user manual - roe visual user manual.pdf · when the input voltage is 220v, one power cable can...
TRANSCRIPT
User ManualMC-F
User Manual P1
Control System
Contents
Safety Information
3
Speci�cation 6
Connection 8
Accessories
12
Assembly
Physical Connection
9
10
13
17Package
16Service and Maintenance
User Manual P2
WARNING !
Safety hazard.Risk of severe
injury or death.
Refer to manual beforeinstalling, powering
or servicing.
Hazardous voltage.Risk of lethal or
severe electric shock.
Hot surface.Do not touch.
Fire hazard. Emission hazardousto eyesight.
This product is for professional use only. It is not for household use.
This product presents risks of severe injury or death due to �re hazards, electric shock and falls.
Read this manual before installing, powering or servicing this product, follow the safety precautionslisted below and observe all warnings in this manual and printed on the product.
If you have questions about how to operate the tile safely, please contact your ROE supplier.
PROTECTION FROM ELECTRIC SHOCK
Connect the product to AC mains power within the range 100-240V nominal at 50 or 60 Hz only.
Disconnect the product from power when not in use.
Always ground (earth) the product electrically.
Before using the product, check that all power distribution equipment and cables are in perfectcondition and rated for the current requirements of all connected devices.
Do not use the product if the power cable or a power plug is in any way damaged, defective orshowing signs of overheating.
Do not attempt to open any cover.
Refer any service operation not described in this manual to a quali�ed technician.
01 Safety Information:
Read the safety precautions in this section beforeinstalling, powering, operating or servicing this product.
The following sysmbols are used to identify important safety information on the product and in this manual:
WARNING! WARNING! WARNING! WARNING! WARNING! WARNING!
User Manual P3
165+5
PROTECTION FROM FIRE
Do not stick �lters, masks or other materials directly onto LED modules.
Do not modify the product in any way not described in this manual.
Install only genuine ROE parts in or on the product unless an alternative is described in this manual.
Create an installation by installing tiles at the top and working downwards. Disassemble an installation by removing tiles at the bottom and working upwards.
Check that all external covers and rigging hardware are securely fastened.
Block access below the work area and work from a stable platform whenever installing, servicing or moving the product.
Do not operate the product full load if the ambient temperature of power units (Ta) exceeds 50°C (122° F)or less than -20°C(-4° F).
170+5
1480
2000
Pout/W
Vin/Vac
PROTECTION FROM INJURY
Important warnings
Maximum and minimum ambient temperature:The maximum ambient temperature for the LED wall is 50 °C; the minimum temperature is (-20°C.)
User Manual P4
High leakage current:The combination of power boxes in an installation results in increased levels of Leakage current. In order to avoid risk of electric shock due to high leakage current, proper grounding of the installation is required.
Data cables:
The data cables provided with this system have special properties for safety. They are not user serviceable. If the data cables are damaged, replace them only with new ones. Never try to repair a data cable. Per requirements of the National Electrical Code in the USA, the length of a data cable must not exceed 100 m (332 feet). Avoid exposure of data cables to accidental contact with lightning or power conductors.
®
MC-F LED tiles cannot be hot swapped:
Always disconnect the power cord from the control box before connecting or disconnecting the cable string or one of MC-F LED tiles.
Power system
Mains cords:
The power cords delivered with this system have special properties for safety. They are not user Serviceable.If the power cords are damaged, replace them only with new ones. Never try to repair a power cord.
This equipment MUST be earthed:
In order to protect against risk of electric shock, the installation should be properly grounded. Defeating the purpose of the grounding type plug will expose you to the risk of electric shock.
User Manual P5
MC-7F Dimensions:
MC-9F Dimensions:
MC-7F Speci�cation:
MC-9F Speci�cation:
Specification:02
LED Type
Transparency
Brightness(Nit or CD/m²)
3in1 SMD
7.5mm
7%
600.0×600.0×50.0
0.36m²
IP(Front/Reverse)
80×80
17778
140°
7.0kg/15.4lbs
30 tiles
1/5
1800Hz
180W
-20°C to 45°C
Scan
Processing 2560×1024
Color Depth
Working Temperature
ETL/TUV/CECerti�cates
Pixel Pitch
Tile Size(mm) W×H×D
Tile Area
Pixels/Tile
Pixels/m²
Viewing Horizontal/Vertical
Weight/Tile
Max.hanging
16bit
IP65
Refresh Rate
Max Power/Tile
Cree 3435,4200/NationStar 3535,4000
LED Type
Transparency
Brightness(Nit or CD/m²)
3in1 SMD
9.375mm
17%
600.0×600.0×50.0
0.36m²
IP(Front/Reverse)
64×64
11378
140°
6.3kg/13.9lbs
30 tiles
1/4
3500Hz
180W
-20°C to 45°C
Scan
Processing 2560×1024
Color Depth
Working Temperature
ETL/TUV/CECerti�cates
Pixel Pitch
Tile Size(mm) W×H×D
Tile Area
Pixels/Tile
Pixels/m²
Viewing Horizontal/Vertical
Weight/Tile
Max.hanging
16bit
IP65
Refresh Rate
Max Power/Tile
Cree 3435,4200/NationStar 3535,4000
MC LED tiles is lightweight and virtually transparent outdoor LED display. They o�er wide viewing angles with excellent image integrity and color uniformity, owning the common characteristics of lightweight and �rm structure. With the amazing �exibility and high density, both of them can be able to multi-angle folded,satisfy your solution for applications with long viewing distances.
User Manual P6
MC-18F Dimensions:
MC-12F Dimensions:MC-12F Speci�cation:
Note:
MC-18F Speci�cation:
Rear diagram
49.0
LED Type
Transparency
Brightness(Nit or CD/m²)
3in1 SMD
12.5mm
21%
600.0×600.0×50.0
0.36m²
IP(Front/Reverse)
48×48
6400
140°
5.8kg/12.8lbs
30 tiles
Static
4000Hz
180W
-20°C to 45°C
Scan
Processing 2560×1024
Color Depth
Working Temperature
ETL/TUV/CECerti�cates
Pixel Pitch
Tile Size(mm) W×H×D
Tile Area
Pixels/Tile
Pixels/m²
Viewing Horizontal/Vertical
Weight/Tile
Max.hanging
16bit
IP65
Refresh Rate
Max Power/Tile
Cree 3435,4200/NationStar 3535,3500
LED Type
Transparency
Brightness(Nit or CD/m²)
3in1 SMD
18.75mm
37%
600.0×600.0×50.0
0.36m²
IP(Front/Reverse)
32×32
2844
140°
5.4kg/11.9lbs
30 tiles
Static
4000Hz
180W
-20°C to 45°C
Scan
Processing 2560×1024
Color Depth
Working Temperature
ETL/TUV/CECerti�cates
Pixel Pitch
Tile Size(mm) W×H×D
Tile Area
Pixels/Tile
Pixels/m²
Viewing Horizontal/Vertical
Weight/Tile
Max.hanging
16bit
IP65
Refresh Rate
Max Power/Tile
Cree 3435,4000/NationStar 3535,3600
User Manual P7
A. Vertical connectorB. Carry HandleC. Arc connector-rotation anlesD. Button-Fix the arcE. Horizontal connectorF. Disassemble button
G. Breather ValveH. Indicator lightI. Female data socketJ. Female power socketK. Data cableL. Power cable
03 Connection:
Data
Power and Data connections of MC-F tiles
MC-F
PowerData Adaptor
User Manual P8
1. Neither Hanging bar nor Vertical Interconnect Bolt can load more than 30 tiles of MC-F.2. When the Input Voltage is 220V, one Power Cable can load 16 tiles of MC-F; and the Input Voltage is 110V, one Power Cable can load 8 tiles of MC-F.
Notes:
Evision
AC 220V
AC 220V
①
②③
④
⑥
⑤
Power Box
Power Box
DVIUSB
⑩
⑧
⑨ ⑨
Accessories 04
Max Current : 32A
Name : Power CablePart No. : 208001S(0443/0444)Dimesion : 5m /30m
Weight : 1.5kg/7.3kg
Max Current : 32A
Name : Power CablePart No. : 208001S0438Dimesion : 2m
Weight : 0.6kg
Max Current : 20A
Name : Power CablePart No. : 208001S0246Dimesion : 30000mm
Weight : 2.5kg
Max Current : 20A
Name : Power CablePart No. : 208001S0450Dimesion : 200mm
Weight : 0.2kg
Name : Data CablePart No. : 208004S0088Dimesion : 800mm
Weight : 0.1kg
Name : Data CablePart No. : 208004S0086Dimesion : 800mm
Weight : 0.1kg
Name
Part No.
Dimension
Weight
Material
Hanging bar
207002S0002
L600×W171×H53mm
3.4kg
Cold Rolled Steel
::
:
:
:
Name
Part No.
Dimension
Weight
Max Length
Data Cable
208004S0194
30m
1.4kg
100m
::
:
:
:
Name
Part No.
Dimension
Weight
Evision
201000S0009
L480×W240×H45mm
2.3kg
:
:
:
:
Name
Part No.
Dimension
Weight
Power Box
202000S0003
L420×W380×H130mm
12.6kg
:
:
:
:
Name
Part No.
Dimension
Max Capacity
Flightcase 12pcs/case
309003-00027
L1314×W744×H872mm
12 tiles of MC-F
::
:
:
⑧⑦
⑩
⑨
User Manual P9
156.88
600.00
171.
10Header Assembly:05
User Manual P10
Hanging System
Hanging bar Dimensions:
Step 1: Match the holes in straight line.Step 2: Turn the knob and fit securely.
Step 3: Push the bolt in.
Step 1: Match the holes in the angle.Step 2: Turn the knob and fit securely.
Figure 2: Arc installation
Note: Adjust the height of header with the pulley.
Figure 1: Straight installation
Figure 3: The function of ring
Note: The ring suggest to be used in big show, special stage design, high level background display...
Headers suggest be used in car show, TV show…some close view distance display. The ring is not included in standart accessary rist.
User Manual P11
1. Install all the tiles securely.2. Loosen six buttons and take down the tile. 3. Connect the cables above and below nearby.
Physical Connection:06
MC-F&Hybrid mixing using Hollow-design
Note:Hanging bar can reach the angle of 50° both front and back direction.Tiles can reach the angle of 40°.For perfect visual e�ect, seamless curveable is 15°(Both front/back direction).
Note: Depending on uni�ed frame structure,all of MC families and hybrid can be integrated together.
Curve Installation
Step1:
Step2:
Straight installation
User Manual P12
1. Loosen the knob and buttons on the hanging bar and tiles.2. Adjust the angle.3. Tighten the knob and bottom.
The control system of MC-F series consist of receiving card and sending card.Receiving card is integrated with LED tiles.
Control System:07
User Manual P13
Software:
Please read software manual �rstly, (download link as below): Http://www.roevisual.com/how-to-make-led-display.
Evision (201000S0007)
Working v oltage
Power
100-240V AC
<20W
Working temperature -20°C to 45°C
Input port DVI
Output ports number 4 ports
Communication port USB/RJ45
1920×1080 60HzMax.Resolution(Input)
Data transmission port Gigabit Ethernet
Material AL6061
Dimension W480×H45×D240mm
Weight 2.30kg
1. Power switch2. Number keys3. LCD screen4. Function keys5. Knob
0 1 2 3 4
5 6 7 8 9
Black
DVIHDMI
OK
Esc Fn
Menu
Front
Behind
INPUT 100-240V AC 50/60HZPORT 4PORT 3PORT 2PORT 1USB2USB1HDMIDVI
1
6 7 8 9 10
2 3 4 5
Specifications
6. DVI port7. HDMI port8. USB port9. RJ45 data port10. Power port
Diagram:
MC-F power box
Working Voltage 100-240VAC
Power Output 4000W
Working temperature
DC36V Output 2 ports available
Mounting Fixed on Head / Settle on the ground
Max Capacity 16 tiles / 8 tiles per port
Material SPCC
Dimension L420xW380xH130mm
Weight 12.55kg
IP IP62
Power box (202000S0003)
Power box (202000S0003)
POWER 2
POWER 1
AC OUT
36V DC OUT2 36V DC OUT1
INPUT:100-240VAC
36V DC OUT4 36V DC OUT3
-20°C~45°C
Specification
User Manual P14
The Power box can be suspended on the truss, also can be settled on the ground in smart �ight case.
Figure 1: Installation on the truss
A
A
C
Figure 2: Installation in the �ight case
Power box installation:
User Manual P15
1. Loosen six buttons and replace the faulty strips.2. Do repair for the faulty strips.
Note: When the failure occurs,the color of indicator light will show the prority in the following order.1. Error receiving card.2. The power is above 36V or below 24V3. Excessive tile temperature.4. Wrong signal.5. No signal.
OK Signal input from topto bottom
Green (2Hz/second) Normal
Normal
The receiving card doesn’t work.
The supply voltage is above 36V or below 24V.
The temperature of tile exceeds 50°C
1.The bad connection between the receiving cards.2.The pins on the receiving card is curved or broken.
Disconnected the UTP cable between the receivingcard and the tile.
Blue (2Hz/second)
Red (Always)
Red (2Hz/second)
Green (Always)
Blue (Always)
Yellow (2Hz/second)
Signal input frombottom to top
Error receiving card
OK
OK
Wrong signal
No signal
OK
OK
OK
OK
OK
Above 36V or below 24V
Power Data Color of Light Factors
Service and Maintenance:08
Figure 1: Maintenance on overall installation
Light status on the rear of MC-F series
Figure 2: Replacement of LED strips
User Manual P16
MC-9F MC-12F
MC-12FMC-18F
MC-18F
MC-12F
MC-12F
MC-18F
MC-18F
MC-18F
MC-18F
MC-18F
MC-18F
MC-18F
MC-18F
MC-12F
MC-12F
MC-12F
MC-12F
MC-12F
MC-12F
MC-9F
MC-9F
MC-7F
MC-7F
MC-7F
MC-7F
MC-9F
MC-7F
MC-9F
Package09
User Manual P17
12 pcs LED tiles per flightcase
Flightcase
User Manual P18
ROE Visual Co., LtdROE Visual Europe B.V ROE Visual US, Incwww.roevisual.com www.roevisual.comwww.roevisual.com
Bldg 7, Zhong Yuntai Industrial Park,Shiyan Town, Shenzhen, China.
E: [email protected]: +86-755-8392 4892F: +86-755-8392 4891
Zernikelaan 2a,9351VA Leek, The Netherlands.
E: [email protected]: +31 683 652 537
66 Maxwell,Irvine, CA, 92618.
E: [email protected]: +1 747 229 9190