using ct scan in the industry -
TRANSCRIPT
![Page 1: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/1.jpg)
© Dantherm A/S
Using CT Scan in the IndustryWhat does CT scanning have to do with cooling systems for Telecom? – working with Danish Technological Institute.
Pia Grandelag Marketing and Sustainability Manager Dantherm Cooling Holding A/S
![Page 2: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/2.jpg)
© Dantherm A/S
SPECIFIC FOCUS ON CT AND THERMOSIPHON
Do the cooling coils we source live up to our specifications?
How do we ensure specified quality when soldering?
![Page 3: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/3.jpg)
© Dantherm A/S
Dantherm specialty: Energy-efficient climate control solutions for shelters and cabinets
In both types of telecom sites thermosiphons are relevant as method of thermal management in the site. This presentations focuses specifically on CT Scanning in relation to the thermosiphon
SHELTER CLIMATE CONTROL
CABINET CLIMATE CONTROL
![Page 4: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/4.jpg)
© Dantherm A/S
A thermosiphon is a passive cooling system consisting of:
1. An evaporator coil2. A condenser coil3. An airflow through the evaporator (via fan)4. An airflow through the condenser (via fan)5. Piping and soldering6. Gravity
What does a thermosiphon consist of?
![Page 5: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/5.jpg)
© Dantherm A/S 5
How does it work…https://www.youtube.com/watch?v=-VgqS9Ky0tM
![Page 6: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/6.jpg)
© Dantherm A/S
The coil consists of:1. 2 headers2. MPE-pipes3. Zipper fins between
the MPE-pipes4. Louver fins, stamped out
in the zipper fins
Evaporator / condenser coils
HeaderMPE pipes
Zipper fins
Zipper fins
Louver fins
![Page 7: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/7.jpg)
© Dantherm A/S
Do the cooling coils we source live up to our specifications?
![Page 8: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/8.jpg)
© Dantherm A/S
To answer this, we used microscopy (and grind /cut)
Microscopy is a well-known and reliable method, but relatively expensive and time consuming
![Page 9: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/9.jpg)
© Dantherm A/S
Our first scan was a section of a coil
After intro to the AM cluster of Teknologisk Institut in Denmark, we participated in the first meeting for CT scans
Our first assumptions were incorrect: the zipper fin angles were correct, but the scan showed an issue the header material. This was a corrective result, which we could not have achieved via the first method.
![Page 10: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/10.jpg)
© Dantherm A/S
How do we ensure specified quality when soldering?
![Page 11: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/11.jpg)
© Dantherm A/S
Like this? … well no…
![Page 12: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/12.jpg)
© Dantherm A/S
Sample taking
6 different soldering methods
Like this:
![Page 13: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/13.jpg)
© Dantherm A/S
Scan of all 30 samples
![Page 14: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/14.jpg)
© Dantherm A/S
![Page 15: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/15.jpg)
© Dantherm A/S
Aluminum soldering
![Page 16: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/16.jpg)
© Dantherm A/STitle of presentation DD/MM/YY Author Confidentiality level
Presentation of the results
![Page 17: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/17.jpg)
© Dantherm A/STitle of presentation DD/MM/YY Author Confidentiality level
APPROVED REJECTED
![Page 18: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/18.jpg)
© Dantherm A/STitle of presentation DD/MM/YY Author Confidentiality level
Microscopy comparison
![Page 19: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/19.jpg)
© Dantherm A/S
Sample 2
![Page 20: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/20.jpg)
© Dantherm A/S
Sample 4
![Page 21: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/21.jpg)
© Dantherm A/S
Analysis of the entire sampleScan is quickly performed Fast result presentation and thereby fast reaction of corrective actions towards unwanted performance.Visual result, easy to communicate Cost-efficient.
Analysis of cut area onlyDestructive Time consumingLong reaction time and long waiting time to be able to make corrective actions
CT Scan
Microscopy analysis
Evaluating CT Scan vs microscopy analyses
![Page 22: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/22.jpg)
© Dantherm A/S
Dantherm: leading provider of mission-critical climate control solutions
Founded in 1958 in Denmark
Two main business areas:
Telecom (total heat management for radio base stations and electronics cooling)HVAC (heating, ventilation, air conditioning)
Listed on NASDAQ OMX Copenhagen
Companies in China, USA, UK, Germany, Poland, Sweden, Norway and Denmark
Dantherm facts:
www.dantherm.com
![Page 23: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/23.jpg)
© Dantherm A/S
Reliable cooling – reliable communication worldwide
In a world increasingly dependent on wireless and broadband communication, we ensure that radios, electronics and backup systems are working under all climate conditions and circumstances.
900,000 energy-efficient climate control products deployed worldwide to network suppliers and network operators
What we do… Select Telecom references
▶ INTRO ▶ DANTHERM COOLING
▶ PRODUCTS ▶ VALUE ADDING SOLUTIONS
▶ COMPANY DETAILS
▶ YOUR BENEFITS
PERSPECTIVE R&D ENERGY EFFICIENCY RANKING WHY WORK WITH DANTHERM CASE STUDIES
![Page 24: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/24.jpg)
© Dantherm A/S
World leader in energy-efficient climate control solutions for Telecom
Customer Segments:Network SuppliersNetwork OperatorsElectronics Cooling (Industry & ICT)
We offer a global one-stop-shop for:
Shelter solutionsTotal shelter climate controlBattery compartment coolingEmergency cooling
Cabinet solutionsBattery compartment coolingElectronics cooling
▶ INTRO ▶ DANTHERM COOLING
▶ PRODUCTS ▶ VALUE ADDING SOLUTIONS
▶ COMPANY DETAILS
▶ YOUR BENEFITS
PERSPECTIVE R&D ENERGY EFFICIENCY RANKING WHY WORK WITH DANTHERM CASE STUDIES
![Page 25: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/25.jpg)
© Dantherm A/S
Telecom- three regional head quarters
EMEA APACAMERICASSpartanburg, SC, USAR&D, manufacturingSales & customer supportRepresentation in Mexico
Skive, DenmarkR&D, manufacturingSales & customer supportSubsidiary companies: Sweden, Norway, Germany and UK.Representation in Russia & France
Suzhou, ChinaR&D, manufacturingSales & customer supportBranch office: Beijing
![Page 26: Using CT Scan in the Industry -](https://reader036.vdocuments.net/reader036/viewer/2022062523/58edb0201a28abb3038b4597/html5/thumbnails/26.jpg)
© Dantherm A/S
Contact Dantherm for more info at [email protected]