valrom reinert ritz
DESCRIPTION
tevi si fitinguri de mari dimensiunniTRANSCRIPT
![Page 1: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/1.jpg)
Your partner for PE and PP
•••• pipeline fittings (standard & special fittings)
•••• hollow bars and solid rods
•••• construction of tools or machines
![Page 2: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/2.jpg)
• 1970 Mr. Reinert founded an engineer’s office for plastics technology in Radevormwald (approx 200 km in south from Nordhorn )
• 1992 Construction of a 2nd plant in Nordhorn
• 1995 Stop of plant in Radevormwald
• Since this date continuous extension of our program ���� building new halls
![Page 3: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/3.jpg)
1. Economical pipe fittings for gas and water supply applications
2. Large diameter for PE pressure systems
3. New products
• User friendly solutions
• Prefabricated manifolds
4. Welding or use of coupler? Comparison: butt welding, electro fusion sockets and push fit coupling
![Page 4: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/4.jpg)
Development of PE
50 Years PE pipesfor gas and water supply
• flexibility (pipes in variable lengths)
• resistance against corrosion
• safety, less damages cases
• easy laying (welding)
![Page 5: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/5.jpg)
gas supply:
•PE transport pipelines for gas are normally used until DN 200
•Some big cities until DN 350e.g. London (England) up to DN 600
![Page 6: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/6.jpg)
today DN 600 or even larger
-water supply:
PE up to DN 200 is more economicalthan cast iron (in the opinion some major
water companies)
![Page 7: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/7.jpg)
1. Economical pipe fittings for gas and water supply applications
2. Large diameter for PE pressure systems
3. New products
• User friendly solutions
• Prefabricated manifolds
4. Welding or use of coupler? Comparison: butt welding, electrofusionsockets and push fit coupling
![Page 8: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/8.jpg)
TEES DN 600 / d 710 mmin conformity to pressure class
AIRBUS HAMBURG
![Page 9: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/9.jpg)
AIRBUS Hamburg (Germany)Pipeline for the fire protection, 14 bar
(pressure test 21 bar acc. to DVS )
EXAMPLE
![Page 10: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/10.jpg)
TEES DN 600 / d 710 mmin conformity to pressure class
AIRBUS HAMBURG
![Page 11: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/11.jpg)
AIRBUS HAMBURG
![Page 12: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/12.jpg)
AIRBUS HAMBURGin conformity to pressure class
![Page 13: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/13.jpg)
EDEWECHT (Germany)PE100 d 710 mm SDR17
![Page 14: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/14.jpg)
EDEWECHT (Germany)Branche 45°d 710/500/500 mm (10 bar)
![Page 15: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/15.jpg)
Branche d900mm SDR17, 10bar, 45°
![Page 16: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/16.jpg)
VMW- d 900mm SDR17, 10 bar
Water company Antwerp (Belgium)
![Page 17: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/17.jpg)
Hydrostatic pressure Test Mitred tees, d 900mm SDR17
BECETEL
20°C, 15bar,
< 1h,
2pc. from 3pc.
failed
![Page 18: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/18.jpg)
VMW- d 900mm SDR17, 10 bar
Water company Antwerp (Belgium)
![Page 19: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/19.jpg)
BECETEL Belgien
Hydrostatic pressure Test
EN 12201-3
20°C, σσσσ 12,4 MPa,
100 h
80°C, σσσσ 5,5 MPa,
165 h
![Page 20: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/20.jpg)
1. Economical pipe fittings for gas and water supply applications
2. Large diameter for PE pressure systems
3. New products
• User friendly solutions
• Prefabricated manifolds
4. Welding or use of coupler? Comparison: butt welding, electrofusionsockets and push fit coupling
![Page 21: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/21.jpg)
EQUAL TEE d 355 mmINJECTION MOULDED
![Page 22: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/22.jpg)
EQUAL TEE d 355 mmINJECTION MOULDED
with 1 welded reducers
![Page 23: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/23.jpg)
EQUAL TEE d 355 mmINJECTION MOULDED
with 2 welded reducers
![Page 24: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/24.jpg)
EQUAL TEE d 355 mmINJECTIONMOULDED,
with welded reducers
Negativ example
![Page 25: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/25.jpg)
EQUAL TEE d 355 mmINJECTIONMOULDED,
with welded reducers
Negativ example
![Page 26: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/26.jpg)
R-R solution
REDUCED TEE d 355/90 mm
![Page 27: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/27.jpg)
���� more space saving
���� more stable
���� safer
���� lower in price
![Page 28: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/28.jpg)
HOLLOW BARS
![Page 29: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/29.jpg)
BASIC MODULE
![Page 30: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/30.jpg)
BASIC MODULE
long form flanged
![Page 31: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/31.jpg)
BASIC MODULE
differentother
possibilities
![Page 32: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/32.jpg)
reduction of project costs
- compact
- less fittings
- smaller manholes
- adaptable
![Page 33: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/33.jpg)
410 mm
DN 150
REDUCED TEEd 1200 mm / DN 150
![Page 34: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/34.jpg)
EQUAL TEE
![Page 35: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/35.jpg)
LONDONBritish Gas
![Page 36: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/36.jpg)
X-CROSS, with inspection opening
d500/355mm SDR11 Sewage system
![Page 37: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/37.jpg)
PP-TEE d630mm SDR9,7 with reinforcing ring
![Page 38: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/38.jpg)
d 560 mm
d 630 mm
d 710 mm
d 900 mm
PROFILE TEES NEW GENERATION
![Page 39: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/39.jpg)
![Page 40: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/40.jpg)
(HYDROSTATIC STRENGTH TEST)
TENSILE test, 25 bar
![Page 41: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/41.jpg)
Y-FITTINGS
![Page 42: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/42.jpg)
Y-FITTINGS
![Page 43: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/43.jpg)
1. Economical pipe fittings for gas and water supply applications
2. Large diameter for PE pressure systems
3. New products
• User friendly solutions
• Prefabricated manifolds
4. Welding or use of coupler? Comparison: butt welding, electrofusionsockets and push fit coupling
![Page 44: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/44.jpg)
On-site negativ example with standard flange DN 500/450 mm
![Page 45: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/45.jpg)
Submission request for proposal
practice example
Standard stub end with backing ring
PEsteel/ cast iron
SPECIAL FLANGE CONNECTION
internal misalignment
![Page 46: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/46.jpg)
PEsteel/ cast iron
Submission request for
proposal
practice
example
misalignment of screws
Standard stub end with backing ring
SPECIAL FLANGE CONNECTION
![Page 47: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/47.jpg)
steel/ cast iron PE
Standard stub end with backing ring Special flange connection
SPECIAL FLANGE CONNECTION
![Page 48: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/48.jpg)
SPECIAL FLANGE CONNECTION
![Page 49: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/49.jpg)
COST SAVING,smaller valvescan be used
![Page 50: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/50.jpg)
DN d
steel/cast iron PE
200 250 mm
250 315 mm*
300 355 mm
350 400 mm
400 450 mm
400 500 mm*
500 560 mm
500 630 mm*
600 710 mm*
700 800 mm*
800 900 mm*
900 1000 mm*
1000 1200 mm*
* special solution
Connection with identical internal widths of
PE-HD/PP pipe and steel cast iron fittings
SPECIAL FLANGE CONNECTION
![Page 51: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/51.jpg)
STANDARD backing ring connection
unloaded
![Page 52: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/52.jpg)
STANDARD backing ring connection
unloaded
![Page 53: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/53.jpg)
STANDARD backing ring connection
unloaded
![Page 54: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/54.jpg)
STANDARD backing ring connection
under pressure
![Page 55: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/55.jpg)
STANDARD backing ring connection
unloaded
![Page 56: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/56.jpg)
STANDARDbacking ring connection
under pressure
![Page 57: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/57.jpg)
expansion of pipetilting seal area
STANDARDbacking ring connection
under pressure
![Page 58: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/58.jpg)
![Page 59: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/59.jpg)
![Page 60: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/60.jpg)
tightness problems,
by means of
tilting of seal face of
standard stub ends
![Page 61: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/61.jpg)
Cut A-A
A
A
DN 50 - DN 600
alternatively to F-pieces and stub ends with backing rings
HP-FLANGE -
connection PE to accessories -
![Page 62: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/62.jpg)
HP-FLANGE, up to 25 bar
![Page 63: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/63.jpg)
HP-FLANGE, up to 25 bar
![Page 64: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/64.jpg)
HP-FLANGE
up to
25 bar
![Page 65: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/65.jpg)
a SAFE flange connection
needs as well
a
SAFE SEALING !
PROFILE GASKET
![Page 66: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/66.jpg)
PROFILE GASKET
![Page 67: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/67.jpg)
BROWN COALE EXTRACTION, ���� well
![Page 68: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/68.jpg)
DEEPNESS OF WELL > 100 mPE 100 d125-200 mm SDR11
![Page 69: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/69.jpg)
![Page 70: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/70.jpg)
Example: FREE FLOW X-CROSS for connection to hydrant
![Page 71: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/71.jpg)
1. Economical pipe fittings for gas and water supply applications
2. Large diameter for PE pressure systems
3. New products
• User friendly solutions
• Prefabricated manifolds
4. Welding or use of coupler? Comparison: butt welding, electrofusionsockets and push fit coupling
![Page 72: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/72.jpg)
OLD cast iron system
![Page 73: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/73.jpg)
![Page 74: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/74.jpg)
![Page 75: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/75.jpg)
City of HUSUM (North Germany)
![Page 76: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/76.jpg)
CAST IRON
![Page 77: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/77.jpg)
CAST IRON
![Page 78: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/78.jpg)
CAST IRON
![Page 79: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/79.jpg)
MANHOLE DN 2500 – Heilbronn (Germany)
![Page 80: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/80.jpg)
MANHOLE DN 2500 City of Heilbronn (Germany)
![Page 81: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/81.jpg)
MANHOLE DN 2500 – Heilbronn (Germany)
![Page 82: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/82.jpg)
DESULPHURISATION OF FLUE GAS
![Page 83: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/83.jpg)
DESULPHURISATION OF FLUE GAS
![Page 84: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/84.jpg)
DESULPHURISATION OF FLUE GAS
![Page 85: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/85.jpg)
DESULPHURISATION OF FLUE GAS
![Page 86: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/86.jpg)
DESULPHURISATION OF FLUE GAS
![Page 87: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/87.jpg)
DESULPHURISATION OF FLUE GAS
![Page 88: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/88.jpg)
DESULPHURISATION OF FLUE GAS
![Page 89: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/89.jpg)
1. Economical pipe fittings for gas and water supply applications
2. Large diameter for PE pressure systems
3. New products
• User friendly solutions
• Prefabricated manifolds
4. Welding or use of coupler? Comparison: butt welding, electro fusion sockets and push fit coupling
![Page 90: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/90.jpg)
- Push fit systems
CONNECTION: PE pressure pipe systems
- Butt-welding > DN 200
- Electro fusion < DN 300
![Page 91: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/91.jpg)
• pull resistant push fit coupler for PEpressure pipe systems up to 16 bar
• body of socket made of PE100-RC
• with GRIP elements made of technical plastics• Elastic mounted single elements • Lip seal, EPDM system 3S(drinking water quality - KTW approval)
• use: water - gas on request –
• advantages:- ring made of elastomer generates pre-loading- Profile ring repulses mud- simple installation due to push-fit system,- quick pipelaying (without cooling time)- no welding operators required- independent of the weather conditions,- no electric power supply required, - no welding and peeling machines required
DVGW-8616BUO210 registration
![Page 92: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/92.jpg)
NEW GRIP CONCEPT!
![Page 93: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/93.jpg)
NEW GRIP CONCEPT!
![Page 94: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/94.jpg)
Complete RANGE
![Page 95: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/95.jpg)
Pipe laying, Rhön-Maintal-Groupe
![Page 96: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/96.jpg)
FLANGED SOCKET
Repair of damaged large sized pressure pipeline (≥ 250 mm)
= use of REINOGRIP flanged socket
![Page 97: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/97.jpg)
FLANGED SOCKET
X
damage
![Page 98: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/98.jpg)
FLANGED SOCKET
removal of damaged pipe segment
![Page 99: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/99.jpg)
FLANGED SOCKET
![Page 100: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/100.jpg)
FLANGED SOCKET
X
X- 30 mm
![Page 101: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/101.jpg)
FLANGED SOCKET
![Page 102: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/102.jpg)
FLANGED SOCKET
![Page 103: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/103.jpg)
Traction test, d 315 SDR11
195 kN (conforms axial force of 25 bar pressure) and 1h
![Page 104: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/104.jpg)
Additional R-R standard fittings
• REDUCERS, concentric
• REDUCERS, eccentric
![Page 105: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/105.jpg)
Additional R-R standard fittings
• JOINING AND EXPANSION SOCKETS, as fixing point
• FIXED POINDS
• WALL DUCTS, pull resistant
![Page 106: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/106.jpg)
Additional R-R standard fittings
• WALL DUCTS,
watertight and pull-resistant
• TRANSITION PIECESPE / steel
• TRANSITION PIECESPE / cast iron
![Page 107: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/107.jpg)
Additional R-R standard fittings
• END CAPS, type 2,
(short form)
for big dimensions ≤ d 1000 mm
• PULLING HEADS ≤ d 1000 mm
![Page 108: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/108.jpg)
PULLING HEADSfor PE pipe relining
![Page 109: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/109.jpg)
(Projekt Suez Kanal)
Project Suez Kanal
Example: Pulling head d 900mm, traction 300 t
for horizontal sludge method ( HDD-method )
![Page 110: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/110.jpg)
New developments
![Page 111: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/111.jpg)
AIRBUS HAMBURG
Remember:
Gate valve cross,
without extension piece
![Page 112: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/112.jpg)
Adaptor and extension piece
- PE 100 – SDR 17/ 11
- DN 200 – DN 600 (- other dimensions on request-)
- consisting of: EU-piece with Tyton-gasket, internally enamelled,
bolts hot galvanized
- spigot sufficiently long for electrofusion welding or
other lengths on request
- Advantages: weldable on one end, one flange less = cost reduction,
easy installation, ���� adjusting +/- 40mm
Example: Airbus HamburgDN 600/710 mm, 16 bar
![Page 113: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/113.jpg)
TEE with inspection outletdiameter branch bigger than
diameter main pipe
![Page 114: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/114.jpg)
- PE 100 – SDR 17/ 11
- up to d 1600 mm
- branch with special flange connection
DN 250/ d 315 mm or as requested
- Advantages: - weldable
- homogeneous
TEE with inspection outlet
![Page 115: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/115.jpg)
![Page 116: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/116.jpg)
• Increasing trend to larger diameter for PE pressure systems
• Economic development of fittings(more stability, reduced costs)
• Design, construction and rating
PE and PP fully pressure rated large bore fittings,
design and practice examples
![Page 117: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/117.jpg)
MITRED TEE
![Page 118: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/118.jpg)
Pipe segments are cutted from standard pipes
Tees are welded from these segments in 2 steps
STEP 1 STEP 2 STEP 3
STANDARD large bore MITRED tees
![Page 119: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/119.jpg)
Pipe segments are cutted from standard pipes
Tees are welded from these segments in 2 steps
STEP 1 STEP 2 STEP 3
STANDARD large bore MITRED tees
![Page 120: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/120.jpg)
STANDARD large bore MITRED tees
Pipe segments are cutted from standard pipes
Tees are welded from these segments in 2 steps
STEP 1 STEP 2 STEP 3
![Page 121: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/121.jpg)
Hydrostatic pressure Test Mitred tees, d 900mm SDR17
BECETEL
20°C, 15bar,
< 1h,
2pc. from 3pc.
failed
![Page 122: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/122.jpg)
16 bar
8 bar≤ 10 bar
16 bar
based on:
PE100 pipe, SDR 11 ( Water/20°C/50 years) ����
Different statements about:
Resistance to internal pressure• reduced welding factor: 0,5 ����
• some manufacturers ����
• in many other regions: No reservation ! ����
Rule for design ofSEGMENTED tees
DIN 16963-5,
![Page 123: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/123.jpg)
Material : PE 100
SDR: 11
Pressure class: 16 bar
ISO-S: 5
Lifetime: 25a
Security factor: 1,25
1 = straight length of pipe, segmented bends ≤30°
2 = segmented bend > 30°and ≤ 90°
(R= 1,5xde) and equal tees 90°
3 = equal tee (branch) 60°
4 = equal tee (branch) 45°
20°C
PN 16
![Page 124: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/124.jpg)
Material : PE 100
SDR: 11
Pressure class: 16 bar
ISO-S: 5
Lifetime: 25a
Security factor: 1,25
1 = straight length of pipe, segmented bends ≤30°
2 = segmented bend > 30°and ≤ 90°
(R= 1,5xde) and equal tees 90°
3 = equal tee (branch) 60°
4 = equal tee (branch) 45°
20°C
PN 10
![Page 125: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/125.jpg)
STANDARD large bore MITRED tees
Pipe segments are cutted from standard pipes
Tees are welded from these segments in 2 steps
STEP 1 STEP 2 STEP 3
e < 10% DVS 2202-1 standard
![Page 126: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/126.jpg)
![Page 127: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/127.jpg)
ASME B31.3 standard : code requirement, piping design and construction
![Page 128: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/128.jpg)
ASME B31.3 standard : code requirement, piping design and construction
![Page 129: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/129.jpg)
ASME B31.3 standard : code requirement, piping design and construction
![Page 130: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/130.jpg)
ANOTHER ATERNATIVE= MADE OF PLASTICS
![Page 131: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/131.jpg)
PP-TEE d 630mm SDR 9,7 with reinforcing ring
![Page 132: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/132.jpg)
Forged Tees,
Steel solution,
and
PE or PP?
�
![Page 133: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/133.jpg)
d 560 mm
d 630 mm
d 710 mm
d 900 mm
PROFILE TEES NEW GENERATION
![Page 134: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/134.jpg)
Thank you very much for your attention.
![Page 135: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/135.jpg)
Discussion, some files.
![Page 136: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/136.jpg)
Infratech, Rotterdam
![Page 137: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/137.jpg)
![Page 138: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/138.jpg)
Welding machine, ≤ 2m
Welding machine, ≤ 2m
![Page 139: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/139.jpg)
Welding machine, ≤ 2m
Welding machine, ≤ 2m
![Page 140: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/140.jpg)
Welding machine, ≤ 2m
Welding machine, ≤ 2m
![Page 141: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/141.jpg)
![Page 142: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/142.jpg)
Bends
![Page 143: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/143.jpg)
Bends
![Page 144: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/144.jpg)
Bends
![Page 145: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/145.jpg)
![Page 146: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/146.jpg)
Transition piecePE – Cust Iron,
not pull resistent
![Page 147: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/147.jpg)
![Page 148: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/148.jpg)
![Page 149: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/149.jpg)
![Page 150: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/150.jpg)
Hatchbox, ≤ 4 bar
![Page 151: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/151.jpg)
Hatchbox, full pressure rated
![Page 152: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/152.jpg)
![Page 153: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/153.jpg)
![Page 154: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/154.jpg)
![Page 155: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/155.jpg)
Quality management system
![Page 156: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/156.jpg)
Quality management system
![Page 157: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/157.jpg)
Quality management system
![Page 158: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/158.jpg)
Quality management system
![Page 159: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/159.jpg)
Nuclear power station, pumphouse
![Page 160: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/160.jpg)
Nuclear power station, pumphouse
![Page 161: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/161.jpg)
![Page 162: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/162.jpg)
![Page 163: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/163.jpg)
![Page 164: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/164.jpg)
CO2 Reduction in Mongstad/ NORGE
![Page 165: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/165.jpg)
![Page 166: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/166.jpg)
![Page 167: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/167.jpg)
![Page 168: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/168.jpg)
Thank you very muchfor your attention.
![Page 169: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/169.jpg)
Overview / HALL PLAN
Position
Gruppe 2
![Page 170: Valrom Reinert Ritz](https://reader031.vdocuments.net/reader031/viewer/2022012406/55cf926d550346f57b967076/html5/thumbnails/170.jpg)
HP-SC Flange, stress compensation