

Trial 1 – 2” variances from UT

Setup 1 Setup 2 Setup 1 Setup 2 Setup 3 Setup 4 Setup 3 Setup 4

Source Position 1 Variance from UT

Source Position 2 Variance from UT

Source Position 1 Variance from UT

Source Position 2 Variance from UT

Source Position 1 Variance from UT

Source Position 2 Variance from UT

Source Position 1 Variance from UT

Source Position 2 Variance from UT

1 0.218 0.002 0.008 0.004 0.003 0.005 0.004 0.008 0.0042 0.218 0.006 0.012 0.006 0.010 0.007 0.010 0.003 0.0083 0.207 0.006 0.004 0.005 0.005 0.004 0.006 0.009 0.0074 0.219 0.004 0.006 0.006 0.005 0.000 -0.001 0.002 0.0005 0.219 0.004 0.010 0.007 0.013 0.008 0.009 0.011 0.0106 0.219 0.004 0.010 0.007 0.013 0.008 0.009 0.011 0.0107 0.252 0.010 0.016 0.006 0.006 0.013 0.006 0.008 0.0078 0.270 0.018 0.010 0.012 0.008 0.008 0.008 0.008 0.0089 0.250 -0.008 0.007 -0.005 -0.002 -0.005 -0.001 -0.006 -0.009

10 0.223 0.009 0.009 0.013 0.008 0.003 0.005 0.009 0.005

Calibration Center OD Ball

Uninsulated

LocationUT

Thickness

Insulated

Calibraton Nearest Ball

Calibration Center OD Ball

Calibraton Nearest Ball

9

Page 10: Use of RT for TML (CML),  in lieu of UT study

Trial 1 – 6” measurements

10

Page 11: Use of RT for TML (CML),  in lieu of UT study

Trial 1 – 6” variances from UT

11

Page 12: Use of RT for TML (CML),  in lieu of UT study

UT comparison

12

Page 13: Use of RT for TML (CML),  in lieu of UT study

Results of 2nd trial-3/4”, 4”, & 6”

13

Page 14: Use of RT for TML (CML),  in lieu of UT study

Summary of trials• The results from the 1st trial proved that the closer the Measuring Tool is to the

ball comparator, the more accurate the actual wall thickness reading with RT• In most instances in the 1st trial, the UT/RT readings were very similar with a

maximum isolated deviation of 0.027” which occurred on the 6” specimen at location 3

• In the 2nd trial, the results from the techs given a basic setup technique, the results had little variance from one tech to another, 0.006” in worst case

• If a consistent technique is used to collect data using profile radiography it can be used to determine corrosion rates with a high degree of confidence

14