Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI. A.Listopad 1 , J.Coenen 2 , V.Davydenko 1 , A.Ivanov 1 , V.Mishagin 1 , V.Savkin 1 , G.Shulzhenko 1 , B.Schweer 2 and R.Uhlemann 2 1 Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk, RUSSIA - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/1.jpg)
Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI
A.Listopad1, J.Coenen2, V.Davydenko1, A.Ivanov1, V.Mishagin1, V.Savkin1, G.Shulzhenko1, B.Schweer2 and R.Uhlemann2
1Budker Institute of Nuclear Physics SB RAS,630090 Novosibirsk, RUSSIA
2 Trilateral Euregio Cluster, Institut fuer Energie- und Klimaforschung,Forschungszentrum Juelich GmbH, Association EURATOM-FZJ, 52425 Juelich, Germany
![Page 2: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/2.jpg)
Madrid
Padova Lausanne
Juelich
![Page 3: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/3.jpg)
List of NBI parameters
TEXTOR DNBI
ALCATORDNBI
TAE HNBI MST HNBI
Beam energy, keV
20-50 20-55 20-40 25
Max. extracted current, A
3 6.5 40 50
Duration, s 8 2 1 0,02
Beam divergence, degrees
0,35 x 0,6 0,55 1 1,2
Ion species, % (by current)
85/10/5 90/5/5 70/10/20 80/10/10
Diagnostic served
CXRS MSE, CXRS
![Page 4: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/4.jpg)
NBI with focused beam (40 kV, 40 A, 1 s, and >10 kW/cm2)
![Page 5: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/5.jpg)
Atomic driver based on arc generator
Lanthanum hexaboribe thermocathode
Arc-discharge channel
Converter
H
Water cooling
0
![Page 6: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/6.jpg)
Multi-head source based on arc generators
Atomic driverEmitter region
Expander
![Page 7: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/7.jpg)
Arc generator as the source of dense particle flux
Arc plasma source
Magnetic coil transporting system
Sample surface
Density of plasma flow at the anode outlet is 10*(14)/cm2. With the magnetic coil system this can be transported and focused with similar density at the sample surface.
B ~ 1 kGs
![Page 8: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/8.jpg)
Outlines
• RUDI modernization overview
– New ion-optical system
– Optical diagnostic setup
– Metal ceramic arc element
• CXRS measurements
• Summary and outlook
![Page 9: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/9.jpg)
Outlines
• RUDI modernization overview
– New ion-optical system
– Optical diagnostic setup
– Metal ceramic arc element
• CXRS measurements
• Summary and outlook
![Page 10: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/10.jpg)
RuDI neutral beam injector
Nominal beam parameters:– Energy of particles (Hydrogen) 50 keV– Ion current 3 A– Beam current in 50keV neutrals 1.5 A– Beam pulse duration 6-8 sec (modulated)– Focal length 4 m– Diameter 1/e (at the focal plane) 50 mm x 80 mm– Angular divergence ±0.35° x ±0.6°
![Page 11: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/11.jpg)
Round and slit RUDI beamlet geometries
BEAM
U1=50 kVU2=43 kV
U3=-500 V
U4=0 V
![Page 12: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/12.jpg)
Slit RUDI grids photos
![Page 13: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/13.jpg)
Beam components scans across the slits at 45 kV
![Page 14: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/14.jpg)
RUDI beam divergence scan at 45 kV (6,6 kV 1st gap)
![Page 15: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/15.jpg)
Modernized RUDI arc-discharge plasma generatorEnhanced anode shape
O-rings sealed arc channel version
![Page 16: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/16.jpg)
CH1: Arc Current (100 A/check)CH2: Arc voltage (20 V/check)
CH1: HV (10 kV/check) CH2: Beam current (1 A/check)
RUDI 8 second shot oscillorgammes
![Page 17: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/17.jpg)
RUDI typical beam species composition
![Page 18: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/18.jpg)
Outlines
• RUDI modernization overview
– New ion-optical system
– Optical diagnostic setup
– Metal ceramic arc element
• CXRS measurements
• Summary and outlook
![Page 19: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/19.jpg)
Charge-eXchange Recombination Spectroscopy
Lower observation system
Upper observation system
H-beam
DED
Toroidal observation
system
![Page 20: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/20.jpg)
TEXTOR plasma density traces (ne (line average))
n*1013, cm-3
4
3
2
1
![Page 21: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/21.jpg)
Shots 115838/115843; Ti measurements (total averaging 5.5 s).
Flat top: 0.8 – 6.8 s, RUDI operation 1.3-7.5 s, Analyzed 1.3 – 6.8 s.
![Page 22: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/22.jpg)
Shots 115838/115843; vp measurements (total averaging 5.5 s).
Flat top: 0.8 – 6.8 s, RUDI operation 1.3-7.5 s, Analyzed 1.3 – 6.8 s.
![Page 23: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/23.jpg)
Averaging 1 s (115845) vs 5,5 s intervals (115838, 115843)
All the results of Ti measurements have very stable repetition (Even with 1 s time averaging)
![Page 24: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/24.jpg)
Shot 115845; Density Steps 1.2-3.1 s , 3.1-4.1 s , 4.1-5.5 s.
n*1013, cm-3
4
3
2
1
![Page 25: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/25.jpg)
1 s is enough for Ti and almost enough for rotation analysis
Ion Temperature measurements:
Analyzed intervals for 1.3-3.1 s, 3.1-4.1 s, 4.1-5.5 s.
Poloidal velocitymeasurements:
Ti[eV]
R[m]
v[km/s]
R[m]
![Page 26: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/26.jpg)
Summary
• Optical beam diagnostic complex was developed• New slit ion optics is introduced (June 2010)• Beam current achieved 2,8A (at 49 kV, due to HV PS power limit) • Beam diameter at 2m ~3cm along the slits• Beam species composition ~80% protons• More than 100% CXRS signal level rise• New arc-discharge element has provided 6-8 s beam duration
![Page 27: Use of the focusing multi-slit ion optical system at the diagnostic injector RUDI](https://reader035.vdocuments.net/reader035/viewer/2022070503/56815607550346895dc3cb17/html5/thumbnails/27.jpg)
Summary
• Optical beam diagnostic complex was developed• New slit ion optics is introduced (June 2010)• Beam current achieved 2,8A (at 49 kV, due to HV PS power limit) • Beam diameter at 2m ~3cm along the slits• Beam species composition ~80% protons• More than 100% CXRS signal level rise• New arc-discharge element has provided 6-8 s beam duration
Thank you very much!