VentSure ® InFlow Vent Installation Instructions Eave Application Eave Application Installation Instructions 1. Deck Opening Measure up 6 ½” from the eave edge, along the rake edge towards the ridge and place a mark on the roof deck (reminder that insulation cannot block the vent opening). Move to the other end of the roof and measure 6 ½” from the eave edge towards the ridge and make another mark on the roof deck and snap a chalk line. Now measure up 1” from the chalk line and make a second mark on the roof, which should be 7 ½” from the eave edge. Do the same at the other end of the roof and snap a second chalk line. This will be the location of the opening for the intake. See Figure A. Keep the opening a minimum of 6” away from both rake edges, chimneys, skylights and vertical wall projections such as dormers, and a minimum of 24” away from roof valleys. Using a circular saw with the depth set to the thickness of the wood sheathing, cut and remove the area between the two chalk lines. See Figures B and C. 2. Underlayment Install a minimum 18” piece of WeatherLock ® self-sealing underlayment starting at the eave edge. See Figure D. Once the self-sealing underlayment has been installed use a sharp utility knife to remove the underlayment from the 1-inch slot. See Figure E. 3. Installing the Vent Working left-to- right, install the vent flush with the eave edge using the vent alignment notch and flush with the rake edge. Maintain a full 4’ vent at both ends of the roof and use a utility knife to cut the second to last piece to length and trim the underside of the cut end to maintain the shiplap joint. Fasten the vent with the nails provided using the built-in nail holes on each vent. See Figure F. 4. Finish Underlayment Once the vent is installed across the roof place a 36” wide piece of WeatherLock ® self- sealing underlayment over the vent at the eave and rake edges and up the roof. In cold climates where code requires the use of an ice and water barrier it must be installed and extend a minimum of 24” past the exterior wall at the eave edge. See Figure G. Finish installing an approved underlayment over the entire roof. See Figure H. Once the underlayment is in place, install a drip edge over the entire rake. 5. Shingle Starter Using the nails provided, install starter strip flush with the vent edge, nailing per shingle manufacturer’s recommendations. See Figure I. 6. Shingle application Using the nails provided, install the first course of shingles over the eave vent and continue the remaining shingle courses per the shingle manufacturer’s recommendations. See Figure J. Figure A remove 6 1/2˝ 1˝cutout Figure F Figure D Figure B Figure G Figure E Figure C Figure H Figure I Figure J

Upload: others

Post on 26-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: VentSure InFlow Vent - Owens Corningroofingca.owenscorning.com/docs/InFlowVent-Installation...the roof until the top course of shingles overlaps the 12” mark that was made in Step

VentSure® InFlow™ VentInstallation InstructionsEave Application

Eave Application

Installation Instructions

1. Deck OpeningMeasure up 6 ½ ” from the eave edge, along the rake edge towards the ridge and place a mark on the roof deck (reminder that insulation cannot block the vent opening). Move to the other end of the roof and measure 6 ½ ” from the eave edge towards the ridge and make another mark on the roof deck and snap a chalk line. Now measure up 1” from the chalk line and make a second mark on the roof, which should be 7 ½ ” from the eave edge. Do the same at the other end of the roof and snap a second chalk line. This will be the location of the opening for the intake. See Figure A.

Keep the opening a minimum of 6” away from both rake edges, chimneys, skylights and vertical wall projections such as dormers, and a minimum of 24” away from roof valleys.

Using a circular saw with the depth set to the thickness of the wood sheathing, cut and remove the area between the two chalk lines. See Figures B and C.

2. UnderlaymentInstall a minimum 18” piece of WeatherLock® self-sealing underlayment starting at the eave edge. See Figure D.

Once the self-sealing

underlayment has

been installed use

a sharp utility knife

to remove the

underlayment from

the 1-inch slot. See

Figure E.

3. Installing the VentWorking left-to-right, install the vent fl ush with the eave edge using the vent alignment notch and fl ush with the rake edge. Maintain a full 4’ vent at both ends of the roof and use a utility knife to cut the second to last piece to length and trim the underside of the cut end to maintain the shiplap joint. Fasten the vent with the nails provided using the built-in nail holes on each vent. See Figure F.

4. Finish UnderlaymentOnce the vent is installed across the roof place a 36” wide piece of WeatherLock® self-sealing underlayment over the vent at the eave and rake edges and up the roof. In cold climates where code requires the use of an ice and water barrier it must be installed and extend a minimum of 24” past the exterior wall at the eave edge. See Figure G.

Finish installing an approved underlayment over the entire roof. See Figure H.

Once the underlayment is in place, install a drip edge over the entire rake.

5. Shingle Starter Using the nails provided, install starter strip fl ush with the vent edge, nailing per shingle manufacturer’s recommendations. See Figure I.

6. Shingle applicationUsing the nails provided, install the fi rst course of shingles over the eave vent and continue the remaining shingle courses per the shingle manufacturer’s recommendations. See Figure J.

Figure A

remove

6 1/2˝

1̋ cutout

Figure F

Figure D

Figure B

Figure G

Figure E

Figure C

Figure H

Figure I

Figure J

Page 2: VentSure InFlow Vent - Owens Corningroofingca.owenscorning.com/docs/InFlowVent-Installation...the roof until the top course of shingles overlaps the 12” mark that was made in Step

VentSure® InFlow™ VentInstallation InstructionsLower Roof/Above Eave Application

Lower Roof/Above

Eave Application

Installation Instructions

Step 1: Determine the Vent Slot OpeningMake a mark on the roof at least 12-inches higher than the exterior wall beneath the overhang. This is the lowest recommended starting point for the vent slot/opening. See Figure A.

Step 2: Shingle ApplicationInstall underlayment and shingles from the lower edge of the roof until the top course of shingles overlaps the 12” mark that was made in Step 1 and stop.

Step 3: Cutting the Vent Slot/OpeningMeasure up 6 ½ ” from the bottom of the shingle tab of the top course installed in Step 2. Snap a chalk line at this height across the roof deck from rake edge to rake edge. Measure up 1” from this line and snap a 2nd chalk line across the roof deck from rake edge to rake edge. This will be the slot/opening for the vent intake. See Figure B.

Note: When cutting the vent slot/opening, do not cut any closer than 6-inches from the rake edge.

Step 4: Installing the VentPosition the vent with the alignment notch at the bottom edge of the last shingle course. Hand nail the vent with nails provided. See Figure C.

Step 5: FinishingAfter the vent is installed over the 1” vent slot/opening install WeatherLock® self-sealing underlayment (or a comparable product) and Starter Strip on top of the vent. See Figure D.

Hand nail the Starter Strip and fi rst course of shingles over the vent using the fasteners provided. A nail gun can be used once the shingles are installed past the vent.

Note: The opening in the top of the vent must be left exposed to ensure proper ventilation. Do not shingle over or cover the vent opening.

Figure A

Figure B

Figure C

Figure D

Pub. No. 10018103-A. Printed in U.S.A. January 2013. THE PINK PANTHER™ & © 1964–2013 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. © 2013 Owens Corning Roofing & Asphalt ,LLC. All Rights Reserved.

Page 3: VentSure InFlow Vent - Owens Corningroofingca.owenscorning.com/docs/InFlowVent-Installation...the roof until the top course of shingles overlaps the 12” mark that was made in Step

VentSure® InFlow™ VentInstallation InstructionsLower Roof/Above Eave Application

Lower Roof/Above

Eave ApplicationVentSure® InFlow™ VentInstrucciones de instalaciónAplicación de alero

Aplicación de alero

Instrucciones de instalación

1. Apertura de la plataformaMida hasta 6 ½ pulg. desde el borde del alero, a lo largo de la cornisa del tímpano hacia la cumbrera y coloque una marca en la plataforma del techo (recuerde que la aislación no puede bloquear la apertura de la ventilación). Diríjase al otro extremo del techo y mida 6 ½ pulg. desde el borde del alero hacia la cumbrera. Realice otra marca en la plataforma del techo y trace una línea con tiza. Ahora mida hasta 1 pulg. a partir de la marca de tiza y realice una segunda marca en el techo, la cual debería ubicarse a 7 ½ pulg. del borde del alero. Haga lo mismo en el otro extremo del techo y trace una segunda línea con tiza. Ésta será la ubicación de la apertura para la toma de aire. Vea la Figura A.

Mantenga el orifi cio a un mínimo de 6 pulg. de distancia de ambas cornisas del tímpano, chimeneas, tragaluces y proyecciones de pared vertical como buhardillas y a una distancia mínima de 24 pulg. de los valles del techo.

Utilizando una sierra circular con la profundidad confi gurada de acuerdo al espesor del revestimiento de madera, corte y elimine el área entre las dos marcas de tiza. Vea las Figuras B y C.

2. RevestimientoInstale una pieza de 18 pulg. como mínimo de revestimiento autosellante WeatherLock® en el borde del alero. Vea la Figura D.

Una vez que el revestimiento autosellante ya ha sido instalado, use un cúter afi lado para eliminar el revestimiento de la ranura de 1 pulgada. Vea la Figura E.

3. Instalación de la ventilaciónComenzando de izquierda a derecha, instale la ventilación alineada con el borde del alero utilizando la muesca de alineación de la ventilación y alineada con la cornisa del tímpano. Mantenga una ventilación total de 4 pies en ambos extremos y use un cúter afi lado para cortar la penúltima pieza a medida y corte la parte inferior del extremo cortado para mantener la junta del traslapo. Ajuste la ventilación con los clavos provistos utilizando los orifi cios para clavos que ya están incorporados en cada ventilación. Vea la Figura F.

4. Termine el revestimientoUna vez que la ventilación esté instalada en el techo coloque una pieza de 36 pulg. de ancho de revestimiento autosellante WeatherLock® en la ventilación del alero y en la cornisa del tímpano hacia la parte superior del techo. En climas fríos donde el código requiera el uso de una barrera de hielo y agua, ésta debe ser instalada y debe extenderse por un mínimo de 24 pulg. pasando la pared exterior en el borde del alero. Vea la Figura G.

Termine de instalar el revestimiento aprobado en todo el techo. Vea la Figura H.

Una vez que el revestimiento esté en su lugar, instale el borde de goteo sobre la totalidad del tímpano.

5. Tejas iniciales Utilizando los clavos que se proveen, instale la sección inicial alineada con el borde de la ventilación, clavando las tejas de acuerdo a las recomendaciones del fabricante. Vea la Figura I.

6. Instalación de tejasUse los clavos provistos para instalar la primera hilera de tejas sobre el respiradero del alero y luego continúe con las hileras de tejas restantes según las recomendaciones del fabricante de las tejas. Vea la Figura J.

Figura A

remove

6 1/2˝

1̋ cutout

Figura D

Figura B

Figura C

Figura F

Figura E

Figura G

Figura I

Figura J

Figura H

Page 4: VentSure InFlow Vent - Owens Corningroofingca.owenscorning.com/docs/InFlowVent-Installation...the roof until the top course of shingles overlaps the 12” mark that was made in Step

VentSure® InFlow™ VentInstrucciones de instalaciónAplicación en techos inferiores/sobre un alero

Aplicación en techos

inferiores/sobre un alero

Instrucciones de instalación

Paso 1 : Determine Ia apertura de Ia ranura de ventilaciónHaga una marca sobre el techo ubicada al menos 12 pulg. más elevada que Ia pared exterior debajo de Ia saliente. Éste es el punto inicial más bajo recomendado de Ia ranura/apertura para Ia ventilación. Vea Ia Figura A.

Paso 2: lnstale las tejaslnstale el revestimiento y las tejas desde el borde inferior del techo hasta que Ia hilera superior de tejas se superponga sobre Ia marca de 12 pulg. que se realizó en el Paso 1 y deténgase.

Paso 3: Corte Ia apertura/ranura para Ia ventilaciónMida hasta 6 ½ pulg. desde Ia parte inferior de Ia lengiieta de Ia teja de Ia hilera superior instalada en el Paso 2.Trace una linea de dza a esta altura a través de Ia plataforma del techo desde una comisa del tfmpano hasta Ia otra. Mida 1 pulg. desde esta línea y trace una segunda linea de tiza a través de Ia plataforma del techo desde una cornisa del tímpano hasta Ia otra. Ésta será Ia apertura/ranura para Ia toma de aire de Ia ventilación. Vea Ia Figura B.

Nota: Cuando corte Ia apertura/ranura, no corte más cerca que 6 pulg. desde Ia comisa del tímpano.

Paso 4: lnstale Ia ventilaciónColoque Ia ventilación con Ia muesca de alineación en el borde inferior de Ia ultima hilera de tejas. Asegure, martillando a mano, Ia ventilación con los clavos proporcionados. Vea Ia Figura C.

Paso 5: TerminaciónDespues de que se instale Ia ventilación sobre Ia apertura/ranura de ventilación de 1 pulg., instale el revestimiento autosellante Weatherlock® (o un producto equivalente) y las tejas de Ia hilera inicial sobre Ia ventilación. Vea Ia Figura D.

Asegure, martillando a mano,la hilera inicial y Ia primera hilera de tejas sobre Ia ventilación usando los sujetadores provistos. Puede usar una pistola neumatica cuando las tejas esten instaladas mas alia de Ia ventilación.

Nota: La apertura en Ia parte superior de Ia ventilación debe quedar expuesta para garantizar Ia ventilacion correcta. No coloque tejas sobre Ia apertura de Ia ventilación ni Ia cubra.

Figura A

Figura B

Figura C

Figura D

Pub. N.º 10018103-A. Impreso en EE. UU. Enero 2013. THE PINK PANTHER™ & © 1964–2013 Metro-Goldwyn-Mayer Studios Inc. Todos los derechos reservados. El color PINK es una marca comercial registrada de Owens Corning. © 2013 Owens Corning Roofing & Asphalt ,LLC. Todos los derechos reservados.