Page 1: Vector PC - Compulite

Vector PC

Page 2: Vector PC - Compulite

Copyright © 2008 Compulite Systems (2000) Ltd. All rights reserved. This documentation is delivered subject to the following conditions and restrictions:This document is protected by copyright and distributed under licenses restricting its use, copying, distribution and decompilation. No part of this product or document may be reproduced in any form by any means without the prior express written authorization of Compulite Systems (2000) Ltd. and its licensors (if any). The content of this document is furnished for informational use only and is subject to change without notice. Compulite Systems (2000) Ltd. assumes no responsibility or liability for errors or inaccuracies that may appear in this book.

Document Version

Version 1.0 ; March 2008

Page 3: Vector PC - Compulite

Table of Contents

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Vector PC software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Installing Vector PC software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Using Vector PC software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Display layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Remote Editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Device Builder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Vector PC and output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Vector PC and visualizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Master/Slave with Vector PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Connecting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

ASCII equivalents for console keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Page 4: Vector PC - Compulite

1

OverviewVector PC offers full functioning Vector software that can be used with visualizer applications to design and edit your show offline. When connected to ePort for DMX-over-Ethernet output, Vector PC can be used to run the show, as a back up console, or configured as a slave console. When used with eSynch, Vector PC offers MIDI and SMPTE options. All outboard devices, such as Vector wings and iControl can be connected via the Ethernet connection. Vector PC software includes online help files that are updated with each software release.

Requirements:

PC running Windows 2000 or Windows XP

Pentium 4 and higher (or equivalent)

150 MB free memory

512 RAM memory

Vector PC softwareVector PC software includes a number of components:

Real-time Components - the RT interface and RT Vector PC

Device Builder - A utility for defining device personalities

Remote Editor - A utility that allows you to take over editing operations on the console

Vector PC - Vector application software main window

Vector PC panel - A console panel simulator

Figure 1: Vector PC components as seen in the PC’s Start menu Program Files

Installing Vector PC softwareIf you are upgrading your current Vector PC software make sure to save a backup copy of the Vector Shows folder and any customized devices you have added in the Device Builder.

IMPORTANT! If Vector PC is already installed on your computer, uninstall the applica-tion before upgrading the software.

When Vector PC is running, Real-Time icons appear on the Windows task bar. Mousing over the icons displays the version current number and the PC’s IP address.

Page 5: Vector PC - Compulite

2

CompuliteVector PC software

Figure 2: Real-Time icons on the task bar

To install Vector PC

1 Download Vector PC software from the Compulite web site, www.Compulite.com.

2 Run Vector Setup.###.exe.

The installation wizard begins.

3 On the first screen, click NEXT.

4 Read the License Agreement and click YES.

5 On the Information window, click NEXT.

6 On the Setup type window, choose VECTOR PC.

7 Click NEXT until the installation progress bar appears.

If you have not selected a different location the Vector PC software is installed in C:\Program Files\Compulite\Vector Pc.

Note: Release Notes are included in the software version package. Acrobat Reader is needed to open the Release Notes.

8 When the installation is complete, click FINISH.

To run Vector PC

Run the Vector PC program from your PC’s Start menu Compulite Vector PC or from the desktop shortcut.

On start up (assuming you are using one monitor), the Vector main window and the PC panel are displayed.

ATTENTION! After upgrading the Vector PC software, run the application and check if your customized System Settings options (operation mode, programming syntax, hard-ware, etc.) have changed.

To shut down Vector PC

Click FILE and choose EXIT.

Exiting the application shuts down Real-Time interface, RT.exe, gc console, and all open panels.

RT Interface Version #IP = #Vector RT Version #

Page 6: Vector PC - Compulite

3

VectorUsing Vector PC software

Using Vector PC softwareProgramming a show on Vector PC is essentially identical to operating a Vector console. You can configure the main window to suit the single monitor configuration or copy a layout file from the Vector console.

Figure 3: Vector PC panel with Playback Control enabled

The Vector panel contains functional representations of:

Under the Application menu, you can:

Show or hide a playback wing panel. The playback wing emulates motorized faders.

Set the editor panel to “Always on Top” or to automatically minimized when clicking the display window.

Enable or disable keyboard shortcuts for most programming and playback commands. See “ASCII equivalents for console keys” page 9.

Enable playback control - Show or hide the crossfader and the playback controls.

No. Panel control

1 Master display, crossfader, playback controls. This section of the panel can be hidden. See, “To enable Application menu options” on page 4.

2 Parameter selection and wheel bank keys, wheel displays, parameter wheels.

3 Console panel programming keys and their LEDs.

4 General master and BO (blackout) key.

5 Vertical wheel.

6 Trackball.

1

2

3

4

5

6

Page 7: Vector PC - Compulite

4

CompuliteVector PC software

Figure 4: Vector PC panel with Playback Control disabled

To enable Application menu options

1 Mouse over the area just below the panel’s window title (Vector PC Panel).

A hidden menu bar is displayed.

2 Click Application.

The Application menu options are displayed.

3 Click to enable the option.

Enabled options have a check mark.

4 Clicking again removes the check mark and the option is disabled.

Figure 5: Application menu options

To use wheels and faders

Wheels, trackball, and faders on the Vector PC panel or the Remote Editor are fully functional.

1 Place the mouse pointer on the wheel, trackball or fader.

2 Press and hold down the left mouse button.

When clicking a wheel it gets a little larger, so you can see which wheel is active. The wheel remains active until another wheel, trackball, or fader is selected.

Note: The mouse’s scroll wheel can be used to operate the wheels. Click the wheel first to select it.

3 Move the wheel, trackball or fader in the required direction.

Page 8: Vector PC - Compulite

5

VectorDisplay layouts

Display layoutsVector PC assumes there is one monitor connected, therefore only one window is loaded. If there is more than one monitor connected to your PC, you must open new windows on the additional moni-tors or load your show layout and distribute the show layout screens on your monitors.

When working with one monitor you may find it convenient to set the screen resolution to 1280x1024 and load the system layout file named 1Screen 1280 x 1024 Layout.cfg. This layout allows enough room for the Vector PC Panel and the playback wing to appear side by side under the main window display.

If the Vector PC panel or playback wing displays are not visible, restore it to its last position by opeing the Window menu and choosing Reset Dialog Position.

Remote EditorThe Remote Editor utility is included in the Vector PC installation. The Remote Editor allows you to control a console from a remote location.

ATTENTION! The Remote Editor and Vector PC Panel cannot work simultaneously. Close the Vector PC Panel before opening the Remote Editor.

The Application menu options are:

Connect Remote

Disconnect Remote

Always on Top

Keyboard shortcuts

Playback control

To open and connect the Remote Editor

1 Close the Vector PC Panel.

2 Click your PC’s Start menu Compulite Vector PC Remote Editor.

3 Mouse over the area just below the panel’s window title (Remote Editor).

A hidden menu bar is displayed.

4 Click Application.

The Application menu options are displayed.

5 Click Connect Remote.

The Choose Console ID dialog box opens.

6 Click the arrow to view ID numbers of the consoles in the network.

Page 9: Vector PC - Compulite

6

CompuliteVector PC software

Figure 6: Choose Console ID dialog box

7 Click OK.

The dialog box closes. The selected console can now be controlled through the Remote Editor.

The conosle’s ID number is displayed in the Remote Editor’s title bar.

Figure 7: Console ID number is displayed in the title bar

8 To disconnect the Remote Editor, open the Application menu and click Disconnect Remote.

Device BuilderThe Device Builder utility is included in the Vector PC installation. Device Builder contains factory defined fixture profiles and you can also create custom definitions.

To run Device Builder

Click your PC’s Start menu Compulite Vector PC Device Builder.

Vector PC and outputVector PC can output VC (DMX-over-Ethernet) or ArtNet to run a show.

For Vector PC to output ArtNet or more than one VC universe (512 channels), ePort converters must be connected.

Vector PC outputs only one VC universe (512 channels) if no ePort converters are identified.

ATTENTION! Art-Net and VC’s must be enabled in Tools Settings DMX Protocol.

Vector PC and visualizersVector PC can work with a visualizer installed on the same computer as Vector PC or when the visualizer is installed on another computer on the same network.

When the visualizer is installed on the same computer, there is no output limit.

When the visualizer is installed on a different computer, the output is limited to one VC universe (512 channels).

Page 10: Vector PC - Compulite

7

VectorConnecting

Master/Slave with Vector PCVector PC can be connected to a Vector Red, Blue, Green or Orange console to work in a master/slave configuration.

Requirements:

Crossover Ethernet cable or a standard Ethernet cable with a hub.

The same software version installed on the Vector console and the Vector PC.

Connecting Use a standard Ethernet cable when connecting between the Vector control port and the PC port via a hub.

Use a crossover cable when connecting between the Vector data port and PC port.

When the cabling is complete, run the Vector PC application.

To connect and configure

1 On Vector, check the console’s IP address: Tools Communication.

Make a note of the IP address as you will need it later.

2 On the PC, configure the Local Area Connection:

a. Open Network Connections settings on the PC.b. Right click Local Area Connection.c. Choose Properties and double click Internet Protocol (TCP/IP)

OrClick Properties.Internet Protocol (TCP/IP) Properties dialog opens.

d. Choose Use the following IP address.e. In the IP address field enter the prefix used by the Vector network.

Example: Vector IP is 90.10.31.10, the PC IP should be 90.#.#.#.

IMPORTANT! If the Vector software version is older than 3.15.1, the last byte in the PC IP address must be 10.

f. Navigate to Subnet mask. If the subnet mask is not 255.0.0.0, change it to 255.0.0.0.

g. Click OK to close the dialog box and save the changes.

3 Exit the application via File Exit.

4 Restart the application.

5 On Vector PC go to Tools Settings Multi User Slave.

a. Click SLAVE to configure the Vector PC as the slave.

Page 11: Vector PC - Compulite

8

CompuliteMaster/Slave with Vector PC

b. In the Master Console ID field, enter the Console ID for the Vector console.Example: If the Vector console IP is 90.10.31.10, enter 31 in the Master ID field.

Figure 8: Master console ID fieldc. Click OK to close the dialog box.

Data from the master console is downloaded to the slave console.If the connection is not established, make sure that the Local Area Connection is set as the IP address you entered. If not close the Vector PC, correct the IP and restart the PC. Note: If you Vector software version is older than version 3.15, the last bytes in the IP address must be 10.

ATTENTION! On Vector PC the Network ID and Console ID fields may show 0 if the LAN is not named Vector Network . If the network is named Vector Network, the network and console ID numbers are displayed. As some PCs have 2 Ethernet ports or more and if the LAN name does not parse (if it uses characters in non:Latin alphabets) , the Vector PC IP is not displayed.

Page 12: Vector PC - Compulite

ASCII equiva lents fo r console keys

ASCII equivalents for console keys

t

Console key ASCII

+ + (Plus)

- - (Minus)

(through) * (asterisk)

Ctrl + R

(dot) (dot)

@ @

/ (slash) / (slash)

0 through 9 0 through 9

ACTIVE A

ACTIVE ALL Shift + A

B.O. Alt + B

BEAM B

BLIND B

CE Backspace

CHANNEL C

COLOR Alt + C

COPY Ctrl + C

CUE Q

CUT Ctrl + X

DELETE Del / Delete

DIM (mer) D

Dimmer Wheel Shift + < >

EDITORS Ctrl + E

EFFECT E

ENTER ENTER

EXAM X

FAN Alt + F

FREE F12

FULL F

PB's 1 10 Ctrl + F1 F10

GROUP G

HIGHLIGHT H

HOME Home

IMAGE Ctrl + Alt + F7

INTENSITY I

JOIN J

LIBRARY Alt + L

LOWLIGHT Shift + H

M(acros) 101 106 Shift + F1 F6

MACRO M

NEXT Page up

ON O

ON (parameter value) Shift + Z

PAN

Parameter key 1 F1

Parameter key 1 F1

Parameter key 2 F2

Parameter key 3 F3

Parameter key 4 F4

Parameter key 5 F5

Parameter wheel 1 F1 +

Parameter wheel 1 F1 +

Parameter wheel 2 F2 +

Parameter wheel 3 F3 +

Parameter wheel 4 F4 +

Parameter wheel 5 F5 +

PARK Shift + K

PASTE Ctrl + V

Console key ASCII

Page 13: Vector PC - Compulite

ASCII equiva lents fo r console keys

PB PAGE DOWN Alt + Page Down

PB PAGE UP Alt + Page Up

PB RELEASE Alt + P

SHIFT + PB RELEASE Shift + Alt + P

PB/QK DISPLAY Alt + Scroll Lock

SHIFT + QLIST(playback)

Ctrl + L

POSITION P

PREV(ious) Page down

PRIORITY Insert

QLIST L

RATE %

REDO Ctrl + Y

RELEASE END

RESET ESC

SEQUENCE Ctrl + Q

SHIFT + SET Shift + S

MATRIX (media server) Alt + S

SETUP F6

SHAPE Alt + H

SHIFT SHIFT

SHIFT + SHIFT +

SHIFT + ||/ Shift + Hold/Back

SHIFT + FREE Shift + F12

SHIFT + RESET Shift + ESC

SHIFT + SNAP GO Shift + Ctrl + G

SHIFT + TIME (time line)

Shift + T

SNAP Ctrl + S

SNAP GO Ctrl + G

SNEAK K

SOLO Ctrl + O

SPOT S

Console key ASCII

STAGE Ctrl + T

STEP Ctrl + P

STORE R

STORE+ Alt + R

SUB MASTER Ctrl + B

TEACH MACRO Shift + M

TEXT Alt + T

TILT h i

TIME T

TRIGGER Shift + G

UNDO Control + Z

UPDATE U

WIN/RT MODE Scroll lock

ZERO Z

Playback keys and controls

Console key ASCII

GO (pb controls) Alt + G

Select PB's 1 10 Alt + F1 F10

SHIFT + GO (pb controls) Shift + Alt + G

HOLD/BACK PB 1 10 Ctrl + 1 10

||/ Pause

Flash PB keys 1 10 Alt + 1 10

GOTO F11

GO (master playback) Space

HOLD (master playback) F9

BACK (master pb) F10

Select A/B Alt + F11

GO A/B F7

HOLD/BACK (A/B) F8

Console key ASCII

Page 14: Vector PC - Compulite