valero image paint program - jones-blair … image paint program revised november, 2006 ... sspc-sp2...

27
CORPORATE SERVICE STATION PAINTING SPECIFICATIONS VALERO IMAGE PAINT PROGRAM Revised November, 2006 MAINTENANCE / RENOVATIONS / NEW CONSTRUCTION - PRIMERS, URETHANES & ACRYLIC COATINGS - WOOD SEALERS AND STAINS - CONCRETE STAIN FOR ADA RAMPS - PARKING LOT STRIPING FOR CONCRETE AND ASPHALT SURFACES - CAR WASH - INTERIOR FINISHES NOTE: ALL PRODUCTS LISTED ARE APPROVED FOR ALL AREAS EXCEPT FOR THE SPECIFIC PRIMER AND URETHANE AND WOOD STAINS APPROVED FOR CALIFORNIA ALL SPECIFICATION ARE TO BE USED IN CONJUNCTIONS WITH PLANS PROVIDED FOR RENOVATIONS AND NEW CONSTRUCTION JONES-BLAIR PAINTS ARE THE APPROVED PAINTS FOR THIS PROGRAM. NO SUBSTITUTIONS WILL BE ALLOWED WITHOUT WRITTEN APPROVAL FROM THE DIRECTOR OF CONSTRUCTION

Upload: dotu

Post on 15-Mar-2018

275 views

Category:

Documents


3 download

TRANSCRIPT

CORPORATE SERVICE STATION

PAINTING SPECIFICATIONS

VALERO IMAGE PAINT PROGRAM

Revised November, 2006

MAINTENANCE / RENOVATIONS / NEW CONSTRUCTION - PRIMERS, URETHANES & ACRYLIC COATINGS - WOOD SEALERS AND STAINS - CONCRETE STAIN FOR ADA RAMPS - PARKING LOT STRIPING FOR CONCRETE AND ASPHALT SURFACES - CAR WASH - INTERIOR FINISHES NOTE: ALL PRODUCTS LISTED ARE APPROVED FOR ALL AREAS EXCEPT FOR THE SPECIFIC PRIMER AND URETHANE AND WOOD STAINS APPROVED FOR CALIFORNIA ALL SPECIFICATION ARE TO BE USED IN CONJUNCTIONS WITH PLANS PROVIDED FOR RENOVATIONS AND NEW CONSTRUCTION JONES-BLAIR PAINTS ARE THE APPROVED PAINTS FOR THIS PROGRAM. NO SUBSTITUTIONS WILL BE ALLOWED WITHOUT WRITTEN APPROVAL FROM THE DIRECTOR OF CONSTRUCTION

2

Revision Date:

(November, 2006) CONTENTS

ITEM PAGE 2.1 BUILDING EXTERIOR 2.1.1 CMU / EIFS / METAL Textured FASCIA…………………………. 5 PVC Accent Bands on Marquee 2.1.2 Steel Building Form (if applicable)……………………………………… 6 2.1.3 Steel Dispenser Island Forms……………………………………………. 6

2.1.4 Steel light pole , steel bases and concrete bases…………………………. 6 Existing painted poles and steel bases

2.1.5 Dumpster Enclosure… new and existing .…………………………….... 7 2.1.6 Canopy Columns…………………………………………………………. 7

2.1.7 Canopy Fascia …………………………………………………………... 8 2.1.8 Canopy Deck / Building Soffits …………………………………………. 8

2.1.9 ID / Price Sign Poles …………………………………………………….. 9 2.1.10 Pipe Bollards …………………………………………………………….. 9 2.1.11 Hand Rails ……………………………………………………………….. 9 2.1.12 Building Flashing / Standing Seam …………………………………….. 10 2.1.13 Electrical Panels – Exterior …………………………………………….. 10 2.1.14 H.V.A.C. Housing, Compressor Housing ………………………………... 10 2.1.15 Equipment Screens ………………………………………………………. 11 2.1.16 Fuel Vents and brackets ………………………………………………… 11 2.1.17 Street Boxes / Manhole Covers ………………………………………….. 11

3

2.2 BUILDING INTERIOR 2.2.1 CMU – all areas ………………………………………………………….. 12 2.2.2 Drywall – all areas ……………………………………………………….. 12 2.2.3 Door and frames – interior …………………………………………….. 13 2.2.4 Store front frame and Entry Doors ……………………………………. 15 2.2.5 Exposed surfaces of walk-in coolers ………………………………….. 13 2.2.6 Restroom Interior ………………………………………………………... 14 2.2.7 Painting over ceramic wall tile ……………………………………….. 14 2.3 CARWASH – Exterior 2.3.1 Building Fascia …………………………………………………………. 14 2.3.2 Pipe bollards – Exterior and interior ………………………………….. 14 2.3.3 Electrical Panels – Exterior …………………………………………….. 15 2.3.4 Mechanical Rooms, Door / frame / Header ……………………………... 15 2.3.5 Storerooms, Door / Frame / Header ……………………………………. 15 2.3.6 Restrooms, Door / Frame / Header ……………………………………… 16 2.3.7 Bay Door / Frame /Header ………………………………………………. 16 2.3.8 Exterior Fan Covers …………………………………………………….. 16

4

2.4 CARWASH – Interior 2.4.1 Restroom CMU …………………………………………………………… 16 2.4.2 BAY CMU -- OPTIONAL FINISHES …………………………………. 17 OPTION 1 – Painting existing Car Wash Buildings without

removing the existing carwash equipment. OPTION 2 -- Fiberglass Panels for existing Car Wash Buildings To be used when replacing existing car wash equipment. OPTION 3 -- Fiberglass coating for new Car Wash Buildings For New To Industry Sites.

2.4.3 Bay Conduits / J-boxes …………………………………………………. 18 2.4.4 Roof Downspout and wall Hangers …………………………………….. 18 2.4.5 Paving striping and Ramp Stains ………………………………………. 18 2.4.6 Wood Trellis …………………………………………………………….. 19 2.4.7 Exterior Ice Merchandiser ……………………………………………… 19

5

2.0 COATINGS SPECIFICATIONS 2.1 BUILDING EXTERIOR 2.1.1 CMU / EIFS / METAL Textured FASCIA PVC Accent Bands on Marquee Surface Preparation: Remove all loose mortar by rubbing surface with masonry block or scrape with 6” to 8” floor scraper to remove any mortar fins or protrusions. Remove all loose foreign matter with a stiff broom and coat before contamination occurs. CMU refers to Split face and fluted block. Primer: Jones-Blair #3781 Acrylic Latex Block Filler, @ 10.0-18.0 mils dft/to fill completely.

Top coat: For Metal textured Fascia Jones-Blair Acrylithane C-HS Acrylic Urethane Topcoat.

Two coats required applied at 1.5-2.0 mils dft per coat. Color: JB #4460-032 Valero Gray Top coat: For Brick Veneer

Jones-Blair Primer #3090 Multi-Grip 2 Acrylic Primer. Top coat with Jones-Blair # 4410-038 Valero Sand Acrylithane C-HS Acrylic Urethane. Two coats required.

Color: JB #4410-038 Valero Sand Top coats: For Reveals / Stars ( IF APPLICABLE )

Jones-Blair Acrylithane C-HS #4400-000 White Acrylic Urethane. Two coats required.

Color: JB #4400-000 Valero White EFIS : Walls and Fascia Surface Prep: Must be clean, dry and in sound condition.

6

Primer: Jones-Blair #3091 Gray Multi-Grip 2 Acrylic Latex Primer. Top Coats: Jones-Blair #4410-038 Valero Sand. Two coats required. Color: JB #4410-038 Valero Sand PVC Accent Bands on Marquee ( IF APPLICABLE ) Surface Prep: Must be light sanded, clean and dry Primer: Jones-Blair #15077 White Multi Purpose alkyd. Top coats: Jones-Blair Acrylithane C-HS #4430-000 Teal Acrylic Urethane. 2 coats required. Color: JB #4430-000 Valero Teal 2.1.2 Steel Building Form ( IF APPLICABLE )

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15632 Gray Multi-Purpose Alkyd Primer.

Top Coats: Jones-Blair #4460-032 Valero Gray. Acrylithane C-HS Acrylic Urethane. Two coats required. Color: JB #4460-032 Valero Gray APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primers: Jones-Blair #3090 White or 3091 Gray Multi-Grip 2 Acrylic as noted for brick, masonry, stone, EFIS, or Stucco. Where Epoxy Urethane Primer is required ie, factory finished surfaces or other baked enamel finishes and field applied Polyurethane finishes: Jones-Blair #33010/99951 Ureprime White Epoxy Urethane applied at 1.5-2.0 mils dft. Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

2.1.3 Steel Dispenser Island Forms

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair Multi Purpose #15632 Gray Alkyd (In CA. use #3091 Multi-Grip 2 Gray Acrylic Primer)

Top Coats: Jones-Blair Acrylithane C-HS #4460-032 Valero Gray Urethane. Two Coats Required. Color: JB#4460-032 Valero Gray

7

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primers: Jones-Blair #3090 White or 3091 Gray Multi-Grip 2 Acrylic as noted for brick, masonry, stone, EFIS, or Stucco. Where Epoxy Urethane Primer is required ie, factory finished surfaces or other baked enamel finishes and field applied Polyurethane finishes: Jones-Blair #33010/99951 Ureprime White Epoxy Urethane applied at 1.5-2.0 mils dft. Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

2.1.4 Steel Light Poles / steel Bases / concrete bases

Existing painted poles and steel bases

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15632 Gray Multi-Purpose Alkyd Primer.

Top Coats: Jones-Blair #4460-032 Valero Gray Acrylithane C-HS Acrylic Urethane. Two coats required. Color: JB #4460-032 Valero Gray

Primers: Jones-Blair #3090 White or 3091 Gray Multi-Grip 2 Acrylic as noted for brick, masonry, stone, EFIS, or Stucco. Where Epoxy Urethane Primer is required ie, factory finished surfaces or other baked enamel finishes and field applied Polyurethane finishes: Jones-Blair #33010/99951 Ureprime White Epoxy Urethane applied at 1.5-2.0 mils dft. Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

New and existing Bronze steel light poles and fixtures….ARE NOT TO BE PAINTED

8

These will be shipped from the factory with a Bronze color. CONCRETE BASES … are NOT TO BE PAINTED Sandblast and remove paint from existing concrete bases 2.1.5 Dumpster Enclosure … new and existing

- METAL Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15632 Gray Multi-Purpose Alkyd Primer.

Top Coats: Jones-Blair #4460-032 Valero Gray Acrylithane C-HS Acrylic Urethane. Two coats required. Color: JB #4460-032 Valero Gray

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA Primers: Jones-Blair #3090 White or 3091 Gray Multi-Grip 2 Acrylic as noted for brick, masonry, stone, EFIS, or Stucco. Where Epoxy Urethane Primer is required ie, factory finished surfaces or other baked enamel finishes and field applied Polyurethane finishes: Jones-Blair #33010/99951 Ureprime White Epoxy Urethane applied at 1.5-2.0 mils dft. Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

- WOOD… CEDAR . . new and existing Surface Prep: Remove dirt and sand rough surfaces. Finish coat: Jones-Blair Ranchero Acrylic Cover Coat to match color Cedar. APPROVED STAIN FOR CALIFORNIA Jones-Blair Ranchero Acrylic Cover Coat to match color Cedar. - CMU .. new and existing.. SEE 2.1.1 2.1.6 Canopy Columns STEEL

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15077 White Multi-Purpose Alkyd Primer.

9

Top Coats: Jones-Blair #4400-037 Valero Tan Acrylithane C-HS Acrylic Urethane. Two coats required. Color: JB #4400-037 Valero Tan CONCRETE Surface Prep: Power wash to remove contaminants. (If slick, etch with a 10% solution of muriatic acid and water then rinse with clean water and allow to dry thoroughly before priming.)

Primer: Jones-Blair #3090 White Multi-Grip 2 Acrylic. One coat applied at 1.5-2.0 mils dft.

Top Coats: Jones-Blair #4400-037 Valero Tan Acrylithane C-HS Acrylic Urethane. Two coats required. Color: JB #4400-037 Valero Tan 2.1.7 Canopy Fascia (Maintenance only – otherwise vinyl if indicated)

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Repairs Patch existing holes in fascia. After cleaning and sanding, fill

holes with Bondo metal filler. Sand holes level with deck surface. clean area and lightly sand before priming.

Primer: Jones-Blair #33010/99951 White Epoxy Urethane Primer if factory finished or coated with two component urethane.

Top Coat: Jones-Blair Acrylithane C-HS #4430-000 Teal Acrylic Urethane. 2 coats required. Color: JB #4430-000 Valero Teal APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primer: Jones-Blair #33010-CA/99951 White Epoxy Urethane Primer if factory finished or coated with two component urethane. Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

10

2.1.8 Canopy Deck / Building soffits

Wood / stucco decks and soffits

Surface Prep: Power wash Primer: Jones-Blair #3090 White Multi-Grip 2 Acrylic latex. Two coats required.

Top Coat: Jones-Blair Acrylithane C-HS #4400-000 Acrylic Urethane White. Two coats required.

Color: JB #4400-000 Valero White

Metal decks and soffits

Surface Prep: Power wash , clean with Bleach or as recommended by paint Manufacturer. Remove all rust, sands, runs, oils, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2, or SSPC-SP3 respectively Repairs: Patch existing holes in deck. After cleaning and sanding, fill holes with Bondo metal filler. Sand holes level with deck surface. clean area before priming.

Primer: Jones-Blair #33010/99951 White Epoxy Urethane Primer if factory finished or coated with two component urethane.One coat required.

Top coats: Jones-Blair Acrylithane C-HS #4400-000 Acrylic Urethane.

One coat required applied at 1.5-2.0 mils dft. Color: JB #4400-000 Valero White

Caulking: At Canopy lights, gutters and leaders. Seal with premium approved waterproof and mildew

resistant white caulking, prior to painting.(Do not use silicone)

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primer: Jones-Blair #33010-CA/99951 White Epoxy Urethane Primer if factory finished or coated with two component urethane. Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

11

2.1.9 I.D. / Price Sign Poles and Sign Cans ( painted by sign installer)

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15077 White Multi-Purpose Alkyd Primer

Top Coats: Jones-Blair #4460-032 Valero Gray Acrylithane C-HS Acrylic Urethane. Two coats required. Color: JB #4460-032 Valero Gray

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primer: Jones-Blair #3090 White or 3091 Gray Multi-Grip 2 Acrylic applied at 1.5-2.0 mils dft. Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

2.1.10 Pipe Bollards

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively.

Primer: Jones-Blair #15632 Gray Multi-Purpose Alkyd applied at 1.5-2.0 mils dft.

Top Coats: Jones-Blair Acrylithane C-HS Acrylic Urethane below. Two coats required.

Colors: For Bollards/Safety Poles At Pump Island 4430-000 Valero Teal At Building 4460-032 Valero Gray At Air & Water Island 4460-032 Valero Gray

At Pay Telephones 4460-032 Valero Gray

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primer: Jones-Blair #3091 Multi-Grip 2 Acrylic Latex applied at 1.5- 2.0 mils dft.

12

Top Coat: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

2.1.11 Hand Rails Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively.

Primer: Jones-Blair #15632 Gray Multi-Purpose Alkyd applied at 1.5-2.0 mils dft.

Top Coats: Jones-Blair Acrylithane C-HS Acrylic Urethane #4460-032 Valero Gray. Two coats required.

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primer: Jones-Blair #3091 Multi-Grip 2 Acrylic Latex applied at 1.5- 2.0 mils dft. Top Coat: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

2.1.12 Building flashing / ( standing seam if applicable ) Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively.

Primer: Jones-Blair #33010/99951 White Epoxy Urethane Primer if factory-finished or coated with two component urethane. One coat required.

Top Coat: Jones-Blair Acrylithane C-HS #4430-000 Teal Acrylic Urethane. 2 coats required. Color: JB #4430-000 Valero Teal

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA Primer: Jones-Blair #33010-CA/99951 White Epoxy Urethane Primer if Factory-finished or coated with two component urethane.

Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

13

2.1.13 Electrical Boxes - Exterior

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15077 White Multi-Purpose Alkyd Primer

Top Coats: Jones-Blair #4460-032 Valero Gray Acrylithane C-HS Acrylic Urethane. Two coats required. Color: JB #4460-032 Valero Gray

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primer: Jones-Blair #3091 Multi-Grip 2 Acrylic Latex applied at 1.5- 2.0 mils dft. Top Coat: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

2.1.14 H.V.A.C. Housing, Compressor Housings Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15632 Gray Multi-Purpose Alkyd applied at 1.5-2.0 mils dft.

Top Coats: Jones-Blair Acrylithane C-HS Acrylic Urethane #4460-032 Valero Gray. Two coats required.

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primer: Jones-Blair #3091 Gray Multi-Grip 2 Acrylic applied at 1.5-2.0 mils dft. Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

14

2.1.15 Equipment Screens (if applicable )

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #3091 Multi-Grip 2 Acrylic Latex applied at 1.5- 2.0 mils dft.

Top Coats: Jones-Blair Acrylithane C-HS Acrylic Urethane #4460-032 Valero Gray. Two coats required.

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primer: Jones-Blair #33010-CA/99951 White Epoxy Urethane Primer if Factory-finished or coated with two component urethane.

Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

2.1.16 Fuel Vent Pipes and Brackets Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15632 Gray Multi-Purpose Alkyd applied at 1.5-2.0 mils dft.

Top Coats: Jones-Blair Acrylithane C-HS Acrylic Urethane #4460-032 Valero Gray. Two coats required.

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primer: Jones-Blair #3091 Gray Multi-Grip 2 Acrylic applied at 1.5-2.0 mils dft. Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

15

2.1.17 Street Boxes / Manhole covers

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15077 White Multi-Purpose Alkyd Primer Top Coats: Colors: All colors listed below are Jones-Blair safety enamel

colors: Do not paint pre-finished covers as indicated below. 2.1.17a Sub Pump Multi-port manhole covers Color: New covers are pre-finished Black, do not paint Paint only existing older covers 2.1.17b Tank Level Sensor Manhole cover Color: Jones-Blair #1902 Black 2.1.17c Monitor Well Manhole cover Color: New covers are pre finished White, do not paint Paint only existing older covers. 2.1.17d Vapor Recovery and Fill covers Unleaded - 1900/5931 Jones-Blair White Unleaded Plus - 1918 Jones-Blair Blue Premium Unleaded - 1917 Jones-Blair Red Diesel - 1910 Jones-BlairYellow Vapor Recovery - 1920 Jones Blair Orange

2.2 BUILDING INTERIOR Refer to plans for colors and location Colors used on the inside of store sales area are as follows: GREEN : Benjamin Moore # HC 124 Caldwell Green ( Satin Finish ) IDYLLIC BLUE Devoe ICI # 1516 ( Satin Finish ) 2.2.1 CMU – all areas

Surface Prep: Remove all loose mortar by rubbing surface with masonry block or

scrape with 6” to 8” floor scraper to remove any mortar fins or protrusions. Remove all loose foreign matter with a stiff broom and coat before contamination occurs. Spot Prime: Jones-Blair #3781 Acrylic Latex Block Filler @ 10.0-18.0 mils dft.

16

Top coats: Jones-Blair Rust-Not HP Acrylic. Two coats minimum. @ 2.5-4.0 mils dft. Colors: Satin finish

Back Rooms & Office: To match Valero White Sales Area & Checkout: Green & Blue as listed above

for interior. Rest Rooms: Tiled walls ..see plans 2.2.2 Drywall – all areas … WALLS and CEILING

Surface Prep: Paint only clean, dry surfaces. Remove any laitance, dust or

contaminants by hand cleaning. Spot Prime: Jones-Blair #3090 White. One coat required. Texture: Walls and Ceiling shall be smooth

Top Coat: Jones-Blair Rust-Not HP Satin Latex Finish. Two coats required. WALLS Back Rooms & Office: To match Valero White in 3032

Sales Area & Checkout: Green & Blue as listed above for interior. Rest Rooms: Tiled walls ..see plans CEILING: Restroom only: Valero White Acrylic #3032 2.2.3 Doors and Frames ….INTERIOR

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #3090 Multi-Grip 2 Acrylic. One coat.

Top Coat: Jones-Blair Rust-Not HP Acrylic Gloss. Color: Copper Bangle (SW-1350 if adjacent walls are green. Color: White (3032 Valero White if adjacent walls are white or blue. Cased Jones-Blair Rust-Not HP Gloss Acrylic Coating, Opening: @ 2.5-4.0 mils dft. Colors and finish: see top coat above

17

2.2.4 STORE FRONT FRAME and ENTRY DOORS NEW: Manufactured by Vistawall Prefinished Custom Color developed by VALSPAR Industrial Coatings For Vistawall to match …. Color: Dark Bronze Finish EXISTING: To be painted by Electrostatic Method

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: As recommended by Company performing process

Top Coat: Color: Dark Bronze Matt/Satin Finish REPAINTS: If existing color is Dark Bronze: Primer: Jones-Blair #33010 Ureprime Epoxy Urethane Primer. One coat required. Top Coats: Jones-Blair Acrylithane 4500-xxxx series to match Dark Bronze. Two coats required. REPAINTS: If existing color is Black: Primer: Jones-Blair #33010 Ureprime Epoxy Urethane Primer. One coat required. Top Coats: Jones-Blair #45637-CA Acrylithane HS-3 Satin Finish Urethane. Two coats required.

2.2.5 Exposed surfaces of Walk-In Cooler (Applies to Volume Shoppers )

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #3090 Multi-Grip 2 White Acrylic Primer. One coat required.

Top Coat: SEE SECTION 2.2 for green and Blue interior colors

Also refer to plans 2.2.6 Restroom Interior (if not FRP or Ceramic Tile)

Surface Prep: CMU

18

Remove all loose mortar by rubbing surface with masonry block or scrape with 6” to 8” floor scraper to remove any mortar fins or protrusions. Remove all loose foreign matter with a stiff broom and coat before contamination occur.

Surface Prep: DRYWALL

See section 2.2.2 Primer: Jones-Blair #3090 Multi-Grip 2 Acrylic White Primer @3 mils dry.

Top Coat: Jones-Blair #3032 Rust-Not Hp Acrylic Valero White. Two coats required.

2.2.7 Painting over existing ceramic wall tile Primer: Jones-Blair #3090 Multi-Grip 2 Acrylic Primer @ 2 mils dry. Finish : Jones-Blair Rust-Not HP Acrylic Gloss applied at 2-3 mils dft in color required by owner. 2.3 CAR WASH - Exterior 2.3.1 Building Fascia

For Surface Prep, primer and Top coat. SEE SECTION 2.1 ….. Building Exterior

2.3.2 Pipe Bollards – Exterior and Interior

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. INSTALL YELLOW PVC SLEEVE WITH TOP PVC CAP Slide sleeve over steel bollard, fill all spaces with foam sealant. Install and secure pvc cap in place with a top set screw

2.3.3 Electrical Boxes - Exterior Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15077 White Multi-Purpose Alkyd Primer

Top Coats: Jones-Blair #4460-032 Valero Gray Acrylithane C-HS Acrylic Urethane. Two coats required.

19

Color: JB #4460-032 Valero Gray

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primer: Jones-Blair #3091 Gray Multi-Grip 2 Acrylic applied at 1.5-2.0 mils dft. Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

2.3.4 Mechanical Rooms, Door/Frame/Header - Exterior Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15077 White Multi-Purpose Alkyd Primer

Top Coats: Jones-Blair #4460-032 Valero Gray Acrylithane C-HS Acrylic Urethane. Two coats required. Color: JB #4460-032 Valero Gray APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primer: Jones-Blair #3090 White Multi-Grip 2 Acrylic applied at 1.5-2.0 mils dft. Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

2.3.5 Storerooms, Door/Frame/Header - Exterior

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15077 White Multi-Purpose Alkyd Primer

Top Coats: Jones-Blair #4460-032 Valero Gray Acrylithane C-HS Acrylic Urethane. Two coats required. Color: JB #4460-032 Valero Gray

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

20

Primer: Jones-Blair #3090 White Multi-Grip 2 Acrylic applied at 1.5-2.0 mils dft. Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

2.3.6 Restrooms, Door/Frame/Header - Exterior (if required) Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15077 White Multi-Purpose Alkyd Primer

Top Coats: Jones-Blair #4460-032 Valero Gray Acrylithane C-HS Acrylic Urethane. Two coats required. Color: JB #4460-032 Valero Gray

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primer: Jones-Blair #3090 White Multi-Grip 2 Acrylic applied at 1.5-2.0 mils dft.

Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall

match the appropriate Valero standards. Two coats required over specified primer.

2.3.7 Bay, Door/Frame/Header – Exterior ( If Applicable )

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15077 White Multi-Purpose Alkyd Primer

Top Coats: Jones-Blair #4460-032 Valero Gray Acrylithane C-HS Acrylic Urethane. Two coats required. Color: JB #4460-032 Valero Gray or match wall color.

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA

Primer: Jones-Blair #3090 White Multi-Grip 2 Acrylic applied at 1.5-2.0 mils dft.

21

Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall match the appropriate Valero standards. Two coats required over specified primer.

2.3.8 Exhaust Fan Covers - Exterior Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #15077 White Multi-Purpose Alkyd Primer

Top Coats: Jones-Blair #4460-032 Valero Gray Acrylithane C-HS Acrylic Urethane. Two coats required. Color: JB #4460-032 Valero Gray or match wall color.

APPROVED PRIMER AND TOP COAT FOR CALIFORNIA Primer: Jones-Blair #3090 White Multi-Grip 2 Acrylic applied at 1.5-2.0 mils dft.

Top Coats: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall

match the appropriate Valero standards. Two coats required over specified primer.

2.4 CAR WASH - Interior 2.4.1 Restroom CMU (if applicable)

Surface Prep: Remove all loose mortar by rubbing surface with masonry block or

scrape with 6” to 8” floor scraper to remove any mortar fins or protrusions. Remove all loose foreign matter with a stiff broom and coat before contamination occurs. Color: Valero White. Apply two coats. 2.4.2 BAY CMU ---- OPTIONAL FINISHES

OPTION 1 - PAINTING AN EXISTING CAR WASH BUILDINGS WITHOUT REMOVING THE EXISTING CARWASH EQUIPMENT:

22

Valero/Shamrock 2 CAR WASH PAINTING SPECIFICATIONS 1. GENERAL This specification supersedes any previously written or implied specification for

painting any existing or new car wash structures for maximum performance at on-site locations. (Includes California)

1.1 Scope This specification covers Valero’s requirements for the painting of piping,

equipment and typical interior car wash structures. 1.2 Workmanship All work required by this specification shall be performed in accordance with

the recommendations of the manufacturer, Jones-Blair Company, Dallas, Texas or its' distributors. The use of coatings other than those specified herein requires Valero Construction Management approval.

2. GENERAL PREPARATION 2.1 Before applying any coating, all contamination, loose paint, rust, mill scale,

soaps, oil, grease, dirt, dust and chemicals are to be removed from interior paintable surfaces by chemical wet blasting, hydroblast cleaning or power tools. Abrasive blast cleaning may be necessary on heavily rusted areas, but may be prohibitive in some areas. Allow to dry completely.

2.2 Existing coatings such as epoxy or urethane shall be roughened prior to

coating, when necessary, for proper intercoat adhesion by brush-off blast cleaning or power sanding.

3. SURFACE PREPARATION FOR RECOATING

23

3.1 Metal Surfaces Only loose, cracked, brittle, or non-adherent coating shall be removed

unless otherwise specified. Cleaning shall be performed two Inches beyond the damaged area in all directions or until tightly adhered coating is obtained. Rust spots shall be thoroughly cleaned. Prime immediately after cleaning and surfaces is completely dry.

3.2 The contractor shall have the option to remove all old coating from area

where the amount of damaged or loose coating is excessive. 3.3 Do not prime or coat the following surfaces unless they have been

previously painted: (a) Non-ferrous metal surfaces such as aluminum, copper, brass, or

Monel; (b) Stainless steel; (c) Glass, tile or ceramic; (d) Machined or finished operating parts of machinery, valves or rubber

hoses. 3.4 Primer Prime all bare ferrous metal with Jones-Blair #33010 White Epoxy Urethane

Primer. (In CA. use #33010-CA) Catalyze 3:1 ratio with #99951 catalyst. Apply primer a minimum of 2 mils DFT. Allow primer to dry a minimum of 8 hours before recoating at 70°-80° F and 50% RH. Primer may be reduced up to 15% with Jones-Blair #21092. Do not thin for brush or roller application.

4.0 PREVIOUSLY PAINTED SURFACES OF BLOCK, CONCRETE, ROUGH-

TEXTURED BRICK, ETC. 4.1. Clean as in Section 2 and roughen existing gloss coatings such as

urethanes or epoxy. If fillers are removed by cleaning the surface, fill again with Jones-Blair #3781 Acrylic Latex Block Filler. Block filler may be applied by roller but for maximum filling, work filler into crevices with a brush. Allow surfaces to thoroughly dry before top-coating.

5.0 NEW SURFACES AS IN 4.0

24

5.1 Clean surfaces free of oil, grease, wax and other foreign matter. Fill all porous surfaces with Jones-Blair #3781 Acrylic Latex Block Filler. For best results brushing should follow spray or roller application while the filler is still wet. A gallon of block filler will typically cover 50 - 150 square feet depending on the surface. Allow block filler to dry 24 - 48 hours before applying finish coats.

6.0 NEW GLAZED BRICK/PORCELAIN 6.1 Clean free of all foreign matter and prime with Jones-Blair #33010 or

#33010-CA Epoxy Urethane Primer as in 3.4 7.0 FINISH COATS 7.1 Urethane Two-Package System 7.2 Jones-Blair Gloss Acrylithane C-HS #4400-000 White Aliphatic Urethane shall be

applied as the topcoats at a minimum of 2 mils DFT. (In CA. use #4600-011 White. Two coats are required for either coating. These coatings shall be applied to all primed and roughened surfaces. Acrylithane C-HS catalyzes 7:1 ratio with #99979 catalyst. #4600-011 catalyzes 3:1 ratio with 99951 Catalyst. These coatings are very suitable for this application because of the varied types of environments ranging from severely corrosive environments to mild atmospheric conditions. Aliphatic Urethane also has excellent recoatability.

7.3 Mixing and application techniques Jones-Blair Acrylithane C-HS is a two component system and must be

mixed. A 7:1 mixing ratio is required. Mix one (7/8) gallon of Acrylithane base material with one (1) pint of #99979 catalyst. (In CA. use #4600-011 mixed with #99951 Catalyst) Up to one-half (1/2) pint of #21092 thinner may be added, per gallon, of mixed paint for spray application. For brush and roller application thinning is not normally required. Apply Acrylithane only to thoroughly dry surfaces. When applying at temperatures exceeding 80° F, addition of as much as three fluid ounces (1/5 of pint) of #21093 drying retardant per gallon of Acrylithane C-HS or Acrylithane HS-4 (CA.) is recommended. This prevents dry spray and undesired fast drying on the surface being covered as well as on brushes and rollers. For application in temperatures below 45°F, it is recommended that 1/4 ounce of #99011 be added per catalyzed gallon of Acrylithane C-HS or HS-3. Either Acrylithane product or #33010 (#33010-CA in California) Ureprime White Primer may be recoated after one hour at 70°F and 50% RH.

ADDITIONAL INFORMATION: For additional technical data on this or other specified products, contact

Jones-Blair Paint Co., 2728 Empire Central, Post Office Box 35286, Dallas, TX 75235, or Watts (800) 492-9400, Customer Service Fax: (800) 325-6321, Attn: Will Dryden, National Sales/Marketing Mgr. - Oil Services.

25

Other information regarding MSDS, etc may be found on the Jones-Blair/Valero website at www.jones-blair.com/valero/default.htm.

Note All conduit and plumbing line wall penetrations are to be caulked or sealed with DAP 8641 Clear Silicone Sealant. To be applied after ALL painting is completed

OPTION 2 -FIBERGLASS PANELS FOR EXISTING CARWASH

BUILDING WITH EXISTING EQUIPMENT TO BE REPLACED ROYAL RENEW PANELING SYSTEM

To be installed on walls and ceiling by others. OPTION 3 -FIBERGLASS COATING FOR NEW CARWASH BUILDING…. FOR NEW TO INDUSTRY SITES Surface Prep: Walls and ceiling will be thoroughly sanded to a smooth surface. Surface cleaning will be done with air blasting equipment. Primer: A two-part Epoxy Urethane Primer designed primarily for concrete adhesion will be used. (Jones-Blair #33010 White) Top Coat: Fiberglass coating Color: White 5W-1 ( Lilly Gelcoat colors ) ALL MATERIAL AND INSTALLATION WILL BE BY SEGUIN FIBERGLASS ( ph. 800 829 - 2250 ) 2.4.3 Bay Conduits / J-Boxes

Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively.

2.4.4 Top Coat: Jones-Blair #4400-000 Valero White Acrylithane C-HS Urethane. 2.4.5 Two coats minimum applied at 1.5-2.0 mils dft per coat. 2.4.6 Roof Downspout and wall Hangers ( If applicable ) Surface Prep: Remove all rust, sand, runs, oil, grease, chalk or other

contaminants by SSPC-SP1, SSPC-SP2 or SSPC-SP3 respectively. Primer: Jones-Blair #3090 Multi-Grip 2 Acrylic Latex.

26

Top Coat: Jones-Blair Acrylithane C-HS #4460-032 Valero Gray or match adjacent wall. Two coats minimum.

2.5 PAVEMENT STRIPING AND RAMP STAINS Jones-Blair #4677 Alkyd YELLOW ZONE MARKING PAINT. Surface Preparation: Power wash and clean parking lot surface. Striping: Use 4” wide yellow stripes. Spacing of stripes must comply with plans or as dictated by local coded. ADA STRIPED ACCESS AND SYMBOL Color of stripes and wheelchair symbol must comply with local codes. Jones-Blair ADA Blue latex #8531 for Symbol.

PAINT FOR CONCRETE AND SEALED ASPHALT Jones-Blair #4676 Alkyd White Zone Paint for Concrete or Sealed Asphalt on ADA area. Color: B29YZ2 Lead-Free Yellow PAINT FOR UNSEALED ASPHALT Jones-Blair #Acrylic Latex Acrylic Latex Traffic Marking Paint Color: Jones-Blair #407-308 Lead Free Yellow ADA RAMP STAIN AND FINISH

NOTE: DO NOT STAIN RAMPS UNLESS REQUIRED BY LOCAL CODES

Jones-Blair Ranchero Acrylic Penetrating Concrete Stain Color: #3061 Chippendale After grooves are marked in concrete, brush on stain. Do not apply sealer. Allow for proper drying time per Manufacturer. 2.6 WOOD TRELLIS…….. Chippendale Apply the following stain Jones-Blair Chippindale #3061 APPROVED STAIN FOR CALIFORNIA Finish coat: Jones-Blair Chippindale #3061

27

2.7 EXTERIOR ICE MERCHANDISER Vendor usually provides a merchandiser factory painted with Sand If merchandiser has to be painted on site, use the following

Primer: Jones-Blair #15077 White Multi-Purpose Alkyd Primer Top Coats: Jones-Blair #4460-032 Valero Gray Acrylithane C-HS Acrylic Urethane. Two coats required. Color: JB #4460-032 Valero Gray

END