validering av casmo-5m / simulate-3435228/... · 2011. 8. 17. · dämpkvot – förhållandet i...

53
ES10023 Examensarbete 30 hp Oktober 2010 Validering av Casmo-5M / Simulate-3 Validation of Casmo-5M / Simulate-3 Joseph Shaya

Upload: others

Post on 05-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • ES10023

    Examensarbete 30 hpOktober 2010

    Validering av Casmo-5M / Simulate-3

    Validation of Casmo-5M / Simulate-3

    Joseph Shaya

  • Teknisk- naturvetenskaplig fakultet UTH-enheten Besöksadress: Ångströmlaboratoriet Lägerhyddsvägen 1 Hus 4, Plan 0 Postadress: Box 536 751 21 Uppsala Telefon: 018 – 471 30 03 Telefax: 018 – 471 30 00 Hemsida: http://www.teknat.uu.se/student

    Abstract

    Validering av Casmo-5M / Simulate-3

    Validation of Casmo-5M / Simulate-3

    JOSEPH SHAYA

    The objective of this M. Eng. Diploma work was to validate the new version,CASMO-5M, and compare the results with CASMO-4E, by using the same input inboth programs. The tasks that were included in this work was to compareTIP-measures, k-effective curves (warm), k-effective curves (cold), the effect of voidon k-effective, the isothermal temperature coefficient (ITC), the moderatortemperature coefficient (MTC), damping ratio calculations, internal effect in a fuelbundle of a BA-rod, the speed of BA-out burn, impact of xenon, falling control rod,margins and isotopes.

    The TIP-measures showed that the differences were small for all reactors, at most0,6% nodal improvement by C5M (Casmo-5M) for Oskarshamn 3. The warmmeasurements of k-effective showed that C5M had a higher value for all cycles ofOskarshamn 1, 2 and 3 in comparison to C4E (Casmo-4E). Important improvementswere noted for C5M, which solved the “tub behaviour” that used to occur inOskarshamn 2 when using C4E. For all three reactors the the differences of the coldk-effective measurements between C5M and C4E were decreasing by growing reactorcycle, especially after changing fuel rods from SVEA64 to SVEA 96 Optima/Optima2.

    The new fuel (Optima/Optima2) contains part length fuel rods and contains 10x10fuel rod positions to compare with the old 8x8/9x9 previously used in all threereactors.The effects of void on k-effective were consistently better in C5M than in C4E for allthree reactors. The isothermal coefficient was lower in C5M in comparison to C4Efor all three reactors, except in the middle of cycle 34 for O2 where C5M was higherthan C4E. The average of MTK is lower in C5M then in C4E for all three reactors.The uniform Doppler coefficients are consistently lower in C5M than in C4E, for allthree reactors. In the damping ratio calculations C5M is marginally higher than C4E.For all three reactors C5M consistently calculates a higher effect in the studied fuelbundle of a BA-rod in comparison to C4E, at 0% and 80% void.

    The speed differences of the BA burnout are marginal, but notably exhibits aconsistent behaviour. C5M has a higher power development in the beginning of thecycle’s for all voids (0-80%) and lower in the end of the cycles compare to C4E. Thexenon impact has the same trend for all three reactors. C4E has a consistently highervalue than C5M in the beginning of the cycles and contrary in the end of cycles.The test of the falling control rod has proved that in C5M we maintain a worse fueltemperature- and moderator coefficient which results in a higher reactivity maximumvalue, compared to C4E.

    In C5M we find that the margins are consistently higher than C4E for all threereactors, which is to be preferred.Regarding the isotopes, the only difference observed in the test was that according toC5M there is approximately 50% less U-237. This does not have a big effect on thereactor because this amounts to only about 1/1000 of the total amount of the fuel inthe core.

    Tryckt av: Ångströmslaboratoriet, Uppsala UniversitetISSN: 1650-8300, ES10023Examinator: Kjell PernestålÄmnesgranskare: Michael ÖsterlundHandledare: Christer Netterbrant

  • Förord

    Examinationsarbetet utfördes på kärnkraftverket i Oskarshamn, OKG, vid

    avdelningen för Teknik, Härd och bränsle (TH). Min uppgift var att

    validera Casmo-5M, den nya versionen, mot den nuvarande Casmo-4E. I

    valideringen ingick Oskarshamns alla tre reaktorer.

    Ett stort tack vill jag rikta till min handledare Christer Netterbrant. Med sin

    erfarenhet och kunskap har han handlett, förklarat och beskrivit diverse

    problematik genom examinationsarbetets gång. Att han alltid var

    tillgänglig, var en aktiv och närvarande handledare gjorde att kvalitén på

    rapporten blev bra men även att min inlärningsprocess under

    examensarbetet kunde fortgå optimalt.

    Ett tack till Ann-Christin Olsson som språk- och skrivgranskat rapporten

    liksom Marcus Nilsson som granskat och godkänt den.

    Jag vill även tacka övriga i avdelningen som hjälpt till under arbetets gång.

    För att förstå detta examensarbete krävs kunskap i nivå med

    ”Kärnkraftsteknik 7,5 HP” på Universitet.

    Simpevarp, våren 2010

  • Innehållsförteckning Sida

    Abstract 2

    Förord 3

    Nyckel tal 6

    1 Sammanfattning 7

    2 Bakgrund 8

    3 Metod 9

    SIMULATE version 6.07.23 9 CMS-Link 10

    4 Beräkningsresultat 10

    4.1 Oskarshamn 1 10 4.1.1 TIP (Transverse in core) 11 4.1.2 K-effektiv (varma mätningar) 12 4.1.3 k-effektiv (kalla mätningar) 13

    4.1.4 Voidens inverkan på k-effektiv 14 4.1.5 Moderator temperatur koefficient – MTK 15 4.1.6 Isotermisk temperaturkoefficient – ITK 17

    4.1.7 Dämpkvotsberäkningar 18

    4.1.8 Intern effekt i bränsleknippe av BA-stav 18 4.1.9 Hastighet av BA-utbränningen 19 4.1.10 Inverkan av xenonförgiftning 20

    4.1.11 Fallande styrstav 20 4.1.12 Dopplerkoefficient 21

    4.1.13 Marginaler 22 4.1.14 Isotoper 22

    4.2 Oskarshamn 2 23 4.2.1 TIP 23

    4.2.2 K-effektivkurvor (varma mätningar) 24 4.2.3 k-effektiv (kalla mätningar) 26 4.2.4 Voidens inverkan på k-effektiv 27

    4.2.5 Moderator temperatur koefficient – MTK 28 4.2.6 Isotermisk temperaturkoefficient – ITK 30 4.2.7 Dämpkvotsberäkningar 31 4.2.8 Intern effekt i bränsleknippe av BA-stav 32

    4.2.9 Hastighet av BA-utbränningen 32 4.2.10 Inverkan av Xe-135 34 4.2.11 Fallande styrstav 34 4.2.12 Dopplerkoefficient 35 4.2.13 Marginaler 36

    4.2.14 Isotoper 36

    4.3 Oskarshamn 3 37 4.3.1 TIP 37 4.3.2 k-effektivkurvor (varma mätningar) 38 4.3.3 k-effektiv (kalla mätningar) 38 4.3.4 Voidens inverkan på k-effektiv 39

  • 4.3.5 Moderator temperatur koefficient – MTK 40

    4.3.6 Isotermisk temperaturkoefficient – ITK 42 4.3.7 Dämpkvotsberäkningar 44 4.3.8 Intern effekt i bränsleknippe av BA-stav 44 4.3.9 Hastighet av BA-utbränningen 45 4.3.10 Inverkan av Xenon 46

    4.3.11 Fallande styrstav 47 4.3.12 Dopplerkoefficient 48 4.3.13 Marginaler 48 4.3.14 Isotoper 50

    5 Redovisning av uppfyllda acceptanskriterier 52

    6 Slutsats 53

    7 Referenser 53

  • Nyckel tal

    Revision – byte av bränslepatroner samt underhåll

    Cykel – tiden mellan två revisioner

    BOC – beginning of cycle

    MOC – middle of cycle

    EOC – end of cycle

    Void – den volymandel av en ångvattenbildning som befinner sig i form

    av ånga

    RMS – root mean square

    MTK – moderatortemperaturkoefficient

    ITK – isotermisk temperaturkoefficient

    PCM – per cent mille, 10-5

    Härd – den inkapslade delen av reaktorn där bränslet befinner sig

    Dämpkvot – förhållandet i amplituden av en störning mellan aktuell period

    samt föregående.

    BA – brännbara absorbatorer

    Prompt kriticitet – okontrollerad effektökning i reaktorn

    CPR - Critical Power Ratio

    LHGR – Linear Heat Generation Rate

    APLHGR – Average planar Linear Heat Generation Rate

    O1, O2, O3 – Oskarshamn reaktor 1, 2, 3

  • 1 Sammanfattning

    En validering och verifiering av Casmo-5M version 1.06.00 med

    biblioteket e7r0.125.586 i kombination med Simulate-3 version 6.07.23

    har gjorts för härdberäkningar enligt rutinen i referens [1]. De deluppgifter

    som ingick i valideringen var TIP-mätningar, k-effektivkurvor (varma

    mätningar), k-effektivkurvor (kalla mätningar), voidens inverkan på k-

    effektiv, moderatortemperaturkoefficient (MTK), isotermisk temperatur-

    koefficient (ITK), dämpkvotsberäkningar, intern effekt i bränsleknippe av

    BA-stav, hastighet av BA-utbränningen, inverkan av xenon, fallande styr-

    stav (endast O3), marginaler och isotoper (endast O3).

    TIP-mätningarna visade marginella skillnader mellan C5M (Camo-5M)

    och C4E (Casmo-4E) för alla tre reaktorer, som mest 0,6 % nodalt

    förbättrat värde av C5M för Oskarshamn 3. I C5M låg de varma k-effektiv

    värdena högre än C4E för alla cykler i alla tre reaktorer. En viktig

    förbättring skedde främst i Oskarshamn 2, där den tidigare oönskade

    ”badkarskurvan” som uppstod i C4E försvann i C5M. I de kalla k-effektiv

    fallen uppstod en trend i alla cykler. Denna var minskad differens i k-

    effektiv mellan C5M och C4E, med ökande cykelnummer.

    Anmärkningsvärt är att efter byte av bränsletyp (från KWU/SVEA64 till

    Optima/Optima2) så övergick C5M till att ha ett lägre k-effektiv värde än i

    C4E, där fenomenet varit omvänt innan bränslebytet. Optima/Optima2

    innehåller dellånga stavar samt är ett 10x10 bränsle. De gamla bränslena

    hade 8x8- respektive 9x9-geometri. Voidens inverkan på k-effektiv var

    konsistent lägre i C5M än i C4E för alla tre reaktorer. Den isotermiska

    temperaturkoefficienten var lägre i C5M än i C4E i slutet av cyklerna för

    O1 respektive O2 och lägre för hela cykeln i O3. Av diagrammen framgår

    att ITK är mindre positiv i CASMO-5M vid låga temperaturer och mer

    negativ vid temperaturer nära drifttemperaturen. Medelvärdet av MTK är

    lägre i C5M än i C4E för alla tre block. Dopplerkoefficienten är lägre i

    C5M än i C4E för alla tre block.

    Dämpkvoterna visade sig vara marginellt lägre i C5M än i C4E för alla tre

    block. Den interna effekten i bränsleknippet av BA-staven var konsistent

    högre för C5M i jämförelse med C4E för alla tre block, både vid 0 % samt

    80 % void. Hastigheten av BA-utbränningen uppvisar en marginell men

    konsistent trend för alla tre block. C5M har en högre hastighet av BA-

    utbränningen i början av cyklerna än C4E för alla voidhalter men har en

    lägre hastighet av BA-utbränningen i slutet av cyklerna. Inverkan av

    xenonet uppvisar samma trend för alla tre reaktorer där C4E har ett

    konsistent högre värde än C5M i början av cyklerna och omvänt i slutet av

    cyklerna. Vid en fallande styrstav uppvisar C5M mindre negativa bränsle-

    och moderatortemperaturkoefficienter vilket medför en högre reaktivitets-

    topp. Marginalerna är konsistent bättre i C5M än C4E för alla tre reaktorer.

    I C5M finns mindre än hälften så mycket U-237 som i C4E.

  • 2 Bakgrund

    Figur 1. Här visas en översiktlig bild över en kokarvattenreaktor.

    Oskarshamns tre reaktorer är av typen kokarvattenreaktorer (BWR,

    Boiling Water Reactor). Som vi ser i figur 1 innebär en kokarvattenreaktor

    i stora drag att vi har en stor reaktortank där vattnet i härden används både

    för att kyla bränslet (svartfärgat och rektangulärt i nedre delen av

    reaktortanken) men också för att en del av det skall koka. Den bildade

    ånga avleds till en turbin som i sin tur driver en elgenerator. Den ånga som

    passerat turbinen förs vidare till en kondensator där man kyler ångan med

    hjälp av havsvatten. Den kondenserade ångan pumpas tillbaka till

    reaktortanken och på så sätt cirkulerar vattnet i en loop.

    För att förbättra härduppföljningen av reaktordriften på OKGs tre kokar-

    vattenreaktorer valideras hur bra Casmo-5M / Simulate-3 beskriver härd-

    uppföljningen jämfört med den tidigare använda versionen Casmo-4E /

    Simulate-3. Programmet använder sig av experimentellt baserade data/och

    tvärsnittsbibliotek för bl.a. uran. De beräknade resultaten jämförs med de

    uppmätta. På så sätt kan man förbättra noggrannheten i härdberäkningarna.

    Ju högre noggrannhet i härdberäkningarna desto säkrare och även mer

    kostnadseffektiv drift.

    Den primära säkerhetsfokusen är att även om den värst tänkbara händelsen

    i kärnkraftverket inträffar, skall inga yttre utsläpp ske. Vid daglig drift

    handlar det främst om att skydda bränslet. Driften skall alltså ske så

    optimalt som möjligt där temperaturerna inte får öka eller sjunka för

    kraftigt. Allt för att materialet och bränslet i härden inte skall utsättas för

    kraftiga påfrestningar.

    Att ett bränsle kokar torrt innebär att vattnet som omger bränslet, som

    agerar både som moderator och som kylmedel, helt kokar bort omkring det

    aktuella bränslet. Detta leder till att värmeöverföringen försämras kraftigt

    och kutstemperaturen stiger. Därmed ökar också bildningen av

    fissionsgaserna inne i kutsen och den sväller kraftigt. I de värsta fallen, där

    kapslingsröret inte hinner svälla upp och töjas i samma takt som kutsarna,

    kan det spricka. På så sätt förorenas hela primära systemet och en

    omfattande kontaminering måste ske.

    De olika parametrar som definierar marginalerna till detta är DO- marginal

    (dry out), CPR-marginal (Critical power ratio) samt LHGR (Linear Heat

  • Generation Rate). Ett skadat bränsle innebär, förutom det dyra bränslet, att

    man inte kan köra reaktorn på fulleffekt och tvingas till reaktorstopp.

    Den inherent inbyggda säkerheten innebär att när vattnet kokar bort,

    kommer även modereringen av neutronerna att försämras. På så sätt

    kommer även effekten i härden att sjunka. [2]

    3 Metod

    Casmo som levereras av Studsvik Scandpower AB, är programmet som

    löser tvådimensionella transportproblem i exakt heterogen geometri i

    härden för transporter av både neutron- och gammastrålning. I

    programmet kan man få en modellering av kriticitetsberäkningar för

    härden och bl.a. utbränningen av gadolinium, erbium, IFBA, stavar med

    brännbara absorbatorer. Nukleär data för CASMO samlas i så kallade

    bibliotek som innehåller mikroskopiska tvärsnitt i olika energigrupper.[4]

    Teoretiska skillnader mellan CASMO-4E och CASMO-5M

    De främsta skillnaderna versionerna emellan är bland annat att:

    C5M har kapaciteten att generera data för SIMULATE-5

    (multidimensionell data istället för tvådimensionell)

    C5M räknar med 586 energigrupper till skillnad från C4E’s 70 vid

    kutsberäkningar

    C5M använder sig av 19 energigrupper för att lösa tvådimensionella

    transportproblem i jämförelse med C4E’s 8 energigrupper

    Noggrannare modell för beräkning av gadoliniumutbränning

    Nya neutron och gamma bibliotek (JEF 2.2 och ENDF/B-VI baserat)[5]

    SIMULATE version 6.07.23

    SIMULATE-3 är en avancerad tvådimensionell nodal kod för analys av

    både BWR och

    PWR. Koden bygger på QPANDA neutronics modellen som använder sig

    av fjärde ordningens polynom som i sin tur representeras av intranodala

    fluxberäkningar i både fasta och termiska grupper. SIMULATE används

    bl.a. för kriticitets-, startup-, xenontransient-, TIP-beräkningar samt

    härduppföljning. I SIMULATE används input som via CMS-LINK

  • översätts (se nedan) och tillhandahålls från CASMO. På så sätt kan olika

    tvärsnittsmodeller förberäknas och anpassas för att motsvara användarens

    behov.[6]

    CMS-Link

    CMS-LINK är ett program som bearbetar CASMO Card Image-filer i ett

    binärt format där nukleär databibliotek används av SIMULATE-3, S3K

    och XIMAGE. Koden samlar bl.a. följande data från CASMO Card

    Bildfiler:

    Två-grupps makroskopiskt tvärsnitt

    Två-grupps avbrott faktorer

    Fissions produktdata

    Detektor-, kinetik-, isotop- samt spontan fissionsdata [7]

    4 Beräkningsresultat

    De valda parametrarna som behandlas i rapporten är

    TIP-mätningar

    k-effektivkurvor (varma mätningar)

    k-effektivkurvor (kalla mätningar)

    voidens inverkan på k-effektiv

    moderatortemperaturkoefficient (MTK)

    isotermisk temperaturkoefficient (ITK)

    dämpkvotsberäkningar

    intern effekt i bränsleknippe av BA-stav

    hastighet av BA-utbränningen

    inverkan av xenon

    fallande styrstav (endast O3)

    marginaler

    isotoper (endast O3)

    Anledningen till att vi valt dessa parametrar baseras antingen på att det

    skett specifika modellförbättring i den nya Casmo versionen (bl.a. inverkan

    av xenon) som behöver valideras eller parametrar som aktivt används i

    driftuppföljningen.

    När Casmo levereras kan kärnkraftverken modifiera indata matriserna efter

    egna behov. Detta baseras på tidigare driftinformation, erfarenhet av

    anläggningen och driften. Ingående frågor om förenklingar/antaganden,

    hänvisas till Christer Netterbrant.

    4.1 Oskarshamn 1

  • 4.1.1 TIP (Transverse in core)

    TIP-mätningar visar felprediktionen i procent som gjorts mellan verkliga

    k-effektivprofilen i härden och det predikterade som Casmo genererar.

    Felprediktion omkring 5 % placeras inom ”normal intervallet”.

    I tabell 1 visas de nodala avvikelserna som blir marginellt sämre i Casmo-

    5M jämfört med Casmo-4E. De radiella avvikelserna blir sämre med

    0,042 %-enheter i CASMO-5M.

    RMS CASMO-5M CASMO-4E

    ( %)

    Nod 5,976 5,975

    Radial 2,613 2,571

    Axial 4,269 4,286

    Tabell 1 O1 – cykel 15-22, 26-35. Medelvärden av RMS nodiellt, radiellt samt

    axiellt.

    I figur 2 presenteras TIP (nodalt) för samtliga cykler. Övre graf

    representerar CASMO-5M och den nedre CASMO-4E.

  • Figur 2 Oskarshamn 1. TIP (transverse in core) kurva. Punkterna visar

    felmarginalerna i prediktionen för cykel 15-22 och 26-35. De heldragna

    linjerna är endast markeringar av punkterna. Övre diagrammet är

    C5M(Casmo-5M) och nedre C4E (Casmo-4E).

    4.1.2 K-effektiv (varma mätningar)

    k-effektiv, även kallad multiplikationsfaktorn, anger förhållandet mellan

    antalet neutroner i en neutrongeneration och den näst föregående

    generationen. En reaktor som är kritisk genererar konstant effekt om k-

    effektiv är 1,0 vilket innebär att av de neutroner som genereras vid en

    fission ska precis en neutron förorsaka en ny fission. Med varma

    mätningar avses k-effektiv mätas då reaktorn är ”varm” och uppnått

    jämvikt vid fulleffekt.[2]

    Enligt figur 2 är k-effektiv för CASMO-5M är högre i alla cykler i

    jämförelse med CASMO-4E.

  • Figur 2 Oskarshamn 1. Cykel 15-22 och 26-35. CASMO-5M markeras med

    fyrkanter och CASMO-4E med svarta prickar.

    4.1.3 k-effektiv (kalla mätningar)

    I tabell 2 presenteras medelvärdet av k-effektiv för alla cykler. Inom

    parentes presenteras medelvärdet av k-effektiv för cykel 31-35.

    Enligt tabell 2 är medelvärdet av standardavvikelsen för alla cykler

    marginellt lägre i CASMO-5M än i CASMO-4E. Enligt samma tabell har

    medelvärdet av k-effektiv för alla cykler försämrats till 1,00768 i

    CASMO-5M mot CASMO-4E’s 1,00617. Vilket är 151 pcm högre i

    CASMO-5M jämfört med CASMO-4E.

    CASMO-5M CASMO-4E

    k-medel 1,00768 (1,00577) 1,00617 (1,00624)

    Standardavvikelse [pcm] 150,50 (126,5) 151,32 (127,5)

    Tabell 2 O1 – cykel 15-22 och 26-35, (cykel 31-35). Medelvärden av k-effektiv

    samt standardavvikelse.

    I figur 3 presenteras k-effektiv för lokala kritiska mätningar

  • Figur 3. Oskarshamn 1 för cyklerna 15-22 och 26-35. CASMO-5M markeras med

    fyrkanter och CASMO-4E med svarta prickar.

    En tydlig trend i figur 3 är att k-effektiv för CASMO-5M blir lägre än i

    CASMO-4E vid cykel 32. Att enbart ta hänsyn till cykel 32 t o m 35 inne-

    bär att k-effektiv medelvärdet för dessa istället blir 1,00577 för CASMO-

    5M och 1,00624 för CASMO-4E. Vilket är 47 pcm lägre i CASMO-5M

    jämfört med CASMO-4E.

    Anledningen till denna skillnad är troligen att man vid cykel 31 infört ett

    nytt bränsle. Det nya bränslet innehåller dellånga stavar (Optima/Optima2)

    som ersatt gammalt 9x9 (KWU, gammalt tyskt bränsle), samt 8x8

    SVEA64 bränsle.

    4.1.4 Voidens inverkan på k-effektiv

    När effekten i härden ändras, förändras void halten i reaktorn. Detta får

    dock inte påverka k-effektiv. Reaktiviteten per förändrad effektsprocent

    bör vara konstant i ett idealt fall, så att k-effektiv inte påverkas.[3]

    I tabell 3 presenteras k-effektiv i ”beginning of cycle” (BOC) samt ”end of

    cycle” (EOC).

    Värdena i tabell 3, som är en sammanfattning av figur 4, visar skillnaden i

    k-effektiv (pcm) vid fulleffektsdrift jämfört med deleffektsdrift där

    reaktoreffekten styrts ned längs reglerlinjen. Lägre värden innebär att k-

    effektiv varierar mindre vid effektändringar, vilket är att eftersträva.

    Pcm/% representerar antalet pcm som skiljer emellan varje nedgången

    procent i reaktoreffekten. Noll pcm/% hade varit idealiskt men detta

    uppnås inte i praktiken pga komplexiteter i modellerna.

    Enligt tabell 3 och 4 varierar k-effektiv mindre i CASMO-5M än i

    CASMO-4E, mätt i pcm per förändrad effektsprocent, samt visar

    förbättringar genom minskningar på 1 pcm/% för samtliga block.

    Undantaget BOC för cykel 30 samt EOC för cykel 31, där de är lika.

    EFPH står för antalet fulleffektstimmar och med flöde menas

    huvudcirkulationsflödet.

  • BOC Casmo-5M Casmo-4E EOC Casmo-5M Casmo-4E

    Cykel 30 131 152 115 144

    pcm/% 6 6 5 6

    Cykel 31 128 146 128 148

    pcm/% 5 6 6 6

    Cykel 32 113 137 116 142

    pcm/% 5 6 5 6

    Tabell 3 O1 - Sammanfattning av tabell 4.

    CASMO-5M / O1 c30 EFPH K-eff Power % c30 EFPH K-eff Power %

    936,6 1,00782 100,0 64,79 6116,6 0,99604 100,0 64,79

    936,6 1,00651 76,5 42,25 6116,6 0,99489 77,0 42,25

    0,00131 0,00115

    5,13725 3,96552

    c31 EFPH K-eff Power % c31 EFPH K-eff Power %

    1419,5 1,00814 100,0 64,79 6562,8 1,00027 100,0 64,79

    1419,5 1,00686 76,0 42,25 6562,8 0,99899 77,0 42,25

    0,00128 0,00128

    5,01961 4,41379

    c32 EFPH K-eff Power % c32 EFPH K-eff Power %

    1319,7 1,00926 100,0 64,79 6575,4 1,00752 100,0 64,79

    1319,7 1,00813 75,5 42,25 6575,4 1,00636 76,5 42,25

    0,00113 0,00116

    4,43137 4,00000

    CASMO-4E / O1c30 EFPH K-eff Power % c30 EFPH K-eff Power %

    936,6 1,00704 100,0 64,79 6116,6 0,99488 100,0 64,79

    936,6 1,00552 76,5 42,25 6116,6 0,99344 77,0 42,25

    0,00152 0,00144

    5,96078 4,96552

    c31 EFPH K-eff Power % c31 EFPH K-eff Power %

    1419,5 1,00704 100,0 64,79 6562,8 0,99932 100,0 64,79

    1419,5 1,00558 76,0 42,25 6562,8 0,99784 77,0 42,25

    0,00146 0,00148

    5,72549 5,10345

    c32 EFPH K-eff Power % c32 EFPH K-eff Power %

    1319,7 1,00853 100,0 64,79 6575,4 1,00676 100,0 64,79

    1319,7 1,00716 75,5 42,25 6575,4 1,00534 76,5 42,25

    0,00137 0,00142

    5,37255 4,89655

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc Tabell 4.Detaljerad tabell för förändringen av effekten (pcm/%) vid förändrad

    effektsdrift för cykel 30-32.

    4.1.5 Moderator temperatur koefficient – MTK

    MTK mäts i reaktivitet per grad förändring av moderator temperaturen

    (pcm/grad). Negativ MTK kan agera som ett inherent (naturlagsbaserat) säkerhetssystem. Negativ MTK medför undermoderering i härden, vilket gör

    att systemet självreglerande och icke skenande. En positiv MKT skulle göra

    systemet instabilt, där risken för torrkokning av bränslet blir hög.

  • I CASMO-4E har man tidigare använt standardtemperaturmatrisen (S3C)

    som gör beräkningar vid temperaturerna 293, 393, 493 respektive 559 K,

    med THs (avdelningen för teknik härd och bränsle) tillägg vid 320, 360

    och 443 K. I CASMO-5M användes den nya standardmatrisen (S3C) som

    ger beräkningar vid temperaturerna 293, 323, 375, 425, 475 och 559 K.

    Därav hoppen i graferna i figur 4 för MTK vid olika temperaturer.

    Enligt tabell 5 är medelvärdet av MTK i CASMO-5M lägre än i CASMO-

    4E.

    BOC Casmo-5M Casmo-4E EOC Casmo-5M Casmo-4E

    Cykel 32 3,83 4,27 6,03 6,62

    pcm/°C

    Tabell 5 Medelvärde av MTK för Oskarshamn 1.

    20 62 104

    27

    34

    41

    48

    55 69

    76

    83

    90

    97 111

    118

    125

    132

    139

    146

    153

    160

    167

    174

    181

    188

    195

    202

    209

    216

    223

    230

    237

    244

    251

    258

    265

    272

    279

    286

    -10,00

    -5,00

    0,00

    5,00

    10,00

    15,00

    MTK - O1

    BOC_C5M

    BOC_C4E

    grader Celsius

    pcm

    /gra

    d

    20 8040 60 100

    25

    30

    35 45

    50

    55 65

    70

    75 85

    90

    95 105

    110

    115

    120

    125

    130

    135

    140

    145

    150

    155

    160

    165

    170

    175

    180

    185

    190

    195

    200

    205

    210

    215

    220

    225

    230

    235

    240

    245

    250

    255

    260

    265

    270

    275

    280

    285

    -5,00

    0,00

    5,00

    10,00

    15,00

    20,00

    MTK - O1

    EOC_C5M

    EOC_C4E

    grader Celsius

    pcm

    /gra

    d

    Figur 4. Graferna ovan presenterar MTK i början (BOC) och i slutet (EOC) av

    cykel 32 för O1. C4E står för CASMO-4E och C5M står för CASMO-5M. x-axeln

    representeras av temperaturen 20-286 grader Celsius.

  • 4.1.6 Isotermisk temperaturkoefficient – ITK

    Den isotermiska temperaturkoefficienten mäts i (k286C-k20C)/(286-20),

    vilken definieras som pcm/°C, vilket är förändringen i k-effektiv genom

    förändringen i vattnets temperatur.

    Enligt tabell 6 är skillnaden av ITK i början av cykeln noll men i slutet av

    cykeln fås marginellt lägre ITK i CASMO-5M.

    (k286C-k20C)/(286-20) CASMO-5M CASMO-4E

    [pcm/°C]

    BOC 0,00003 0,00003

    MOC - -

    EOC 0,00004 0,00005

    Tabell 6 O1 – cykel 32. ITK i början samt i slutet av cykeln.

    . Av figur 5 framgår att ITK är mindre positiv i CASMO-5M vid låga

    temperaturer och mer negativ vid temperaturer nära drifttemperaturen.

    Anledningen till hacken i kurvorna är okänd.

    20

    30

    40

    50

    70

    90

    100

    140

    150

    170

    190

    200

    240

    250

    280

    286

    1,09150

    1,09350

    1,09550

    1,09750

    1,09950

    1,10150

    ITK - O1 (cykel 32)

    BOC_C5M

    BOC_C4E

    Temperatur (grad C)

    K-e

    ffekt

    iv

    20

    30

    40

    50

    70

    90

    100

    140

    150

    170

    190

    200

    240

    250

    280

    286

    1,06500

    1,07000

    1,07500

    1,08000

    1,08500

    ITK - O1 (cykel 32)

    EOC_C5M

    EOC_C4E

    Temperatur (grad C)

    K-e

    ffekt

    iv

    Figur 5. ITK kurvorna ovan presenterar k-effektiv i början (BOC) respektive i

    slutet (EOC) av cykel 32 för O1. Blå linje representerar CASMO-5M och den

    orangea CASMO-4E

  • 4.1.7 Dämpkvotsberäkningar

    När en störning inträffar skall systemet kunna dämpa detta. Störningen

    mäts i form av amplituddämpningen från nuvarande samt föregående

    amplitud.

    Enligt tabell 7 minskar dämpkvotsvärdena i alla tre cykler i CASMO-5M.

    Skillnaden versionerna emellan är marginell.

    BOC Casmo-5M Casmo-4E EOC Casmo-5M Casmo-4E

    Cykel 29 0,669 0,678 0,570 0,580

    Cykel 30 0,525 0,532 0,635 0,652

    Cykel 32 0,613 0,622 0,710 0,718

    Tabell 7 O1. Dämpkvoter för cykel 29-32 i början resp. i slutet av cyklerna.

    4.1.8 Intern effekt i bränsleknippe av BA-stav

    För att undvika användning av styrstavar för sänkning av

    överskottsreaktiviteten i härden används s.k. brännbara absorbatorer.

    Dessa har den fördelen att de verkar jämnare än styrstavar och att deras

    verkan avtar allt eftersom utbränningen ökar och man får på så sätt en

    automatisk justering av reaktiviteten. Den nuklid som används är Gd-157 i

    form av dioxid.

    I tabell 8 presenteras effekten i bränsleknippet e29_2-4.p10. Effekten är

    realterad till medeleffekten i knippet. Numreringen av bränslet beskriver

    höjdläget av knippet i härden. Värdena som presenteras i tabellen är alltså

    den utvecklade effekt i knippet. Där 1 är lika med 100 % och den differens

    ifrån 1 är den reducerade effekt som de brännbara absorbatorerna orsakat

    och därmed kompenserat en inskjutning av styrstavar.

    Enligt tabell 8 har CASMO-5M konsistent högre effekt i den studerade

    BA-staven i jämförelse med CASMO-4E, både vid 0 % och 80 % VOID.

    Det innebär att de brännbara absorbatorerna utbränns snabbare än

    förväntat.

    O1 CASMO-4E CASMO-5M CASMO-4E CASMO-5M0% VOID 0% VOID 80% VOID 80% VOID

    e29_2.p10 0,916 0,925 0,884 0,888

    e29_25.p10 0,905 0,914 0,882 0,886

    e29_3.p10 0,902 0,911 0,882 0,886

    e29_35.p10 0,898 0,907 0,883 0,887

    e29_4.p10 0,896 0,904 0,883 0,888

    Filnamn

    Tabell 8. Intern effekt i bränsleknippet e29 för olika voidhalter.

  • 4.1.9 Hastighet av BA-utbränningen

    BA-utbränningen bör ske kontinuerligt, så att effektfördelningen i övriga

    bränsleknippen inte störs.

    I figur 6 visas kurvor av hur interneffekten utvecklas i bränsleknippet

    (e29_2-4.p10) av en BA-stav i 20 %, 40 %, 60 % samt 80 % VOID.

    Skillnaden är marginell men CASMO-5M har vid samtliga fall högre

    effektutveckling i början av utbränningen i jämförelse med CASMO-4E,

    vilket leder till en omvänd situation i slutet av utbränningen där CASMO-

    4E påvisar högre effekt i BA-staven än CASMO-5M.

    Figur 6. Ovan presenteras grafer över hastigheten av BA- utbränningen. De röda

    graferna representerar CASMO-5M och de blåa CASMO-4E.

  • 4.1.10 Inverkan av xenonförgiftning

    Xenonuppkomsten förgiftar reaktorn. Det innebär att reaktorns optimala

    drift störs. Det beror på att Xe-135 har ett stort absorptionstvärsnitt som

    innebär att xenon absorberar neutroner som är avsedda att leda till en

    fission och därmed minskar reaktiviteten i reaktorhärden.[2]

    Enligt figur 7 är skillnaderna är marginella. Dock ligger CASMO-4E

    konsistent högre än CASMO-5M i början av effektändringen och omvänt i

    slutet av effektändringen.

    Anledningen till detta är att i och med att CASMO-4E ligger högre i

    utbränningen i början så hinner xenonet att brinna ut snabbare än i

    CASMO-5M. Därmed får vi högre koncentration i slutet av

    effektändringen i CASMO-5M.. Anledningen till hacken i kurvorna är

    okänd.

    950

    970

    990

    1010

    1030

    1050

    1070

    1090

    1110

    1130

    1150

    Inverkan av Xenon - O1

    C4E_boc

    C5M_boc

    Tid efter effektändring

    mo

    lekyl

    er/

    cm

    ^3

    900

    920

    940

    960

    980

    1000

    1020

    1040

    1060

    1080

    1100

    Inverkan av Xenon - O1

    C4E_eoc

    C5M_eoc

    Tid efter effektändring

    mo

    lekyl

    er/

    cm

    ^3

    Figur 7. Kurvan presenterar koncentrationen av Xenon efter effektändring. Den

    orangea kurvan representerar CASMO-5M och den blåa CASMO-4E.

    4.1.11 Fallande styrstav

    Se 4.3.11, Oskarshamn 3.

  • 4.1.12 Dopplerkoefficient

    Sannolikheten för en neutron att undkomma absorption under

    nedbromsning uttrycks med resonanspassagefaktorn, P. Denna faktor

    minskar (mäts i tvärsnitt, barns=10-24

    cm2) vid ökad temperatur. Minskar

    temperaturen, ökar faktorn men hamnar under ett mindre neutronenergin

    spektrum. Detta kallas även för dopplerfenomenet. Dopplerkoefficienten

    mäts i förändrad reaktiviet per grad celcius.

    I tabell 9 presenteras medelvärden av dopplerkoefficienten, i början samt i

    slutet av cykel 32. Dopplerkoefficienten i CASMO-5M är konsistent lägre

    än i CASMO-4E, enligt tabell 9 och figur 8.

    Medelvärde CASMO-5M CASMO-4E

    [pcm/°C]

    BOC -2,25 -2,10

    MOC - -

    EOC -2,25 -2,09

    Tabell 9 O1 – cykel 32. Medelvärden av dopplerkoefficienten i början och i

    slutet av cykeln.

    20

    30

    40

    50

    70

    90

    100

    140

    150

    170

    190

    200

    240

    250

    280

    286

    -2,85E+000

    -2,75E+000

    -2,65E+000

    -2,55E+000

    -2,45E+000

    -2,35E+000

    -2,25E+000

    -2,15E+000

    -2,05E+000

    -1,95E+000

    -1,85E+000

    Dopplerkoefficient - O1 (cykel 32)

    BOC_C5M

    EOC_C5M

    BOC_C4E

    EOC_C4E

    Temperatur (grad C)

    pcm

    /gra

    d C

    Figur 8. Kurvor för dopplerkoefficienten. CASMO-5M representeras av de nedre

    kurvorna (blå och röd) och CASMO-4E av de övre (gul och grön).

  • 4.1.13 Marginaler

    De marginaler som beaktas är främst CPR, LHGR och APLHGR. CPR

    används som en indikation på dryout i bränslet, dvs. att bränslet kokar

    torrt. LHGR mäts i kW/m används som en indikation på smältande

    bränsle, utsläpp av fissionsgaser samt mekanisk stress. Och APLHGR som

    beskriver detsamma som LHGR men istället betonar

    medeleffektspåverkan av bränslet.

    Enligt tabell 10 är marginalerna i CASMO-5M genomgående högre än i

    CASMO-4E. Resultaten innebär att marginalerna visat sig vara större än

    förväntat och därmed minskat risken för torrkokning av bränslet.

    Medelvärde CASMO-5M CASMO-4E

    CPR( %) 20,30 19,85

    LHGR( %) 12,46 10,97

    APLHGR ( %) 24,62 23,97

    Tabell 10 O1 – cykel 15-35. Medelvärden av CPR, LHGR samt APLHGR.

    4.1.14 Isotoper

    Se 4.3.14 Oskarshamn 3.

  • 4.2 Oskarshamn 2

    4.2.1 TIP

    TIP-mätningar visar felprediktionen i procent som gjorts mellan verkliga

    k-effektivprofilen i härden och det predikterade som Casmo genererar.

    Felprediktion omkring 5% placeras inom ”normal intervallet”.

    I tabell 11 visas nodala avvikelser som blir 0,034 %-enheter bättre för O2 i

    CASMO-5M. I samma tabell visas även de radiella avvikelserna som blir

    0,155 %-enheter sämre för Oskarshamn 2 i CASMO-5M.

    RMS CASMO-5M CASMO-4E

    ( %)

    Nod 4,327 4,361

    Radial 1,871 1,716

    Axial 3,182 3,272

    Tabell 11 O2 – cykel 13-34. Medelvärden av RMS nodiellt, radiellt samt axiellt.

    I figur 5 presenteras TIP RMS (nodalt) för samtliga cykler. Övre graf

    representerar CASMO-5M och den nedre CASMO-4E.

  • Figur 5 TIP (transverse in core) kurva. Punkterna visar felmarginalerna i prediktionen

    för cykel 13-34. De heldragna linjerna är endast markeringar av punkterna. Övre

    diagrammet är C5M(Casmo-5M) och nedre C4E (Casmo-4E).

    4.2.2 K-effektivkurvor (varma mätningar)

    k-effektiv, även kallad multiplikationsfaktorn, anger förhållandet mellan

    antalet neutroner i en neutrongeneration och den näst föregående

    generationen. En reaktor som är kritisk genererar konstant effekt om k-

    effektiv är 1,0 vilket innebär att av de neutroner som genereras vid en

    fission ska precis en neutron förorsaka en ny fission. Med varma

    mätningar avses k-effektiv mätas då reaktorn är ”varm” och uppnått

    jämvikt vid fulleffekt.[2]

    Enligt figur 6 försvinner ”badkarskurvan” i CASMO-5M, något man haft

    problem med i CASMO-4E. ”Badkarskurvan” innebär att k-effektiv

    varierar under cykelns gång, då den under ideala omständigheter önskas

    vara konstant.

    Figur 6 Oskarshamn 2. Cykel 21-34. k-effektivkurvor. CASMO-5M markeras med fyrkanter och CASMO-4E med svarta prickar.

  • Badkarskurvan har man betraktat som en brist i CASMO-4E (och de flesta

    andra liknande 2D-program) och innebär att k-effektiv varierar under

    cykeln. k-effektiv bör ju vara konstant och helst lika med 1 vid stationära

    förhållanden. CASMO-5M löser alltså det problemet för O2.

  • 4.2.3 k-effektiv (kalla mätningar)

    I tabell 12 presenteras medelvärdet av k-effektiv för alla cykler vid lokala

    kritiska mätningar. Inom parentes presenteras medelvärdet av k-effektiv

    för cykel 30-34.

    CASMO-5M CASMO-4E

    k-medel 1,00471 (1,00456) 1,00430 (1,00407)

    Standardavvikelse (pcm) 129,81 (83,67) 130,41 (86,67)

    Tabell 12 O2 – cykel 12-34 (cykel 30-34). Medelvärden av k-effektiv samt

    standardavvikelse.

    Enligt tabell 12 är medelvärdet av standardavvikelsen för alla cykler

    marginellt lägre i CASMO-5M än i CASMO-4E. Medelvärdet av k-

    effektiv för alla cykler försämras till 1,00456 i CASMO-5M mot CASMO-

    4E’s 1,00407. Det är 49 pcm högre i CASMO-5M jämfört med CASMO-

    4E.

    I figur 7 presenteras k-effektivkurvorna. CASMO-5M markeras med

    fyrkanter och CASMO-4E med svarta prickar i graferna. Vid cykel 30

    börjar man ladda med ett nytt bränsle (Optima2) i Oskarshamn 2 som inne-

    håller dellånga stavar. Westinghouse är tillverkaren av det nya bränslet

    istället för tidigare franska Areva. Detta kan vara anledningen till att

    CASMO-5M närmar sig CASMO-4E’s värden av k-effektiv där

    differensen minskar med ökad cykellängd, detta enligt figur 7.

    Figur 7 Oskarshamn 2. Cykel 12-34. CASMO-5M markeras med fyrkanter

    och CASMO-4E med svarta prickar. De heldragna linjerna är endast markeringar.

  • 4.2.4 Voidens inverkan på k-effektiv

    När effekten i härden ändras, förändras void halten i reaktorn. Detta får

    dock inte påverka k-effektiv. Reaktiviteten per förändrad effektsprocent

    bör vara konstant i ett idealt fall, så att k-effektiv inte påverkas.[3]

    I tabell 13 presenteras k-effektiv i ”beginning of cycle” (BOC) samt ”end

    of cycle” (EOC).

    Värdena i tabell 3, som är en sammanfattning av figur 4, visar skillnaden i

    k-effektiv (pcm) vid fulleffektsdrift jämfört med deleffektsdrift där

    reaktoreffekten styrts ned längs reglerlinjen. Lägre värden innebär att k-

    effektiv varierar mindre vid effektändringar, vilket är att eftersträva.

    Pcm/% representerar antalet pcm som skiljer emellan varje nedgången

    procent i reaktoreffekten. Noll pcm/% hade varit idealiskt men detta

    uppnås inte i praktiken pga komplexiteter i modellerna.

    Enligt tabell 13 och 14 varierar k-effektiv mindre i CASMO-5M än i

    CASMO-4E, mätt i pcm per förändrad effektsprocent, samt visar

    förbättringar genom minskningar på 1-2 pcm/% för samtliga block. EFPH

    står för antalet fulleffektstimmar och med flöde menas

    huvudcirkulationsflödet.

    BOC Casmo-5M Casmo-4E EOC Casmo-5M Casmo-4E

    Cykel 29 0,00107 0,00121 0,00092 0,00113

    Pcm/proc 4 5 3 4

    Cykel 32 0,00104 0,00118 0,00101 0,00130

    Pcm/proc 4 5 4 5

    Cykel 34 0,00096 0,00116 0,00090 0,00116

    Pcm/proc 4 4 3 4

    Tabell 13 Sammanfattning av tabell 14.

  • CASMO-5M / O2c29 EFPH K-eff Power % c29 EFPH K-eff Power %

    692,3 1,00300 106,0 68,83 EFPH 8123,5 0,99522 106,0 68,83

    692,3 1,00193 80,5 45,45 EFPH 8123,5 0,99430 77,0 45,45

    0,00107 0,00092

    4,19608 3,17241

    c32 EFPH K-eff Power % c32 EFPH K-eff Power %

    718,6 1,00337 106,0 68,83 EFPH 6305,7 1,00191 106,0 68,83

    718,6 1,00233 80,0 45,45 EFPH 6305,7 1,00090 81,0 45,45

    0,00104 0,00101

    4,00000 4,04000

    c34 EFPH K-eff Power % c34 EFPH K-eff Power %

    876,0 1,00377 106,0 68,83 EFPH 9316,7 0,99750 106,0 68,83

    876,0 1,00281 79,5 45,45 EFPH 9316,7 0,99660 78,5 45,45

    0,00096 0,00090

    3,62264 3,27273

    CASMO-4E/ O2c29 EFPH K-eff Power % O2 EFPH K-eff Power %

    692,3 1,00190 106,0 68,83 EFPH 8123,5 0,99334 106,0 68,83

    692,3 1,00069 80,5 45,45 EFPH 8123,5 0,99221 77,0 45,45

    0,00121 0,00113

    4,74510 3,89655

    c32 EFPH K-eff Power % O2 EFPH K-eff Power %

    718,6 1,00209 106,0 68,83 EFPH 6305,7 1,00008 106,0 68,83

    718,6 1,00091 80,0 45,45 EFPH 6305,7 0,99878 81,0 45,45

    0,00118 0,00130

    4,53846 5,20000

    c34 EFPH K-eff Power % O2 EFPH K-eff Power %

    876,0 1,00282 106,0 68,83 EFPH 9316,7 0,99596 106,0 68,83

    876,0 1,00166 79,5 45,45 EFPH 9316,7 0,99480 78,5 45,45

    0,00116 0,00116

    4,37736 4,21818

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc Tabell 14. .Detaljerad tabell för förändringen av effekten (pcm/%) vid förändrad

    effektsdrift för cykel 30-32.

    4.2.5 Moderator temperatur koefficient – MTK

    MTK mäts i reaktivitet per grad förändring av moderator temperaturen

    (pcm/grad). Negativ MTK kan agera som ett inherent (naturlagsbaserat) säkerhetssystem. Negativ MTK medför undermoderering i härden, vilket gör

    att systemet självreglerande och icke skenande. En positiv MKT skulle göra

    systemet instabilt, där risken för torrkokning av bränslet blir hög.

    I CASMO-4E har man tidigare använt standardtemperaturmatrisen (S3C)

    som gör beräkningar vid temperaturerna 293 K, 393 K, 493 K respektive

    559 K, med THs (avdelningen för teknik härd och bränsle) tillägg vid 320

    K, 360 K och 443 K. I CASMO-5M användes den nya standardmatrisen

    (S3C) som ger beräkningar vid temperaturerna 293 K, 323 K, 375 K, 425

    K, 475 K och 559 K. Därav hoppen i graferna i figur 9 för MTK vid olika

    temperaturer.

    Enligt tabell 15 är medelvärdet av MTK i cykeln är lägre i CASMO-5M än

    i CASMO-4E.

    Medelvärde CASMO-5M CASMO-4E

    (pcm /grad C)

    BOC 1,21 1,59

    MOC 4,04 4,48

    EOC 4,73 5,14

    Tabell 15 O2 – cykel 34. Medelvärde av MTK för Oskarshamn 2.

  • 20 80

    50 11026

    32

    38

    44 56

    62

    68

    74 86

    92

    98

    104116

    122

    128

    134

    140

    146

    152

    158

    164

    170

    176

    182

    188

    194

    200

    206

    212

    218

    224

    230

    236

    242

    248

    254

    260

    266

    272

    278

    284

    -15

    -10

    -5

    0

    5

    10

    MTK - O2

    BOC_C5M

    BOC_C4E

    grader Celsius

    pcm

    /gra

    d

    20 80

    50 11026

    32

    38

    44 56

    62

    68

    74 86

    92

    98

    104 116

    122

    128

    134

    140

    146

    152

    158

    164

    170

    176

    182

    188

    194

    200

    206

    212

    218

    224

    230

    236

    242

    248

    254

    260

    266

    272

    278

    284

    -10

    -5

    0

    5

    10

    15

    MTK - O2

    MOC_C5M

    MOC_C4E

    grader Celsius

    pcm

    /gra

    d

    2 0 8 04 0 6 0 1 0 0

    2 5

    3 0

    3 5 4 5

    5 0

    5 5 6 5

    7 0

    7 5 8 5

    9 0

    9 5 1 0 5

    1 1 0

    1 1 5

    1 2 0

    1 2 5

    1 3 0

    1 3 5

    1 4 0

    1 4 5

    1 5 0

    1 5 5

    1 6 0

    1 6 5

    1 7 0

    1 7 5

    1 8 0

    1 8 5

    1 9 0

    1 9 5

    2 0 0

    2 0 5

    2 1 0

    2 1 5

    2 2 0

    2 2 5

    2 3 0

    2 3 5

    2 4 0

    2 4 5

    2 5 0

    2 5 5

    2 6 0

    2 6 5

    2 7 0

    2 7 5

    2 8 0

    2 8 5

    - 1 0

    - 5

    0

    5

    1 0

    1 5

    2 0

    M T K - O 2

    EO C _ C 5 M

    EO C _ C 4 E

    g r a d e r C e ls iu s

    pc

    m/g

    rad

    Figur 9. Graferna ovan presenterar MTK i början (BOC) och i slutet (EOC) av cykel 32 för O1.

    C4E står för CASMO-4E och C5M står för CASMO-5M. x-axeln representeras av temperaturen

    20-286 grader Celsius.

  • 4.2.6 Isotermisk temperaturkoefficient – ITK

    Den isotermiska temperaturkoefficienten mäts i (k286C-k20C)/(286-20),

    vilken definieras som pcm/°C, vilket är förändringen i k-effektiv genom

    förändringen i vattnets temperatur.

    Enligt tabell 16 är skillnaden av ITK i början och i mitten av cykeln noll

    men i slutet av cykeln fås marginellt lägre ITK i CASMO-5M.

    (k286C-k20C)/(286-20) CASMO-5M CASMO-4E

    [pcm/°C]

    BOC 0,00002 0,00002

    MOC -0,00001 -0,00001

    EOC -0,00004 -0,00003

    Tabell 16 O2 – cykel 34. ITK i början samt i slutet av cykeln.

    I figur 10 presenteras kurvorna för k-effektiv i början (BOC), i mitten

    (MOC) samt i slutet (EOC) av cykel 34 för O2. Blå linje representerar

    CASMO-5M och den orangea CASMO-4E. Av figur 10 framgår att ITK är

    mindre positiv i CASMO-5M vid låga temperaturer och mer negativ vid

    temperaturer nära drifttemperaturen. Anledningen till hacken i kurvorna är

    okänd.

    20

    30

    40

    50

    70

    90

    100

    140

    150

    170

    190

    200

    240

    250

    280

    286

    1,11200

    1,11400

    1,11600

    1,11800

    1,12000

    1,12200

    ITK - O2 (cykel 34)

    BOC_C5M

    BOC_C4E

    Temperatur (grad C)

    K-e

    ffe

    ktiv

    20

    30

    40

    50

    70

    90

    100

    140

    150

    170

    190

    200

    240

    250

    280

    1,06600

    1,06800

    1,07000

    1,07200

    1,07400

    1,07600

    ITK - O2 (cykel 34)

    MOC_C5M

    MOC_C4E

    Temperatur (grad C)

    K-e

    ffek

    tiv

  • 20

    30

    40

    50

    70

    90

    100

    140

    150

    170

    190

    200

    240

    250

    280

    1,02500

    1,02700

    1,02900

    1,03100

    1,03300

    1,03500

    1,03700

    1,03900

    1,04100

    1,04300

    1,04500

    ITK - O2 (cykel 34)

    EOC_C5M

    EOC_C4E

    Temperatur (grad C)

    K-e

    ffek

    tiv

    Figur 10. ITK kurvorna ovan presenterar k-effektiv i början (BOC) respektive i slutet (EOC) av

    cykel 32 för O1. Blå linje representerar CASMO-5M och den orangea CASMO-4E

    4.2.7 Dämpkvotsberäkningar

    När en störning inträffar skall systemet kunna dämpa detta. Störningen

    mäts i form av förhållandet av amplituddämpningen från nuvarande samt

    föregående amplitud.

    Enligt tabell 17 är CASMO-5M marginellt lägre i slutet av alla tre cykler

    men är marginellt högre i början av cyklerna 30 och 33.

    BOC Casmo-5M Casmo-4E EOC Casmo-5M Casmo-4E

    Cykel 30 0,455 0,444 0,499 0,500

    Cykel 33 0,554 0, 552 0,647 0,649

    Cykel 34 0,580 0,585 0,627 0,635

    Tabell 17 O2. Dämpkvoter för cykel 29-32 i början, mitten samt i slutet av

    cyklerna.

  • 4.2.8 Intern effekt i bränsleknippe av BA-stav

    För att undvika användning av styrstavar för sänkning av

    överskottsreaktiviteten i härden används s.k. brännbara absorbatorer.

    Dessa har den fördelen att de verkar jämnare än styrstavar och att deras

    verkan avtar allt eftersom utbränningen ökar och man får på så sätt en

    automatisk justering av reaktiviteten. Den nuklid som används är Gd-157 i

    form av dioxid.

    I tabell 18 presenteras effekten i bränsleknippet e31_2-5.p10. Effekten är

    realterad till medeleffekten i knippet. Numreringen av bränslet beskriver

    höjdläget av knippet i härden. Värdena som presenteras i tabellen är alltså

    den utvecklade effekt i knippet. Där 1 är lika med 100 % och den differens

    ifrån 1 är den reducerade effekt som de brännbara absorbatorerna orsakat

    och därmed kompenserat en inskjutning av styrstavar.

    Enligt tabell 18 har CASMO-5M konsistent högre effekt i den studerade

    BA-staven i jämförelse med CASMO-4E, både vid 0 % och 80 % VOID.

    Det innebär att de brännbara absorbatorerna utbränns snabbare än

    förväntat.

    O2 CASMO-4E CASMO-5M CASMO-4E CASMO-5M0% VOID 0% VOID 80% VOID 80% VOID

    e31_2.p10 1,122 1,127 1,081 1,083

    e31_3.p10 0,924 0,933 0,897 0,900

    e31_35.p10 0,911 0,919 0,893 0,895

    e31_4.p10 0,907 0,916 0,893 0,895

    e31_45.p10 0,902 0,910 0,892 0,895

    e31_5.p10 0,900 0,909 0,892 0,895

    Filnamn

    Tabell 18. Intern effekt i bränsleknippet e29 för olika voidhalter.

    4.2.9 Hastighet av BA-utbränningen

    BA-utbränningen bör ske kontinuerligt, så att effektfördelningen i övriga

    bränsleknippen inte störs.

    I figur 11 visas hur interneffekten utvecklas i bränsleknippet

    (e31_2-5.p10) av en BA-stav. Skillnaden är marginell men CASMO-5M

    har högre effektutveckling i bränslet i början av utbränningen i jämförelse

    med CASMO-4E. Detta leder också till att CASMO-5M har lägre effekt-

    utveckling i slutet av utbränningen i jämförelse med CASMO-4E. Detta

    kan ses i figur 11 nedan då den röda kurvan korsar den blåa.

  • Figur 11. Ovan presenteras grafer över hastigheten av BA- utbränningen. De röda

    graferna representerar CASMO-5M och de blåa CASMO-4E.

  • 4.2.10 Inverkan av Xe-135

    Xenonuppkomsten förgiftar reaktorn. Det innebär att reaktorns optimala

    drift störs. Det beror på att Xe-135 har ett stort absorptionstvärsnitt som

    innebär att xenon absorberar neutroner som är avsedda att leda till en

    fission och därmed minskar reaktiviteten i reaktorhärden.[2]

    Enligt figur 12 är skillnaderna är marginella. Dock ligger CASMO-4E

    konsistent högre än CASMO-5M i början av cykeln och omvänt i slutet av

    cykeln. Anledningen till detta är att i och med att CASMO-4E ligger högre

    i utbränningen i början så hinner xenonet att brinna ut snabbare än i

    CASMO-5M. Därmed får vi högre koncentration i slutet av

    effektändringen i CASMO-5M. Anledningen till hacken i kurvorna är

    okänd.

    1150

    1200

    1250

    1300

    1350

    1400

    1450

    1500

    1550Inverkan av Xenon - O2

    C4E_boc

    C5M_boc

    Tid efter effektändring

    mo

    lekyl

    er

    / cm

    ^3

    1050

    1100

    1150

    1200

    1250

    1300

    1350

    1400

    1450

    Inverkan av Xenon - O2

    C4E_eoc

    C5M_eoc

    Tid efter effektändring

    mo

    lekyl

    er/

    cm

    ^3

    Figur 12. Kurvan presenterar koncentrationen av Xenon efter effektändring. Den

    orangea kurvan representerar CASMO-5M och den blåa CASMO-4E.

    4.2.11 Fallande styrstav

    Se Oskarshamn 3.

  • 4.2.12 Dopplerkoefficient

    Sannolikheten för en neutron att undkomma absorption under

    nedbromsning uttrycks med resonanspassagefaktorn, P. Denna faktor

    minskar (mäts i tvärsnitt, barns=10-24

    cm2) vid ökad temperatur. Minskar

    temperaturen, ökar faktorn men hamnar under ett mindre neutronenergin

    spektrum. Detta kallas även för dopplerfenomenet. Dopplerkoefficienten

    mäts i förändrad reaktiviet per grad celcius.

    I tabell 19 presenteras medelvärden av dopplerkoefficienten i början, i

    mitten samt i slutet av cykel 34. Dopplerkoefficienten i CASMO-5M är

    konsistent lägre än i CASMO-4E, enligt tabell 19.

    Medelvärde CASMO-5M CASMO-4E

    (pcm/°C)

    BOC -2,23 -2,06

    MOC -2,18 -2,03

    EOC -2,23 -2,07

    Tabell 19 O2 – cykel 34. Medelvärden av dopplerkoefficienten i början och i

    slutet av cykeln.

    I figur 13 presenteras grafer för dopplerkoefficienten för cykel 34 i O2 för

    BOC, MOC och EOC (beginning, middle och end of cycle).

    20

    30

    40

    50

    70

    90

    100

    140

    150

    170

    190

    200

    240

    250

    280

    286

    -2,65E+000

    -2,55E+000

    -2,45E+000

    -2,35E+000

    -2,25E+000

    -2,15E+000

    -2,05E+000

    -1,95E+000

    -1,85E+000

    -1,75E+000

    Dopplerkoefficient - O2 (cykel 34)

    BOC_C5M

    MOC_C5M

    EOC_C5M

    BOC_C4E

    MOC_C4E

    EOC_C4E

    Temperatur (grader C)

    pcm

    /gra

    d C

    Figur 13. Kurvor för dopplerkoefficienten. CASMO-5M representeras av de nedre

    kurvorna (röd, mörkblå och gul) och CASMO-4E av de övre (brun, grön och

    ljusblå).

  • 4.2.13 Marginaler

    De marginaler som beaktas är främst CPR, LHGR och APLHGR. CPR

    används som en indikation på dryout i bränslet, dvs. att bränslet kokar

    torrt. LHGR mäts i kW/m används som en indikation på smältande

    bränsle, utsläpp av fissionsgaser samt mekanisk stress. Och APLHGR som

    beskriver detsamma som LHGR men istället betonar

    medeleffektspåverkan av bränslet.

    Enligt tabell 20 är marginalerna i CASMO-5M genomgående högre än i

    CASMO-4E. Resultaten innebär att marginalerna visat sig vara större än

    förväntat och därmed minskat risken för torrkokning av bränslet.

    Anledningen till att vi får negativa LHGR-värden beror på att man ändrat

    gränserna för driften, och när vi kör om våra beräkningar så får vi stora

    negativa värden. Huvudsaken är att värdena sinsemellan programmen inte

    varierar mer än en procent.

    Medelvärde CASMO-5M CASMO-4E

    CPR( %) 15,08 14,67

    LHGR( %) -3,23 -3,96

    APLHGR ( %) 27,91 27,57

    Tabell 20 O2 – cykel 15-35. Medelvärden av CPR, LHGR samt APLHGR.

    4.2.14 Isotoper

    Se 4.3.14, Oskarshamn 3.

  • 4.3 Oskarshamn 3

    4.3.1 TIP

    TIP-mätningar visar felprediktionen i procent som gjorts mellan verkliga

    k-effektivprofilen i härden och det predikterade som Casmo genererar.

    Felprediktion omkring 5% placeras inom ”normal intervallet”.

    I tabell 21 presenteras de nodala avvikelserna som blir 0,06 %-enheter

    bättre i CASMO-5M. I samma tabell visas de radiella avvikelserna som

    blir sämre med 0,275 %-enheter i CASMO-5M jämfört med CASMO-4E.

    RMS CASMO-5M CASMO-4E

    ( %)

    Nod 4,360 4,420

    Radial 2,048 1,773

    Axial 3,121 3,512

    Tabell 21 O3 – cykel 1-30. Medelvärden av RMS nodiellt, radiellt samt axiellt.

    I figur 9 presenteras TIP RMS (nodalt) för samtliga cykler. Övre graf

    representerar CASMO-5M och den nedre CASMO-4E.

  • Figur 9 Oskarshamn 3. Cykel 1-31. TIP (transverse in core) kurva. Punkterna

    visar felmarginalerna i prediktionen för cykel 13-34. De heldragna

    linjerna är endast markeringar av punkterna. Övre diagrammet är

    C5M(Casmo-5M) och nedre C4E (Casmo-4E).

    4.3.2 k-effektivkurvor (varma mätningar)

    k-effektiv, även kallad multiplikationsfaktorn, anger förhållandet mellan

    antalet neutroner i en neutrongeneration och den näst föregående

    generationen. En reaktor som är kritisk genererar konstant effekt om k-

    effektiv är 1,0 vilket innebär att av de neutroner som genereras vid en

    fission ska precis en neutron förorsaka en ny fission. Med kalla mätningar

    avses k-effektiv mätas då reaktorn är kall.[2]

    Enligt figur 10 är k-effektiv för CASMO-5M är högre i alla cykler i

    jämförelse med CASMO-4E.

    Figur 10 Oskarshamn 3. Cykel 5-31. k-effektivkurvor. CASMO-5M markeras

    med fyrkanter och CASMO-4E med svarta prickar.

    4.3.3 k-effektiv (kalla mätningar)

    I tabell 22 presenteras k-effektiv för de lokala kritiska mätningarna. Inom

    parentes presenteras medelvärdet av k-effektiv för cykel 21-31. Enligt

    tabell 22 är medelvärdet av standardavvikelsen för alla cykler är marginellt

    lägre i CASMO-5M än i CASMO-4E. Medelvärdet av k-effektiv för alla

    cykler försämras till 1,00202 i CASMO-5M mot CASMO-4E’s 1,00082.

    Vilket är 120 pcm högre i CASMO-5M jämfört med CASMO-4E.

    .

    CASMO-5M CASMO-4E

    k-medel 1,00202 (1,00167) 1,00082 (1,00203)

    Stdav (pcm) 110,82 (118) 111,18 (116)

  • Tabell 22 O3 – cykel 1-31 (cykel 21-31). Medelvärden av k-effektiv samt

    standardavvikelse.

    I figur 11 presenteras k-effektivkurvorna.

    Figur 11 Oskarshamn 3 för cykel 1-31 CASMO-5M markeras med fyrkanter och CASMO-4E med svarta prickar i graferna.

    Enligt figur 11 uppstår en tydlig trend. Vilken är att k-effektiv för

    CASMO-5M blir lägre än i CASMO-4E från cykel 21. Att enbart ta

    hänsyn till cykel 21 t o m 31 innebär att k-effektiv medelvärdet för dessa

    istället blir 1,00167 för CASMO-5M och 1,00203 för CASMO-4E. Det är

    36 pcm lägre i CASMO-5M jämfört med CASMO-4E. Anledningen till

    denna skillnad kan vara att ett nytt bränsle infördes vid cykel 21 (Optima2

    mot Optima).

    4.3.4 Voidens inverkan på k-effektiv

    När effekten i härden ändras, förändras void halten i reaktorn. Detta får

    dock inte påverka k-effektiv. Reaktiviteten per förändrad effektsprocent

    bör vara konstant i ett idealt fall, så att k-effektiv inte påverkas.[3]

    I tabell 23 presenteras k-effektiv i ”beginning of cycle” (BOC) samt ”end

    of cycle” (EOC).

    Värdena i tabell 23, som är en sammanfattning av tabell 24, visar

    skillnaden i k-effektiv (pcm) vid fulleffektsdrift jämfört med deleffektsdrift

    där reaktoreffekten styrts ned längs reglerlinjen. Lägre värden innebär att

    k-effektiv varierar mindre vid effektändringar, vilket är att eftersträva.

    Pcm/% representerar antalet pcm som skiljer emellan varje nedgången

    procent i reaktoreffekten. Noll pcm/% hade varit idealiskt men detta

    uppnås inte i praktiken pga komplexiteter i modellerna.

    Enligt tabell 23 och 24 varierar k-effektiv mindre i CASMO-5M än i

    CASMO-4E, mätt i pcm per förändrad effektsprocent, samt visar

    förbättringar genom minskningar på 1-2 pcm/% för samtliga block.

  • BOC Casmo-5M Casmo-4E EOC Casmo-5M Casmo-4E

    Cykel 20 110 141 98 134

    Pcm/proc 3 4 3 4

    Cykel 25 110 132 115 151

    Pcm/proc 3 4 3 5

    Cykel 29 106 140 100 137

    Pcm/proc 3 4 3 5

    Tabell 23 Sammanfattning av tabell 24.

    CASMO-5M / O3c20 EFPH K-eff Power % c20 EFPH K-eff Power %

    1785,7 1,00202 109,0 92,4 6786,5 1,00067 109,0 92,4

    1785,7 1,00092 75,0 53,44 6786,5 0,99969 75,5 53,44

    0,00110 0,00098

    0,00003 0,00003

    c25 EFPH K-eff Power % c25 EFPH K-eff Power %

    1031,2 1,00140 109,0 92,4 6770,6 1,00190 109,0 92,4

    1031,2 1,00030 75,5 53,44 6770,6 1,00075 75,5 53,44

    0,00110 0,00115

    0,00003 0,00003

    c29 EFPH K-eff Power % c29 EFPH K-eff Power %

    995,0 1,00204 109,0 92,4 5718,6 0,99587 109,0 92,4

    995,0 1,00098 75,0 53,44 5718,6 0,99487 75,5 53,44

    0,00106 0,00100

    0,00003 0,00003

    CASMO-4E / O3c20 EFPH K-eff Power % c20 EFPH K-eff Power %

    1785,7 1,00123 109,0 92,4 6786,5 0,99955 109,0 92,4

    1785,7 0,99982 75,5 53,44 6786,5 0,99821 75,5 53,44

    0,00141 0,00134

    0,00004 0,00004

    c25 EFPH K-eff Power % c25 EFPH K-eff Power %

    1031,2 1,00124 109,0 92,4 6770,6 1,00044 109,0 92,4

    1031,2 0,99992 75,5 53,44 6770,6 0,99893 75,5 53,44

    0,00132 0,00151

    0,00004 0,00005

    c29 EFPH K-eff Power % c29 EFPH K-eff Power %

    995,0 1,00063 109,0 92,4 5718,6 0,99493 109,0 92,4

    995,0 0,99923 75,0 53,44 5718,6 0,99356 75,5 53,44

    0,00140 0,00137

    0,00004 0,00004

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc

    Flöde % Flöde %

    Differens Differens

    Pcm/proc Pcm/proc Tabell 24. Detaljerad tabell för förändringen av effekten (pcm/%) vid förändrad

    effektsdrift för cykel 20, 25 och 29.

    4.3.5 Moderator temperatur koefficient – MTK

    MTK mäts i reaktivitet per grad förändring av moderator temperaturen

    (pcm/grad). Negativ MTK kan agera som ett inherent (naturlagsbaserat) säkerhetssystem. Negativ MTK medför undermoderering i härden, vilket gör

    att systemet självreglerande och icke skenande. En positiv MKT skulle göra

    systemet instabilt, där risken för torrkokning av bränslet blir hög.

    I CASMO-4E har man tidigare använt standardtemperaturmatrisen (S3C)

    som gör beräkningar vid temperaturerna 293 K, 393 K, 493 K respektive

    559 K, med THs tillägg vid 320 K, 360 K och 443 K. I CASMO-5M

  • användes den nya standardmatrisen (S3C) som ger beräkningar vid

    temperaturerna 293 K, 323 K, 375 K, 425 K, 475 K och 559 K. Därav

    hoppen i graferna i figur 14 för MTK vid olika temperaturer.

    Enligt tabell 25 är medelvärdet av MTK i cykeln lägre i CASMO-5M än i

    CASMO-4E.

    Medelvärde CASMO-5M CASMO-4E

    (pcm / grad C)

    BOC 3,32 4,04

    MOC 4,44 5,03

    EOC 6,08 6,68

    Tabell 25 O2 – cykel 34. Medelvärde av MTK för Oskarshamn 3.

    20 62 104

    27

    34

    41

    48

    55 69

    76

    83

    90

    97 111

    118

    125

    132

    139

    146

    153

    160

    167

    174

    181

    188

    195

    202

    209

    216

    223

    230

    237

    244

    251

    258

    265

    272

    279

    286

    -10

    -5

    0

    5

    10

    15

    MTK - O3

    BOC_C5M

    BOC_C4E

    grader Celsius

    diffe

    rens

    pcm

    /gra

    d

    20 80

    50 11026

    32

    38

    44 56

    62

    68

    74 86

    92

    98

    104 116

    122

    128

    134

    140

    146

    152

    158

    164

    170

    176

    182

    188

    194

    200

    206

    212

    218

    224

    230

    236

    242

    248

    254

    260

    266

    272

    278

    284

    -10

    -5

    0

    5

    10

    15

    MTK - O3

    MOC_C5M

    MOC_C4E

    grader Celsius

    diff

    ere

    ns

    pcm

    /gra

    d

    20 80

    50 11026

    32

    38

    44 56

    62

    68

    74 86

    92

    98

    104116

    122

    128

    134

    140

    146

    152

    158

    164

    170

    176

    182

    188

    194

    200

    206

    212

    218

    224

    230

    236

    242

    248

    254

    260

    266

    272

    278

    284-5

    0

    5

    10

    15

    20

    MTK - O3

    EOC_C5M

    EOC_C4E

    grader Celsius

    diff

    ere

    ns

    pcm

    /gra

    d

    Figur 14. Graferna ovan presenterar MTK i början (BOC), i mitten (MOC) och i

    slutet (EOC) av cykel 34 för O3. C4E står för CASMO-4E och C5M står för

    CASMO-5M. x-axeln representeras av temperaturen 20-286 grader Celsius.

  • 4.3.6 Isotermisk temperaturkoefficient – ITK

    Den isotermiska temperaturkoefficienten mäts i (k286C-k20C)/(286-20),

    vilken definieras som pcm/°C, vilket är förändringen i k-effektiv genom

    förändringen i vattnets temperatur.

    Enligt tabell 26 fås lägre ITK i hela cykeln för CASMO-5M.

    (k286C-k20C)/(286-20) CASMO-5M CASMO-4E

    [pcm/°C]BOC -0,00003 -

    0,00002

    MOC -0,00003 -0,00002

    EOC -0,00002 -0,00001

    Tabell 26 O3 – cykel 29. ITK i början, mitten samt i slutet av cykeln.

    Av figur 15 framgår att ITK är mindre positiv i CASMO-5M vid låga

    temperaturer och mer negativ vid temperaturer nära drifttemperaturen.

    Anledningen till hacken i kurvorna är okänd.

    20 40 60 80 100

    25

    30

    35 45

    50

    55 65

    70

    75 85

    90

    95 105

    110

    115

    120

    125

    130

    135

    140

    145

    150

    155

    160

    165

    170

    175

    180

    185

    190

    195

    200

    205

    210

    215

    220

    225

    230

    235

    240

    245

    250

    255

    260

    265

    270

    275

    280

    285

    1,01500

    1,01700

    1,01900

    1,02100

    1,02300

    1,02500

    1,02700

    1,02900

    ITK - O3

    BOC_C5M

    BOC_C4E

    grader Celsius

    k-e

    ffe

    ktiv

    20

    32

    44

    56

    68

    80

    92

    24

    28 36

    40 48

    52 60

    64 72

    76 84

    88 96

    100

    104

    108

    112

    116

    120

    124

    128

    132

    136

    140

    144

    148

    152

    156

    160

    164

    168

    172

    176

    180

    184

    188

    192

    196

    200

    204

    208

    212

    216

    220

    224

    228

    232

    236

    240

    244

    248

    252

    256

    260

    264

    268

    272

    276

    280

    284

    1,01600

    1,01800

    1,02000

    1,02200

    1,02400

    1,02600

    1,02800

    1,03000

    ITK - O3

    MOC_C5M

    MOC_C4E

    grader Celsius

    k-e

    ffekt

    iv

  • 20 80

    50 11026

    32

    38

    44 56

    62

    68

    74 86

    92

    98

    104 116

    122

    128

    134

    140

    146

    152

    158

    164

    170

    176

    182

    188

    194

    200

    206

    212

    218

    224

    230

    236

    242

    248

    254

    260

    266

    272

    278

    284

    1,00200

    1,00400

    1,00600

    1,00800

    1,01000

    1,01200

    1,01400

    ITK - O3

    EOC_C5M

    EOC_C4E

    grader Celsius

    k-e

    ffekt

    iv

    Figur 15. ITK kurvorna ovan presenterar k-effektiv i början (BOC) respektive i

    slutet (EOC) av cykel 32 för O1. Blå linje representerar CASMO-5M och den

    orangea CASMO-4E.

  • 4.3.7 Dämpkvotsberäkningar

    När en störning inträffar skall systemet kunna dämpa den. Dämpningen

    mäts i form förhållandet av amplituddämpningen från nuvarande samt

    föregående amplitud.

    Enligt tabell 27 ger CASMO-5M marginellt lägre dämpkvoter än

    CASMO-4E.

    BOC Casmo-5M Casmo-4E EOC Casmo-5M Casmo-4E

    Cykel 24 0,469 0,481 0,443 0,449

    Cykel 25 0,354 0,354 0,440 0,452

    Cykel 29 0,452 0,460 0,444 0,459

    Tabell 27 Dämpkvoter för cykel 29-32 i början resp. i slutet av cyklerna.

    4.3.8 Intern effekt i bränsleknippe av BA-stav

    För att undvika användning av styrstavar för sänkning av

    överskottsreaktiviteten i härden används s.k. brännbara absorbatorer.

    Dessa har den fördelen att de verkar jämnare än styrstavar och att deras

    verkan avtar allt eftersom utbränningen ökar och man får på så sätt en

    automatisk justering av reaktiviteten. Den nuklid som används är Gd-157 i

    form av dioxid.

    I tabell 28 presenteras effekten i bränsleknippet e23_2-4.p10. Effekten är

    relaterad till medeleffekten i knippet. Numreringen av bränslet beskriver

    höjdläget av knippet i härden. Värdena som presenteras i tabellen är alltså

    den utvecklade effekt i knippet. Där 1 är lika med 100 % och den differens

    ifrån 1 är den reducerade effekt som de brännbara absorbatorerna orsakat

    och därmed kompenserat en inskjutning av styrstavar.

    Enligt tabell 28 har CASMO-5M konsistent högre effekt i den studerade

    BA-staven i jämförelse med CASMO-4E, både vid 0 % och 80 % VOID.

    O3 CASMO-4E CASMO-5M CASMO-4E CASMO-5M

    0% VOID 0% VOID 80% VOID 80% VOID

    e23_2.p10 0,741 0,746 0,757 0,758

    e23_25.p10 0,727 0,731 0,752 0,752

    e23_3.p10 0,723 0,727 0,751 0,751

    e23_35.p10 0,726 0,730 0,755 0,755

    e23_4.p10 0,723 0,727 0,754 0,755

    Filnamn

    Tabell 28. Intern effekt i bränsleknippet e29 för olika voidhalter.

  • 4.3.9 Hastighet av BA-utbränningen

    BA-utbränningen bör ske kontinuerligt, så att effektfördelningen i övriga

    bränsleknippen inte störs.

    I figur 16 visas hur interneffekten utvecklas i bränsleknippet (e31_2-5.p10)

    av en BA-stav. Skillnaden är marginell men CASMO-5M har högre

    effektutveckling i bränslet i början av utbränningen i jämförelse med

    CASMO-4E. Detta leder också till att CASMO-5M har lägre effekt-

    utveckling i slutet av utbränningen i jämförelse med CASMO-4E. Detta

    kan ses i kurvorna ovan då den röda kurvan korsar den blåa.

    Figur 16. Ovan presenteras grafer över hastigheten av BA- utbränningen. De röda

    graferna representerar CASMO-5M och de blåa CASMO-4E.

  • 4.3.10 Inverkan av Xenon

    Xenonuppkomsten förgiftar reaktorn. Det innebär att reaktorns optimala

    drift störs. Det beror på att Xe-135 har ett stort absorptionstvärsnitt som

    innebär att xenon absorberar neutroner som är avsedda att leda till en

    fission och därmed minskar reaktiviteten i reaktorhärden.[2]

    Enligt figur 12 är skillnaderna är marginella. Dock ligger CASMO-4E

    konsistent högre än CASMO-5M i början av cykeln och omvänt i slutet av

    cykeln. Anledningen till detta är att i och med att CASMO-4E ligger högre

    i utbränningen i början så hinner xenonet att brinna ut snabbare än i

    CASMO-5M. Därmed får vi högre koncentration i slutet av

    effektändringen i CASMO-5M. Anledningen till hacken i kurvorna är

    okänd.

    1150

    1200

    1250

    1300

    1350

    1400

    1450

    1500

    1550

    Inverkan av Xenon - O3

    C4E_boc

    C5M_boc

    Tid efter effektändring

    mo

    lekyl

    er/

    cm

    ^3

    1100

    1150

    1200

    1250

    1300

    1350

    Inverkan av Xenon - O3

    C4E_eoc

    C5M_eoc

    Tid efter effektändring

    mo

    lekyl

    er/

    cm

    ^3

    Figur 17. Kurvan presenterar koncentrationen av Xenon efter effektändring. Den

    orangea kurvan representerar CASMO-5M och den blåa CASMO-4E.

  • 4.3.11 Fallande styrstav

    Styrstavar används för reglering av effekten samt för att stänga av en

    reaktor. En olycka som leder till att en styrstav som är långt inne i härden

    faller fritt ut ur härden, skulle kunna innebära ett kraftigt positivt

    reaktivitetstillskott. Detta kan leda till att vi får en prompt kritisk reaktor.

    Enligt figur 18 innebär mindre negativ bränsletemperatur- samt

    moderatortemperaturkoefficient i CASMO-5M i förhållande till CASMO-

    4E, till att högre reaktivitetstopp uppnås för CASMO-5M.

    Figur 18. Oskarshamn 3 - Fallande styrstav. Kurvorna som plottats i grafen är

    reaktiviteten (blå för CASMO-5M, röd för CASMO-4E),

    bränsletemperaturkoefficienten (rosa för C-5M, beige för C-4E),

    moderatortemperaturkoefficienten (grå för C-5M, grön för C-4E).

  • 4.3.12 Dopplerkoefficient

    Sannolikheten för en neutron att undkomma absorption under

    nedbromsning uttrycks med resonanspassagefaktorn, P. Denna faktor

    minskar (mäts i tvärsnitt, barns=10-24

    cm2) vid ökad temperatur. Minskar

    temperaturen, ökar faktorn men hamnar under ett mindre neutronenergin

    spektrum. Detta kallas även för dopplerfenomenet. Dopplerkoefficienten

    mäts i förändrad reaktiviet per grad celcius.

    I tabell 29 presenteras medelvärden av dopplerkoefficienten i början, i

    mitten samt i slutet av cykel 34. Dopplerkoefficienten i CASMO-5M är

    konsistent lägre än i CASMO-4E enligt tabell 29.

    Medelvärde CASMO-5M CASMO-4E

    (pcm/ °C)

    BOC -2,27 -2,11

    MOC -2,22 -2,07

    EOC -2,20 -2,05

    Tabell 29 O3 – cykel 29. Medelvärden av dopplerkoefficienten i början, mitten

    och i slutet av cykeln.

    I figur 19 presenteras grafer för dopplerkoefficienten för cykel 34 i O2 för

    BOC, MOC och EOC (beginning, middle och end of

    cycle).

    20

    30

    40

    50

    70

    90

    100

    140

    150

    170

    190

    200

    240

    250

    280

    286

    -2,75E+000

    -2,65E+000

    -2,55E+000

    -2,45E+000

    -2,35E+000

    -2,25E+000

    -2,15E+000

    -2,05E+000

    -1,95E+000

    -1,85E+000

    -1,75E+000

    Dopplerkoefficient - O3 (cykel 29)

    C5M_BOC

    C5M_MOC

    C5M_EOC

    C4E_BOC

    C4E_MOC

    C4E_EOC

    Temperatur (grad C)

    pcm

    /gra

    d C

    Figur 19. Kurvor för dopplerkoefficienten. CASMO-5M representeras av de nedre

    kurvorna (röd, mörkblå och gul) och CASMO-4E av de övre (brun, grön och

    ljusblå).

    4.3.13 Marginaler

    De marginaler som beaktas är främst CPR och LHGR. CPR används som

    en indikation på dryout i bränslet, dvs. att bränslet kokar torrt. LHGR mäts

    i kW/m används som en indikation på smältande bränsle, utsläpp av

    fissionsgaser samt mekanisk stress.

  • Enligt tabell 30 är marginalerna i CASMO-5M genomgående högre än i

    CASMO-4E. Resultaten innebär att marginalerna visat sig vara större än

    förväntat och därmed minskat risken för torrkokning av bränslet.

    Medelvärde CASMO-5M CASMO-4E

    CPR( %) 9,95 9,74

    LHGR( %) 18,39 17,93

    Tabell 30 O3 – cykel 1-31. Medelvärden av CPR (%) och LHGR (%).

  • 4.3.14 Isotoper

    De isotoper som beaktas i rapporten och förekommer i reaktorn är bl.a. U-

    235/236/237/238/239. Isotoper tyngre än U-235 och U-238 uppkommer

    genom neutroninfångning i kombination med radioaktiva sönderfall.

    Enligt figur 21-24 är skillnaderna marginella för U-235/236/238/239.

    Enligt figur 20 finns hälften så mycket U-237 i CASOM-5M än vad

    CASMO-4E uppvisar. Eftersom halten U-237 i en normal härd är så liten

    jämfört med U-235 (ca en tusendel) har detta ingen påvisbar påverkan på

    resultatet i beräkningarna.

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    26

    27

    28

    29

    30

    31

    32

    33

    34

    35

    36

    37

    38

    39

    40

    41

    42

    43

    44

    45

    46

    47

    48

    49

    50

    0

    5,00E+016

    1,00E+017

    1,50E+017

    2,00E+017

    2,50E+017

    3,00E+017

    3,50E+017

    4,00E+017

    4,50E+017

    C5M_U-237

    C4E_U-237

    Figur 20. U-237. Den blåa linjen är Casmo-5M och den orangea är Casmo-4E.

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    26

    27

    28

    29

    30

    31

    32

    33

    34

    35

    36

    37

    38

    39

    40

    41

    42

    43

    44

    45

    46

    47

    48

    49

    50

    0,00E+000

    1,00E+020

    2,00E+020

    3,00E+020

    4,00E+020

    5,00E+020

    6,00E+020

    7,00E+020

    8,00E+020

    9,00E+020

    C5M_U-235

    C4E_U-235

    Figur 21. U-235. Den blåa linjen är Casmo-5M och den orangea är Casmo-4E.

  • 1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    26

    27

    28

    29

    30

    31

    32

    33

    34

    35

    36

    37

    38

    39

    40

    41

    42

    43

    44

    45

    46

    47

    48

    49

    50

    0

    2,00E+019

    4,00E+019

    6,00E+019

    8,00E+019

    1,00E+020

    1,20E+020

    1,40E+020

    C5M_U-236

    C4E_U-236

    Figur 22. U-236. Den blåa linjen är Casmo-5M och den orangea är Casmo-4E.

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    26

    27

    28

    29

    30

    31

    32

    33

    34

    35

    36

    37

    38

    39

    40

    41

    42

    43

    44

    45

    46

    47

    48

    49

    50

    2,05E+022

    2,07E+022

    2,09E+022

    2,11E+022

    2,13E+022

    2,15E+022

    2,17E+022

    2,19E+022

    2,21E+022

    2,23E+022

    2,25E+022

    C5M_U-238

    C4E_U-238

    Figur 23. U-237. Den blåa linjen är Casmo-5M och den orangea är Casmo-4E.

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    26

    27

    28

    29

    30

    31

    32

    33

    34

    35

    36

    37

    38

    39

    40

    41

    42

    43

    44

    45

    46

    47

    48

    49

    0,00E+000

    2,00E+015

    4,00E+015

    6,00E+015

    8,00E+015

    1,00E+016

    1,20E+016

    C5M_U-239

    C4E_U-239

    Figur 24. U-239. Den blåa linjen är Casmo-5M och den orangea Casmo-4E.

  • 5 Redovisning av uppfyllda acceptanskriterier

    Här redovisas uppfyllda acceptanskriterier från [1].

    - Att k-effektivkurvorna ser rimliga ut och att k-effektiv är mellan 0,99 och 1,01.

    Uppfyllt och visas i figur 3, 7 respektive 11. Undantaget är

    cykel 14 för O1 med k-effektiv 1,019. De första cyklerna kan

    man dock bortse från eftersom de bygger på data från

    Polca-4 och jämvikt har ännu inte ställt in sig.

    - Att standardavvikelsen för kritiska mätningar är mindre än 300 pcm och att skillnaden i minvärde från cykel till cykel

    inte är större än 500 pcm.

    Standardavvikelsen < 300 pcm är uppfyllt med undantag av

    cykel 15 för O1, vilken man kan bortse från eftersom

    härduppföljningen inte uppnått jämvikt.

    Variation cykel till cykel < 500 pcm uppfylls.

    - Att TIP-avvikelserna både axiellt, radiellt och totalt under de fem senaste cyklerna är lägre än:

    Radiellt: 6 % för O1, 4 % för O2 och O3.

    Axiellt 10 % för O1, 7 % för O2 och O3.

    Totalt 11 % för O1, 8 % för O2 och O3.

    O1 Radiellt 4,1 %

    Axiellt 4,0 %

    Totalt 5,8 %

    O2 Radiellt 2,6 %

    Axiellt 5,2 %

    Totalt 5,8 %

    O3 Radiellt 3,5 %

    Axiellt 5,5 %

    Totalt 6,4 %

    Acceptanskriterierna uppfylls alltså.

    - Att vid visuell kontroll av enskilda TIP-sonder inga orimligheter i kurvornas form förekommer.

    Uppfyllt.

  • - Att marginalerna för CPR, TMOL och APLHGR inte skiljer mer än 5 procentenheter. Vid avvikelser ska det kunna

    förklaras.

    Alla marginaler har genomgåtts med scriptet

    ”kolla_marginal”. Förutom cykel 27 (APLHGR som sämst

    5,2 procentenheter), är avvikelsen mindre än 5 procent-

    enheter. Acceptanskriteriet uppfyllt.

    - Att intern effekt med Pin-Power Reconstruction inte skiljer mer än 5 % mot tidigare (kontrolleras med stickprov i några

    olika bränsletyper).

    Uppfylls. På kontrollerade bränsleknippen skiljer

    staveffekten uppemot 3,5 %.

    - Att intern effektfördelning inte skiljer mer än 5 % i 2D-programmet mot tidigare version. Kontrolleras med

    stickprov.

    Uppfylls. Staveffekten skiljer typiskt 0-0,7 %. Som mest vid

    hög utbränning.

    6 Slutsats

    Casmo-5M version 1.06.00 med biblioteket e7r0.125.586 i kombination

    med Simulate 6.07.23 ger totalt bättre resultat än Casmo-4E version

    2.10.00 med JEF 2.2 Update D i kombination med Simulate 6.07.23.

    I och med att Casmo-5M är så mycket kraftfullare och bredare än Casmo-

    4E har det även medfört att det krävs kraftfullare datakluster. Som det

    framgår av resultaten är det inga gigantiska skillnader programmen

    emellan. Dock innebär det inte att Casmo-5M inte är förbättrat. Snarare

    kan det innebära att man lättare kan detektera udda fall av incidenter då

    man har ett bredare och kraftfullare program att tillgå. En uppdatering till

    Casmo-5M medför att man så småningom kan uppdatera Simulate-3 till

    Simulate-5 som är kompatibelt endast med Casmo-5M och inte Casmo-4E.

    Samtliga acceptanskriterier i [1] är uppfyllda.

    7 Referenser

    [1] 2005-06820 Rutiner för validering och verifiering av

    beräkningsprogram för härdanalys inom THs verksamhets-

    område

    [2] Reaktorfysik, H1, Högre utbildning KSU

    [3] Termohydraulik för LWR-anläggningar

    [4] CASMO-55M.pdf

    [5] CASMO55M_codeAndLibraryStatus.pdf

    [6] SIMULATE.pdf

    [7] CMS_Link.pdf