TRANSCRIPT

RFID vertical body

DCR-ATV & DCR-APV

user manual

This manual applies to both lever and knob models (lock model with knob used for illustration & demonstration purposes)

Adva

nced S

ecurity

Shared & Assigned Use Functionality

77-DCRAD-MN

Table of Contents

Getting Started _________________________________________ 2 CamlockPartsLists____________________________________________ 3 RequiredTools________________________________________________ 3 CamlockDoorOpeningPlacement _______________________________ 4 StrikePlateInstallation _______________________________________ 5 CamlockDoorMountingTemplate_______________________________ 6

Installation Instructions ________________________________ 8 BeforeYouBegin:DoorPrepRequirements_______________________ 9 LockHanding__________________________________________________ 9 CamlockVerticalBodyParts____________________________________ 10 RequiredInstallationTools ____________________________________ 10 InstallationSteps_____________________________________________ 11-12

Programming Instructions ______________________________ 14 LockInterfaceOverview________________________________________ 15 KeyGuide_____________________________________________________ 15 InitializingLocks______________________________________________ 16 ExpressRegistration __________________________________________ 17 RegisterAdditionalManagerBypassKeys________________________ 18 ForLostorStolenKeys ________________________________________ 19

Shared Use Instructions _________________________________ 20 ToOperatewithanRFIDaccesscard _____________________________ 21 ToOperatewithanADAUserKey ________________________________ 22 ToOperatewithaManagerBypassKey ___________________________ 23 ToOperatewithaProgrammingKey______________________________ 24

Assigned Use Instructions _______________________________ 26 ToChangetheRFIDaccesscard__________________________________ 27 ToAssignanADAUserKey ______________________________________ 28 ToOperatewithanAssignedRFIDaccesscard_____________________ 29 ToOperatewithanADAUserKey ________________________________ 30 ToOperatewithaManagerBypassKey ___________________________ 31 ToOperatewithaProgrammingKey______________________________ 32

Troubleshooting ________________________________________ 34 CommonLockIndicators________________________________________ 35 BatteryReplacement___________________________________________ 36 CamlockOverallDimensions____________________________________ 37 CamlockOverallDimensions____________________________________ 38

i

Warranty

ii

LIMITED WARRANTYSecurity People, Inc., dba Digilock (the “Company”) warrants to the original purchaser the products manufactured by the Company (the “Product”) to be free of defects in material and workmanship, provided: (i) The Company has been notified of such defects within two years of purchase date and been given the opportunity of inspection by return of any alleged defective Product to the Company, or its authorized distributor, free and clear of all liens and encumbrances, transportation prepaid, accompanied by the statement of defects and proof of purchase; and (ii) the Product has not been modified, abused, misused, or improperly installed, maintained, and/or repaired during such period; and (iii) such defect has not been caused by corrosion, exposure to moisture, or ordinary wear and tear. Digilock lock products are not designed or intended for exterior use or where exposed to moisture. Any exterior use where exposed to moisture is not covered by any warranties and voids any warranties. Any resulting damage caused by direct exterior exposure or moisture is at the purchasers own risk.

This warranty does not cover any labor costs for installation, removal and/or re-installation of the product being serviced or replaced under warranty. This warranty is strictly limited to product repair or replacement. This warranty does not cover batteries, normal wear of parts and/or damage resulting from any of the following: improper installation, negligent use or misuse of the product, use of improper voltage or current, use contrary to operating instructions, and/or disassembly, repair or alteration by any person other than the Company service personnel.

The Company will not evaluate warranted product without first obtaining a Return Merchandise Authorization (RMA) number from the Company. Such returns must be prominently marked with the Return Merchandise Authorization number and shipped prepaid (return shipping is the responsibility of the end-user). Under no circumstance is the Company liable for incidental or consequential damages. The Company makes no other warranty, and all implied warranties including any warranty of merchantability or fitness for a particular purpose are limited to the duration of the expressed warranty period as set forth above.

LIMIT ON LIABILITYThe Company’s maximum liability for any damages resulting from or caused by the Product, whether in contract, tort, or otherwise is limited to the purchase price of the Product. In no event shall the company be liable for any incidental or consequential damages of any nature arising from the sale or use of this Product, whether in contract, tort, or otherwise by either use or purchase of the Product the user or purchaser agrees to this limit on the company’s liability.

Note: Should the Product be considered a consumer product as may be covered by the Magnusson Moss Federal Warranty Act, please be advised that: (1) some states do not allow limitations on incidental or consequential damages or how long an implied warranty lasts so that the above limitations may not fully apply; (2) this warranty gives specific legal rights, and a buyer may also have other rights which may vary from state to state. For warranty service and shipping instructions, contact the Company. The Company reserves the right to make changes in designs and specifications or to make additions or improvements on its products without notice and without incurring any obligation to incorporate them on products previously manufactured. The Company is not responsible for any modification, addition or alteration to our products by others. Purchaser agrees to indemnify and hold Company harmless from all claims causes of actions, lawsuits, administrative actions, and damages (except as covered by the express limited warranty as set forth above) including reasonable attorney fees and costs arising out of or pertaining to the Product.

1

Getting Started

2

Camlock Parts List

Camlock Door Opening Placement

Strike Plate Installation

Strike Plate Door Mounting Template

Camlock Parts ListNote: Confirm that all lock parts are present. If there are damaged or missing parts contact your Digilock Product Support Specialist.

1-Cover Plate 1-Velcro Strip 1-Rear Cover

3-Lock Washers2-Phillips Screws

(M5 x 14 mm)*for 3/4˝ Door

1-Black Flat Head Phillips Screws (M3 x 10 mm)

3-Flat Washers1-Phillips Screw

(M5 x 10 mm)

1-Cylinder Stop1-Cam

3

Required Tools

1/4˝ Flat Head Screwdriver

Phillips Screwdriver Head Size #1 & #2

For lock installationPower DrillDrill Bits: 1/16˝

For Strike Plate Only

Warning:Donotuseanelectricscrewgunduringinstallationofthelockunlessequippedwithatorqueadjuster,whichmustbesetonalowtorquesetting.Otherwise,damagemaybecausedtothelock.

* If door is greater than 3/4” in thickness the screws provided will vary in length.

1-Battery Pack 3-AA Alkaline Batteries

1-Velcro Strip1-Strike Plate with

3-Self-Tapping Screws

Optional

1-Front Unit

(Both body styles shown)

Knob

Leve

r

*

4

Required Items: Camlock Door Mounting Template: See page 6 (print and cut out template) Pencil: To mark door and template Adhesive Tape: To secure template to door (masking tape recommended)Required Tools: Router (wood doors) or Reciprocal Saw (metal doors): To create Camlock opening

Camlock Door Opening Placement

Place the template over the strike plate. Using the corresponding markers on the template, align the template to the center and edge of the strike plate as shown above.Note: Do not remove the template, it is required for “Step 2”.

Step 1

Center LineCenter ofStrike Plate

Edge ofStrike Plate

Mark The Door EdgeOn The Template

Door Edge

DrawnMarker

LockOpening

Strik

e Ed

ge M

arke

r

With the positioned template, close the door. Draw a line on the template to mark the door edge. Then using the template “Center Line” mark a reference line on the door edge.

Step 2

Center LineCenter ofStrike Plate

Edge ofStrike Plate

Mark The Door EdgeOn The Template

Door Edge

DrawnMarker

LockOpening

Strik

e Ed

ge M

arke

r

Place the template over the door face and align the template using the marks drawn as directed on “Step 2”.Note: Secure the template to the door face with tape for the next step.

Step 3

Center LineCenter ofStrike Plate

Edge ofStrike Plate

Mark The Door EdgeOn The Template

Door Edge

DrawnMarker

LockOpening

Strik

e Ed

ge M

arke

r

Draw necessary marks to router out lock opening.

Step 4

Center LineCenter ofStrike Plate

Edge ofStrike Plate

Mark The Door EdgeOn The Template

Door Edge

DrawnMarker

LockOpening

Strik

e Ed

ge M

arke

r

5

Strike Plate InstallationNote: Skip these steps if a Digilock compatible strike plate is already present.

Doo

r Fra

me

Position the Strike Plate on the door frame centering it adjacent to the center of the mounting holes.

1

Doo

r Fra

me

0.125 in

(3.18 mm)

Mark Here

Allow 1/8” or 0.125 in (3.18 mm) from door edge and mark pilot holes for the adjustment slots as shown above.

2

Doo

r Fra

me

Drill PilotHoles Here

Drill 0.25 in (6.35 mm) pilot holes using a 1/16 in drill bit.

3

Doo

r Fra

me

Position the Strike Plate and 2 self-tapping screws into the 2 outer adjustment slots.NOTE: Do not tighten the screws.

4

Doo

r Fra

me

0.125 in

(3.18 mm)

Adjust the Strike Plate to the proper position (as shown in Step 2). Then tighten the 2 screws in the adjustment slots.

5D

oor F

ram

e

Place and tighten the third screw into the center Strike Plate hole to lock the Strike Plate into position.

6

Required Hardware & Tools:• Digilock Strike Plate with 3-Self-Tapping Screws• Pencil: To mark screw holes• Phillips Screwdriver: #1 or Cordless drill (with torque adjustment) and a phillips driver recommended

6

DO

OR

ED

GE

MAR

KER

MO

RTIS

E O

PEN

ING

FO

R

CAM

LOC

K IN

STAL

LATI

ON

STRIKE PLATECENTER LINE

Distance of door edge to

mortis opening

NOTE: This circle is for reference only. Use only if this hole exists from previous lock.

R 0.112 in(2.8 mm)

5.808 in(147.5 mm)

0.900 in(22.9 mm)

1.450 in(36.8 mm)

1.166 in(29.6 mm)

NOTE: Templates may not print to scale. Double check all measurements before drilling door. If printing this page, turn off any auto scaling in printer setup and print at 100%.

Camlock Door Mounting Template

7

Installation Instructions

8

Before You Begin

Lock Handing

Camlock Vertical Body Parts

Required Installation Tools

Camlock Installation Steps

9

Before You Begin Door Prep Requirements

FIG. BFIG. A

Strike Plate

NOTE: See Door Preparation Instructions for more information on pages 4-6.

Before installing, your door must be prepped with a Strike Plate (Figure A) and must be mortised to receive recessed lock (Figure B).

Lock HandingCamlock is non-handed see page 12, Step 7 for handing installation.

Cam Position Down Cam Position Up

Left Handed

Cam Position Down Cam Position Up

Right Handed

A

1-Front Unit

D

1-Rear Cover

B

1-Cover Plate1-Velcro Strip

C

1-Battery Pack 3-AA Alkaline Batteries

1-Velcro Strip

10

Note: For demonstration purposes the knob Camlock will be shown.

Camlock Vertical Body Parts

E

2-Phillips Screws(M5 x 14 mm)*for 3/4˝ Door

H

1-Cylinder Stop

G

3-Flat Washers

I

1-Cam

F

3-Lock Washers

J

1-Phillips Screw (M5 x 10 mm)

K

1-Black Flat Head Phillips Screws (M3 x 10 mm)

Required Tools

Phillips Screwdriver Head Size #1 & #2

For lock installation

* If door is greater than 3/4” in thickness the screws provided will vary in length.

*

L

1 x 2 inch Velcro Strip

11

Starting from the front of the locker door place the front unit (A) in to mortised opening of the locker door as shown above.Note: The Knob/Lever should be in the vertical unlocked position as indicated above.

Step 1

Knob in Vertical Position

From the back of the locker door, take the battery connector and thread it through designated opening of the cover plate (B). Place the cover plate (B) against the rear face of the door.

Step 2

Place the lock washer (F) and then the flat washer (G) on each of the phillips screws (E) before securing the cover plate. Secure the cover plate to the door with two phillips screws (G). Carefully lay the battery cable flat against the cover plate (B) as shown above (fully ex-tended). Then attach the velcro strip (L) over the battery cable onto the cover plate as shown above.

WARNING: Do not overtighten screws.

Step 3

Once the cover plate is secure, snap the battery cable to the battery pack (C). Pull the adhesive protector fro the velcro strip (L) the position the battery back as shown above.Note: Before going on make sure that there are no obstructions beyond the cover plate.

Step 4

Snap the rear cover (D) to the cover plate (B) by hooking the top tabs of the rear cover to the top lip of the cover plate as indicated above. Push the bottom of the rear cover to snap it into place on the bottom of the cover plate.

Step 5

Cov

er P

late

Top Hook Tabs

Bottom Lock Tab

Place the lock into the unlocked vertical position (as shown in step 1). Place the cam assembly on to the square mount in the following order: cylinder stop (H), cam (I), flat washer (G), lock washer (F) then the phillips screw-M5 x 10 mm (J).Note: Orientate the cylinder stop and the cam for right or left hand door installation as shown above.

Step 7

12

Follow the Programming Instructions section of this manual on pages 15-19.

Step 9

Secure the rear cover (D) with black flat head phillips screw (K) WARNING: Do not overtighten screw.

Step 6

TO LOCK

Close Locker Door

Enter:

C

any four-digit code

Enter:

C

previous four-digit code Turn Lever To:

position

TO UN-LOCK

Open Locker Door Turn Lever To:position

TO LOCKClose Locker Door

Turn Lever To:positionTO UNLOCK

Open Locker Door

Turn Lever To:position

Present RFID Card:

Present RFID Card:

RightHandInstallation

LeftHandInstallation

Step 8

Test the operation several times (as indicated be-low) while the door is open. Close the door and test the unit again. Make sure there are no alignment issues between the cam and the door strike plate and/or frame. Adjust alignment if necessary.

Then turn knob clockwise or counterclockwise

Enter: `

13

Programming Instructions

14

Camlock Interface Overview

Key Guide

Initializing Locks

Express Registration

Register Additional Manager Bypass Keys

For Lost or Stolen Keys

15

• Registers Manager Bypass Key(s)• Provides external power• Each lock accepts only (1) Programming Key• Minimum of (1) required per location

Programming Key (Yellow)

Key Guide

• Provides management access• Provides external power• Each lock accepts up to (25) Manager Bypass Key(s)• Minimum of (1) required per location

Manager Bypass Key (Black)

• ADA Compliant User Key• For use with lever Camlock• Recommend 5%

ADA User Key (Blue)

RF IDCARD

• ADA Compliant RFID Access Card• 1 Per User

RFID access card

Lock Interface Overview

RFID Antenna

Unlock Position

Lock Position Lock/Unlock Knob

Key Insert LED Usage Indicator

Key Symbol Button

Key InsertionDigilock Logo must face up.

Initializing Lock(s)

16

These steps will initialize and register one or more Manager Bypass Keys to one lock.

While the LED light is solid, touch each of the Manager Bypass Key(s) (black) to the key slot one at a time.A two tone beep will be heard each time a new key is touched to the lock indicating acceptance.

2

Test the programming by touching each Manager Bypass Key(s) (black) to the key slot of lock. If programming is successful, the Manager Key will allow the knob to be turned into either the locked or unlocked position.

4

Touch the Programming Key (yellow) to the key slot for one full second.A two tone beep will be heard and the LED light will turn solid. The lock is now in programming mode.

1

When you have finished touching all of your Manager Bypass Keys (black), end programming mode by reinserting the Programming Key (yellow). A two tone beep will be heard and the LED light will turn off. This lock is initialized and programmed with the Manager Bypass Key(s).

3

Start at locker #1

Go to the lock that was programmed in Step 1 on page 16.

Press and Hold: ` for 20 seconds, after 10 seconds 2 beeps will be heard, continue holding for the full 20 seconds.The LED light will flash.

1

Express RegistrationThese steps help speed registration and initialization of multiple new locks.

17

Touch the Programming Key (yellow) to the key slot of all locks to be programmed. A two tone beep will be heard and the LED light will flash once to indicate successful programming of each lock. Note: Hold Programming Key (yellow) in key slot until LED light turns off. This may take up to 15 seconds depending on the number of registered Manager Bypass Key(s) (black).

..

.3

Touch the Programming Key (yellow) to the key slot. A two tone beep will be heard and the LED light will turn off.Warning: If LED light does not turn off or stays solid you did not wait for the full 20 seconds. Wait for the LED light to turn off and wait 20 seconds before retrying. The Programming Key (yellow) has copied the programming information from locker #1 and is now ready to program all other locks in the locker room.

2

Test the programming by touching the Manager Bypass Key(s) (black) to the key slot of the lock(s). If programming is successful, the Manager Bypass Key will allow the knob to be turned into either the locked or unlocked position.

4

Register Additional Manager Bypass KeysTo add additional Manager Bypass Key(s) to locks that have been previously programmed.

18

Touch the Programming Key (yellow) to the key slot of the lock for one full second. The LED light will turn solid.

2

Touch the Programming Key (yellow) to the key slot of the lock for one full second. A two tone beep will be heard and the LED light will turn off.

4

6 Repeat Steps 1-4 to all additional locks or use Express Registration Instructions on page 17 to speed registration of newly added keys.

5 This lock is now programmed with the additional Manager Bypass Key(s). Test the programming by touching the Manager Bypass Key(s) (black) to the key slot of the lock(s). If programming is successful, the Manager Bypass Key(s) will allow the knob to be turned into either the locked or unlocked position.

Touch each additional Manager Bypass Key (black) to the lock one at a time. A two tone beep will be heard each time a new key is touched to the lock indicating acceptance.

3

Press and Hold: ` for 10 seconds until 2 sets of beeps are heard.The LED light will flash.

1 Go to a lock that has been programmed with existing

Manager Bypass Keys.

19

Contact your Digilock Product Representative to order a Replacement Programming Key.

For a Lost Programming Key

For Lost or Stolen Keys

For a Lost Manager Bypass Key(s)

Note: All remaining Manager Bypass Key(s) must be re-registered. Please follow instructions “To Re-register Additional Manager Bypass Key(s)” on page 18.

The following steps will erase registration of all Manager Bypass Keys.

Collect all remaining Manager Bypass Key(s) or order additional keys from your Digilock product representative.

1

Touch the Programming Key (yellow) to the key slot for one full second. The LED light will turn solid.

3

Touch the Programming Key (yellow) to the key slot for one full second. A two tone beep will be heard and the LED light will turn off. Any previously registered Manager Bypass Keys will be erased on this lock.

4

Press and Hold: ` for 10 seconds until 2 sets of beeps are heard.The LED light will flash.

2 Go to a lock that has been programmed with existing

Manager Bypass Keys.

Shared Use Instructions

20

To Operate with an RFID access card

To Operate with an ADA User Key

To Operate with a Manager Bypass Key

To Operate with a Programming Key

21

To Operate with an RFID access card

1) Find an available lock.2) Press: `3) Present: any RFID access card

1

RF IDCARD

To Lock

Turn knob counterclockwise (to the left) towards locked symbol.Warning: Lock will remain in the unlocked position if the knob is not turned within 7 seconds.

2

To Unlock

1) At the same lock.2) Press: `3) Present: Registered RFID access card

1

RF IDCARD

Turn knob clockwise (to the right) towards unlocked symbol.Warning: Lock will remain in the locked position if the knob is not turned within 7 seconds.

2

22

To Operate with an ADA User Key

Turn lever counterclockwise (to the left) towards locked symbol.Warning: Lock will remain in the unlocked position if the lever is not turned within 7 seconds.

2

1) Find an available lock.2) Touch any ADA User Key (blue) to key slot.

1To Lock

Turn lever clockwise (to the right) towards unlocked symbol.Warning: Lock will remain in the locked position if the lever is not turned within 7 seconds.

2To Unlock

1) At same lock.2) Touch the same ADA User Key (blue) to key slot.

1

The ADA Key is to be used with Camlock Lever only. Camlock Levers were designed to be fully ADA compliant. The following instructions apply to the ADA compliant Camlock Lever.

Turn knob counterclockwise (to the left) towards locked symbol.Warning: Lock will remain in the unlocked position if the knob is not turned within 7 seconds.

2

Touch a registered Manager Bypass Key (black) to key slot.

1

23

To Operate with a Manager Bypass KeyTo Lock

Turn knob clockwise (to the right) towards unlocked symbol.Warning: Lock will remain in the locked position if the knob is not turned within 7 seconds.

2To Unlock

Touch a registered Manager Bypass Key (black) to key slot.

1

a) Press: ` The LED will begin to flash.b) Touch the Programming Key (yellow) to the key slot for one full second.

1

Touch the Programming Key (yellow) to key slot.

1

24

To Operate with a Programming KeyTo Lock

To Unlock

Turn knob counterclockwise (to the left) towards locked symbol.Warning: Lock will remain in the unlocked position if the knob is not turned within 7 seconds.

2

Turn knob clockwise (to the right) towards unlocked symbol.Warning: Lock will remain in the locked position if the knob is not turned within 7 seconds.

2

b

a

25

Assigned Use Instructions

26

To Change the RFID Access Card

Assign an ADA User Key

To Operate with an Assigned RFID Access Card

To Operate with an ADA User Key

To Operate with a Manager Bypass Key

To Operate with a Programming Key

27

To Change the RFID access card

Present: A new RFID access cardLock will emit two tone beep and the LED light will turn off.

3

RF IDCARD

Assigned Use locks have the default of ` once initialized.

Note: The lock will accept only one RFID access card or one ADA User Key (blue) at a time.

Touch the Manager Bypass Key (black) to the key slot of the lock for one full second. The LED light will turn solid.

2

Go to a lock that has been programmed with existing Manager Bypass Keys.

Press and Hold: ` for 10 secondsLED light will flash.

1

28

Assign an ADA User Key

Touch an ADA User Key (blue) to key slot.Lock will emit two tone beep and the LED light will turn off.

3

The ADA Key is to be used with Camlock Lever only. Camlock Levers were designed to be fully ADA compliant. The following instructions apply to the ADA compliant Camlock Lever.

Note: The lock will accept only one RFID access card or one ADA User Key (blue) at a time.

Touch the Manager Bypass Key (black) to the key slot of the lock for one full second. The LED light will turn solid.

2

Go to a lock that has been programmed with existing Manager Bypass Keys.

Press and Hold: ` for 10 secondsLED light will flash.

1

29

To Operate with an Assigned RFID Access Card

Turn knob all the way counterclockwise (to the left) towards locked symbol.

1To Lock

After turning counterclockwise fully, verify the locker is secure by pulling gently at the locker door.

2

1) Press: `2) Present: Registered RFID access card

1

RF IDCARD

To Unlock

1) Turn knob clockwise (to the right) towards unlocked symbol.Warning: Lock will remain in the locked position if the knob is not turned within 7 seconds.2) Open door.

2

1) Turn knob clockwise (to the right) towards unlocked symbol.Warning: Lock will remain in the locked position if the knob is not turned within 7 seconds.2) Open door.

2To Unlock

Touch the assigned ADA User Key (blue) to key slot.

1

30

To Operate with an ADA User Key

Turn knob all the way counterclockwise (to the left) towards locked symbol.

1To Lock

The ADA Key is to be used with Camlock Lever only. Camlock Levers were designed to be fully ADA compliant. The following instructions apply to the ADA compliant Camlock Lever.

After turning counterclockwise fully, verify the locker is secure by pulling gently at the locker door.

2

31

To Operate with a Manager Bypass Key

1) Turn knob clockwise (to the right) towards unlocked symbol.Warning: Lock will remain in the locked position if the knob is not turned within 7 seconds.2) Open door.

2To Unlock

Touch a registered Manager Bypass Key (black) to key slot.

1

Turn knob all the way counterclockwise (to the left) towards locked symbol.

1To Lock

After turning counterclockwise fully, verify the locker is secure by pulling gently at the locker door.

2

32

To Operate with a Programming Key

a) Press: ` The LED will begin to flash.b) Touch the Programming Key (yellow) to the key slot for one full second.

1To Unlock

1) Turn knob clockwise (to the right) towards unlocked symbol.Warning: Lock will remain in the locked position if the knob is not turned within 7 seconds.2) Open door.

2

Turn knob all the way counterclockwise (to the left) towards locked symbol.

1To Lock

After turning counterclockwise fully, verify the locker is secure by pulling gently at the locker door.

2

b

a

33

Troubleshooting

34

Common Lock Indicators

Battery Replacement

Camlock Overall Dimensions

Contact Information

35

If there is no audible feedback when = button is pressed:Dead Batteries: To determine if the batteries are expired you must use the Black Manager Bypass Key that has an external

power source to power the lock. Simply, touch a registered Manager Bypass Key to the key slot for 30 seconds, remove and immediately retouch the same Key to unlock the lock. Note that the Red Programming Key will also supply bypass power to the lock in case of battery failure. If the lock functions with this key, you know the batteries need to be replaced. If the lock still fails to function please see the section in this manual on replacing batteries.

Over-Tightened: To determine if the lock is over-tightened on the door, try loosening the mounting screws. Afterwards, press the = Button. If there is audible feedback, this is an indicator that the mounting screws are too tight. When installing Digilock we strongly recommend using a hand driven 3/8” deep socket or a #2 Phillips head screwdriver (depending on lock model). In the event that a cordless power drill is required please turn the torque adjustment to #4 setting or below. This will prevent the lock from being over tightened and prevent damage to the ten-pin connection. If the ten-pin connection is damaged and the lock fails to function on the door, please contact Digilock customer support for additional assistance.

If the lock does not unlock with an RFID access card or ADA User Key:

When trying to open a lock with an RFID access card or ADA User Key, the lock will emit audible signals that provide feedback as to what may be happening. For the next steps, refer to the Lock Indicator list.

The Registered Manager Bypass Key or the Programming Key will also operate the lock to provide access.

If you are unsuccessful, please contact Digilock Customer Support.

Lock Usage Indicators The Digilock locks are designed to emit audible and visual feedback during regular use as well as when the lock might be encountering difficulties. The following are the most common lock usage indicators and their meanings.

1 beep and 1 flash of the LED light during operation. The lock is indicating that an invalid RFID access card or invalid key is being presented to the locker.

a) If this occurs while entering an RFID access card it means that the lock does not recognize this RFID access card. A registered Manager Bypass Key will allow immediate access to the lock. If this is an assigned use lock, the Manager Bypass Key can then be used to change the RFID access card.

b) If this occurs while using either a User Key or a Manager Bypass Key, it means this key is not properly registered to the lock. See instructions on how to register the key to the lock.

2 sets of three beeps during operation. The lock is indicating that the batteries are low

a) Replace the batteries located in the rear unit using high alkaline batteries. Instructions are available below. Contact your Digilock Customer Support representative for a quote on replacement batteries.

b) If batteries fail while in the locked position, the Manager Bypass Key or the Programming Key will supply external power to the lock. Use one of these keys to unlock the lock and replace the batteries immediately.

Trouble Shooting

36

The batteries are located in the back cover of the lock (behind the door).Battery Replacement

a) Remove the cam latch assembly by unscrewing the center screw. b) Then unscrew the rear cover screw.

TO LOCK

Close Locker Door

Enter:

C

any four-digit code

Enter:

C

previous four-digit codeTurn Lever To:

position

TO UN-LOCK

Open Locker DoorTurn Lever To:position

1

TO LOCKClose Locker Door

Turn Lever To:positionTO UNLOCK

Open Locker Door

Turn Lever To:position

Present RFID Card:

Present RFID Card:

TO LOCKClose Locker Door

Enter:C

any four-digit code

Enter:C

previous four-digit code

Turn Lever To: position

TO UN-LOCK

Open Locker Door

Turn Lever To: position

Insert a flat head screwdriver into the slot located at the bottom of the rear cover slot. Gently push the screw driver towards the door to unhinge bottom of the rear cover from the cover plate.

2

Remove the battery pack from the cover plate. Then unsnap the battery pack from the battery cable. Replace the batteries with 3 AA high alkaline batteries for optimal performance.

4

a) Snap the rear cover back onto the cover plate.b) Reinstall the rear cover screw.c) Reattach the cam latch assembly.

TO LOCK

Close Locker Door

Enter:

C

any four-digit code

Enter:

C

previous four-digit codeTurn Lever To:

position

TO UN-LOCK

Open Locker DoorTurn Lever To:position

6

Pull the bottom of the rear cover towards you, then lift the rear cover up and away from the door.

3

Re-snap the battery cable to the battery pack. With the battery cable tucked behind the battery pack then re-velcro the battery pack to the cover plate with the batteries facing out.

5

a

b

a

b

c

1.66 in(42 mm)

6.02 in(153 mm)

1.00 in(25 mm)

0.82in(21 mm)

1.88in(48 mm)

1.37in(35 mm)

1.54 in(39 mm)

0.63 in(16 mm)

6.75 in(171 mm)

2.0 in(56 mm)

1.75 in(45 mm)

1.66 in(42 mm)

1.01 in(26 mm)

1.54 in(39 mm)

0.63 in(16 mm)

6.02 in(153 mm)

1.00 in(25 mm)

0.82in(21 mm)

1.88in(48 mm)

1.37in(35 mm)

6.75 in(171 mm)

2.0 in(56 mm)

Knob

Lever

37

Dimensions Camlock Vertical RFID Body

38

Contacting Support

For additional product information including instructional videos. Please visit us online at: www.digilock.com/us/service.html

Via email: [email protected]

Directly at: Digilock 9 Willowbrook Court Petaluma, CA 94954

Phone: (707) 766-6000 Toll-Free Phone: (800) 590-0984 (US only) Fax: (707) 766-6226 Toll-Free Fax: (800) 989-4221 (US only)

www.digilock.com

9 Willowbrook CourtPetaluma • Ca 94954 • USA

phone: 707. 766.6000fax: 707. 766.6226

security simplif ied™

Digilock Lockup Celáre Numeris

security peoplein

c

C