Key features at a glance Products 2001 – Subject to change – 01/04 Vol.3 / 10.2-0 Festo AG & Co. M-series service units Compressed air preparation M-series service units – Manual condensate drain – Automatic condensate drain -V- New Soft-start valve HEMS – Individual compressed air preparation – Modular and flexible – A complete series of service units for compressed air preparation, in three sizes M1, M2 and M3 – The individual service units can be combined with one another Festo provides the M series with a comprehensive accessory range: – Mounting brackets – Connectors – Piping connectors – Regulator adjustment locks – Pressure gauges – Pressure switches Accessories è Vol.3 / 10.2-72 10.2

Upload: others

Post on 19-May-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Key features at a glance

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-0 Festo AG & Co.

M-series service unitsCompressed air preparation

M-series service units – Manual condensate drain

– Automatic condensate drain

-V- New

Soft-start valve

HEMS

– Individual compressed air

preparation

– Modular and flexible

– A complete series of service units

for compressed air preparation, in

three sizes M1, M2 and M3

– The individual service units can be

combined with one another

Festo provides the M series with a

comprehensive accessory range:

– Mounting brackets

– Connectors

– Piping connectors

– Regulator adjustment locks

– Pressure gauges

– Pressure switches

Accessories� Vol.3 / 10.2-72

10.2

Page 2: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Key features at a glance

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-1Festo AG & Co.

M-series service unitsCompressed air preparation

Individual units

1 Piping connector LVR-M

2 Manual on-off valve

3 Compressed air filter/regulator LFR-M

4 Mounting bracket HW-M

5 Connector LV-M

6 Branching module FRM-M

7 Lubricator LOE-M

8 Pressure regulator LR-M

9 Soft-start valve HEM-M

aJ Pressure switch PEV

and double nipple ESK-�-�

The series is characterised by its many

variants:

– 4 pressure ranges:

4, 7, 10 and 16 bar

– Grade of filtration 40, 5, 1 and

0.01 µm

– Active carbon filter

– 5 connection sizes: G�, G�, G�,

G� , G�

– Bowl types

– Plastic without drain

– Plastic with manual drain

– Plastic with automatic drain

– Metal without drain

– Metal with manual drain

– Metal with automatic drain

– Plastic bowl with bowl guard

(standard)

1

2

3

4

5

6

8

7

69

aJ

Sizes M1 M2 M3

es

G�

nsizes

G�

ection G�

onnec

G�

Co G�

10.2

Page 3: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Type code

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-2 Festo AG & Co.

M-series service unitsCompressed air preparation

Function

LR Pressure regulator

LRB Pressure regulator for mani-

fold assembly

LF Compressed air filter

LFM Fine and micro filters

LFR Compressed air filter and

regulator

LOE Compressed air lubricator

FRC Compressed air service unit

HEA Manual on-off valve (flow from

left to right)

HEB Manual on-off valve (flow from

right to left)

HEL Soft-start valve

HEM Soft-start valve with dump

function and quick exhaust

HEMS Soft-start valve without

manual override

FRM Branching module

LD Membrane air dryer

Series

M = Modular

Size

1 = Size 1

2 = Size 2

3 = Size 3

Thread type

G = G thread

N = NPT thread

Connection size

� = G�

� = G�

� = G�

� = G�

� = G�

M– ––

10.2

Page 4: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Type code

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-3Festo AG & Co.

M-series service unitsCompressed air preparation

Options

G = With pressure gauge

I = Return flow

K = Without secondary venting

Y = PEV-�-B

Z = PEV-�-SC-OD with display

000 = Pneumatic actuation

024 = 24 V DC

110 = 110 V AC

230 = 230 V AC

1 = Cartridge size 1

2 = Cartridge size 2

3 = Cartridge size 3

4 = Cartridge size 4

Bowls

P = Plastic/without drain

R = Plastic/manual drain

S = Plastic/automatic drain

Q = Metal/without drain

T = Metal/manual drain with sight

glass

U = Metal/automatic drain with

sight glass

Pressure regulation range

04 = 0 ... 4 bar

07 = 0 ... 7 bar

10 = 0 ... 10 bar

16 = 0 ... 16 bar

Grade of filtration

A = 0.01 µm

B = 1 µm

C = 5 µm

E = 40 µm

X = Active carbon filter

Exceptions� individual units

Dew point

STD = Standard –40 °C

ECO = Economy –20 °C

10.2

Page 5: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Product range overview

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-4 Festo AG & Co.

M-series service unitsCompressed air preparation

Connection Grade of filtration Pressure regulation range Dew point

* Delivery time approx. 5 weeks

** Not for versions with plastic bowls

*** Not for versions with automatic conden-

sate drain G�

G�

G�

G�

G�

NPT�

...1

0.01µm

1µm

5µm

40µm

Active

carbon

filter

0–4bar

0–7bar

0–10bar

0–16bar

Standard

–20°C

(–40°C)

Econom

y–20°C

Designation

Type

Size � � � � � N A B C E X 04 07 10 16 STD ECO

Pressure regulators 1 – – – * – – – – – – – –g

LR-... 2 – – * – – – – – – –

� Vol.3 / 10.2-6 3 – – * – – – – – * – –

Pressure regulators

LRB-1 – – – – * – – – – – – – –

LRB-...

� Vol.3 / 10.2-6 2 – – – – * – – – – – – –

Filters 1 – – – * – – – – – – – – –

LF-... 2 – – * – – – – – – – – –

� Vol.3 / 10.2-6 3 – – * – – – – – – – – –

Fine/micro filters 1 – – – – * – – *** – – – – – –/

LFM-... 2 – – * – – *** – – – – – –

� Vol.3 / 10.2-7 3 – – * – – *** – – – – – –

Filter regulators 1 – – – * – – – * – – –g

LFR-... 2 – – * – – – * ** – –

� Vol.3 / 10.2-7 3 – – * – – – * ** – –

Lubricator 1 – – – * – – – – – – – – – – –

LOE-... 2 – – * – – – – – – – – – – –

� Vol.3 / 10.2-8 3 – – * – – – – – – – – – – –

Service unit 1 – – – * – – – * – – –

FRC-... 2 – – * – – – * ** – –

� Vol.3 / 10.2-8 3 – – * – – – * ** – –

Manual on-off valves 1 – – – * – – – – – – – – – – –

HEA-... 2 – – * – – – – – – – – – – –

� Vol.3 / 10.2-9 3 – – * – – – – – – – – – – –

Manual on-off valves

HEB-2 – – * – – – – – – – – – – –

HEB-...

� Vol.3 / 10.2-9 3 – – * – – – – – – – – – – –

Soft-start valves

HEM(S)-2 – – * – – – – – – – – –

HEM(S)-...

� Vol.3 / 10.2-9 3 – – * – – – – – – – – –

Soft-start valves

HEL-2 – – * – – – – – – – – – –

HEL-...

� Vol.3 / 10.2-10 3 – – * – – – – – – – – – –

Branching module 1 – – – – * – – – – – – – – – – –g

FRM-... 2 – – – – * – – – – – – – – – – –

� Vol.3 / 10.2-10 3 – – – – * – – – – – – – – – – –

Membrane air dryer

LD-...

� Vol.3 / 10.2-10

3 – – – – * – – – – – – – – –

Service unit combinations

LFR FRC1 – – – – * – – – – – – – – –

LFR-..., FRC-...

� starting on2 – – – * – – – – – – – – –

� starting on

Vol.3 / 10.2-11 3 – – – – * – – – – – – – – –

10.2

Page 6: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Product range overview

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-5Festo AG & Co.

M-series service unitsCompressed air preparation

Bowls Options

Plastic

withoutdrain

Metal

withoutdrain

Plastic

manualdrain

Plastic

automaticdrain

Metal

manualdrain

Metal

automaticdrain

Withpressuregauge

Withoutpressuregauge

Returnflow

Withoutsecondary

venting

Pressureswitch

type:PEV-�

B

Pressureswitch

with

displayPEV-�-SC-OD

Pneumaticactuation

24VDC

110VAC

230AC

Withoutmanual

override

Cartridgesize1

Cartridgesize2

Cartridgesize3

Cartridgesize4

P Q R S T U G I K Y Z 000 024 110 230 1 2 3 4

– – – – – – * * – – – – – – – – – – –

– – – – – – * * – – – – – – – – – – –

– – – – – – * * – – – – – – – – – – –

– – – – – – – – * – – – – – – – – – – –

– – – – – – – – * – – – – – – – – – – –

– – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – –

– – – * – – – – – – – – – – –

– – – * – – – – – – – – – – –

– – – * – – – – – – – – – – –

– – – – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – – – –

– – – * – – – – – – – – – – –

– – – * – – – – – – – – – – –

– – – * – – – – – – – – – – –

– – – – – – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – (S) – – – –

– – – – – – – – – – – – – (S) – – – –

– – – – – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – –

– – – – – – – – – – – – – – – – –

10.2

Page 7: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Overview and ordering data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-6 Festo AG & Co.

Pressure regulators/filters LR/LRB/LFM-series service units

Size Connection

M1 G�

G�

Pressure regulator

LR

with detenting regulator knob

Pressure regulator

LRB

with detenting regulator knob

Filter

LF

G�

Pressure regulation range up to 10 bar Grade of filtration 40 µm and 5 µmM2 G� Without pressure gauge Manual condensate drain

G�

G�

M3 G�

G�

G�

178 703 LR-M1-G�-10

178 727 LR-M1-G�-10

178 751 LR-M2-G�-10

178 783 LR-M2-G�-10

178 815 LR-M2-G�-10

178 847 LR-M3-G�-10

178 879 LR-M3-G�-10

178 911 LR-M3-G�-10

182 938 LRB-M1-G�-10

182 944 LRB-M2-G�-10

182 627 LF-M1-G�-ER

182 635 LF-M1-G�-ER

182 643 LF-M2-G�-ER

182 651 LF-M2-G�-ER

182 659 LF-M2-G�-ER

182 667 LF-M3-G�-ER

182 675 LF-M3-G�-ER

182 683 LF-M3-G�-ER

With pressure gauge Automatic condensate drain

178 704 LR-M1-G�-10G

178 728 LR-M1-G�-10G

178 752 LR-M2-G�-10G

178 784 LR-M2-G�-10G

178 816 LR-M2-G�-10G

178 848 LR-M3-G�-10G

178 880 LR-M3-G�-10G

178 912 LR-M3-G�-10G

182 628 LF-M1-G�-ES

182 636 LF-M1-G�-ES

182 644 LF-M2-G�-ES

182 652 LF-M2-G�-ES

182 660 LF-M2-G�-ES

182 668 LF-M3-G�-ES

182 676 LF-M3-G�-ES

182 684 LF-M3-G�-ES

Pressure regulation range up to 7 bar Filter cartridge 5 µm

With pressure gauge Without pressure gauge Manual condensate drain

178 696 LR-M1-G�-07G

178 720 LR-M1-G�-07G

178 744 LR-M2-G�-07G

178 776 LR-M2-G�-07G

178 808 LR-M2-G�-07G

178 840 LR-M3-G�-07G

178 872 LR-M3-G�-07G

178 904 LR-M3-G�-07G

182 937 LRB-M1-G�-07

182 943 LRB-M2-G�-07

182 623 LF-M1-G�-CR

182 631 LF-M1-G�-CR

182 639 LF-M2-G�-CR

182 647 LF-M2-G�-CR

182 655 LF-M2-G�-CR

182 663 LF-M3-G�-CR

182 671 LF-M3-G�-CR

182 679 LF-M3-G�-CR

Without pressure gauge Automatic condensate drain

178 695 LR-M1-G�-07

178 719 LR-M1-G�-07

178 743 LR-M2-G�-07

178 775 LR-M2-G�-07

178 807 LR-M2-G�-07

178 839 LR-M3-G�-07

178 871 LR-M3-G�-07

178 903 LR-M3-G�-07

182 624 LF-M1-G�-CS

182 632 LF-M1-G�-CS

182 640 LF-M2-G�-CS

182 648 LF-M2-G�-CS

182 656 LF-M2-G�-CS

182 664 LF-M3-G�-CS

182 672 LF-M3-G�-CS

182 680 LF-M3-G�-CS

Technical data/dimensions

� starting on Vol.3 / 10.2-16

Technical data/dimensions

� starting on Vol.3 / 10.2-20

Technical data/dimensions

� starting on Vol.3 / 10.2-24

Mounting accessories Pressure gauge� Vol.3 / 10.2-74 Filter cartridge 40 µm and 5 µm

Pressure sensor� Vol.3 / 10.2-80

g µ µ

� Vol.3 / 10.2-75

Mounting brackets, connectors, piping connectors, adjustment locks,

mounting nuts� starting on Vol.3 / 10.2-72

Mounting brackets, connectors,

piping connectors

� starting on Vol.3 / 10.2-72

10.2

Page 8: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Overview and ordering data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-7Festo AG & Co.

Fine/micro filters and pressure regulators LFM/LFRM-series service units

Fine and micro filter

LFM

Filter regulator

LFR

with detenting regulator knob

Size Connection

M1 G�

G�G�

Pressure regulation range up to 10 bar

Fine filter 1 µm Grade of filtration 40 µm Grade of filtration 5 µm M2 G�

With pressure gauge G�

Manual condensate drain G�

182 751 LFM-M1-G�-BR

182 759 LFM-M2-G�-BR

182 771 LFM-M2-G�-BR

182 783 LFM-M2-G�-BR

182 795 LFM-M3-G�-BR

182 807 LFM-M3-G�-BR

182 819 LFM-M3-G�-BR

179 211 LFR-M1-G�-E10RG

179 307 LFR-M1-G�-E10RG

179 409 LFR-M2-G�-E10RG

179 521 LFR-M2-G�-E10RG

179 633 LFR-M2-G�-E10RG

179 745 LFR-M3-G�-E10RG

179 857 LFR-M3-G�-E10RG

179 969 LFR-M3-G�-E10RG

179 199 LFR-M1-G�-C10RG

179 295 LFR-M1-G�-C10RG

179 395 LFR-M2-G�-C10RG

179 507 LFR-M2-G�-C10RG

179 619 LFR-M2-G�-C10RG

179 731 LFR-M3-G�-C10RG

179 843 LFR-M3-G�-C10RG

179 955 LFR-M3-G�-C10RG

M3 G�

G�

G�

Automatic condensate drain

182 752 LFM-M1-G�-BS

182 760 LFM-M2-G�-BS

182 772 LFM-M2-G�-BS

182 784 LFM-M2-G�-BS

182 796 LFM-M3-G�-BS

182 808 LFM-M3-G�-BS

182 820 LFM-M3-G�-BS

179 212 LFR-M1-G�-E10SG

179 308 LFR-M1-G�-E10SG

179 410 LFR-M2-G�-E10SG

179 522 LFR-M2-G�-E10SG

179 634 LFR-M2-G�-E10SG

179 746 LFR-M3-G�-E10SG

179 858 LFR-M3-G�-E10SG

179 970 LFR-M3-G�-E10SG

179 200 LFR-M1-G�-C10SG

179 296 LFR-M1-G�-C10SG

179 396 LFR-M2-G�-C10SG

179 508 LFR-M2-G�-C10SG

179 620 LFR-M2-G�-C10SG

179 732 LFR-M3-G�-C10SG

179 844 LFR-M3-G�-C10SG

179 956 LFR-M3-G�-C10SG

Pressure regulation range up to 7 bar

Micro filter 0.01 µm Grade of filtration 40 µm or 5 µm Grade of filtration 5 µm

With pressure gauge

Manual condensate drain

183 769 LFM-M1-G�-AR

182 755 LFM-M2-G�-AR

182 767 LFM-M2-G�-AR

182 779 LFM-M2-G�-AR

182 791 LFM-M3-G�-AR

182 803 LFM-M3-G�-AR

182 815 LFM-M3-G�-AR

179 207 LFR-M1-G�-E07RG

179 303 LFR-M1-G�-E07RG

179 405 LFR-M2-G�-E07RG

179 517 LFR-M2-G�-E07RG

179 629 LFR-M2-G�-E07RG

179 741 LFR-M3-G�-E07RG

179 853 LFR-M3-G�-E07RG

179 965 LFR-M3-G�-E07RG

179 195 LFR-M1-G�-C07RG

179 291 LFR-M1-G�-C07RG

179 391 LFR-M2-G�-C07RG

179 503 LFR-M2-G�-C07RG

179 615 LFR-M2-G�-C07RG

179 727 LFR-M3-G�-C07RG

179 839 LFR-M3-G�-C07RG

179 951 LFR-M3-G�-C07RG

Automatic condensate drain

183 770 LFM-M1-G�-AS

182 756 LFM-M2-G�-AS

182 768 LFM-M2-G�-AS

182 780 LFM-M2-G�-AS

182 792 LFM-M3-G�-AS

182 804 LFM-M3-G�-AS

182 816 LFM-M3-G�-AS

179 208 LFR-M1-G�-E07SG

179 304 LFR-M1-G�-E07SG

179 406 LFR-M2-G�-E07SG

179 518 LFR-M2-G�-E07SG

179 630 LFR-M2-G�-E07SG

179 742 LFR-M3-G�-E07SG

179 854 LFR-M3-G�-E07SG

179 966 LFR-M3-G�-E07SG

179 196 LFR-M1-G�-C07SG

179 292 LFR-M1-G�-C07SG

179 392 LFR-M2-G�-C07SG

179 504 LFR-M2-G�-C07SG

179 616 LFR-M2-G�-C07SG

179 728 LFR-M3-G�-C07SG

179 840 LFR-M3-G�-C07SG

179 952 LFR-M3-G�-C07SG

Technical data/dimensions

� starting on Vol.3 / 10.2-28

Technical data/dimensions� starting on Vol.3 / 10.2-32

Mounting accessories

Filter cartridge 1 µm and 0.01 µm Pressure gauge� Vol.3 / 10.2-74g µ µ

� starting on Vol.3 / 10.2-75 Pressure sensor� Vol.3 / 10.2-80

Mounting brackets, connectors,

piping connectors

� starting on Vol.3 / 10.2-72

Mounting brackets, connectors, piping connectors, adjustment locks,

mounting nuts, filter cartridges� starting on Vol.3 / 10.2-72

10.2

Page 9: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Overview and ordering data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-8 Festo AG & Co.

Lubricators/service units LOE/FRCM-series service units

Size Connection

M1 G�

G�

Lubricator

LOE

Service unit

FRC

with detenting regulator knob, including mounting bracket

M2 G� Operating pressure 12 bar Pressure regulation range 10 barG� Direct proportional lubricator Grade of filtration 40 µm Grade of filtration 5 µmG� With pressure gauge

Manual condensate drainM3 G�

G�

G�

182 904 LOE-M1-G�-P

182 906 LOE-M1-G�-P

182 908 LOE-M2-G�-P

182 910 LOE-M2-G�-P

182 912 LOE-M2-G�-P

182 914 LOE-M3-G�-P

182 916 LOE-M3-G�-P

182 918 LOE-M3-G�-P

180 939 FRC-M1-G�-E10RG

181 035 FRC-M1-G�-E10RG

181 137 FRC-M2-G�-E10RG

181 249 FRC-M2-G-�E10RG

181 361 FRC-M2-G�-E10RG

181 473 FRC-M3-G�-E10RG

181 585 FRC-M3-G�-E10RG

181 697 FRC-M3-G�-E10RG

180 927 FRC-M1-G�-C10RG

181 023 FRC-M1-G�-C10RG

181 123 FRC-M2-G�-C10RG

181 235 FRC-M2-G-�C10RG

181 347 FRC-M2-G�-C10RG

181 459 FRC-M3-G�-C10RG

181 571 FRC-M3-G�-C10RG

181 683 FRC-M3-G�-C10RG�

Automatic condensate drain

180 940 FRC-M1-G�-E10SG

181 036 FRC-M1-G�-E10SG

181 138 FRC-M2-G�-E10SG

181 250 FRC-M2-G�-E10SG

181 362 FRC-M2-G�-E10SG

181 474 FRC-M3-G�-E10SG

181 586 FRC-M3-G�-E10SG

181 698 FRC-M3-G�-E10SG

180 928 FRC-M1-G�-C10SG

181 024 FRC-M1-G�-C10SG

181 124 FRC-M2-G�-C10SG

181 236 FRC-M2-G�-C10SG

181 348 FRC-M2-G�-C10SG

181 460 FRC-M3-G�-C10SG

181 572 FRC-M3-G�-C10SG

181 684 FRC-M3-G�-C10SG

Working pressure 7 bar

Filter cartridge 40µm Filter cartridge 5µm

With pressure gauge

Manual condensate drain

180 935 FRC-M1-G�-E07RG

181 031 FRC-M1-G�-E07RG

181 133 FRC-M2-G�-E07RG

181 245 FRC-M2-G�-E07RG

181 357 FRC-M2-G�-E07RG

181 469 FRC-M3-G�-E07RG

181 581 FRC-M3-G�-E07RG

181 693 FRC-M3-G�-E07RG

180 923 FRC-M1-G�-C07RG

181 019 FRC-M1-G�-C07RG

181 119 FRC-M2-G�-C07RG

181 231 FRC-M2-G�-C07RG

181 343 FRC-M2-G�-C07RG

181 455 FRC-M3-G�-C07RG

181 567 FRC-M3-G�-C07RG

181 679 FRC-M3-G�-C07RG

Automatic condensate drain

180 936 FRC-M1-G�-E07SG

181 032 FRC-M1-G�-E07SG

181 134 FRC-M2-G�-E07SG

181 246 FRC-M1-G�-E07SG

181 358 FRC-M2-G�-E07SG

181 470 FRC-M1-G�-E07SG

181 582 FRC-M3-G�-E07SG

181 694 FRC-M3-G�-E07SG

180 924 FRC-M1-G�-C07SG

181 020 FRC-M1-G�-C07SG

181 120 FRC-M2-G�-C07SG

181 232 FRC-M1-G�-C07SG

181 344 FRC-M2-G�-C07SG

181 456 FRC-M1-G�-C07SG

181 568 FRC-M3-G�-C07SG

181 680 FRC-M3-G�-C07SG

Technical data/dimensions

� starting on Vol.3 / 10.2-36

Technical data/dimensions� starting on Vol.3 / 10.2-40

Mounting accessories Mounting brackets, connectors,

piping connectors, lubricator

protective covers

Mounting brackets, connectors, piping connectors, adjustment locks,

mounting nuts, filter cartridges, lubricator protective covers

� starting on Vol.3 / 10.2-72p

� starting on Vol.3 / 10.2-72 Pressure gauge� Vol.3 / 10.2-74� starting on Vol.3 / 10.2 72

Pressure sensor� Vol.3 / 10.2-80

10.2

Page 10: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Overview and ordering data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-9Festo AG & Co.

Manual on-off valves/soft-start valves HEA/HEB/HEM/HEMSM-series service units

Manual on-off valve

HEA/HEB

Soft-start valve

HEM

with solenoid coil, without plug socket

Soft-start valve

HEMS

with solenoid coil, without plug

socket, without manual override

Size Connection

M1 G�

G�

Operating pressure 12 bar Pressure range 2 ... 10 bar Pressure range 2 ... 16 bar M2 G�

Direction of flow from left to right Voltage 24 V DC G�

183 001 HEA-M1-G�

183 002 HEA-M1-G�

183 003 HEA-M2-G�

183 004 HEA-M2-G�

183 005 HEA-M2-G�

183 006 HEA-M3-G�

183 007 HEA-M3-G�

183 008 HEA-M3-G�

183 039 HEM-M2-G�-10024

183 042 HEM-M2-G�-10024

183 045 HEM-M2-G�-10024

183 048 HEM-M3-G�-10024

183 051 HEM-M3-G�-10024

183 054 HEM-M3-G�-10024

193 701 HEMS-M2-G�-16024

193 704 HEMS-M2-G�-16024

193 707 HEMS-M2-G�-16024

193 710 HEMS-M3-G�-16024

193 713 HEMS-M3-G�-16024

193 716 HEMS-M3-G�-16024

G�

M3 G�

G�

G�

Direction of flow from right to left Voltage 110 V AC

183 009 HEB-M2-G�

183 010 HEB-M2-G�

183 011 HEB-M2-G�

183 012 HEB-M3-G�

183 013 HEB-M3-G�

183 014 HEB-M3-G�

183 040 HEM-M2-G�-10110

183 043 HEM-M2-G�-10110

183 046 HEM-M2-G�-10110

183 049 HEM-M3-G�-10110

183 052 HEM-M3-G�-10110

183 055 HEM-M3-G�-10110

193 702 HEMS-M2-G�-16110

193 705 HEMS-M2-G�-16110

193 708 HEMS-M2-G�-16110

193 711 HEMS-M3-G�-16110

193 714 HEMS-M3-G�-16110

193 717 HEMS-M3-G�-16110183 014 HEB M3 G�Voltage 230 V AC

183 041 HEM-M2-G�-10230

183 044 HEM-M2-G�-10230

183 047 HEM-M2-G�-10230

183 050 HEM-M3-G�-10230

183 053 HEM-M3-G�-10230

183 056 HEM-M3-G�-10230

193 703 HEMS-M2-G�-16230

193 706 HEMS-M2-G�-16230

193 709 HEMS-M2-G�-16230

193 712 HEMS-M3-G�-16230

193 715 HEMS-M3-G�-16230

193 718 HEMS-M3-G�-16230

Technical data/dimensions

� starting on Vol.3 / 10.2-44

Technical data/dimensions� starting on Vol.3 / 10.2-48

Mounting brackets, connectors,

piping connectors

Mounting brackets, connectors, piping connectors

� starting on Vol.3 / 10.2-72

Mounting accessories

p p g

� starting on Vol.3 / 10.2-72 Standard plug socketg /

34 583 MSSD-C

Plug socket with cable

30 931 KMC-1-24-2,5-LED

30 933 KMC-1-24-5-LED

30 932 KMC-1-220/230-2,5

30 934 KMC-1-220/230-5

10.2

Page 11: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Overview and ordering data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-10 Festo AG & Co.

Soft-start valves/branching modules/membrane air dryers HEL/FRM/LDM-series service units

Size Connection

M1 G�

Soft-start valve

HEL

with pneumatic actuation

Branching module

FRM

Membrane air dryer

LD

M2 G� Input pressure range 2 ... 16 bar Input pressure max. 21 bar Input pressure up to 12 barG� For atmospheric dew point –20 °CG�

M3 G�

G�

G�

183 015 HEL-M2-G�-16000

183 016 HEL-M2-G�-16000

183 017 HEL-M2-G�-16000

183 018 HEL-M3-G�-16000

183 019 HEL-M3-G�-16000

183 020 HEL-M3-G�-16000

182 965 FRM-M1-G�

182 971 FRM-M2-G�

182 977 FRM-M3-G�

183 754 LD-M3-G1/2-ECO1

183 756 LD-M3-G1/2-ECO2

183 758 LD-M3-G1/2-ECO3

183 760 LD-M3-G1/2-ECO4

For atmospheric dew point

–20 °C (–40 °C)

183 753 LD-M3-G1/2-STD1

183 755 LD-M3-G1/2-STD2

183 757 LD-M3-G1/2-STD3

183 759 LD-M3-G1/2-STD4

Technical data/dimensions

� starting on Vol.3 / 10.2-52

Technical data/dimensions

� starting on Vol.3 / 10.2-56

Technical data/dimensions

� starting on Vol.3 / 10.2-58

Mounting accessories Mounting brackets, connectors, piping connectors� starting on Vol.3 / 10.2-72

Standard plug socket Pressure switches, double nipples,

34 583 MSSD-C

, pp ,

plug sockets� starting

Plug socket with cable

p g g

on Vol.3 / 10.2-80

30 931 KMC-1-24-2.5-LED

30 933 KMC-1-24-5-LED

30 932 KMC-1-220/230-2,5

30 934 KMC-1-220/230-5

/

10.2

Page 12: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Overview and ordering data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-11Festo AG & Co.

Service unit combinations LFRM-series service units

LFR-M-...-KA LFR-M-...-KB LFR-M-...-KC Size ConnectionSize Connection

Consisting of:

– Filter regulator

– Branching module

– Mounting brackets

Consisting of:

– Manual on-off valve

– Filter regulator

– Branching module

– Mounting brackets

Consisting of:

– Manual on-off valve

– Filter regulator

– Mounting brackets

M1 G�

M2 G�

G�

Pressure regulation range up to 10 bar M3 G�

Grade of filtration 40 µm

With pressure gauge

Manual condensate drain

184 367 LFR-M1-G�-KA00

184 377 LFR-M2-G�-KA00

184 391 LFR-M2-G�-KA00

184 405 LFR-M3-G�-KA00

184 369 LFR-M1-G�-KB00

184 379 LFR-M2-G�-KB00

184 393 LFR-M2-G�-KB00

184 407 LFR-M3-G�-KB00

184 371 LFR-M1-G�-KC00

184 381 LFR-M2-G�-KC00

184 395 LFR-M2-G�-KC00

184 409 LFR-M3-G�-KC00

Automatic condensate drain

184 368 LFR-M1-G�-KA01

184 378 LFR-M2-G�-KA01

184 392 LFR-M2-G�-KA01

184 406 LFR-M3-G�-KA01

184 370 LFR-M1-G�-KB01

184 380 LFR-M2-G�-KB01

184 394 LFR-M2-G�-KB01

184 408 LFR-M3-G�-KB01

184 372 LFR-M1-G�-KC01

184 382 LFR-M2-G�-KC01

184 396 LFR-M2-G�-KC01

184 410 LFR-M3-G�-KC01

Technical data/dimensions� starting on Vol.3 / 10.2-61

Pressure gauge� Vol.3 / 10.2-74 Mounting accessories

Pressure sensors, plug sockets� starting on Vol.3 / 10.2-80

Mounting brackets, connectors, piping connectors, adjustment locks, mounting nuts and filter cartridges

� starting on Vol.3 / 10.2-72

– Available with manual conden-

sate drain or integrated, auto-

matic condensate drain

– For unlubricated compressed air

supply

– Three connections are available

– Available with manual conden-

sate drain or integrated, auto-

matic condensate drain

– For unlubricated compressed air

supply

– Three connections are available

– The supply pressure can be

switched on or off

– The unit is vented when switched

off

– Available with manual conden-

sate drain or integrated, auto-

matic condensate drain

– For unlubricated compressed air

supply

– The supply pressure can be

switched on or off

– The unit is vented when switched

off

10.2

Page 13: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Overview and ordering data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-12 Festo AG & Co.

Service unit combinations LFRM-series service units

Size Connection LFR-M-...-KD LFR-M-...-KE LFR-M-...-KFSize Connection

M1 G�

M2 G�

G�

M3 G�

Consisting of:

– Filter regulator

– Soft-start valve with solenoid coil

24 V DC, without plug socket

– Mounting brackets

Consisting of:

– Filter regulator

– Branching module with pressure

switch, without plug socket

– Mounting brackets

Consisting of:

– Manual on-off valve

– Filter regulator

– Branching module with pressure

switch, without plug socket

– Mounting brackets

Pressure regulation range up to 10 bar

Grade of filtration 40 µm

With pressure gauge

Manual condensate drain

184 383 LFR-M2-G�-KD00

184 397 LFR-M2-G�-KD00

184 411 LFR-M3-G�-KD00

184 373 LFR-M1-G�-KE00

184 385 LFR-M2-G�-KE00

184 399 LFR-M2-G�-KE00

184 413 LFR-M3-G�-KE00

184 375 LFR-M1-G�-KF00

184 387 LFR-M2-G�-KF00

184 401 LFR-M2-G�-KF00

184 415 LFR-M3-G�-KF00

Automatic condensate drain

184 384 LFR-M2-G�-KD01

184 398 LFR-M2-G�-KD01

184 412 LFR-M3-G�-KD01

184 374 LFR-M1-G�-KE01

184 386 LFR-M2-G�-KE01

184 400 LFR-M2-G�-KE01

184 414 LFR-M3-G�-KE01

184 376 LFR-M1-G�-KF01

184 388 LFR-M2-G�-KF01

184 402 LFR-M2-G�-KF01

184 416 LFR-M3-G�-KF01

Technical data/dimensions� starting on Vol.3 / 10.2-61

Mounting accessories Pressure gauge� Vol.3 / 10.2-74

Pressure sensors, plug sockets� starting on Vol.3 / 10.2-80

Mounting brackets, connectors, piping connectors, adjustment locks, mounting nuts and filter cartridges

� starting on Vol.3 / 10.2-72

– Available with manual conden-

sate drain or integrated, auto-

matic condensate drain

– For unlubricated compressed air

supply

– Gradual pressure build-up after

switching on prevents sudden

and uncontrolled actuator move-

ments

– Quick exhausting ensures that

pressure is rapidly reduced when

switching off

– Solenoid coil 24 V DC

– Available with manual conden-

sate drain or integrated, auto-

matic condensate drain

– For unlubricated compressed air

supply

– Two connections are available

– Electrical pressure monitoring

with adjustable switching

pressure

– Available with manual conden-

sate drain or integrated, auto-

matic condensate drain

– For unlubricated compressed air

supply

– The supply pressure can be

switched on or off

– Two connections are available

– Electrical pressure monitoring

with adjustable switching pres-

sure

– The unit is vented when switched

off

10.2

Page 14: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Overview and ordering data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-13Festo AG & Co.

Service unit combinations LFRM-series service units

LFR-M-...-KG Size ConnectionSize Connection

Consisting of:

– Manual on-off valve

– Filter regulator

– On-off valve with solenoid coil 24 V DC, without plug socket

– Soft-start valve

– Branching module with pressure switch, without plug socket

– Mounting brackets

M1 G�

M2 G�

G�

M3 G�

Pressure regulation range up to 10 bar

Grade of filtration 40 µm

With pressure gauge

Manual condensate drain

184 389 LFR-M2-G�-KG00

184 403 LFR-M2-G�-KG00

184 417 LFR-M3-G�-KG00

Automatic condensate drain

184 390 LFR-M2-G�-KG01

184 404 LFR-M2-G�-KG01

184 418 LFR-M3-G�-KG01

Technical data/dimensions� starting on Vol.3 / 10.2-61

Pressure gauge� Vol.3 / 10.2-74 Mounting accessories

Pressure sensors, plug sockets� starting on Vol.3 / 10.2-80

Mounting brackets, connectors, adjustment locks, mounting nuts and filter

cartridges� starting on Vol.3 / 10.2-72

– Available with manual condensate

drain or integrated, automatic con-

densate drain

– For unlubricated compressed air

supply

– The supply pressure can be

switched on or off

– Two connections are available

– Gradual pressure build-up after

switching on prevents sudden and

uncontrolled movement of the

downstream pneumatic compo-

nents

– Quick exhausting ensures that

pressure is rapidly reduced when

the soft-start valve is switched off

– Electrical pressure monitoring with

adjustable switching pressure

– Solenoid coil 24 V DC

10.2

Page 15: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Overview and ordering data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-14 Festo AG & Co.

Service unit combinations FRCM-series service units

Size Connection FRC-M-...-KA FRC-M-...-KB FRC-M-...-KCSize Connection

M1 G�

M2 G�

G�

M3 G�

Consisting of:

– Filter regulator

– Branching module

– Lubricator

– Mounting brackets

Consisting of:

– Filter regulator

– Branching module with pressure

switch, without plug socket

– Lubricator

– Mounting brackets

Consisting of:

– Manual on-off valve

– Filter regulator

– Branching module with pressure

switch, without plug socket

– Lubricator

– Mounting brackets

Pressure regulation range up to 10 bar

Grade of filtration 40 µm

With pressure gauge

Manual condensate drain

184 419 FRC-M1-G�-KA00

184 425 FRC-M2-G�-KA00

184 435 FRC-M2-G�-KA00

184 445 FRC-M3-G�-KA00

184 421 FRC-M1-G�-KB00

184 427 FRC-M2-G�-KB00

184 437 FRC-M2-G�-KB00

184 447 FRC-M3-G�-KB00

184 423 FRC-M1-G�-KC00

184 429 FRC-M2-G�-KC00

184 439 FRC-M2-G�-KC00

184 449 FRC-M3-G�-KC00

Automatic condensate drain

184 420 FRC-M1-G�-KA01

184 426 FRC-M2-G�-KA01

184 436 FRC-M2-G�-KA01

184 446 FRC-M3-G�-KA01

184 422 FRC-M1-G�-KB01

184 428 FRC-M2-G�-KB01

184 438 FRC-M2-G�-KB01

184 448 FRC-M3-G�-KB01

184 424 FRC-M1-G�-KC01

184 430 FRC-M2-G�-KC01

184 440 FRC-M2-G�-KC01

184 450 FRC-M3-G�-KC01

Technical data/dimensions� starting on Vol.3 / 10.2-61

Mounting accessories Pressure gauge� Vol.3 / 10.2-74

Pressure sensors, plug sockets� starting on Vol.3 / 10.2-80

Mounting brackets, connectors, adjustment locks, mounting nuts, filter cartridges and lubricator protective covers

� starting on Vol.3 / 10.2-72

– Available with manual condensate

drain or integrated, automatic

condensate drain

– For lubricated and unlubricated

compressed air supply

– Two connections are available for

unlubricated compressed air

supply

– One connection is available for

lubricated compressed air

– Available with manual condensate

drain or integrated, automatic

condensate drain

– For lubricated and unlubricated

compressed air supply

– One connection each available for

unlubricated and lubricated

compressed air

– Electrical pressure monitoring

with adjustable switching pres-

sure

– Available with manual condensate

drain or integrated, automatic

condensate drain

– For lubricated and unlubricated

compressed air supply

– One connection each available for

unlubricated and lubricated

compressed air

– The supply pressure can be

switched on or off

– Electrical pressure monitoring

with adjustable switching pres-

sure

– The unit is vented when switched

off

10.2

Page 16: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Overview and ordering data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-15Festo AG & Co.

Service unit combinations FRCM-series service units

FRC-M-...-KE FRC-M-...-KF Size ConnectionSize Connection

Consisting of:

– Filter regulator

– Lubricator

– Soft-start valve with solenoid coil

24 V DC, without plug socket

– Mounting brackets

Consisting of:

– Manual on-off valve

– Filter regulator

– Lubricator

– Soft-start valve with solenoid coil

24 V DC, without plug socket

– Branching module with pressure

switch, without plug socket

– Mounting brackets

M1 G�

M2 G�

G�

M3 G�

Pressure regulation range up to 10 bar

Grade of filtration 40 µm

With pressure gauge

Manual condensate drain

184 431 FRC-M2-G�-KE00

184 441 FRC-M2-G�-KE00

184 451 FRC-M3-G�-KE00

184 433 FRC-M2-G�-KF00

184 443 FRC-M2-G�-KF00

184 453 FRC-M3-G�-KF00

Automatic condensate drain

184 432 FRC-M2-G�-KE01

184 442 FRC-M2-G�-KE01

184 452 FRC-M3-G�-KE01

184 434 FRC-M2-G�-KF01

184 444 FRC-M2-G�-KF01

184 454 FRC-M3-G�-KF01

Technical data/dimensions� starting on Vol.3 / 10.2-61

Pressure gauge� Vol.3 / 10.2-74 Mounting accessories

Pressure sensors, plug sockets� starting on Vol.3 / 10.2-80

Mounting brackets, connectors, adjustment locks, mounting nuts, filter

cartridges and lubricator protective covers� starting on Vol.3 / 10.2-72

– Available with manual condensate

drain or integrated, automatic

condensate drain

– For lubricated compressed air

supply

– Gradual pressure build-up after

switching on prevents sudden and

uncontrolled movement of the

downstream pneumatic compo-

nents

– Quick exhausting ensures that

pressure is rapidly reduced when

switching off

– Solenoid coil 24 V DC

– Available with manual condensate

drain or integrated, automatic con-

densate drain

– For lubricated compressed air supply

– Two connections are available for

lubricated compressed air

– The supply pressure can be switched

on or off

– Gradual pressure build-up after

switching on prevents sudden and

uncontrolled actuator movements

– Quick exhausting ensures that

pressure is rapidly reduced when the

soft-start valve is switched off

– Electrical pressure monitoring with

adjustable switching pressure

– Solenoid coil 24 V DC

10.2

Page 17: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-16 Festo AG & Co.

Pressure regulators LRM-series service units

G� ... G� Pressure regulator

LR-M-...

– Good control characteristics with

low hysteresis and primary pres-

sure compensation

– Available with or without secondary

venting

– High flow rate with minimal pres-

sure drop

– Four pressure ranges available

– Settings secured via detent on

knob and push-in adjustment lockThe pressure regulator maintains a

constant operating pressure (second-

ary side), regardless of the pressure

variations in the system (primary

side) and the air consumption.

With the secondary venting, the oper-

ating pressure can also be reduced

without consuming devices.

knob and push-in adjustment lock

– Also suitable for installation into

control panels

– Two pressure gauge connections for

different fitting options

– Directly controlled diaphragm

regulator valve

– Optional with reverse flow for im-

proved venting from output 2 to

input 1

Technical data for pressure regulator

Size M1 M2 M3

Connection G� G� G� G� G� G� G� G�

Type of mounting In-line installation, mounting bracket or installation into control panel;

Combination: flanged

Mounting position Any

Standard nominal flow

rate*

qnN [l/min]

LR-M-...-10G 760 2200 3400 5050 4500 5200 5400 7500

LR-M-...-07G 1000 2200 4000 4700 4600 6900 8200 8400

Input pressure range Max. 21 bar

Pressure regulation range Max. 7 bar, 10 bar

Temperature range –10 ... +80°C

Materials Housing: die-cast Zn; regulator knob: acetal; protective cover: ABS; seals: NBR

Weight 0.316 kg 0.747 kg 1.013 kg

* Measured at p1 = 10 bar, p2 = 6 bar and �p = 1 bar

10.2

Page 18: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-17Festo AG & Co.

Pressure regulators LRM-series service units

LR-M1-G�-07-... LR-M1-G�-07-... Characteristic curves for flow rate*

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

LR-M2-G�-07-... LR-M2-G�-07-...

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

LR-M3-G�-07-...

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

* p1 = 10 bar

10.2

Page 19: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Type code

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-18 Festo AG & Co.

Pressure regulators LRM-series service units

Function

LR = Pressure

regulator Series

M = Modular

Size

1 = Size 1

2 = Size 2

3 = Size 3

Thread type

G = BSP

Connection size

� = G�

� = G�

� = G�

� = G�

� = G�

Options

G = With pressure gauge

I = Return flow

K = Without secondary venting

Pressure regulation range

04 = 0 ... 4 bar

07 = 0 ... 7 bar

10 = 0 ... 10 bar

16 = 0 ... 16 bar*

* Except size 1

L R M— ——

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

10.2

Page 20: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-19Festo AG & Co.

Pressure regulators LRM-series service units

1 Mounting bracket HWR (not

included in scope of delivery)

2 Second pressure gauge

connection G�

� Flow direction

LR-M1-...

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2

D5 L1 L2 L6 L7 L8

max.

L9 L10

LR-M1-... 40 67 21.3 40 2 44 68 8 22 G� 23 7 100 66 44 52.5 3.5 2 2

G�

1 Mounting bracket HWR (not

included in scope of delivery)

2 Second pressure gauge

connection G�

� Flow direction

LR-M2/M3-...

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1

D2 D5 L1 L2 L6 L7 L8

max.

L9

LR-M2-... 60 94 30 40 2.7 42 70 8 32 G� 41 7 137 93 57 66.5 5 3

G�

G�

LR-M3-... 73 108 36.5 49 2.7 47.6 76 8 38.5 G� 41 7 149 104 57 66.5 5 4

G�

G�

10.2

Page 21: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-20 Festo AG & Co.

Pressure regulators LRBM-series service units

G� ... G� Pressure regulator

LRB-M-...

with through pressure supply for

manifold assembly

The pressure regulator is suitable for

manifold assemblies with through air

supply on both sides, for configuring

of a regulator manifold with separate,

independent pressure ranges. There

i t t b th idis a pressure output on both sides.

– Good control characteristics with

low hysteresis and primary pres-

sure compensation

– Manifold assembly with through air

supplysupply

– For the configuring of a regulator

LRB-... Manifold

For the configuring of a regulator

manifold with separate, indepen-p , p

dent pressure ranges

– Four pressure ranges available

– Settings secured via detent on

k b d h i dj t t l kknob and push-in adjustment lock

– Directly controlled diaphragm

regulator valve

Technical data for pressure regulator

Size M1 M2

Connection G� G�

Type of mounting In-line installation, mounting bracket or installation into control panel;

Combination: flanged

Mounting position Any

Standard nominal flow qnN [l/min]

rate* LRB-M1-G�-10 620 –

LRB-M1-G�-07 740 –

LRB-M2-G�-10 – 1440

LRB-M2-G�-07 – 1450

Input pressure range Max. 21 bar

Pressure regulation range Max. 7 bar, 10 bar

Temperature range –10 ... +80°C

Materials Housing: die-cast Zn; regulator knob: acetal; protective cover: ABS; seals: nitrile

Weight 0.244 kg 0.575 kg

* Measured at p1 = 10 bar, p2 = 6 bar and �p = 1 bar

10.2

Page 22: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-21Festo AG & Co.

Pressure regulators LRBM-series service units

LRB-M1-G�-10-... LRB-M1-G�-07-... Characteristic curves for flow rate*

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

LRB-M2-G�-10-... LRB-M2-G�-07-...

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

* p1 = 10 bar

10.2

Page 23: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Type code

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-22 Festo AG & Co.

Pressure regulators LRBM-series service units

Function

LRB = Pressure regulator

for manifold assembly Series

M = Modular

Size

1 = Size 1

2 = Size 2

Thread type

G = BSP

Connection size

� = G�

� = G�

Options

K = Without secondary venting

Pressure regulation range

04 = 0 ... 4 bar

07 = 0 ... 7 bar

10 = 0 ... 10 bar

16 = 0 ... 16 bar*

* Except size 1

L R B M— —

1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

10.2

Page 24: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-23Festo AG & Co.

Pressure regulators LRBM-series service units

LRB-M1-...

3 Second connection for regulated

output pressure

4 Mounting bracket LVH (not

included in scope of delivery)

� Flow direction

Type B1 B2 B3 B4 B8 B9 D1 D2

D3 D5 L1 L2 L6 L7 L8

max.

L9 L13

LRB-M1-... 40 42.6 21.3 40 2 22 G� – G� 5.5 100 66 45 35 3.5 2 100

LRB-M2-...

3 Second connection for regulated

output pressure

5 Mounting bracket LVH (not

included in scope of delivery)

� Flow direction

Type B1 B2 B3 B4 B5 B6 B8 B9 D1 D2

D3 D5 L1 L2 L6 L7 L8

max.

L9

LRB-M2-... 60 60 30 40 2 64.5 3 32 G� – G� 7 137 93 41.5 49 5 3

10.2

Page 25: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-24 Festo AG & Co.

Filters LFM-series service units

G� ... G� Filter

LF-M-...

The sintered filter with water separ-

ator removes dirt, pipe sinter, rust

and condensate from the compressed

air.

The filter cartridges are exchangeable.

– Good particle and condensate

separation

– High flow rate with minimal

pressure drop

– Option of 40 or 5 µm filter

cartridge

– Available with manual condensate

drain or integrated, automatic

condensate drain

Technical data for filter

Size M1 M2 M3

Connection G� G� G� G� G� G� G� G�

Type of mounting In-line installation, mounting bracket or installation into control panel;

Combination: flanged

Mounting position Vertical ±5°

Standard nominal flow

rate*

qnN [l/min]

LF-M-...(ER/ES-40 µm) 1100 1800 2700 4400 5900 4700 6100 7600

LF-M-...(CR/CS-5 µm) 1100 1700 2600 4400 5800 4600 6000 7500

Input pressure range Max. 12 bar

Grade of filtration 40 µm, 5 µm

Condensate volume 10 ml 53 ml 65 ml

Temperature range –10 ... +60°C (M1: –10 ... +40°C)

Materials Housing: die-cast Zn; protective cover: ABS; plastic bowl: polyamide; metal bowl: die-cast Zn; seals: NBR

Weight 0.20 kg 0.482 kg 0.842 kg

* Measured at p1 = 6 bar and �p = 1 bar

10.2

Page 26: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-25Festo AG & Co.

Filters LFM-series service units

LF-M1-G�-C-... LF-M1-G�-C-... Characteristic curves for flow rate

Standard flow rate qn [l/min]

Differentialpressure[bar]

Standard flow rate qn [l/min]

Differentialpressure[bar]

LF-M2-G�-C-... LF-M2-G�-C-...

Standard flow rate qn [l/min]

Differentialpressure[bar]

Standard flow rate qn [l/min]

Differentialpressure[bar]

LF-M3-G�-C-...

Standard flow rate qn [l/min]

Differentialpressure[bar]

10.2

Page 27: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Type code

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-26 Festo AG & Co.

Filters LFM-series service units

Function

LF = Compressed air

filter Series

M = Modular

Size

1 = Size 1

2 = Size 2

3 = Size 3

Thread type

G = BSP

Connection size

� = G�

� = G�

� = G�

� = G�

� = G�

Bowls

R = Plastic/manual drain

S = Plastic/automatic drain

T = Metal/manual drain*

with sight glass**

U = Metal/automatic drain*

with sight glass**

Grade of filtration

C = 5 µm

E = 40 µm

* Input pressure max. 17 bar

** Metal bowl M1 without sight glass

L F M— ——

1 2 3 4 5 6 7 8 9 10 11 12 13

10.2

Page 28: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-27Festo AG & Co.

Filters LFM-series service units

1 Mounting bracket HWF-M1 (not

included in scope of delivery)

3 Manual condensate drain,

barbed fitting for plastic tubing

PUN/PAN-6x1

4 Automatic condensate drain,

barbed fitting for plastic tubing

PUN/PAN 8x1.25

5 Installation dimensions

� Flow direction

LF-M1-...

Type B1 B2 B3 B4 B5 B6 B7 B8 D1 D3

D4

D5 L1 L2 L3

ap-

prox.

L4

min.

L5

ap-

prox.

L6 L7

LF-M1-... 40 42.6 21.3 40 2 44 68 10 G� 4 7.2 6.5 102 18.1 15 33 10 35 43.5

G�

2 Mounting bracket HW (not

included in scope of delivery)

4 Manual condensate drain,

barbed fitting for plastic tubing

PUN/PAN 8x1.25

5 Installation dimensions

6 Pipe connector LVR (not included

in scope of delivery)

7 Automatic condensate drain,

thread for connector QSF-�-6-B

with plug connection for plastic

tubing PUN/PAN 6x1

� Flow direction

LF-M2/M3-...

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D3

D4 D5 L1 L2 L3

ap-

prox.

L4

min.

L5

ap-

prox.

L6 L7

LF-M2-... 60 60 30 40 2 69 88 3 128 G� 5.2 G� 7 158 26 29 59 19 41.5 49

G�

G�

LF-M3-... 73 73 36.5 40 2 82 101 3 141 G� 5.2 G� 7 183 26 29 85 19 41.5 493

G�

G�

10.2

Page 29: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-28 Festo AG & Co.

Fine, micro and active carbon filters LFMM-series service units

G� ... G� LFM-M-...-B...

Fine filter 1 µm

with plastic bowl and bowl guard

Many branches of industry frequently

require fine or micro-filtered air:

chemicals, pharmaceuticals, process

technology, food industry, etc. Fine

and micro filters clean compressed

air almost completely of any remain-air almost completely of any remain-

ing minute water and oil droplets, as

well as any dirt particles.

– High-performance filter for techni-

cally oil-free compressed air

LFM-M-...-A...

Micro filter 0.01 µm

with plastic bowl and bowl guard

– Optional 1 µm or 0.01 µm filter

cartridges

– Active carbon filter cartridges pro-

vide odour and oil-free air to food

industry standard

– Air quality to ISO 8573-1, up toLFM-M-...-X...

Active carbon filter

Residual oil content: 0.003 mg/m3,

with plastic bowl and bowl guard

– Air quality to ISO 8573-1, up to

class 1.7.1

– Available with manual condensate

drain or integrated, automatic

condensate drain

– Differential pressure display

(M2/M3 only)

Technical data for fine, micro and active carbon filters

Size M1 M2 M3

Connection G� G� G� G� G� G� G�

Type of mounting In-line installation, mounting bracket;

Combination: flanged

Mounting position Vertical ±5°

Standard nominal flow

rate*

qnN [l/min]

LFM-M-...-BR/BS 140 480 630 700 850 1000 1100

LFM-M-...-AR/AS 80 400 430 480 450 580 600

LFM-M-...-XR 210 680 950 1200 1200 1520 1800

Input pressure range Max. 12 bar

Grade of filtration 1 µm, 0.01 µm

Filter efficiency 99.9999%

Condensate volume 10 ml 53 ml 65 ml

Temperature range –10 ... +60°C (M1: –10 ... +40°C)

Materials Housing: die-cast Zn; protective cover: ABS; plastic bowl: nylon; metal bowl: die-cast Zn; seals: NBR

Weight 0.244 kg 0.600 kg 0.908 kg

* Measured at p1 = 6 bar and �p = 0.07 bar

10.2

Page 30: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-29Festo AG & Co.

Fine, micro and active carbon filters LFMM-series service units

LFM-M1-G�-B-... LFM-M1-G�-A-... Characteristic curves for flow rate

Standard flow rate qn [l/min]

Differentialpressure[bar]

Standard flow rate qn [l/min]

Differentialpressure[bar]

LFM-M1-G�-X-... LFM-M2-G�-B-...

Standard flow rate qn [l/min]

Differentialpressure[bar]

Standard flow rate qn [l/min]

Differentialpressure[bar]

LFM-M2-G�-A-... LFM-M3-G�-X-...

Standard flow rate qn [l/min]

Differentialpressure[bar]

Standard flow rate qn [l/min]

Differentialpressure[bar]

10.2

Page 31: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Type code

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-30 Festo AG & Co.

Fine, micro and active carbon filters LFMM-series service units

Function

LFM = Fine and

micro filters Series

M = Modular

Size

1 = Size 1

2 = Size 2

3 = Size 3

Thread type

G = BSP

Connection size

� = G�

� = G�

� = G�

� = G�

Bowls

R = Plastic/manual drain

S = Plastic/automatic drain

T = Metal/manual drain**

with sight glass***

U = Metal/automatic drain**

with sight glass***

Grade of filtration

A = 0.01µm

B = 1 µm

X = AC*

* Only in connection with bowl types R and T

** Primary pressure max. 17 bar

*** Metal bowl M1 without sight glass

L F M M— —

1 2 3 4 5 6 7

8 9 10 11 12 13 14

10.2

Page 32: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-31Festo AG & Co.

Fine, micro and active carbon filters LFMM-series service units

1 Mounting bracket HWF (not

included in scope of delivery)

3 Manual condensate drain,

barbed fitting for plastic tubing

PUN/PAN-6 x 1

4 Automatic condensate drain,

barbed fitting for plastic tubing

PUN/PAN 8x1.25

5 Installation dimensions

� Flow direction

LFM-M1-...

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1

D3

D4 D5 L1 L2 L3

ap-

prox.

L4

min.

L5

ap-

prox.

L6 L7

LFM-M1-... 40 42.6 21.3 40 2 44 68 10 — G� 4 7.2 6.5 102 18 15 33 10 35 43.5

G�

2 Mounting bracket HW (not

included in scope of delivery)

4 Manual condensate drain,

barbed fitting for plastic tubing

PUN/PAN 8x1.25

5 Installation dimensions

6 Pipe connector LVR (not included

in scope of delivery)

7 Automatic condensate drain,

thread for connector QSF-�-6-B,

with plug connection for plastic

tubing PUN/PAN 6x1

� Flow direction

LFM-M2/M3-...

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D3

D4 D5 L1 L2 L3

ap-

prox.

L4

min.

L5

ap-

prox.

L6 L7

LFM-M2-... 60 60 30 40 2 69 88 3 128 G� 5.2 G� 7 179 48 29 59 19 41.5 49

G�

G�

LFM-M3-... 73 73 36.5 40 2 82 101 3 141 G� 5.2 G� 7 205 48 29 85 19 41.5 493

G�

G�

10.2

Page 33: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-32 Festo AG & Co.

Filter regulators LFRM-series service units

G� ... G� LFR-M-... – Good control characteristics with

low hysteresis and primary pres-

sure compensation

– Available with or without secondary

venting

– Good particle and condensate sep-

aration

– High flow rate and highly efficient in

removing contaminants

– Settings secured via detent on

knob and push-in adjustment lock

– Four pressure ranges: 4, 7, 10 and

16 bar

This device combines a filter and

pressure regulator into one unit. The

sintered filter with water separator

removes dirt, pipe sinter, rust and

condensate from the compressed air.

(16 bar not available in size 1)

– Two pressure gauge connections for

different fitting options

– High flow rate with minimal pres-

sure drop

– Optional 40 µm or 5 µm filter

cartridges

– Available with manual condensate

drain or integrated, automatic

condensate drain

Technical data for filter regulator

Size M1 M2 M3

Connection G� G� G� G� G� G� G� G�

Type of mounting In-line installation, mounting bracket or installation into control panel;

Combination: flanged

Mounting position Vertical ±5°

Standard nominal flow

rate*

qnN [l/min]

LFR-M-...(E10RG/E10SG) 450 2000 3100 5200 4500 5100 4400 3000

LFR-M-...(E07RG/E07SG) 1100 1900 2700 5200 5300 6800 7800 9200

Input pressure range Max. 12 bar (1 ... 17 bar with metal bowl)

Pressure regulation range Max. 10 bar

Grade of filtration 40 µm, 5 µm

Condensate volume 10 ml 53 ml 65 ml

Temperature range –10 ... +60 °C (M1: –10 ... +40 °C)

Materials Housing: die-cast Zn; regulator knob: acetal; plastic bowl: polycarbonate; metal bowl: die-cast Zn; seals:

NBR

Weight 0.37 kg 1 kg 1.5 kg

* Measured at p1 = 10 bar, p2 = 6 bar and �p = 1 bar

10.2

Page 34: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-33Festo AG & Co.

Filter regulators LFRM-series service units

LFR-M1-G�-CO7 LFR-M1-G�-CO7 Characteristic curves for flow rate*

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

LFR-M2-G�-CO7 LFR-M2-G�-CO7

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

LFR-M3-G�-CO7

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

* p1 = 10 bar

10.2

Page 35: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Type code

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-34 Festo AG & Co.

Filter regulators LFRM-series service units

Function

LFR = Compressed

air filter regulator Series

M = Modular

Size

1 = Size 1

2 = Size 2

3 = Size 3

Thread type

G = BSP

Connection size

� = G�

� = G�

� = G�

� = G�

� = G�

Options

G = With pressure gauge

K = Without secondary venting

Bowls

R = Plastic/

manual drain

S = Plastic/

automatic drain

T = Metal/

manual drain**

with sight glass***

U = Metal/

automatic drain**

with sight glass***

Pressure regulation range

04 = 0 ... 4 bar

07 = 0 ... 7 bar

10 = 0 ... 10 bar

16 = 0 ... 16 bar*

Grade of filtration

C = 5 µm

E = 40 µm

* Except size 1 and designs with plastic bowls

** Primary pressure max. 17 bar

*** Metal bowl M1 without sight glass

L F R M— —

1 2 3 4 5 6 7

8 9 10 11 12 13 14 15 16 17 18

10.2

Page 36: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-35Festo AG & Co.

Filter regulators LFRM-series service units

1 Angle bracket HWR (not included

in scope of delivery)

2 Second pressure gauge

connection

3 Manual condensate drain,

barbed fitting for plastic tubing

PUN/PAN-6 x 1

4 Automatic condensate drain,

barbed fitting for plastic tubing

PUN/PAN-8 x 1.5

5 Installation dimensions

� Flow direction

LFR-M1-...

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2

D3

D4

D5 L1 L2 L3

ap-

prox.

L4

min.

L5

ap-

prox.

L6 L7 L8

max.

L9 L10

LFR-M1-... 40 67 21.3 40 2 44 68 8 22 G� 23 4 7.2 7 150 66 15 33 10 44 52.2 3.5 2 2

G�

1 Angle bracket HWR (not included

in scope of delivery)

2 Second pressure gauge

connection

4 Manual condensate drain,

barbed fitting for plastic tubing

PUN/PAN-8 x 1.25

5 Installation dimensions

6 Automatic condensate drain,

thread for connector QSF-�-6-B

with plug connection for plastic

tubing PUN/PAN 6 x 1

� Flow direction

LFR-M2/M3-...

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2

D3

D4 D5 L1 L2 L3

ap-

prox.

L4

min.

L5

ap-

prox.

L6 L7 L8

max.

L9 L10

LFR-M2-... 60 94 30 40 2.7 42 70 8 32 G� 41 5.2 G� 7 224 93 29 59 19 57 66.5 5 3 –

G�

G�

LFR-M3-... 73 108 36.5 49 2.7 47.6 76 8 38.5 G� 41 5.2 G� 7 260 104 29 85 19 57 66.5 5 4 –

G�

G�

10.2

Page 37: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-36 Festo AG & Co.

Lubricators LOEM-series service units

G� ... G� The proportional lubricator adds a

precisely metered quantity of oil to

The following oils are recommended

for Festo units:

the compressed air.

The pressure drop that occurs when

air flows through a Venturi nozzle is

used to convey oil from the container

to the drip cap. From there, the oil

Suitable oils:

Festo special oil

ARAL Vitam GF 32

BP Energol HLP 32to the drip cap. From there, the oil

drips into the air duct directly behind

the proportional valve, where it is ato-

BP Energol HLP 32

Esso Nuto H 32

Mobil DTE 24the proportional valve, where it is ato

mised.

The oil mist ratio is proportional to

h h d

Mobil DTE 24

Shell Tellus Oil DO 32

the flow rate of the compressed air.

– Proportional lubricator with preci

Viscosity range

32 mm2/s

(= cSt) at 40 °C– Proportional lubricator with preci-

sion oil metering

– Reduces wear on highly stressed

(= cSt) at 40 °C

ISO class VG 32 to ISO 3448

– Reduces wear on highly stressed

drive units

– High flow rate

Festo special oil in 1 litre containers

Order code 152 811 OFSW-32g

– Oil top-up even during operation

Technical data for lubricator

Size M1 M2 M3

Connection G� G� G� G� G� G� G� G�

Type of mounting In-line installation, mounting bracket;

Combination: flanged

Mounting position Vertical ±5°

Standard nominal flow

rate*

qnN [l/min]

LOE-M-... 1100 2200 2800 5300 7500 5200 6700 6800

Input pressure range Max. 12 bar

Start of lubrication func-

tion

From 20 l/min From 20 l/min From 25 l/min

Oil filling volume 22.5 ml 99 ml 189 ml

Temperature range –10 ... +60 °C (M1: –10 ... +40 °C)

Materials Housing: die-cast Zn; protective cover: ABS; plastic bowl: nylon; metal bowl: die-cast zinc;

seals: NBR, nylon

Weight (with pressure gauge) 0.594 kg 1.663 kg 2.366 kg

* Measured at p1 = 6 bar and �p = 1 bar

10.2

Page 38: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-37Festo AG & Co.

Lubricators LOEM-series service units

LOE-M1-G�-P-... LOE-M1-G�-P-... Characteristic curves for flow rate

Standard flow rate qn [l/min]

Differentialpressure[bar]

Standard flow rate qn [l/min]

Differentialpressure[bar]

LOE-M2-G�-P-... LOE-M2-G�-P-...

Standard flow rate qn [l/min]

Differentialpressure[bar]

max. perm. qn = 7500 l/min

Standard flow rate qn [l/min]

Differentialpressure[bar]

LOE-M3-G�-P-...

max. perm. qn = 7500 l/min

Standard flow rate qn [l/min]

Differentialpressure[bar]

10.2

Page 39: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Type code

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-38 Festo AG & Co.

Lubricators LOEM-series service units

Function

LOE = Compressed air

lubricator Series

M = Modular

Size

1 = Size 1

2 = Size 2

3 = Size 3

Thread type

G = G thread

Connection size

� = G�

� = G�

� = G�

� = G�

� = G�

Bowls

P = Plastic/without drain

Q = Metal/without drain*

with sight glass**

* Input pressure max. 17 bar

** Metal bowl M1 without sight glass

L O E M— —

1 2 3 4 5 6 7

8 9 10 11 12 13

10.2

Page 40: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-39Festo AG & Co.

Lubricators LOEM-series service units

1 Mounting bracket HWF (not

included in scope of delivery)

2 Installation dimensions

� Flow direction

Metal bowl without sight glass

LOE-M1...

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D5 L1 L2 L4 L6

min.

L7 L8

LOE-M1-... 40 42.6 21.3 40 2 44 68 10 – G� 6.5 134 – 58 35 43.5 46

G�

2 Installation dimensions

3 Pipe connector LVR (not included

in scope of delivery)

4 Mounting bracket HW (not

included in scope of delivery)

� Flow direction

LOE-M2/M3-...

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D5 L1 L2

min.

L4 L6 L7 L8

LOE-M2-... 60 60 30 40 2 69 88 3 128 G� 7 201 23 96 41.5 49 48

G�

G�

LOE-M3-... 73 73 36.5 40 2 82 101 3 141 G� 7 227 23 125 41.5 49 483

G�

G�

10.2

Page 41: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-40 Festo AG & Co.

Service units FRCM-series service units

G� ... G� Service unit

FRC-M-...

– Good particle and condensate

separation

– High flow rate and highly efficient

removal of contaminants

– Settings secured via detent on

knob and push-in adjustment lock

– Four pressure ranges available

– Two pressure gauge connections for

different fitting options

– Option of 40 or 5 µm filter car-

tridges

– Available with manual condensate

drain or integrated, automatic

Service units simplify provision of

filtered, lubricated, compressed air.

The filter cleans the compressed air,

the regulator controls the pressure

and compensates for fluctuations and

the lubricator doses the cleaned air

with a metered oil mist. Filter and lu-

bricator bowls can be easily removed

for cleaning purposes thanks to the

bayonet fitting.

condensate drain

– Secondary lubricator with precision

oil metering

– Oil top-up even during operation

– Filter, regulator and lubricator

functions in a single unit

– Good control characteristics with

low hysteresis and primary pres-

sure compensation

Technical data for service unit

Size M1 M2 M3

Connection G� G� G� G� G� G� G� G�

Type of mounting In-line installation, mounting bracket;

Combination: flanged

Mounting position Vertical ±5°

Standard nominal flow

rate*

qnN [l/min]

FRC-M-...(E10RG/E10SG) 440 440 1000 3500 3700 2800 3000 2800

FRC-M-...(E07RG/E07SG) 540 770 1600 4400 4200 2800 3100 2800

Input pressure range Max. 12 bar

Pressure regulation range Max. 10 bar/max. 7 bar

Oil filling volume 22.5 ml 99 ml 189 ml

Grade of filtration 40 µm, 5 µm

Condensate volume 10 ml 53 ml 65 ml

Temperature range –10 ... +60 °C (M1: –10 ... +40 °C)

Materials Housing: die-cast Zn; plastic bowl: polycarbonate; metal bowl: die-cast Zn; lubricator sight glass:

nylon; seals: NBR

Weight (with pressure gauge) 0.594 kg 1.663 kg 2.366 kg

* Measured at p1 = 10 bar, p2 = 6 bar and �p = 1 bar

10.2

Page 42: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-41Festo AG & Co.

Service units FRCM-series service units

FRC-M1-G�-C10-... FRC-M1-G�-C10-... Characteristic curves for flow rate*

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

FRC-M2-G�-C07-... FRC-M2-G�-C07-...

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

FRC-M2-G�-C07

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

* p1 = 10 bar

10.2

Page 43: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Type code

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-42 Festo AG & Co.

Service units FRCM-series service units

Function

FRC = Compressed air

service unit Series

M = Modular

Size

1 = Size 1

2 = Size 2

3 = Size 3

Thread type

G = G thread

Connection size

� = G�

� = G�

� = G�

� = G�

� = G�

Options

G = With pressure gauge

K = Without secondary venting

Bowls

R = Plastic/

manual drain

S = Plastic/

automatic drain

T = Metal/manual drain**

with sight glass***

U = Metal/

automatic drain**

with sight glass***

Pressure regulation range

04 = 0 ... 4 bar

07 = 0 ... 7 bar

10 = 0 ... 10 bar

16 = 0 ... 16 bar*

Grade of filtration

C = 5 µm

E = 40 µm

* Except size 1 and designs with plastic bowls

** Input pressure max. 17 bar

*** Metal bowl M1 without sight glass

F R C M— —

1 2 3 4 5 6 7

8 9 10 11 12 13 14 15 16 17 18

10.2

Page 44: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-43Festo AG & Co.

Service units FRCM-series service units

1 Mounting bracket LVH (not

included in scope of delivery)

2 Second pressure gauge

connection (G�)

3 Manual condensate drain,

barbed fitting for plastic tubing

PUN/PAN-6 x 1

4 Automatic condensate drain,

barbed fitting for plastic tubing

PUN/PAN 8 x 1.25

5 Installation dimensions

� Flow direction

Metal bowl without sight glass

FRC-M1-...

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2

D3

D4

D5 L1 L2 L3

ap-

prox.

L4

min.

L5

ap-

prox.

L6 L7 L8 L9 L10 L11 L12

min.

L13

FRC- 80 67 21.3 40 40 40 20 2 22 G� 23 4 7.2 5.5 150 66 15 33 10 45 35 46 2 2 134 58 100

M1-... G�

1 Mounting bracket LVH (not

included in scope of delivery)

2 Second pressure gauge

connection (G�)

4 Manual condensate drain,

barbed fitting for plastic tubing

PUN/PAN 8 x 1.25

5 Installation dimensions

6 Automatic condensate drain,

thread for connector QSF-�-6-B

with plug connection for plastic

tubing PUN/PAN-6 x 1

� Flow direction

FRC-M2/M3-...

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2

D3

D4 D5 L1 L2 L3

ap-

prox.

L4

min.

L5

ap-

prox.

L6 L7 L8 L9 L11 L12

min.

L14

FRC- 129 94 30 40 2 64.5 30 3 69 G� 41 5.2 G� 7 224 93 29 59 19 41.5 49 48 3 201 96 23

M2-... G�

G�

FRC- 155 108 36.5 40 2 77.5 36.5 3 82 G� 41 5.2 G� 7 260 104 29 85 19 41.5 49 48 3 227 125 23

M3-... G�

G�

10.2

Page 45: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-44 Festo AG & Co.

Manual on-off valves HEA/HEBM-series service units

G� ... G� On-off valve

manually operated

Flow direction

from left to right

HEA-M-...*

Flow direction

from right to left

HEB-M-...

– 3/2-way manual shut-off valve

– The unit is vented when switched

off

– The switching position is im-

mediately recognisable

– Commercially available padlock

can be used for security

This safety shut-off valve is used to

pressurise and vent pneumatic

systems.

The toggle lever can be held in the

locked position using a conventional

padlock.

M1: Overlap free

*HEA-M-...- is suitable for both flow

directions in size M1.

M1: Overlap free

M2: Not free of overlap

M3: Not free of overlap

HEA-... HEB-...

Air supply from left Air supply from right

Technical data for manual on-off valve

Size M1 M2 M3

Connection G� G� G� G� G� G� G� G�

Type of mounting In-line installation; combination: flanged

Mounting position Any

Standard nominal flow qnN [l/min]

rate* HEA-M-... 1600 3800 4000 8300 7700 7200 10000 9700

HEB-M-... – – 4000 8300 7700 7200 10000 9700

Input pressure range Max. 12 bar

Temperature range –10 ... +80 °C

Materials Housing: die-cast Zn; toggle lever: acetal; seals: NBR and nitrile

Weight (with pressure gauge) 0.337 kg 0.425 kg 0.500 kg

* Measured at p1 = 6 bar and �p = 1 bar

10.2

Page 46: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-45Festo AG & Co.

Manual on-off valves HEA/HEBM-series service units

HEA-M1-G� HEA-M1-G� Characteristic curves for flow rate*

Standard flow rate qn [l/min]

Differentialpressure[bar]

Standard flow rate qn [l/min]

Differentialpressure[bar]

HEA/HEB-M2-G�-... HEA/HEB-M2-G�-...

Standard flow rate qn [l/min]

Differentialpressure[bar]

Standard flow rate qn [l/min]

Differentialpressure[bar]

HEA/HEB-M3-G�

Standard flow rate qn [l/min]

Differentialpressure[bar]

* p1 = 10 bar

10.2

Page 47: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Type code

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-46 Festo AG & Co.

Manual on-off valves HEA/HEBM-series service units

Function

HEA = Manual

on-off valve

(Direction of flow

from left to right)

Series

M = Modular

Size

1 = Size 1

2 = Size 2

3 = Size 3

Thread type

G = G thread

Connection size

� = G�

� = G�

� = G�

� = G�

� = G�

H E A M—

1 2 3 4 5 6 7

8 9 10 11

Function

HEB = Manual

on-off valve

(Direction of flow

from right to left)

Series

M = Modular

Size

2 = Size 2

3 = Size 3

Thread type

G = G thread

Connection size

� = G�

� = G�

� = G�

� = G�

H E B M—

1 2 3 4 5 6 7

8 9 10 11

10.2

Page 48: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-47Festo AG & Co.

Manual on-off valves HEA/HEBM-series service units

Closed Open

1 Mounting bracket HWF (not

included in scope of delivery)

2 Holes for locking with padlock

� Flow direction

HEA-M1-...

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2 D5 L1 L2 L3

ap-

prox.

L4 L5

ap-

prox.

L6 L7

HEA-M1-... 40 42.6 21.3 40 2 44 68 10 – G� 7.4 6.5 61 30.5 26 – 42 35 43.5

G�

Closed OpenHEA-... HEA/HEB-M2/M3-...

HEB-...

2 Holes for locking with padlock

3 Mounting bracket HW (not

included in scope of delivery)

4 Pipe connector LVR (not included

in scope of delivery)

� Flow direction

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2 D5 L1 L2 L3

ap-

prox.

L4 L5

ap-

prox.

L6 L7

HEA-M2-... 49 60 30 40 2 58 77 3 117 G� 8 7 58 26 49 2.5 52 41.5 49

HEB-M2-... G�

G�

HEA-M3-... 58 65 32.5 40 2 67 86 3 126 G� 8 7 58 26 50 2.5 54 41.5 493

HEB-M3-... G�

G�

10.2

Page 49: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-48 Festo AG & Co.

Soft-start valves HEM/HEMSM-series service units

G� ... G� HEM-M-... – Soft-start valve for gradual pres-

with dump function and quick

exhaust

g p

sure build-up

– Drives are moved slowly and safely

to their initial positions

– Sudden and unexpected move-

ments are avoided

– Quick exhausting ensures safety

and time saving during operation

d iThe valve can be combined with

M-series service units.

and service

– Three voltage ranges can be

selectedSoft-start valve (electrical) with sole-

noid coil, without plug socket, with

manual override, dump function and

quick exhaust, free of overlap.

selected

Soft-start valve for gradual pressure

build-up in pneumatic systems.

Pressure is built up gradually. Down-Pressure is built up gradually. Down-

stream cylinders and operating units

HEMS-M-...

without manual override

stream cylinders and operating units

are slowly moved to their initial

positions.

It can be combined with service units

as a safety on-off valve for pneumatic

systems. This safeguards the start-up

of pneumatic systems.

Technical data for soft-start valve with dump function and quick exhaust

Size M2 M3

Connection G� G� G� G� G� G�

Type of mounting In-line installation; combination: flanged

Mounting position Vertical ±5°

Standard nominal flow

rate*

qnN [l/min]

HEM(S)-M-... 2400 3600 3800 3600 3800 3800

Supply

voltage

(HEM(S)-M-...-10 024) 24 V DC

(HEM(S)-M-...-10 110) 110 V AC

(HEM(S)-M-...-10 230) 230 V AC

Input pressure range 2 ... 10 bar (2 to 16 bar)

Protection class (DIN 40 050) IP 65 (with plug socket)

Duty cycle 100%

Temperature range –10 ... +50 °C

Materials Housing: aluminium; sealing plug: nylon; seals: NBR

Weight (with pressure gauge) 1.046 kg 1.471 kg

* Measured at p1 = 6 bar and �p = 1 bar

10.2

Page 50: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-49Festo AG & Co.

Soft-start valves HEM/HEMSM-series service units

HEM-M2-G�-... HEM-M2-G�-... Characteristic curves for flow rate*

Standard flow rate qn [l/min]

Differentialpressure[bar]

Standard flow rate qn [l/min]

Differentialpressure[bar]

HEM-M2-G�-...

Standard flow rate qn [l/min]

Differentialpressure[bar]

p1 = 10 bar

10.2

Page 51: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Type code

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-50 Festo AG & Co.

Soft-start valves HEM/HEMSM-series service units

Function

HEM = Soft-start valve

with dump function and

quick exhaust

Series

M = Modular

Size

2 = Size 2

3 = Size 3

Thread type

G = G thread

Connection size

� = G�

� = G�

� = G�

� = G�

Options

024 = 24 V DC

110 = 110 V AC

230 = 230 V AC

Input pressure range

10 = 2 ... 10 bar

16 = 2 ... 16 bar

H E M M— —

1 2 3 4 5 6 7

8 9 10 11 12 13 14 15 16 17

10.2

Page 52: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-51Festo AG & Co.

Soft-start valves HEM/HEMSM-series service units

Input pressure range 2 ... 10 bar

1 Mounting bracket HW (not

included in scope of delivery)

2 Plug to DIN 43 650 type A

3 Pipe connector LVR (not

included in scope of delivery)

4 Regulating screw for flow

control valve

5 Connecting thread for quick

exhaust

6 Manual override,

resetting

7 Manual override,

by pushing or turning with

detent

� Flow direction

Input pressure range 2 ... 16 bar

Without manual override (type HEMS)

Input pressure range 2 ... 16 bar

HEM-M2/M3-...

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D3 D5 L1 L2 L3 L4 L6 L7

HEM-M2-... 60 60 3.5 40 2 69 88 3 128 G� G� 7 170 77 46 108.5 41.5 49

HEMS-M2-... G�

G�

HEM-M3-... 73 73 3.5 40 2 82 101 3 141 G� G� 7 170 77 46 108.5 41.5 49

HEMS-M3-... G�

G�

10.2

Page 53: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-52 Festo AG & Co.

Soft-start valves HELM-series service units

G� ... G� HEL-M-...

pneumatic

The soft-start valve is installed in a

compressed air system to actively

control pressure build-up during

start-up.

– For remote pneumatic control of

system pressure

– Drives are moved slowly and safely

to their initial positions

– Sudden and unexpected move-

ments are avoided

– For exhausting, input 1 must be

unpressurised

Pressurep

Operating pressure p2 (= p1)

Start signal Gradual pres-

sure build-up

Time t

Switching timedelay

Technical data for soft-start valve

Size M2 M3

Connection G� G� G� G� G� G�

Type of mounting In-line installation; combination: flanged

Mounting position Vertical ±5°

Standard nominal flow qnN [l/min]

rate* HEL-M-... 2400 3600 4500 3600 4500 4500

Input pressure range 2 ... 16 bar

Temperature range –10 ... +80 °C

Materials Housing: aluminium; sealing plug: nylon; seals: NBR

Weight (with pressure gauge) 0.584 kg 0.736 kg

* Measured at p1 = 6 bar and �p = 1 bar

10.2

Page 54: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-53Festo AG & Co.

Soft-start valves HELM-series service units

HEL-M2-G�-... HEL-M2-G�-... Characteristic curves for flow rate*

Standard flow rate qn [l/min]

Differentialpressure[bar]

Standard flow rate qn [l/min]

Differentialpressure[bar]

HEL-M2-G�-...

Standard flow rate qn [l/min]

Differentialpressure[bar]

* p1 = 10 bar

10.2

Page 55: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Type code

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-54 Festo AG & Co.

Soft-start valves HELM-series service units

Function

HEL = Soft-start valve

Series

M = Modular

Size

1 = Size 1

2 = Size 2

Thread type

G = G thread

Connection size

� = G�

� = G�

� = G�

� = G�

Options

000 = Pneumatic

actuation

Pressure range

16 = 2 ... 16 bar

H E L M— —

1 2 3 4 5 6 7

8 9 10 11 12 13 14 15 16 17

10.2

Page 56: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-55Festo AG & Co.

Soft-start valves HELM-series service units

With pneumatic

actuation

HEL-M2/M3-...

1 Mounting bracket type HW-...

(not included in scope of

delivery)

2 Pipe connector LVR (not

included in scope of delivery)

3 Regulating screw for flow

control valve

� Flow direction

Type B1 B2 B4 B5 B6 B7 B8 B9 D1 D5 H1 H2 L1 L2 L6 L7

HEL-M2-... 60 60 40 2 69 88 3 128 G� 7 80 35 72 26.5 41.5 49

G�

G�

HEL-M3-... 73 73 40 2 82 101 3 141 G� 7 80 35 72 26.5 41.5 49

G�

G�

10.2

Page 57: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-56 Festo AG & Co.

Branching modules FRMM-series service units

G� ... G� Branching module

FRM-M-...

– Pneumatic manifold with 4 connec-

tions, attachment facility for auxili-

ary modules

– The pneumatic manifold has an

outlet top and bottom

– Variants: with PE converter fitted

underneath

– Branching module for distribution

of compressed air

– Several additional air connections

for greater flexibility

– Pressure switch can be mounted for

monitoring

– Can be used as intermediate

distributor for varying air qualities

Type codes

Branching module

FRM-...

Function

FRM =

Branching module Series

M = Modular

Size

1 = Size 1

2 = Size 2

3 = Size 3

Thread type

G = BSP

Connection size

� = G�

� = G�

� = G�

Options

Y = PEV-�-B-OD

Z = PEV-�-SC-OD

with display

F R M M— —

1 2 3 4 5 6 7

8 9 10 11 12 13 14

Technical data for branching module

Size M1 M2 M3

Connection G� G� G�

Type of mounting Combination: flanged

Mounting position Any

Standard nominal flow

rate*

qnN [l/min]

FRM-M-... 2800 10 000 21 000

Input pressure Max. 21 bar

Temperature range –10 ... +80 °C

Materials Housing: aluminium

Weight 0.128 kg 0.264 kg 0.439 kg

* Measured at p1 = 6 bar and �p = 1 bar

10.2

Page 58: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-57Festo AG & Co.

Branching modules FRMM-series service units

1 Piping connector with mounting

bracket LVRH-M1 (not included

in scope of delivery)

2 Plug connector to DIN 43 650

5 Pressure switch PEV-�-B-OD

� Flow direction

FRM-M1-...

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 D1 D2 D3 D5 L1 L2 L3 L4 L6 L7 L8 L9 L13

FRM-M1-G� 40 42.6 21.3 40 – 40 56 2 83 2.2 G� G� G� 5.5 36 18 123 5 45 35 – – 100

FRM-M2/M3-...

2 Plug connector to DIN 43 650

3 Mounting bracket HW (not

included in scope of delivery)

4 Piping connector LVR (not

included in scope of delivery)

5 Pressure switch PEV-�-B-OD

6 Double nipple ESK-�-�

� Flow direction

Type B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2 D3 D5 L1 L2 L3 L4 L6 L7 L13

FRM-M2-G� 48 60 30 40 2 57 76 3 116 G� G� G� 7 48 24 140 5 41.5 49 –

FRM-M3-G� 66 73 36.5 40 2 75 94 3 134 G� G� G� 7 48 24 140 6 41.5 49 –

10.2

Page 59: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-58 Festo AG & Co.

Membrane air dryers LDM-series service units

G� Membrane air dryer

for atmospheric dew point –40 °C

LD-M-...-STD

for atmospheric dew point –20 °C

LD-M-...-ECO

– Optimum terminal membrane dryer

– Membrane dryer with high

functional reliability

– Flow rate-dependent dew point

reduction

– Wear-free function without external

energy

Some typical application areas with

higher compressed air drynesshigher compressed air dryness

requirements:

– Drying, cleaning of precision parts

– Purging of measuring glasses,

measuring technology

– Painting systems

Compressed air always contains mois-

ture. A characteristic measure of

moisture content is the dew point.

Many of these increased require-

ments for compressed air quality can

be met by using membrane air dryers.

To ensure operational safety, it is

necessary to pre-filter the compressed

air with an LFM micro filter (0.01 µm).

Technical data for membrane air dryer

Size M3

Connection G�

Type of mounting In-line installation, mounting bracket;

Combination: flanged

Mounting position Vertical ±5°

Standard nominal flow

rate*

qn [l/min] Cartridge size 1 Cartridge size 2 Cartridge size 3 Cartridge size 4

( ) For atmospheric dew pointLD-M3-G�-STD-1/2/3/4 STD 100 (40) 200 (80) 400 (160) 600 (240)

(...) For atmospheric dew point

–40 °C LD-M3-G�-ECO-1/2/3/4 ECO 50 100 200 300

Purge air requirement [l/min] STD 25(10) 50(20) 100(40) 150(60)

(...) For atmospheric dew point

–40 °CECO 8 14 30 34

Atmospheric dew point

with LD-...-STD-1/2/3/4 –20 °C (–40 °C)

with LD-...-ECO-1/2/3/4 –20 °C

Input pressure range 4 ... 10 bar

Temperature range +5 ... +50 °C

Materials Housing: die-cast Zn; metal bowl: aluminium; cartridge: glass fibre; seals: NBR

Weight 1.4 kg 1.6 kg 1.9 kg 2.4 kg

* Measured at p1 = 7 bar and t = 21 °C

10.2

Page 60: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Type code

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-59Festo AG & Co.

Membrane air dryers LDM-series service units

Function

LD = Membrane

air dryer Series

M = Modular

Size

3 = Size 3

Thread type

G = G thread

N = NPT thread

Connection size

� = G�

Options

1 = Cartridge size 1

2 = Cartridge size 2

3 = Cartridge size 3

4 = Cartridge size 4

Atmospheric dew point

STD = Standard –40 °C

ECO = Economy –20 °C

L D M— ——

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

3 1 2

10.2

Page 61: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-60 Festo AG & Co.

Membrane air dryersM-series service units

LD-M-...

1 Mounting bracket HW (not

included in scope of delivery)

2 Pipe connector LVR (not included

in scope of delivery)

� Flow direction

Type B1 B2 L1

LD-M3-G�-...-1 60 37 193

LD-M3-G�-...-2 60 37 263

LD-M3-G�-...-3 74 44 303

LD-M3-G�-...-4 74 44 373

10.2

Page 62: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-61Festo AG & Co.

Service unit combinations LFR/FRCM-series service units

A service unit combination consists of

various individual modules.

Festo M-series service units can be

combined in a modular system by the

user to create a service unit combina-

tion that meets the on-site require-

ments.

Common application examples are

catered for with fully assembled ser-

vice unit combinations. Available with

manual condensate drain or inte-

grated, automatic condensate drain.

-H- Note:

All M-series combinations are fitted

with plastic bowls, including bowl

guards. They also have a regulating

range (p2 = 10 bar) and are fitted

with 40 µm filter cartridges.

Input pressure range Max. 12 bar (p1) LFR-M...-KA, LFR-M...-KB,

LFR-M -KC LFR-M -KEOperating pressure range Max. 10 bar (p2)

LFR-M...-KC, LFR-M...-KE,

LFR-M-...-KF

Temperature range –10 ... +60°C (M1: –10 ... +40°C) FRC-M...-KA, FRC-M...-KB,

FRC-M...-KC

Input pressure range Max. 12 bar (p1) LFR-M...-KD, LFR-M...-KG

FRC-M-...-KE, FRC-M-...-KF

Operating pressure range 2 ... 10 bar

Temperature range –10 ... +50°C

10.2

Page 63: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-62 Festo AG & Co.

Service unit combinations LFR/FRCM-series service units

Individual units

1 Pipe connector LRV-M

2 Manual on-off valve HEA-M

3 Filter regulator LFR-M

4 Mounting bracket HW-M

5 Connector LV-M

6 Branching module FRM-M

7 Lubricator LOE-M

8 Pressure regulator LR-M

9 Soft-start valve HEM-M

aJ Pressure switch PEV and double

nipple ESK-�-�

1

2

3

4

5

6

8

7

69

aJ

10.2

Page 64: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-63Festo AG & Co.

Service unit combinations LFRM-series service units

LFR-M-...-KA

Size Connec-

tion

Standard

nominal flow

rate*

[l/min]

M1 G� 750

M2 G� 1750

G� 3900

M3 G� 4000

* Measured at p1 = 10 bar, p2 = 6 bar

and �p = 1 bar

Type B1 B10 D1 H1 H2 H3 L1 L2 L5

min.

T1 T2

LFR-M1-...-KA 86 40 5.5 100 35 45 165 66 33 41 87

LFR-M2-...-KA 124 64.5 7 98 41.3 41.3 253 93 59 41 105

LFR-M3-...-KA 158 77.5 7 98 41.3 41.3 289 104 85 48 120

LFR-M-...-KB

Size Connec-

tion

Standard

nominal flow

rate*

[l/min]

M1 G� 750

M2 G� 1800

G� 3800

M3 G� 3800

* Measured at p1 = 10 bar, p2 = 6 bar

and �p = 1 bar

Type B2 B11 B12 D1 H1 H2 H3 L1 L2 L5

min.

T1 T2

LFR-M1-...-KB 126 40 40 5.5 100 35 45 165 66 33 41 87

LFR-M2-...-KB 182 53.5 69 7 98 41.3 41.3 253 93 59 41 105

LFR-M3-...-KB 225 62.5 82 7 98 41.3 41.3 289 104 85 48 120

10.2

Page 65: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-64 Festo AG & Co.

Service unit combinations LFRM-series service units

LFR-M-...-KC

Size Connec-

tion

Standard

nominal flow

rate*

[l/min]

M1 G� 670

M2 G� 1600

G� 4000

M3 G� 4000

* Measured at p1 = 10 bar, p2 = 6 bar

and �p = 1 bar

Type B3 B11 D1 H1 H2 H3 L1 L2 L5

min.

T1 T2

LFR-M1-...-KC 80 40 5.5 100 35 45 165 66 33 41 87

LFR-M2-...-KC 118 53.5 7 98 41.3 41.3 253 93 59 41 105

LFR-M3-...-KC 140 62.5 7 98 41.3 41.3 289 104 85 48 120

LFR-M-...-KD

Size Connec-

tion

Standard

nominal flow

rate*

[l/min]

M2 G� 1300

G� 1800

M3 G� 2000

* Measured at p1 = 10 bar, p2 = 6 bar

and �p = 1 bar

Type B4 B10 D1 H1 H2 H3 L1 L2 L5

min.

L8 T1 T2

LFR-M2-...-KD 149 64.5 7 98 41.3 41.3 253 93 59 150 41 105

LFR-M3-...-KD 185 77.5 7 98 41.3 41.3 289 104 85 150 48 120

10.2

Page 66: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-65Festo AG & Co.

Service unit combinations LFRM-series service units

LFR-M-...-KE

Size Connec-

tion

Standard

nominal flow

rate*

[l/min]

M1 G� 750

M2 G� 1750

G� 3900

M3 G� 4000

* Measured at p1 = 10 bar, p2 = 6 bar

and �p = 1 bar

Type B1 B10 D1 H1 H2 H3 L1 L2 L5

min.

T1 T2 T3

LFR-M1-...-KE 86 40 5.5 100 35 45 165 66 33 41 87 106

LFR-M2-...-KE 124 64.5 7 98 41.3 41.3 253 93 59 41 105 106

LFR-M3-...-KE 158 77.5 7 98 41.3 41.3 289 104 85 48 120 113

LFR-M-...-KF

Size Connec-

tion

Standard

nominal flow

rate*

[l/min]

M1 G� 750

M2 G� 1800

G� 3800

M3 G� 3800

* Measured at p1 = 10 bar, p2 = 6 bar

and �p = 1 bar

Type B2 B11 B12 D1 H1 H2 H3 L1 L2 L5

min.

T1 T2 T3

LFR-M1-...-KF 126 40 40 5.5 100 35 45 165 66 33 41 87 106

LFR-M2-...-KF 182 53.5 69 7 98 41.3 41.3 253 93 59 41 105 106

LFR-M3-...-KF 225 62.5 82 7 98 41.3 41.3 289 104 85 48 120 113

10.2

Page 67: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-66 Festo AG & Co.

Service unit combinations LFRM-series service units

LFR-M-...-KG

Size Connec-

tion

Standard

nominal flow

rate*

[l/min]

M2 G� 1300

G� 1800

M3 G� 1800

* Measured at p1 = 10 bar, p2 = 6 bar

and �p = 1 bar

Type B7 B11 B13 D1 H1 H2 H3 L3 L4 L5

min.

L8 T1 T2 T3

LFR-M2-...-KG 251 53.5 126 7 98 41.3 41.3 284 124 59 150 41 105 106

LFR-M3-...-KG 307 62.5 157 7 98 41.3 41.3 309 124 85 150 48 120 113

10.2

Page 68: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-67Festo AG & Co.

Service unit combinations FRCM-series service units

FRC-M-...-KA

Size Connec-

tion

Standard

nominal flow

rate*

[l/min]

M1 G� 400

M2 G� 1400

G� 2900

M3 G� 3200

* Measured at p1 = 10 bar, p2 = 6 bar

and �p = 1 bar

Type B6 B10 B15 D1 H1 H2 H3 L1 L2 L5

min.

L6

min.

L7 T1 T2

FRC-M1-...-KA 120 40 40 5.5 100 35 45 165 66 33 58 88 41 87

FRC-M2-...-KA 186 64.5 57 7 98 41.3 41.3 253 93 59 96 153 41 105

FRC-M3-...-KA 230 77.5 75 7 98 41.3 41.3 289 85 85 125 179 48 120

FRC-M-...-KB

Size Connec-

tion

Standard

nominal flow

rate*

[l/min]

M1 G� 400

M2 G� 1400

G� 2900

M3 G� 3200

* Measured at p1 = 10 bar, p2 = 6 bar

and �p = 1 bar

Type B6 B10 B15 D1 H1 H2 H3 L1 L2 L5

min.

L6

min.

L7 T1 T2 T2

FRC-M1-...-KB 120 40 40 5.5 100 35 45 165 66 33 58 88 41 87 106

FRC-M2-...-KB 186 64.5 57 7 98 41.3 41.3 253 93 59 96 153 41 105 106

FRC-M3-...-KB 230 77.5 75 7 98 41.3 41.3 289 104 85 125 179 48 120 113

10.2

Page 69: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-68 Festo AG & Co.

Service unit combinations FRCM-series service units

FRC-M-...-KC

Size Connec-

tion

Standard

nominal flow

rate*

[l/min]

M1 G� 400

M2 G� 1400

G� 3000

M3 G� 3200

* Measured at p1 = 10 bar, p2 = 6 bar

and �p = 1 bar

Type B7 B11 B13 D1 H1 H2 H3 L1 L2 L5

min.

L6

min.

L7 T1 T2 T3

FRC-M1-...-KC 160 40 80 5.5 100 35 45 165 66 33 58 88 41 87 106

FRC-M2-...-KC 244 53.3 126 7 98 41.3 41.3 253 93 59 96 153 41 105 106

FRC-M3-...-KC 297 62.5 157 7 98 41.3 41.3 289 104 85 125 179 48 120 113

FRC-M-...-KE

Size Connec-

tion

Standard

nominal flow

rate*

[l/min]

M2 G� 1000

G� 1500

M3 G� 1700

* Measured at p1 = 10 bar, p2 = 6 bar

and �p = 1 bar

Type B8 B10 B12 D1 H1 H2 H3 L3 L4 L5

min.

L6

min.

L7 L8 T1 T2

FRC-M2-...-KE 218 64.5 69 7 98 41.3 41.3 284 124 59 96 153 150 41 105

FRC-M3-...-KE 250.5 77.5 82 7 98 41.3 41.3 309 124 85 125 179 150 48 120

10.2

Page 70: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Dimensions

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-69Festo AG & Co.

Service unit combinations FRCM-series service units

FRC-M-...-KF

Size Connec-

tion

Standard

nominal flow

rate*

[l/min]

M2 G� 1000

G� 1600

M3 G� 1800

* Measured at p1 = 10 bar, p2 = 6 bar

and �p = 1 bar

Type B9 B11 B14 D1 H1 H2 H3 L3 L4 L5

min.

L6

min.

L7 L8 T1 T2 T3

FRC-M2-...-KF 340 53.5 207 7 98 41.3 41.3 284 124 59 96 153 150 41 105 106

FRC-M3-...-KF 403 62.5 246 7 98 41.3 41.3 309 124 85 125 179 150 48 120 113

10.2

Page 71: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-70 Festo AG & Co.

Service unit combinations LFRM-series service units

Characteristic curves for flow rate* LFR-M2-G�-KA-... LFR-M2-G�-KB-...

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

LFR-M2-G�-KC-... LFR-M2-G�-KD-...

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

LFR-M2-G�-KE-... LFR-M2-G�-KF-...

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

LFR-M2-G�-KG-...

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

* p1 = 10 bar

10.2

Page 72: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Technical data

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-71Festo AG & Co.

Service unit combinations FRCM-series service units

FRC-M2-G�-KA-... FRC-M2-G�-KB-... Characteristic curves for flow rate*

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

FRC-M2-G�-KC-... FRC-M2-G�-KE-...

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

FRC-M2-G�-KF-...

Standard flow rate qn [l/min]

Outputpressurep2

[bar]

* p1 = 10 bar

10.2

Page 73: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Mounting accessories

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-72 Festo AG & Co.

Service unit accessoriesM-series service units

Mounting bracketg

HWF-...

(holder for individual units

with bowls)

Part No. Type For function unit/type Size For connection

183 865 HWF-M1 LF, LFM, LOE, LFR M1 G�, G�

Angle bracket HWR-M1 HWR-M2/M3g

HWR-...

(holder for

pressure regulator)

Part No. Type For function unit/type Size For connection

183 868 HWR-M1 LR, LRB, LFR M1 G�, G�

183 869 HWR-M2 M2 G�, G�, G�

183 870 HWR-M3 LR, LFR M3 G�, G�, G�

Mounting bracket

HW-...

(universal bracket on connector LV-...)

Part No. Type For function unit/type Size For connection

183 871 HW-M2/M3 All function units M2, M3 G�, G�, G�, G�

10.2

Page 74: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Mounting accessories

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-73Festo AG & Co.

Service unit accessoriesM-series service units

LV-... LVH-M1 LVH-M2/M3 Connector

LV-...

Connector with mounting bracket

LVH-...

Part No. Type For function unit/type Size For connection

183 872 LV-M1 All function units M1 G�, G�

183 873 LV-M2/M3 M2, M3 G�, G�, G�, G�

183 874 LVH-M1 All function units M1 G�, G�

183 875 LVH-M2/M3 M2, M3 G�, G�, G�, G�

LVR-M1 LVRH-... Piping connector for fixed pipingp g p p g

(2 pieces)

LVR-...

Piping connector with mounting

bracket

LVRH-...

Part No. Type For function unit/type Size For connection

183 876 LVR-M1-G�-SET All function units M1 G�

183 877 LVR-M1-G�-SET G�

183 878 LVR-M1-G�-SET G�

183 890 LVRH-M1-G�-SET All function units M1 G�

183 891 LVRH-M1-G�-SET G�

183 892 LVRH-M1-G�-SET G�

LVR-M2/M3 Piping connector for fixed pipingp g p p g

LVR-...

Part No. Type For function unit/type Size For connection

183 882 LVR-M2/M3-G� All function units M2, M3 G�

183 883 LVR-M2/M3-G� G�

183 884 LVR-M2/M3-G� G�

183 885 LVR-M2/M3-G� G�

10.2

Page 75: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Mounting accessories

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-74 Festo AG & Co.

Service unit accessoriesM-series service units

Pressure gauge

MA-...

Part No. Type For function unit/type Size For display range

183 896 MA-23-6-R� LR, LFR, FRC M1 0 ... 6 bar

183 897 MA-23-10-R�

, ,

0 ... 10 bar

183 898 MA-23-16-R� 0 ... 16 bar

183 899 MA-40-6-G�-EN* LR, LFR, FRC (per EN 837-1) M2, M3 0 ... 6 bar

183 900 MA-40-10-G�-EN*

, , (p 37 ) , 3

0 ... 10 bar

183 901 MA-40-16-G�-EN* 0 ... 16 bar

183 902 MA-40-25-G�-EN* 0 ... 25 bar

187 078 MA-40-6-R�-EN* Specially designed for LRB with M1, M2 0 ... 6 bar

187 079 MA-40-10-R�-EN*

p y g

coated R thread (per EN 837/1)

,

0 ... 10 bar

187 080 MA-40-16-R�-EN*

(p / )

0 ... 16 bar

187 081 MA-40-25-R�-EN* 0 ... 25 bar

* Per EN 837-1

Sturdy mounting ring

HMR-...

made of aluminium for control panel

installation of regulators

Part No. Type For function unit/type Size For connection

183 925 HMR-M1-ALU LR, LRB M1 G�, G�

183 926 HMR-M2-ALU

,

M2 G�, G�, G�

183 927 HMR-M3-ALU LR M3 G�, G�, G�

Regulator adjustment lock

(for LR, LRB, LFR, FRC)

LRVS-...

The regulator adjustment lock is fitted

under the regulator head (regulator

head must be removed). When the

LRVS is installed, the set pressure

cannot be changed.

Part No. Type For function unit/type Size For connection

183 928 LRVS-M1 LR, LRB, FR, FRC M1 G�, G�

183 929 LRVS-M2

, , ,

M2 G�, G�, G�

183 930 LRVS-M3 LR, LFR, FRC M3 G�, G�, G�

10.2

Page 76: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Mounting accessories

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-75Festo AG & Co.

Service unit accessoriesM-series service units

Lubricator protective cover

LOEVS-...

Part No. Type For function unit/type Size For connection

183 931 LOEVS-M1/M2/M3 LOE M1, M2, M3 G�, G�, G�, G�, G�

1 µm, 0.01 µm5 µm, 40 µm

LFM...LFP... LFMPX...

0.003 mg/m3

Filter cartridge

LFP...

LFM...

Part No. Type For function unit/type Size Grade of filtration

183 910 LFPC-M1 LF M1 5 µm

183 911 LFPC-M2 M2

183 912 LFPC-M3 M3

183 913 LFPE-M1 LF M1 40 µm

183 914 LFPE-M2 M2

183 915 LFPE-M3 M3

183 916 LFMPB-M1 LFM M1 1 µm

183 917 LFMPB-M2 M2

183 918 LFMPB-M3 M3

183 919 LFMPA-M1 LFM M1 0,01 µm

183 920 LFMPA-M2 M2

183 921 LFMPA-M3 M3

183 922 LFMPX-M1 LFM M1 Active carbon 0.003 mg/m3

183 923 LFMPX-M2 M2 max. residual oil content

183 924 LFMPX-M3 M3

10.2

Page 77: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Mounting accessories

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-76 Festo AG & Co.

Service unit accessoriesM-series service units

HWF-M1

(for LF, LFM, LOE, LFR)

HWR-M1

(for LR, LRB, LFR)

HWR-M2/M3

(for LR, LRB, LFR)

Type B1 B2 B4 B5 B6 B7 B8 D5 L6 L7

HWR-M2 28 18.5 40 2.7 42.0 70 8 7 57 66.5

HWR-M3

5

49

7

47.6 76

7 57 5

HW-M2/M3

10.2

Page 78: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Mounting accessories

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-77Festo AG & Co.

Service unit accessoriesM-series service units

LV-M1

(for all types)

LV-M2/M3

LVH-M1

(for all types)

LVH-M2/M3

Type B9

LVH-M2 69

LVH-M3 82

10.2

Page 79: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Mounting accessories

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-78 Festo AG & Co.

Service unit accessoriesM-series service units

LVR-M1

Type D1

LVR-M1-G�-SET G�

LVR-M1-G�-SET G�

LVR-M1-G�-SET G�

LVR-M2/M3

Type B1 B2 D1

LVR-M2 128 90.4 G�9

G�

G�

G�

LVR-M3 141 103.4 G�3 3

G�

G�

G�

10.2

Page 80: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Mounting accessories

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-79Festo AG & Co.

Service unit accessoriesM-series service units

LVRH-M1

Type D1

LVR-M1-G�-SET G�

LVR-M1-G�-SET G�

LVR-M1-G�-SET G�

LVRH-M1-G�-SET G�

LVRH-M1-G�-SET G�

LVRH-M1-G�-SET G�

MA-23-...

for LFR-M1, LR-M1, FRC-M1

MA-40-...-G����-EN

for LFR-M2/M3, LR-M2/M3, FRC-

M2/M3

MA-40-...-R����-EN

for LRB-M1/M2

10.2

Page 81: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Mounting accessories

Products 2001 – Subject to change – 01/04Vol.3 / 10.2-80 Festo AG & Co.

Service unit accessoriesM-series service units

Pressure switch

PEV ����-B-0D

Adjustable pressure switching point

and hysteresis, without plug socket

Order code

175 250 PEV�-B-0D

Pressure switch

PEV ����-SC-0D

Adjustable pressure switching point

Hysteresis is finely adjustable with

visual scale, without plug socket

Order code

161 760 PEV�-SC-0D

Double nipple

ESK-...

Adjustable for angular compensation

Order code

151 521 ESK-�-�

Electronic pressure sensor

SDE1

For pressure monitoring on D or M series

service units

Order code

192 026 SDE-D10-G2-R18-C-P1-M8

192 027 SDE-D10-G2-R18-C-P2-M8

192 028 SDE-D10-G2-R14-C-P1-M8

192 029 SDE-D10-G2-R14-C-P2-M8

10.2

Page 82: -V-€¦ · M2 G Operatingpressure12 bar Pressureregulationrange10 bar G Directproportionallubricator Gradeoffiltration40 µm Gradeoffiltration5 µm G With pressuregauge Manualcondensatedrain

Mounting accessories

01/04 – Subject to change – Product 2001 Vol.3 / 10.2-81Festo AG & Co.

Service unit accessoriesM-series service units

Plug socket

MSSD-...

for PEV-�-...

Order code

171 157 MSSD-C-4P

Plug socket

PEV-...

with integrated LED

Order code

164 274 PEV-�-WD-LED-24

164 275 PEV-�-WD-LED-230

10.2