Page 1: VariAx Clavicle - az621074.vo.msecnd.netaz621074.vo.msecnd.net/syk-mobile-content-cdn/global-content-system/... · 940020 Silicon Mat for Instrument Insert (Spare Part) 940021 Silicon

System Components GuideVariAx® Clavicle

Str

yker

Pla

ting

Page 2: VariAx Clavicle - az621074.vo.msecnd.netaz621074.vo.msecnd.net/syk-mobile-content-cdn/global-content-system/... · 940020 Silicon Mat for Instrument Insert (Spare Part) 940021 Silicon

2

All non-sterile products may be ordered sterile by placing an “S” at the end of the REF Number.

*Sterile Packed Only - Special Order

System Components – Implants

REF Plate Length Left Right mm Holes

Standard Plates

628006 628026 75 6

628007 628027 88 7

628008 628028 99 8

628010 628030 122 10

Bridge Plates

628046 628066 99 6

628048 628068 122 8

REF Plate Length Left Right mm Holes

Standard Plates

628108 628128 97 8

628110 628130 120 10

Bridge Plates

628146 628166 97 6

628148 628168 120 8

REF Plate Length Shaft Left Right mm Holes

628203 628223 74 3

628204 628224 86 4

628205 628225 98 5

628207 628227 122 7

628209S* 628229S* 144 9

SUPERIOR MIDSHAFT PLATES DECREASED CURVATURE

SUPERIOR MIDSHAFT PLATES INCREASED CURVATURE

SUPERIOR LATERAL PLATES

Page 3: VariAx Clavicle - az621074.vo.msecnd.netaz621074.vo.msecnd.net/syk-mobile-content-cdn/global-content-system/... · 940020 Silicon Mat for Instrument Insert (Spare Part) 940021 Silicon

3

System Components – Implants

Plate Length REF mm Holes

628306 75 6

628307 86 7

628308 97 8

628310 118 10

ANTERIOR MIDSHAFT PLATES

Plate Length REF mm Holes

628406 59 6

628407 72 7

628408 83 8

ANTERIOR LATERAL PLATES

All non-sterile products may be ordered sterile by placing an “S” at the end of the REF Number.

REF Plate Length Left Right mm Holes

12mm Hook Depth

628505S 628515S 68 5

628506S 628516S 79 6

628507S 628517S 90 7

628509S 628519S 111 9

16mm Hook Depth

628525S 628535S 68 5

628526S 628536S 79 6

628527S 628537S 90 7

628529S 628539S 111 9

20mm Hook Depth

628545S 628555S 68 5

628546S 628556S 79 6

628547S 628557S 90 7

628549S 628559S 111 9

LATERAL HOOK PLATES*

Page 4: VariAx Clavicle - az621074.vo.msecnd.netaz621074.vo.msecnd.net/syk-mobile-content-cdn/global-content-system/... · 940020 Silicon Mat for Instrument Insert (Spare Part) 940021 Silicon

4

System Components – Screws

2.7MM LOCKING SCREWS, SELF TAPPING 2.7MM BONE SCREWS, SELF TAPPING

Titanium Length REF mm

614508 8 614510 10 614512 12 614514 14 614516 16 614518 18 614520 20 614522 22 614524 24 614526 26 614528 28 614530 30 614532 32 614534 34

Titanium Length REF mm

614708 8 614710 10 614712 12 614714 14 614716 16 614718 18 614720 20 614722 22 614724 24 614726 26 614728 28 614730 30 614732 32 614734 34

3.5MM LOCKING SCREWS, SELF TAPPING 3.5MM BONE SCREWS, SELF TAPPING

Titanium Length REF mm

614608 8 614610 10 614612 12 614614 14 614616 16 614618 18 614620 20 614622 22 614624 24 614626 26 614628 28 614630 30 614632 32 614634 34

Titanium Length REF mm

614808 8 614810 10 614812 12 614814 14 614816 16 614818 18 614820 20 614822 22 614824 24 614826 26 614828 28 614830 30 614832 32 614834 34

All non-sterile products may be ordered sterile by placing an “S” at the end of the REF Number.

Page 5: VariAx Clavicle - az621074.vo.msecnd.netaz621074.vo.msecnd.net/syk-mobile-content-cdn/global-content-system/... · 940020 Silicon Mat for Instrument Insert (Spare Part) 940021 Silicon

5

2.7MM BONE SCREWS, SELF TAPPING

3.5MM BONE SCREWS, SELF TAPPING

System Components – Instruments

REF Description

703701 2.0mm Drill AO connection for use with 2.7mm screws

703702 2.6mm Drill AO connection for use with 3.5mm screws

703703 2.7mm Overdrill with AO connection for use with 2.7mm screws

703704 3.5mm Overdrill with AO connection for use with 3.5mm screws

703705 Tap with AO connection for 2.7mm screws

703706 Tap with AO connection for 3.5mm screws

45-80040 Countersink for Screws 2.7/3.5mm

703824 220mm Long 2.6mm Drill AO connection for use with 3.5mm screws

DRILLS, TAPS AND COUNTERSINK

All non-sterile drills may be ordered sterile by placing an “S” at the end of the REF Number.

REF Description

703713 T10 Screwdriver Blade - AO Fitting

703667 T10 Screwdriver Blade AO - Self Retaining

703825 180mm T10 Screwdriver Blade AO - Self Retaining

703714 VariAx Screwdriver Handle

702428 Elastosil Handle (Teardrop form with AO Coupling)

703715 Screw Holding Sleeve

45-35002 Depth Measuring Gauge

703820 Polyaxial and Compression Drill Guide for 2.0mm Drills and 2.0mm K-Wire

703826 Polyaxial and Compression Drill Guide for 2.6mm Drills

703710 Overdrill Guide for 2.7mm and 3.5mm Drills

703818 2mm Kirschner Wire with Stop

390164 1.6mm Kirschner Wire

390192 2.0mm Kirschner Wire

702905 Bending Irons

703816 Aiming Block for Left Superior Lateral Plate

703817 Aiming Bock for Right Superior Lateral Plate

703823 Joystick for Aiming Block

BONE REDUCTION INSTRUMENTS

GENERAL INSTRUMENTS

REF Description

700669 Periosteal Elevator and Ball Spike

702926 Small Reduction Clamp

702932 Repositioning Forceps (Lobster Claw)

702944 Repositioning Forceps Jaw: Ballspike

703716 K-Wire Clamp

703821 Plate Holding Clamp

703822 Straight Reduction Clamp

700667 Hohmann Retractor 15mm

Page 6: VariAx Clavicle - az621074.vo.msecnd.netaz621074.vo.msecnd.net/syk-mobile-content-cdn/global-content-system/... · 940020 Silicon Mat for Instrument Insert (Spare Part) 940021 Silicon

6

System Components – Trays

REF Description

940010 Insert for Superior Plates

940011 Insert for Anterior Plates

940014 Insert for Reduction Instruments

940015 Insert for VariAx Instruments

940016 Screw Rack

940018 2/3 Generic Tray Insert

940013 Plate Trial Insert

940019 Elbow Add-On Insert

940020 Silicon Mat for Instrument Insert (Spare Part)

940021 Silicon Mat for 1/3 Generic Insert (Spare Part)

940022 Silicon Mat for 2/3 Generic Insert (Spare Part)

940026 Silicon Mat for Anterior Plate Insert (Spare Part)

940023 1 Level Tray

940024 2 Level Tray

TRAYS AND INSERTS

Page 7: VariAx Clavicle - az621074.vo.msecnd.netaz621074.vo.msecnd.net/syk-mobile-content-cdn/global-content-system/... · 940020 Silicon Mat for Instrument Insert (Spare Part) 940021 Silicon

7

System Components – Plate Trials

SUPERIOR MIDSHAFT TRIALS DECREASED CURVATURE

SUPERIOR LATERAL TRIALS

ANTERIOR MIDSHAFT TRIALS

ANTERIOR LATERAL TRIALS

SUPERIOR MIDSHAFT TRIALS INCREASED CURVATURE

REF Plate Length Left Right mm Holes

703830 703834 75 6

703831 703835 88 7

703832 703836 99 8

703833 703837 122 10

REF Plate Length Left Right mm Holes

703850 703854 74 3

703851 703855 86 4

703852 703856 98 5

703853 703857 122 7

Plate Length REF mm Holes

703860 75 6

703861 86 7

703862 97 8

703863 118 10

Plate Length REF mm Holes

703865 59 6

703866 72 7

703867 83 8

REF Plate Length Left Right mm Holes

703840 703842 99 8

703841 703843 122 10

Page 8: VariAx Clavicle - az621074.vo.msecnd.netaz621074.vo.msecnd.net/syk-mobile-content-cdn/global-content-system/... · 940020 Silicon Mat for Instrument Insert (Spare Part) 940021 Silicon

8

System Components – Trials

LATERAL HOOK TRIALS REF Plate Length Left Right mm Holes

12mm Hook Depth

703870 703871 68 5

16mm Hook Depth

703872 703873 68 5

20mm Hook Depth

703874 703875 68 5

REF Description

703876 Hook Plate Trial Ruler

Page 9: VariAx Clavicle - az621074.vo.msecnd.netaz621074.vo.msecnd.net/syk-mobile-content-cdn/global-content-system/... · 940020 Silicon Mat for Instrument Insert (Spare Part) 940021 Silicon

9

Notes

Page 10: VariAx Clavicle - az621074.vo.msecnd.netaz621074.vo.msecnd.net/syk-mobile-content-cdn/global-content-system/... · 940020 Silicon Mat for Instrument Insert (Spare Part) 940021 Silicon

10

Notes

Page 11: VariAx Clavicle - az621074.vo.msecnd.netaz621074.vo.msecnd.net/syk-mobile-content-cdn/global-content-system/... · 940020 Silicon Mat for Instrument Insert (Spare Part) 940021 Silicon

11

Notes

Page 12: VariAx Clavicle - az621074.vo.msecnd.netaz621074.vo.msecnd.net/syk-mobile-content-cdn/global-content-system/... · 940020 Silicon Mat for Instrument Insert (Spare Part) 940021 Silicon

This document is intended solely for the use of healthcare professionals. A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery.

The information presented is intended to demonstrate a Stryker product. A surgeon must always refer to the package insert, product label and/or instructions for use, including the instructions for Cleaning and Sterilization (if applicable), before using any Stryker product. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area.

Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: Stryker, VariAx. All other trademarks are trademarks of their respective owners or holders.

The products listed above are CE marked.

Content ID: VAX-SCS-3 Rev 1, 11-2015

Copyright © 2015 Stryker

Manufactured by:

Stryker GmbHBohnackerweg 12545 SelzachSwitzerland

www.stryker.com

0123