MegaPAC™ Family Rev 1.6 Page 1 of 10 03/2016 User- and Field-Configurable Power Supplies MegaPAC™ Family AC-DC and DC-DC Switchers Features & Benefits AC inputs available: 85 – 264V AC , 208 / 240V AC 3-Phase Power factor corrected (some models) Up to 4kW DC inputs available: 100 – 380V DC User and field configurable Compact sizes as small as 3.4 x 6.0 x 9.5in [86.4 x 152.4 x 241.3mm] Fan cooled Efficiency >80% Up to 20 regulated outputs (up to 10 slots) from 1 to 95V DC and above Full power to 45°C on most products OVP, OTL, OCP on most outputs Autosense Power fail warning Sequencing and general shut down Agency approved cTÜVus, CE Marked Current Sharing Low leakage option available (some models) Product Description The MegaPAC family of products offers four different versions of user configurability to meet almost any set of input and output requirements. Leveraging Vicor modular DC-DC converters, MegaPAC family products combine feature-laden front ends with slide-in output assemblies called ConverterPACs. User configurability is at the heart of every MegaPAC. A wide variety of the same length ConverterPACs™ can be installed, exchanged or removed with the turn of just one screw. This means the MegaPAC can be reconfigured to meet evolving power requirements. Given its range of configurability, the MegaPAC is appropriate for virtually any application from prototype through production. PFC MegaPAC-EL/HPEL 15.6 x 6.0 x 3.4in [396.2 x 152.4 x 86.4mm] Up to 2400W at 230V AC 1 – 16 Outputs (8 Slots) PFC MegaPAC/HP 12.3 x 6.0 x 3.4in [312.4 x 152.4 x 86.4mm] Up to 2400W at 230V AC 1 – 16 Outputs (8 Slots)

Upload: others

Post on 25-Oct-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: User- and Field-Configurable Power Supplies

MegaPAC™ Family Rev 1.6Page 1 of 10 03/2016

User- and Field-Configurable Power Supplies

MegaPAC™ FamilyAC-DC and DC-DC Switchers

Features & Benefits

• AC inputs available: 85 – 264VAC, 208 / 240VAC 3-Phase

• Power factor corrected (some models)

• Up to 4kW

• DC inputs available: 100 – 380VDC

• User and field configurable

• Compact sizes as small as 3.4 x 6.0 x 9.5in [86.4 x 152.4 x 241.3mm]

• Fan cooled

• Efficiency >80%

• Up to 20 regulated outputs (up to 10 slots) from 1 to 95VDC and above

• Full power to 45°C on most products

• OVP, OTL, OCP on most outputs

• Autosense

• Power fail warning

• Sequencing and general shut down

• Agency approved cTÜVus, CE Marked

• Current Sharing

• Low leakage option available (some models)

Product Description

The MegaPAC family of products offers four different versions of user configurability to meet almost any set of input and output requirements. Leveraging Vicor modular DC-DC converters, MegaPAC family products combine feature-laden front ends with slide-in output assemblies called ConverterPACs.

User configurability is at the heart of every MegaPAC. A wide variety of the same length ConverterPACs™ can be installed, exchanged or removed with the turn of just one screw. This means the MegaPAC can be reconfigured to meet evolving power requirements. Given its range of configurability, the MegaPAC is appropriate for virtually any application from prototype through production.

PFC MegaPAC-EL/HPEL15.6 x 6.0 x 3.4in

[396.2 x 152.4 x 86.4mm]Up to 2400W at 230VAC

1 – 16 Outputs (8 Slots)

PFC MegaPAC/HP12.3 x 6.0 x 3.4in

[312.4 x 152.4 x 86.4mm]Up to 2400W at 230VAC

1 – 16 Outputs (8 Slots)

Page 2: User- and Field-Configurable Power Supplies

MegaPAC™ Family Rev 1.6Page 2 of 10 03/2016

MegaPAC™ Family

MegaPAC Family

MegaPAC Configuration

[a] Low noise ripple for EL power supplies is 10mVP-P or 0.15% whichever is greater.[b] ConverterPACs with Maxi module

Model Dimension Input Voltage Output PowerNumber of

OutputsConvertPACs™

Per Slot

Mini MegaPAC™9.5 x 6.0 x 3.4in

[241.3 x 152.4 x 86.4mm]

90 – 132 / 180 – 264VAC Strappable

260 – 380VDC

1,000W @ 115VAC or 230 Vac

1 – 10 (5 slots)

ModuPAC™, JrPAC™, DualPAC™, RamPAC™,

BatPAC™

PFC MegaPAC-EL/HPEL™ [a] 15.6 x 6.0” x 3.4in [396.2 x 152.4 x 86.4mm]

85 – 264VAC 100 – 380VDC

1,200W @ 115VAC 2,400W @ 230VAC

1 – 16 (8 slots)

QPAC™, DualQPAC™, JrQPAC™, FinQPAC™ [b]

(FinQPAC requires 2 slots)

PFC MegaPAC/HP™12.3 x 6.0 x 3.4in

[312.4 x 152.4 x 86.4mm]85 – 264VAC

100 – 380 Vdc2,400W @ 230VAC 1,200W @ 115VAC

1 – 16 (8 slots)

ModuPAC, JrPAC, DualPAC, RamPAC, BatPAC, FinPAC™ [a]

(FinPACs require 2 slots)

4kW MegaPAC™14.0 x 7.5 x 4.9in

[355.6 x 190.5 x 124.5mm]

208 or 240VAC Three Phase

260 – 352VDC

4,000W – 3 phase1 – 20

(10 slots)

ModuPAC, JrPAC, DualPAC, RamPAC,

BatPAC, UniPAC™ [b]

DC-DC Converter

At the heart of every MegaPAC are Vicor zero-current switching, DC-DC converters. The modularity of the design combined with the breadth of the product line means virtually any output voltage can be provided.

ConverterPAC

ConverterPACs are the slide-in output assemblies that allow each MegaPAC to be easily configured to user-specified output requirements. Using the Vicor DC-DC converter, up to 600W of output power can be provided per ConverterPAC. Larger power needs are easily handled by paralleling ConverterPACs.

MegaPAC

Each MegaPAC houses an array of user-selected ConverterPACs to provide a customized power supply. Using a different front end for each product line, almost any input power can be accommodated. The result is a customized power supply with off-the-shelf delivery.

Page 3: User- and Field-Configurable Power Supplies

MegaPAC™ Family Rev 1.6Page 3 of 10 03/2016

MegaPAC™ Family

Performance Specifications

Typical at 25ºC, nominal line and 75% load, unless otherwise specified

ParameterPFC MegaPAC™, PFC MegaPAC-HP™,

PFC MegaPAC-HPEL™, PFC MegaPAC-EL™Mini MegaPAC™ 4kW MegaPAC™

Input Charactersitics

Input 85 – 264VAC 115 – 230VAC, Strappable208 / 240VAC, 3-phase, 4 wire

180 – 264VAC 1-phase

Standard Line 47 – 500Hz

Vantage Line47 – 63Hz

100 – 380VDC 260 – 380VDC 260 – 352VDC

Line Regulation 0.2% max from 10% to full load

Inrush Current25APK at 115VAC

80APK at 115 and 230VAC 30APK at 230VAC25APK at 230VAC

Ride-Through Time >20ms at nominal line, full load

Power Fail >3ms warning

Conducted EMI (47 – 63Hz)

EN 55022 Level B (certain configurations)EN 55022 Level A EN 55022 Level A

FCC B

Power Factor0.99 (115VAC)

0.65 0.92 (3-phase operation)0.98 (230VAC)

Surge Immunity (Common Mode & Normal Mode)

EN 61000-4-5 Class 3, Performance Critera B

Output Charactersitics

Load Regulation0.2% max from 10% to full load

0.5% from no load to 10% load

Set-Point Accuracy

Standard Line:1.0% for standard voltages, 2.0% for special or adjustable voltages

Vantage Line: 2.0% for standard voltages, 5.0% for special or adjustable voltages

See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of normal output voltage.

Ripple and Noise (20MHz BWL)

Standard outputs: 2% or 100mVP-P max whichever is greater, 10% minimum load

VXI options: 50mVP-P max for outputs, ≤15VDC; 150mVP-P max. 15V < VOUT ≤ 24V; 1% VOUT > 24V

2nd Generation QPAC, FinPAC, FinQPAC and UniPAC performance dependent on the converter module used. (Output of module is unfiltered.)

QPAC, DualQPAC, JuniorQPAC, RamPAC: 10mVP-P max or 0.15%, whichever is greater.

Overcurrent Protection105 –130% > 5V outputs

30 – 125% ≤ 5V outputs

Overvoltage Protection ModuPACs and QPACs: 115 – 135%

Efficiency 80% typical 82% typical 82% typical

Output Power

1,600W at 40°C (230VAC) PFC MegaPAC; PFC MegaPAC-EL (Low Noise)

1,000W at 45°C (115 / 230VAC)

4,000W at 45°C (3-phase)

2,400W at 40°C (230VAC) PFC MegaPAC HP, PFC MegaPAC HPEL

1,500W at 45°C (1-phase)1,200W at 40°C (115VAC) PFC MegaPACs

Page 4: User- and Field-Configurable Power Supplies

MegaPAC™ Family Rev 1.6Page 4 of 10 03/2016

MegaPAC™ Family

Performance Specifications (Cont.)

Typical at 25ºC, nominal line and 75% load, unless otherwise specified

ParameterPFC MegaPAC™, PFC MegaPAC-HP™,

PFC MegaPAC-HPEL™, PFC MegaPAC-EL™Mini MegaPAC™ 4kW MegaPAC™

Environmental

Storage Temperature –40 to +85ºC

Operating Temperature [c]

Vantage Line Full Power 0 to +40ºC 0 to +45ºC 0 to +45ºC

Vantage Line Half Power 0 to +60ºC 0 to +65ºC 0 to +65ºC

Standard Line Full Power –20 to +40ºC –20 to +45ºC –20 to +45ºC

Standard Line Half Power –20 to +60ºC –20 to +65ºC –20 to +65ºC

Safety Agency ApprovalscTÜVus

CE Marked for Low Voltage Directive and RoHS Recast Directive, as applicable

Product Weight (Fully Configured)

9.75lbs [4.43kg] (PFC MegaPAC & HP)

6.25lbs [2.84kg] 22.0lbs [10kg]12.8lbs [5.8kg] (PFC MegaPAC EL)

13.0lbs [6.0kg] (PFC MegaPAC HPEL)

Limited Warranty 2 Years

[c] PFC MegaPACs: The maximum operating temperature is 40°C. If using a VI-200™ with output voltage <12V and >150W, the operating temperature decreases to 35°C. This also applies when using a FinPAC™ with output voltage <24V and >500W. Mini MegaPAC & 4kW MegaPACs: The operating temperature is 45°C using any combination of modules and output voltages as long as the front-end rating is not exceeded. Normal derating applies to half power if the ambient temperature is 20°C hotter.

Page 5: User- and Field-Configurable Power Supplies

MegaPAC™ Family Rev 1.6Page 5 of 10 03/2016

MegaPAC™ Family

ConverterPAC™ Overview

nn Output voltages from 2 – 95VDC

nn Output power up to 600W

nn DC OK

nn Adjustment ranges from 50% to 110% of nominal

nn Autosense / Remote Sense

nn Low noise option:10mVP-P or 0.15%, whichever is greater

nn 80 – 90% efficiency

nn Current source outputs available

MegaPAC Configuration for MegaPAC Family Product

Converters Module(s) Used Maximum Output Power

VE-200 and VE-J00 ConverterPACs

ModuPAC™(M) (RoHS – GM)

1 VE-200 DC-DC Converter Up to 200W per ConverterPAC

RamPAC™(R) (RoHS – GR)

1 VE-J00 DC-DC Converter 1 Ripple Attenuator Module (VI-RAM)

Up to 100W for applications requiring low ripple / noise

DualPAC™(D) (RoHS – GD)

2 VI-J00™ DC-DC Converters Dual Output; Up to 100W each output

JuniorPAC™ (J) (RoHS – GJ)

1 VI-J00 DC-DC Converter Up to 100W

BatPAC™ (B) (RoHS – GB)

1 VI-200™ BatModA 200W programmable current source that can be

configured as a battery charger

QPAC™ [d] Low Noise

(L) (RoHS – GL)

1 VI-200 DC-DC Converter with differential- and common-mode filters

Up to 200W for applications requiring as low as 10mVP-P output noise

JrQPAC™ [d] Low Noise

(LJ) (RoHS – GLJ)

1 VE-J00 DC-DC Converter with differential- and common-mode filters

Up to 100W

DualQPAC™ [d] Low Noise

(LD) (RoHS – GLD)

2 VI-J00 DC-DC Converters with differential- and common-mode filters

Dual Output; Up to 100W each output

Maxi ConverterPACs

UniPAC™ (XU) (RoHS – GXU)

1 Maxi DC-DC Converter Up to 500W; Applicable for 3-phase / 4kW product

FinPAC™ [e] (PZ) (RoHS – GPZ)

1 Maxi DC-DC Converter Up to 600W; Applicable for PFC MegaPAC High Power

FinQPAC™ [e] (PZL) (RoHS – GPL)

1 Maxi DC-DC Converter with discrete output filter

Up to 600W; Applicable for PFC MegaPAC-HPEL

[d] Only for the extended-length MegaPACs[e] FinPACs and FinQPACs require two (2) slots.

Page 6: User- and Field-Configurable Power Supplies

MegaPAC™ Family Rev 1.6Page 6 of 10 03/2016

MegaPAC™ Family

MegaPAC Mechanical Drawings

Note: Newer power supplies have redesigned output studs which are 1/8th inch longer. Design guides available online at vicorpower.com for more details.

14 AWG WIRE

M4 OR #8-32 THREAD MAXIMUMSCREW PENETRATION .150 (4.00 MM)

INPUTS DO NOT

WITHOUTEARTH

GROUND

L2

115/230 VAC

300VDC

L1

47 TO 500 HzOPERATE

CLAMPING SCREWS NUT ZINC PLATED STEELWITH OPTIONAL BUSS BARS

1/4 - 20 SERRATED FLANGED

CUSTOMER MOUNTING HOLES (16X)

FROM OUTSIDE SURFACE.

47 TO 500 Hz

300VD

C

115/230 VAC L2

INPUTS

L1

OPERATE

GROUNDEARTH

WITHOUT

DO NOT

7 SP. @ 0.7285 (18,5)5.10 (129,5)

FAN

(DIRECTION OF AIR FLOW OPTIONAL)

6.04 (153,42)

3.37 (85,60)

11.93 (302,90)

2.49 (63,17)6.75 (171,45)

2.92 (74,17)

0.21 (5,33)

0.25 (6,35)

5.100 (129,54)

0.47 (11,94)

12.24 (310,82)

0.64 (16,31)

0.41 (10,35)

2.77 (70,23)

1.40 (35,56)

0.470 (11,94)

0.729 (18,52)

2.75 (69,85) 6.75 (171,45)

1.458 (37,03)

NOTE: SET SCREW MAXIMUMTORQUE = 4.4 INCH POUNDS

TOR

QU

E = 4.4 IN

CH

PO

UN

DS

NO

TE: S

ET S

CR

EW

MA

XIM

UM

LABEL NO: 94-00046 REV B

LAB

EL N

O: 94-00046 R

EV

B

MP

6-78

600

1600

001

057

D

PFC

Meg

aPAC

Meg

aPAC

3.275 (83,19)

14 AWG WIRE

INPUTS DO NOT

WITHOUTEARTH

GROUND

L2

115/230 VAC

300VDC

L1

47 TO 500 HzOPERATE

CLAMPING SCREWS

47 TO 500 Hz

300VD

C

115/230 VAC L2

INPUTS

L1

OPERATE

GROUNDEARTH

WITHOUT

DO NOT

M4 OR #8-32 THREAD MAXIMUM

FROM OUTSIDE SURFACE.SCREW PENETRATION 0.150 (4,00)

CUSTOMER MOUNTING HOLES (4X)

1/4 - 20 SERRATED FLANGED

WITH OPTIONAL BUSS BARSNUT ZINC PLATED STEEL

CUSTOMER MOUNTING HOLES (4X)M4 OR #8-32 THREAD MAXIMUMSCREW PENETRATION 0.150 (4,00)FROM OUTSIDE SURFACE.

FAN

(DIRECTION OF AIR FLOW OPTIONAL)

6.04 (153,42)

3.37 (85,60)

5.100 (129,54)

0.470 (11,94)

0.210 (5,33)

2.920 (74,17)

15.185 (385,70)

10.010 (254,25) 2.487 (63,18)

15.090 (383,29)

0.250 (6,35)

2.77 (70,23)

1.40 (35,56)

0.470 (11,94)

0.729 (18,52)

= 5.10 (129,5)7 SP. @ 0.7285 (18,5)

0.41 (10,35)

0.64 (16,32)

3.275 (83,19)

NOTE: SET SCREW MAXIMUMTORQUE = 4.4 INCH POUNDS

TOR

QU

E = 4.4 IN

CH

PO

UN

DS

NO

TE: S

ET S

CR

EW

MA

XIM

UM

LABEL NO: 94-00046 REV B

LAB

EL N

O: 94-00046 R

EV

B

PFC

Meg

aPAC

-EL

PFC MegaPAC™ / PFC MegaPAC-High Power™

PFC MegaPAC-EL™ (Low Noise)

Page 7: User- and Field-Configurable Power Supplies

MegaPAC™ Family Rev 1.6Page 7 of 10 03/2016

MegaPAC™ Family

MegaPAC Mechanical Drawings

Note: Newer power supplies have redesigned output studs which are 1/8th inch longer. Design guides available online at vicorpower.com for more details.

9.40 (238,8)

1.80 (45,7)

FAN

3.38 (85,8)

0.50 (12,7)

1.19 (30,2)

0.220 (5,6) 9.10 (231,3)

2.920 (74,2)

4.800 (121,8)

6.04 (153,4)

3.52 (89,4)

1.06 (26,9)

J9-5

J9-10.45 (11,4)

5.10 (129,5)

0.60 (15,2)

8.78 (223,0)

2.91 (73,9)

1.93 (49,0)

1.40 (35,6)

2.74 (69,6)

0.62 (15,7)

4=SP. @ 0.7285 (18,5)

AIR FLOW

TIGHTEN INNER NUTSDO NOT LOOSEN OR

0.040 X 0.13 SLOT

STANDARD

TYP.

TYP.

TYP.

45 IN-LBS ±5

(DUAL MOD)J1B-PIN1

(DUAL MOD)J1A-PIN1

1

J2B-PIN1(SAME AS J2)

(SAME AS J2)J2A-PIN1

R4

R12

(SCALE: NONE)

INPUT LEGEND

OPTION IS SPECIFIED.WHEN ADJUSTABLE OUTPUTR4 "TRIMPOT" PRESENT

(MODUPAC MODEL NO.)AS SHOWN (TYP)APPROXIMATELYLABEL LOCATED

AS SHOWNAPPROXIMATELYLABEL LOCATED

MODUPAC REMOVAL

MODUPACS, 5 PLACESTO SECURE/REMOVE#4-40 CAPTIVE SCREWS

J3-PIN1

J2-PIN1

(EXAMPLE)AIR BLOCK

OPTION AVAILABLE)(NO "POWER GOOD"DUAL MODUPAC

-P1

+P1

+P5 -P5 TYP.SERRATED FLANGED NUTS1/4 - 20 ZINC PLATED STEEL,

MAXIMUM TORQUE 10 IN-LBSCLAMPING SCREWS FOR INPUT LEADS,

MAX SCREW PENETRATION - 0.15M4/#8-32 THDS 16 PLACES

THRU J9-5) FOR #10 AWG INPUT WIRES0.20 SQ. (5.2 MM) OPENINGS (J9-1

J10 (PIN 1)

Min

iM

egaP

ACL2S2 L1/N

HERE.

EARTH

JUMPER

230 VACAS IS-OR-

115 VACWITH S1-S2

DO NOTRUN W/O

GROUND

S1

1/4 - 20 ZINC PLATED STEEL,SERRATED FLANGED NUTS

-P8 TYP.

+P8

+P1 -P1

BUS BARS - FORPARALLEL OUTPUTS

BUS BAR - FORSERIES OUTPUTS

DUAL MODUPAC(NO "POWER GOOD"OPTION AVAILABLE)

AIR BLOCK(EXAMPLE)

J2-PIN1

J3-PIN1

#4-40 CAPTIVE SCREWSTO SECURE MODUPACS10 PLACES

MODUPAC REMOVAL

LABEL LOCATEDAPPROXIMATELYAS SHOWN

LABEL LOCATEDAPPROXIMATELYAS SHOWN (TYP)(MODUPAC MODEL NO.)

R4 "TRIMPOT" PRESENTWHEN ADJUSTABLE OUTPUTOPTION IS SPECIFIED

R12

R4

J2A-PIN1(SAME AS J2)

(SAME AS J2)J2B-PIN1

1

J1A-PIN1(DUAL MOD)

J1B-PIN1(DUAL MOD)

45 IN-LBS ±5

TYP.TYP.

TYP.

0.31 X 1.25 AMP

MATES WITH HSG AMP NO.747547-2 PLUS SLIDE

2

STANDARD AIR FLOW

(OUTER NUT ONLY)

FOR FLAT RIBBON CABLEAMP NO. 746862-2 PLUG

LATCH OR SIMILAR.

DO NOT LOOSEN ORTIGHTEN INNER NUTS

9=SP. @ .7285 (18,5)6.56 (166,6)

1.40 (35,6)

0.25 (6,35)

L3

1.15 (29,2)

0.54 (13,7)

L2L1

2.068 (52,5)

0.240 (6,1)(12X) 1/8 X 1/2 SLOTS

1.852 (47,0)

0.560 (14,2)

0.46 (11,7)

.15 MAX. PENETRATION(16X) M4/#8-32 TAPPED HOLE

0.40 (10,2)

1.852 (47,0)

1.20 (30,5)

7.50 (190,5)

4.00 (101,6)

2.25 (57,2) 6.75 (171,5)

6.75 (171,5)2.25 (57,2)

1.20 (30,5)

0.65 (16,5)

5.10 (129,5)

1.64 (41,8)

11.95 (303,5)

12.28 (311,9)

4.90 (124,5)

4kW

Meg

aPAC

Mini MegaPAC™

4kW MegaPAC™

Page 8: User- and Field-Configurable Power Supplies

MegaPAC™ Family Rev 1.6Page 8 of 10 03/2016

MegaPAC™ Family

Connection Diagrams – Input

Connection Diagrams – Output

PFC MegaPAC™ PFC MegaPAC-High Power™

PFC MegaPAC-EL™ PFC MegaPAC-HPEL™ Mini MegaPAC™

ModuPAC™ JuniorPAC™ RamPAC™ DualPAC™

BatPAC™ FinPAC™

4kW MegaPAC™

1 2 3 4 5 6

7 8 9 10 11 12

INPUT CONNECTIONSJ9

J9-3 L1/NJ9-2 L2

J10 InterfaceJ10-1 E/D-1J10-2 E/D-2J10-3 E/D-3J10-4 E/D-4J10-5 E/D-5J10-6 E/D-6J10-7 E/D-7J10-8 E/D-8J10-9 Vcc +5V, 0.3AJ10-10 Signal GroundJ10-11 AC Power OKJ10-12 General Shutdown

J9-1 Earth Ground

Housing-Molex P/N: 39-01-2120Terminal-Molex P/N: 39-00-0039Crimp Tool-Molex P/N: 11-01-0197

J10

J2-PIN1

J3-PIN1

0UTPUT ADJUST

+V0UT

–VOUT

(REMOTE SENSE)J2

21

3 –SENSE+SENSE

MATING HARDWARE

TRIM PIN ACCESS

3 POWER GOOD2

1 SIGNAL GROUNDPOWER GOOD INVERTED

MATING HARDWARE

4

J3 DC OK (POWER GOOD)

VCC IN

HOUSING- MOLEX P/N: 50-57-9403TERMINALS- MOLEX P/N: 16-02-0103CRIMP TOOL MOLEX P/N: 63811-8700

HOUSING- MOLEX P/N: 50-37-5043TERMINALS- MOLEX P/N: 08-70-1040CRIMP TOOL MOLEX P/N: 63811-5200

MODUPAC, JRPAC, RAMPAC

VOLTAGE LIMIT ADJUST

J2 (BATPAC REMOTE INTERFACE)

CURRENT MONITOR

CURRENT LIMIT ADJUST

– VOUT

VOLTAGE LIMIT ADJUST

1

– VOUT

32

4

J2-PIN1

CURRENT LIMIT ADJUST

CRIMP TOOL MOLEX P/N: 63811-5200TERMINALS- MOLEX P/N: 08-70-1040HOUSING- MOLEX P/N: 50-37-5043MATING HARDWARE

BATPAC

+ V0UT+ V0UT

J2-B-PIN1

OUTPUT ADJUST

J2-A-PIN1J2 (REMOTE SENSE) MATING HARDWARE

HOUSING- MOLEX P/N: 50-57-9403TERMINALS- MOLEX P/N: 16-02-0103CRIMP TOOL MOLEX P/N: 11-01-02083 –SENSE

+ SENSE1 TRIM PIN ACCESS2OUTPUT ADJUST

J1-B-PIN1

J1-A-PIN1

(OUTPUT CONNECTORS)

1 AND 4 +VOUT

3 3 +R/SENSE 6 –R/SENSE

12

J1

TERMINALS- MOLEX P/N: 39-00-0039HOUSING- MOLEX P/N: 39-01-2060

CRIMP TOOL MOLEX P/N: 11-01-0197

MATING HARDWARE

6

54

2 AND 5 –VOUT

DUALPAC

P2 REMOTE SENSE TRIM/SC & POWER GOOD

POWER GOOD INVERTED

TRIM5

32

4

1 SIGNAL GROUND

POWER GOODVCC IN

76

+SENSE–SENSE

TERMINALS- MOLEX P/N: 08-70-1040HOUSING- MOLEX P/N: 50-37-5073

CRIMP TOOL MOLEX P/N: 63811-5200

MATING HARDWAREP2-PIN1

–VOUT

OUTPUT ADJUST

FINPAC

+ VOUT

1 2 3 4 5 6

7 8 9 10 11 12

INPUT CONNECTIONSJ9

J9-5 120VAC

J9-4 120VAC

J10 InterfaceJ10-1 E/D-1J10-2 E/D-2J10-3 E/D-3J10-4 E/D-4J10-5 E/D-5J10-6 N/CJ10-7 N/CJ10-8 N/CJ10-9 VCC +5V, 0.3AJ10-10 Signal Ground J10-11 AC Power OK J10-12 General Shutdown

J9-3 AC NeutralJ9-2 AC HotJ9-1 Earth Ground

Molex header Mini-fit Jr. 12 POS #39-30-1120Customer I/O interface mating receptacle Molex #39-01-2120with terminal #39-00-0039 and 18-24 AWG str anded wire.Use Molex tool #11-01-0197

} Jumper for115V operation

J10

INPUT CONNECTIONSJ1

J1-1 Line 3J1-2 Line 2J1-3 Line 1J1-4 Earth Ground

Amp 25 pin connector #841-17-DBFR-DA25Pplug for flat ribbon cable. Mates withhousing ADAM TECH #DB25-SR-SLand contacts #DCS-01B plus slide latch #HDW-043-25.

J10 Interface1 Signal Ground 14 Phase Fail Warning2 Signal Ground 15 Signal Ground3 Overtemp. Warning 16 Vcc +5 volt, 300 mA4 Analog Temperature 17 Vcc +5 volt, 300 mA5 General Shutdown 18 AC Power OK 6 No Connection 19 AC Power Fail7 Enable/Disable #10 20 Enable/Disable #98 Enable/Disable #8 21 Enable/Disable #79 Enable/Disable #6 22 Enable/Disable #510 Enable/Disable #4 23 Enable/Disable #311 Enable/Disable #2 24 Enable/Disable #112 Signal Ground 25 Gate Out Slot #10 (isolated)13 Gate In Slot #1 (isolated)

2 3 4 5 6 71 8 9 10 11 12 13

14 15 16 17 18 19 20 21 22 23 24 25

Page 9: User- and Field-Configurable Power Supplies

MegaPAC™ Family Rev 1.6Page 9 of 10 03/2016

MegaPAC™ Family

Connection Diagrams – Output (Cont.)

ConverterPAC™ Options

[f] FinPACs and FinQPACs require two slots. [g] Module dependent, 3.3V, 10 – 15V “T” option only.[h] All QPACs and RamPACs have output ripple of 10mVP-P or 0.15% whichever is greater. [i] Per slot-based indicator.

QPAC™ JuniorQPAC™ DualQPAC™

FinQPAC™

QPAC (L), JrQPAC (LJ)

TERMINALS- MOLEX P/N: 08-70-1040HOUSING- MOLEX P/N: 50-37-5073

CRIMP TOOL MOLEX P/N: 63811-5200

MATING HARDWARE

+SENSE

POWER GOOD

SIGNAL GROUNDPOWER GOOD INVERTED

VCC IN

21

3

P2-PIN1

TRIM45

–SENSE76

OUTPUT ADJUST

P2 REMOTE SENSE TRIM/SC& POWER GOOD

–VOUT

+VOUT

P2 REMOTE SENSE TRIM/SC & POWER GOOD

POWER GOOD INVERTED

TRIM5

32

4

1 SIGNAL GROUND

POWER GOODVCC IN

76

+SENSE–SENSE

TERMINALS- MOLEX P/N: 08-70-1040HOUSING- MOLEX P/N: 50-37-5073

CRIMP TOOL MOLEX P/N: 63811-5200

MATING HARDWAREP2-PIN1

–VOUT

OUTPUT ADJUST

FINPAC

+ VOUT

J1-B-PIN1

(OUTPUT CONNECTORS)

1 AND 4 +VOUT

3 3 +R/SENSE 6 –R/SENSE

1

2

J1-A

TERMINALS- MOLEX P/N: 39-00-0039HOUSING- MOLEX P/N: 39-01-2060

CRIMP TOOL MOLEX P/N: 11-01-0197

MATING HARDWARE

6

54

2 AND 5 –VOUT

DUAL QPAC

POWER GOOD INVERTED

N/C

SIGNAL GROUND

POWER GOODVCC IN

TRIM TOP

J1-A-PIN1

3 +R/SENSE 6 –R/SENSE6

5

4

J1-B

2 AND 5 –VOUT3

2

(OUTPUT CONNECTORS)

1 AND 4 +VOUT1

TERMINALS- MOLEX P/N: 39-00-0039CRIMP TOOL MOLEX P/N: 11-01-0197

HOUSING- MOLEX P/N: 39-01-2060

MATING HARDWARE

TRIM BOT5

32

4

1

76

OptionModuPAC™

(M)BatPAC™

(B)DualPAC™

(D)JuniorPAC™

(J)RamPAC™

(R)DualQPAC™

(LD)QPAC™

(L)JuniorQPAC™

(LJ)UniPAC™

(XU)FinPAC™

(PZ) [f]FinQPAC™

(PLZ) [f]

D Power Good OPT NA NA OPT OPT [i] OPT [i] OPT OPT OPT OPT OPT

T Trim: +10%/–10%

OPT [g] NA OPT OPT [g] OPT [g] NA OPT [g] OPT OPT OPT OPT

F Trim: +10%/–50%

OPT [g] NA OPT OPT [g] OPT [g] NA OPT [g] OPT OPT OPT OPT

V1 VXI Low Noise(150mVP-P 15V < VOUT ≤ 24V)

OPT NA OPT OPT NA [h] NA [h] NA [h] NA [h] NA NA NA [h]

V2 VXI Low Noise(50mVP-P ≤ 15V)

OPT NA OPT OPT NA NA NA NA NA NA NA

V3 VXI Low Noise(1% VOUT > 24V)

OPT NA OPT OPT NA NA NA NA NA NA NA

Parallelable STD STD NA NA NA NA STD NA STD STD STD

Autosense STD NA STD STD NA STD STD STD STD STD STD

Page 10: User- and Field-Configurable Power Supplies

MegaPAC™ Family Rev 1.6Page 10 of 10 03/2016

MegaPAC™ Family

Contact Us: http://www.vicorpower.com/contact-us

Vicor Corporation25 Frontage Road

Andover, MA, USA 01810Tel: 800-735-6200Fax: 978-475-6715

www.vicorpower.com

emailCustomer Service: [email protected]

Technical Support: [email protected]

Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems.

Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.

Specifications are subject to change without notice.

Visit http://www.vicorpower.com/megapac for the latest product information.

Vicor’s Standard Terms and Conditions and Product WarrantyAll sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage (http://www.vicorpower.com/termsconditionswarranty) or upon request.

Life Support Policy

VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.

Intellectual Property Notice

Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.

©2018 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation.All other trademarks, product names, logos and brands are property of their respective owners.