2

Two emission test chambers withstandard test space sizes of 200and 1000 litres are available. Anideal practically oriented solution.

Special sizes on request.

Requirements/fulfilment

Environmental test equipment to characterize ...

Materials can be affected by envi-ronmental influences. However,under these influences, the mate-rials can be harmful to the environ-ment also, e.g. by emissions fromthe materials into the air.

These emissions are particularlyrelevant in closed rooms. They canaffect other available materials andof course also human beings.

The relevant factors and their effecton the emission behaviour of mate-rials in connection with suitablemeasuring methods can be usedto evaluate emission together withthe Vötsch chamber.

Analytical investigations, systemcalibration and olfactometric stu-dies are possible with suitablemeasuring equipment.

Volatile organic compounds (VOC)from indoor materials and productsare determined under practicalconditions.

Scientific measurement and pro-duct testing aimed to limit organicemissions indoors, for the purposeof improved consumer protection,can be evaluated.

Exposure to indoor air pollutioncaused by volatile organic com-pounds (VOC) must be furtherreduced resp. indoor air qualityimproved - for several reasons:

l An increased use of polymerhydrocarbon compounds inindoor materials and productsresults in a growing numberof emitting sources

l Energy saving insulation reducesthe ventilation rates in buildingswhich leads to an accumulationof pollutants indoors

l Reduction of the environmentalpollution of technical devices(greenhouse effect, ozone layerdepletion)

The technical requirements of theenvironmental test equipmentwere defined by specialists fromindustry and science and thensuccessfully put into practice:

l A test equipment with a low emission (purity in molecularrange)

l Excluding contaminations fromthe vicinity

l Particle measurementl Minimizing adsorption effectsl High desorption temperatures

( > 200 °C)

l High parameter accuracyl Ventilationl Tests with and without air

exchangel Standard analytical equipment

can be usedl Networking and documentation

possible

l Modern people spend about90 % of their time indoors

l Increased sensibility of the hu-man organism to the influenceof minute concentrations

3

Testing of all consumer productsand materials indoors, passengercars, electronic equipment, varnish,dyes, modern objects of utility andall types of clothing.

Possiblefields of application

l Test houses and research

l Automotive industry

l Electronics industry

l Aviation and space industries

l Plastic processing industries

l Clothing industry, manufacturesof sports articles

l Chemical industry

l Paints and coatings

l Building material industry

... volatile organic compounds

Following investigations can be conductedwith suitable measuring equipment

l Qualitative analysisl Quantitative analysisl Adsorption effects analysis

of the walls

l Recovery rates analysisl System calibrationl Olfactometrie

Application in manybranches ...

4

Test Standards

Extract of trade specific test standards / test methods

l Automotive industrye.g. VDA 276, GS 97014-2 ...

l Building materials, interior fitting items, furnituree.g. ISO 16000-9 ...

l Building products, furnishingse.g. prEN 13419-1 ...

l Electric devices, electronic equipment, HiFi, TV, Video, DVD, ...e.g. ECMA-328 ...

l Floor coverings, interior fittings, furnishingse.g. prEN 15052, GEV ...

l Wood-based productse.g. ASTM D ...

l Interior fitting, furnishinge.g. ASTM D ...

5

... Technical Data

Basic equipment

l Test space stainless steel,electro polished and pressureproof to ± 10 mbar

l Air-jacket conditioningl Carrier gas conditioning for

climatel Carrier gas massflow control

via massflow controllerl Desorption and rinsing

procedurel Special ventilation with a dry

mounted magnetic clutchl Connection for discharging

quantities of gas for analysisl Entry port septuml Water storage container

(humidification water) ofstainless steel with automatic

water replenishmentl Microprocessor control

and monitoring systeml Colour touchpanel

Options and user-specificsolutions on request.

Admissible ambient conditions: temperature +15 °C to +35 °C, humidity max. 75 %, max. dew point +20 °C - 1) measured in the middle oftest space, 2) relative to the set value, 3) in accordance with IEC 60068-3-5, 4) measured 1 m distance from the front and in 1.6 m height atfree field measurement according to EN ISO 11201.We reserve the right of changes in construction resulting from technical progress. Some of the illustrated systems contain optional extras.

Technical Data

Type VCE 200 VCE 1000Test space volume (useful) l 240 (208) 1000 (916)Carrier gas purified compressed air, on-sitePerformance range for temperature testingConditioning air jacket principleTemperature range °C +20 to +130Temperature deviation in time 1) K ±0.1 to ±0.3 Temperature homogeneity in space 2) K ±0.5 Temperature rate of change 3)

Cooling K/min 0.3 0.3Heating K/min 1.0 0.4Performance range for climate testingConditioning Carrier gas conditioning with climatic

modul with evaporation systemTemperature range °C +20 to +130Humidity range % 5 to 95Dew point range °C +5 to +60Humidity deviation in time % ±1 to ±3Carrier gas exchange rate 0.1 to 1.8 chamber volume per hourConditions of carrier gas min. +10 °C / 50 % RH

max. +32 °C / 80 % RHPerformance range for desorptionTemperature of desorption up to max. +240 °C, adjustableTest space surface temperature between +220 °C and +240 °CRinsing procedure max. 4 m3/hDimensions test space Width mm 610 750

Depth mm 610 1630Height mm 560 750

Test space door mm 530 x 520 670 x 670External dimensions Width mm 1250 1350

Depth mm 1700 2950Height mm 2350 2050

Sound pressure level 4) dB(A) 61 63Rated power kW 9,0 10,0Electrical connection 3/N/PE AC 400 V ± 10 %, 50 Hz

6

Comfortable, user-friendly operation ...

Computer Integrated ControlOur test chambers are equippedwith an integrated industrial com-puter system with a 8" colourtouchpanel to facilitate operation,monitoring and documentation.

Control is governed by the 32 BitI/O system with integrated softPLC. A web server can place testand diagnosis information in theintranet via Ethernet if desired.

Online-ServiceThe units have an online servicefunction, enabling our specialists toestablish an online data link to theunit via internet or mobile telepho-ne. The online link provides ourexperts with all the data they re-quire.

Remote control and monitoringSafe operation of the overall sys-tem requires the test cabinet to bereliably integrated. Enables, warn-ing messages and fault signals aredefined in a safety matrix with thecustomer and the safety officers.

Units can be reached and control-led from practically anywhere in theworld by simply accessing the unitwebserver in the intranet via thenetwork or enabling in the internet.

NetworkingCompatible with S!MPATI*software package

Technical Datal Touch screen 800 x 600 pixell Multilingual software

Interfacesl Ethernet 100/10 megabitl RS 232 (Option)l USB for stick

Customer inputs/outputsl 4 potential-free outputs for

test specimen controll 4 inputs (24 V DC)

Options

Our software S!MPATI* dictatesthe optional operating parametersfor system and test samples. Thissoftware, just like known Windowsstandards, can also be integratedinto networks.

Operation of the test system issimple and time-saving. Integratedmonitoring routines makes for morereliable system operation. The eva-luation and documentation of testcycles as well as the integration ofspecial measuring data guaranteesa higher quality standard.

Additional measuring technologyl Independent temperature and

humidity measuring

USB-Stickl For external saving of measuring

data

7

VCE 1000 classic

Ascertaining volatile organic emissions VOCfrom interior components of motor vehicles, door coverings, dashboards, head covering

... Examples for application

Test space volume 1000 litreTemperature range +20 °C to +130 °CHumidity range 30 to 95 % RHDesorption +240 °C

VCE 200

Ascertaining volatile organic emissions VOCfrom small assemblies, samples, etc. for interior components of motor vehicles

Test space volume 200 litreTemperature range +20 °C to +130 °CHumidity range 30 to 95 % RHDesorption +240 °C

including equipment package to‘Test methods’ Automotive

including equipment package to‘Test methods’ Automotive

l Globe valvel Reinforced test space container ±0.1 barl Optimized cooling and heating performancel Volume compensation Tedlar-bagl FID measuring gas extraction / feed backl Adjustable circulating air quantity

l Globe valvel Reinforced test space container ±0.1 barl Optimized cooling and heating performancel Volume compensation Tedlar-Bagl FID measuring gas extraction / feed backl Adjustable circulating air quantity

8

VCE 1000/S

Test space volume approx. 1000 litreTemperature range +20 °C to +130 °CHumidity range 30 to 95 % RHDesorption +240 °C

Examples for application ...

including equipment package to‘Test methods’ Automotive

and additional

Ascertaining volatile organic emissions VOCfrom interior components of motor vehicles

l Highly modified test space container withspecial entry ports

l Connection to energy storage testerl Customised „Safety device“ energy storage

Further additional accessories

l Globe valvel Reinforced test space container ±0.1 barl Optimized cooling and heating performancel Volume compensation Tedlar-Bagl FID measuring gas extraction / feed backl Adjustable circulating air quantity

Emission analysis of energy storages,accumulators, ...

l Distribution system for taking samplesl Adjustable circulating air quantityl Measuring sensor for humidity measurementl Emission-free port hole with external located socket

9

VCE 5000/S

Test space volume approx. 5000 litreTemperature range +20°C / +130 °CHumidity range 30 to 95 % RHDesorption +240 °C

Ascertaining volatile organic emissions VOCfrom motor compartment of a motor vehicle

including equipment package to‘Test methods’ Automotive

and additional

l Safety device for avoiding an explosionl Safety concept with external sensorsl UEL-monitoring for air jacket systeml Measuring sensor with intrinisically safe measuring

circuit

Further additional accessories

... Examples for application

l Insert cabinet with reinforced floor load 850 kgl Distribution system for taking samples

Equipment for uninterrupted power supply

Ascertaining VOC from motor compartment, com-plete engine block with gearing (and tank)

l Globe valvel Reinforced test space container ±0.1 barl Optimized cooling and heating performancel Volume compensation Tedlar-Bagl FID measuring gas extraction / feed backl Adjustable circulating air quantity

10

Examples for application ...

Test space volume approx. 8000 litreTemperature range +20 °C to +130 °CHumidity range 30 to 95 % RHDesorption +240 °C

VCE 8000/S

including equipment package to Building materials ISO 16000-9Electric devices ECMA

11

The introduction of the Euro VI andEuro V emission regulations requirestringent tests of vehicle emissions.

The temperature and climatic con-trolled SHED chambers fromVötsch comply with the latest

These chambers are hermeticallysealed and use volume compensa-tion bags to accommodate tests atvarious temperatures without pres-sure equalisation respective to theatmosphere.

European and US standards.Protecting your investment nowand in the future …

SHED chambersfor any application

RL-SHED to determine the fuelemission of a vehicle while driving.

ORVR-SHED to determine the fuelemission while refuelling a vehicle.

VT-SHED in accordance with regu-lations such as CARB, EPA andEU.

Emission Test Chambers for Euro VI and better

Global Service Support

Quality Weiss Technik North America, Inc. helps make the task of compliance with the QS9000 3rd Edition Calibration Mandate much simpler. There is no need for you to take the time to actively seek an accredited laboratory.

Weiss Technik North America, Inc., certified ISO9001 in 1997, can provide the latest required ISO/IEC 17025 (A2LA accredited) calibration services at your facility. These services meet 17025 requirements and ensure that your company is in compliance with the most recent changes in the QS9000 3rd Edition mandate.

Please contact us for a copy of our Certificate of Accreditation and a copy of our Calibration Scope of Accreditation.

Weiss Technik NorthAmerica, Inc. CalibrationServices are accreditedby A2LA to ISO/IEC 17025

24/7 Helpline:1-800-361-6731

Our products are backed by our 24/7 global factory trained service department. With over 400 service technicians located throughout the globe, we offer our customers a wide variety of services including the following:

• 24/7 Service Helpline • Preventive Maintenance Program• Chamber Start-Up• Installations• Emergency Service• Technical Support• Service Agreements• Spare Parts & Materials • Instrument and Chamber Calibrations per ISO 17025• Chamber Diagnostics, Troubleshooting and Evaluations• Refrigeration Upgrades and Retrofits• Refrigerant Removal and Disposal• Controller and Instrument Upgrades and Retrofits• Chamber Modifications• Equipment Relocations• Training on Proper Equipment Use and Programming• Used Equipment• Rental Programs• Extended Warranty• Service on all Makes and Models

Weiss Technik North America, Inc.3881 N. Greenbrooke Dr. SEGrand Rapids, MI 49512 USA(616) 554-5020 • Fax: (616) 554-5021www.weiss-na.com24/7 Service Support Helpline: 1-800-361-6731

Global Partner for Environmental Test Chambers

Weiss Technik NorthAmerica, Inc. QualitySystem is registered toISO9001:2008

Weiss Technik NorthAmerica, Inc. CalibrationServices are accreditedby A2LA to ISO/IEC 17025

Weiss Technik North America, Inc. Quality System is registered to ISO9001:2008

EmissionsVOC/WTNA JAN 2017