version descritpion document - inspect 3d - inca3d ... installation and license key installation...

13
VERSION DESCRIPTION DOCUMENT Last modification: 2017-09-25 Responsible: Stéphane PÉNEAU (Inspect 3D) Software version: V.6.2.0.0 (patch 1..3) Date of print 2017/09/27 13 page(s) VDD_INCA3D_English_2017-09-25_V_6_2_0_3.doc Page 1 of 13 Form I3D-VDD001 Release Date: 2017-05-15 General Advantages: CAD improvement Milling 5 axis Measuring Path Wizard improvement Relative probing with Measured entities Extensions: CAD importation o 3D ACIS CAD file interface o Rhino CAD file interface o Solid Edge CAD file interface Action parameter windows o A small icon in the tabsheet informs user about kind of Nominal and actual o Keyboard / Probed o Constructed / Probed Report Keywords o Ability to filter Keywords displayed in label format editor (also available in xls export) o Use icon to display full list, standard list or short list Global modification o Ability to change tolerance for “Distance simple” and for “Angle” Ability to execute only one action in execution mode o

Upload: hatram

Post on 25-Mar-2018

222 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Version Descritpion Document - Inspect 3D - Inca3D ... installation and License Key Installation must be performed with Windows administrator right. MORA CAA: Inca 3D shared directory

VERSION DESCRIPTION DOCUMENT

Last modification: 2017-09-25

Responsible: Stéphane PÉNEAU (Inspect 3D) Software version: V.6.2.0.0 (patch 1..3)

Date of print 2017/09/27 13 page(s)

VDD_INCA3D_English_2017-09-25_V_6_2_0_3.doc Page 1 of 13 Form I3D-VDD001

Release Date: ▪ 2017-05-15

General Advantages:

▪ CAD improvement ▪ Milling 5 axis ▪ Measuring Path Wizard improvement ▪ Relative probing with Measured entities

Extensions:

• CAD importation o 3D ACIS CAD file interface o Rhino CAD file interface o Solid Edge CAD file interface

• Action parameter windows o A small icon in the tabsheet informs user about kind of Nominal and actual

o Keyboard / Probed

o Constructed / Probed

• Report Keywords o Ability to filter Keywords displayed in label format editor (also available in xls export)

o Use icon to display full list, standard list or short list

• Global modification

o Ability to change tolerance for “Distance simple” and for “Angle”

• Ability to execute only one action in execution mode

o

Page 2: Version Descritpion Document - Inspect 3D - Inca3D ... installation and License Key Installation must be performed with Windows administrator right. MORA CAA: Inca 3D shared directory

VDD_INCA3D_English_2017-09-25_V_6_2_0_3.doc Page 2 of 13 Form I3D-VDD001

• NC file extraction o Ability to extract a part of NC file by selection o User can select a part of displayed mill file and create a new « partial »milling file

allowing to mill again only one area of the file (after refilling gap with clay for example, or unexpected milling result in one area)

o

o A dialog is displayed to adjust gage point before/after and intermediate gage point o Gage point can be generated in Tool direction or in specific direction o Created file in name “OriginalFile_partial.nc”

o

Page 3: Version Descritpion Document - Inspect 3D - Inca3D ... installation and License Key Installation must be performed with Windows administrator right. MORA CAA: Inca 3D shared directory

VDD_INCA3D_English_2017-09-25_V_6_2_0_3.doc Page 3 of 13 Form I3D-VDD001

• Star Probe o Ability to use Star probe with 4 tips (1 vertical and 3 horizontal 120°angle) o Ability to define orientation of the horizontal tips

o • Measured Point measured with Cylinder (or shaft)

o Ability to offset measuring path in the direction of the tool to measure point along a boundary with cylindrical probe or shaft

o

Page 4: Version Descritpion Document - Inspect 3D - Inca3D ... installation and License Key Installation must be performed with Windows administrator right. MORA CAA: Inca 3D shared directory

VDD_INCA3D_English_2017-09-25_V_6_2_0_3.doc Page 4 of 13 Form I3D-VDD001

• Copy/Paste special in measpath editor

o Ability to copy and paste with transformation inside the measuring path editor

o Allowing for example to rotate Gage points, Probed Points and Probe orientation around a circular part

Page 5: Version Descritpion Document - Inspect 3D - Inca3D ... installation and License Key Installation must be performed with Windows administrator right. MORA CAA: Inca 3D shared directory

VDD_INCA3D_English_2017-09-25_V_6_2_0_3.doc Page 5 of 13 Form I3D-VDD001

• Ability to split CAD assembly (CATIA catproduct, SOLIDWORKS sldasm …) in several BGF files

o

• Ability to used point from another entity in action “circle constructed by point” without recalculating probe compensation according to the circle.

o

o This parameter is available for actions « constructed by points » Circle, Plane, Line

• Measurement of Thread hole

o Ability to measure thread hole/shaft with cylinder measuring path wizard

o

Page 6: Version Descritpion Document - Inspect 3D - Inca3D ... installation and License Key Installation must be performed with Windows administrator right. MORA CAA: Inca 3D shared directory

VDD_INCA3D_English_2017-09-25_V_6_2_0_3.doc Page 6 of 13 Form I3D-VDD001

Requirements:

Usable Operating Systems: ▪ Windows™ Ten Pro (64 or 32); Windows™ Eight Pro (64 or 32 bits without aero);

Windows™ Seven Pro (64 or 32 bits without aero); ▪ Compliant but not recommended Windows™ Vista Pro (64 or 32 bits without aero),

Windows™ XP Pro (32 bits), ▪ Compatibility of the hardware device, Counter Card, Link to DCC must be checked

separately with the hardware provider ▪ INCA3D installation and License Key Installation must be performed with Windows™

administrator right. MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini

o To avoid trouble with windows virtual store directory both softkomp.ini and vm.ini files are now located in “Inca3d\machine”

o This new location also allows using 2 different CAA files when working in multi machine mode

Multiplex Configuration: ▪ Working directories /CAD and /OperationSequence should be same shared directories on all

PC’s.

Dongle driver:

• Download at http://www.inspect-3d.com/english/software/download.htm - For Windows Vista, Seven, XP 1- Install first HASP HL Driver V5.22: haspusersetup.exe (V5.22) 2- Then install HASP4 Device Drivers V 5.22: hdd32.exe (HASP4 V 5.22)

Remarks

• Some of the functions and improvements described in this document may not be available for your INCA3D license depending on Package and options. Contact us for further details

Documentation updates: ▪ 2013-07-15 English Help Version E.1.21 ▪ 2013-07-15 German Help Version G.1.9 ▪ 2013-07-15 French Help Version F.1.12 ▪ 2013-07-15 Chinese Help Version C1.0

Valid Maintenance Date needed: ▪ 2017-06-15

Modifications & Bug fixes (V6200 – 2017-05-30):

Wishes Done: R6558:” QDAS: K0XXX/0 at the end of the file” Need to add %END% before Keyword KXXX in

QsStat.ini file DONE R6567:” In measpath editor do not display probed point from scanning when count is upper than

500” DONE R6572:” Star probe 4 way” DONE R6573:” Star probe: be able to use tips #2 not align with machine axis” DONE R6592:” When receiving 2 different errors from the machine driver, display the 2 errors not only

the last one” DONE R6594:” Add the possibility to select "None" in the secondary direction of the geometrical

alignment” DONE R6598:” In NC file creation window, possibility to show/hide the original milling file” DONE R6604:” Improvement in display of Pt Vector, Edge pt. Surf normal is always displayed in

standard mode, edge vector always in dash mode,” DONE R6605:” In NC file creation window: If the distance between two non-consecutive points is greater

to a value, add intermediate gage points. If some points are isolated, be able to eliminate them” DONE

R6557:” ZAK: Ability to Change milling tool by vector” DONE R6606:” When switch between PH9 to PH10, allow user to keep all tools definition instead of

remove everything and create new tool files” All tools are uncalibrated to force the user to recalibrate all DONE

Page 7: Version Descritpion Document - Inspect 3D - Inca3D ... installation and License Key Installation must be performed with Windows administrator right. MORA CAA: Inca 3D shared directory

VDD_INCA3D_English_2017-09-25_V_6_2_0_3.doc Page 7 of 13 Form I3D-VDD001

R6609:” From milling action be able to open containing folder of the NC file, edit the NC file or force display update of the NC file” DONE

R6621:” Result window. Tolerances, decimal values 0 removed. 1.500 -> 1,5” DONE R6615:” Change date of the calibration when make optimization of probe in the ops” DONE R6504:” Measured Distance nom & actual. Nominal construct by point - point: there is no red

target to select the points in the graphic.” DONE R6636:” In measpath editor, be able to import points from a NC file as gage point or probed point

measuring path elements” DONE

Fixed Bugs: R6575:” Straightness may give wrong results with small amount of points and no projection

plane” FIXED R6565:” In the out of tolerance window, the deviations values are not fully visible in German

language because text is longer than English” FIXED R6564:” If I drag n drop from the editor a measured circle in a combo box that is in the "Real"

tabsheet then by default "Circle.Actual" is selected. If I do the same using the red target and double clicking on the graphic circle label I have instead "Circle.Nominal” FIXED

R6566:” ZAK Standard: D2 in the Inca3D configuration is normed. Length of the D2 is lost” FIXED R6571:” Laser scanner: When activate Save laser point in separate files, recalculate the sampling

line for display according to sampling line set in machine parameters to get always same display.” FIXED

R6574:” Alphabetical order in the Label page editor is not correct.” FIXED R6576:” Statistic values are not exported to Excel” FIXED R6577:” Missing text and/or results in GD&T generic labels since introduction of new 'generic'

keywords” FIXED R6578:” Sometimes when click on shortcut to make direct report preview and in this preview

window, click to open the standard parameters window, generate a report, it can happen an empty preview window is opened and difficult to close it.” FIXED

R6581:” Measured Circle/Cylinder. If the nominal is 'by points' then the checkbox "Center locked on nominal" is displayed in the '+' of the nominal. Should only be displayed in the real when real is 'By points' or 'Probed'.” FIXED

R6588:” Cylinder scanning in spiral does not work in Pantec and virtual machine” FIXED R6593:” Nominal referenced action in geometrical alignment are not displayed at the right position

in the graphical view” FIXED R6595:” Cannot calculate Y coordinate of Y2 after a global execution of the ops by intersection

Line/Surface in one direction.” FIXED R6597:” With new version 6.0.0.15, the report manages a number of decimal for points… These

values are initialized with 3 but if in configuration we defined 2, it is not take into account” FIXED

R6602:” In a very large OPS when I delete the main alignment, it takes more than 1 minute to display anew the operation sequence and there is flickering in the editor during the display.” FIXED

R6596:” In the ops, in execution, when try to execute entities without Measpath, Inca should allow to teach the point and in fact it makes guidance on the first point with a measpath. It cannot not possible with simulator to take point and continue execution” FIXED

R6600:” Event action. If we display an image larger than screen the image is truncated but should be proportionately resized. Add also a preview button to see in teach and learn mode how will be the event window.” FIXED

R6300:” Star probe view: when clicking on the list view, form deviation disappears. Orientation PH1 to be verified” FIXED

R6610:” Measured Circle. "Center locked on nominal" check box is over "Acceptable distance" field.” FIXED

R6619:” Switch from Star Probe 1.3 T2 to NOT Star probe 1.2 in the counter still written T2 and in measuring the ball diameter is the wrong one” FIXED

R6620:” With SCR200 when go to "Tool manger" and say that pocket 2 is loaded instead of Pocket 1 and execute a gage point then no message saying that wrong probe is loaded” FIXED

R6622:” Improvements and bugs fixes in the display of section views” FIXED R6623:” Scan with I++ driver: Scanning distance is not applied. Scan are always performed with

default scanning distance” FIXED R6624:” ZAK: If a tool is active in the operation sequence and the user start the ZAK calibration,

during the calibration tool vector for CAA is updated due to A&B update.” FIXED

Page 8: Version Descritpion Document - Inspect 3D - Inca3D ... installation and License Key Installation must be performed with Windows administrator right. MORA CAA: Inca 3D shared directory

VDD_INCA3D_English_2017-09-25_V_6_2_0_3.doc Page 8 of 13 Form I3D-VDD001

R6625:” When make a preview with graphic shortcut, the preview is always in draft mode even if switch back to report parameter window.” FIXED

R6626:” Calculation of cylinders’ axis with center position locked on the nominal position is not performed properly” FIXED

R6627:” Wrong Display with generic stylus length = 3mm diameter 1mm” FIXED R6628:” Keyboard distances and angles XYZ cannot be filled during execution ("exec" flag

checked)” FIXED R6629:” Create a probed line with XY+ projection plane with Measpath wizard, so "at probing

depth", probe it, reopen the action and switch to "As taught" --> all the probed Z value are set to 0.00” DONE

Modifications & Bug fixes (V6201 – 2017-05-30):

• GDT: Unequally disposed tolerance zone management and

Wishes Done: R6631:” Possibility to have in Report for GD&T entities the length Type KW.” DONE R6637:” Excel customizable: Remove unnecessary save message” DONE R6459:” GDT Profile: manage asymmetrical tolerance = 0.3 u 0.1 (U in a circle)” DONE R6540:” Laser scanner: When do save as of an operation sequence, laser scanner folder and

files are not renamed according to new operation sequence name” DONE R6638:” Report parameters: Add a new choice in the list of printers to use the default printer”

DONE R6570:” Be able to change milling acceleration inside the operation sequence” Move acceleration

is used also for milling DONE R6372:” Action tool calibration with I++: UCCServer is calculating properly the way to go from the

rotation position to the sphere but from the end position of the calibration to the rotation position we get some collisions.” If there is a star we move first along the tip direction then along Tip 1 before moving back to the rotation point. Move distance are available in Inca.ini. By default, distances are set to 0.0 DONE

R6644:” Accelerate the display of the Deviation Vector (Line/Disk/Vector)” DONE R6645:” Display of lot of Spheres, Cylinders, Disks, Cones, Global Measuring Path. Improve the display and possibility to have more in the view” DONE R6644:” Use the execution option for recalculation of alignment (move points or keep points)

during the global validation of measure” DONE

Fixed Bugs: R6632:” Operation sequence with loop and script. Ask each time to save the ops.” FIXED R6640:” Kreon Arm: If no scanner selected, machine parameter display sampling line” FIXED R6641:” Kreon Arm: When change probe, Inca3D do not display any change tool confirmation”

FIXED R6642:” Kreon Arm: In Inca3D configuration propose C:\ProgramData\Kreon

Technology\Calibration as default folder for the arm calibration file” FIXED R6643:” Kreon scanner: In Inca3D configuration propose C:\ProgramData\Kreon

Technology\Calibration as default folder for the scanner calibration file” FIXED R6644:” Arm: When scan with arm in teach mode, intermediate points are not displayed in

graphic view” FIXED R6645:” Arm: When scan with arm in teach mode 20 points (for example) at end of the scan there

is 40 points saved in Inca3D” FIXED R6644:” Arm: Count of points displayed during scan in teach mode is not correct” FIXED R6591:” Excel report: With Windows10 OS, the excel 2016 program overlap a little bit Inca3D

windows. Furthermore, in multiscreen, Excel is displayed on the second screen with a very small width.” FIXED

R6644:” Sometime when I switch between nominal kinds in a measured action there is an error (catch 2.481.1 / 2.513.1).” FIXED

Page 9: Version Descritpion Document - Inspect 3D - Inca3D ... installation and License Key Installation must be performed with Windows administrator right. MORA CAA: Inca 3D shared directory

VDD_INCA3D_English_2017-09-25_V_6_2_0_3.doc Page 9 of 13 Form I3D-VDD001

Modifications & Bug fixes (V6202 – 2017-08-29):

• SP80 management with Pantec Eagle Pro

• Pantec Eagle Driver –

o With TP200 or SP25, ability reset the probe after collision or any event that "lock" the probe ability to reset Function available from pop menu of the counter

o

• PMI management

o Ability to import hidden PMI information (checkbox in importation window)

o Ability to import Datum target and Note –

• PH10 management

o Abiltty to deactivate probe buffer during head rotation

o Changing Rack: ability to set MCR20 or SCR200 in vertical position

• Load OPS action

o Abilty to load an OPS according to a string variable

• Input variable from file

o Abilty to pause the execution when input file does not exist, waiting for user or external process to create the input file

Page 10: Version Descritpion Document - Inspect 3D - Inca3D ... installation and License Key Installation must be performed with Windows administrator right. MORA CAA: Inca 3D shared directory

VDD_INCA3D_English_2017-09-25_V_6_2_0_3.doc Page 10 of 13 Form I3D-VDD001

Wishes Done: R6644:” Use the execution option for recalculation of alignment (move points or keep points)

during the global validation of measure” DONE R6645:” In Load Ops, have the possibility, in the list to Open folder containing the selected ops

(like in load Cad, with a popup menu).Add also the possibility to copy all the files name+path in the clipboard.” DONE

R6645:” SP25 with Standard tool (PH6M, …)” DONE R6645:” SP25 with Star + Standard tool” DONE R6645:”I++ DME driver: Do not allow tool selection while Inca3D import tools from I++ Server”

DONE R5515:” Display full ops measuring path,improvement allowing to display large OPS” DONE R6306:” Shape deviation view : add ability to display 3 entities (sphere,cylinder, cone …) in

transparent mode” DONE R6645:” SP80 with Pantec Eagle” DONE R6644:” SP80 change tool holder SCP80” DONE R6645:” Add a option to have possibility to import hidden FD&T element from Cad file.” DONE R6644:” Improvement in import of FD&T entities from Cad file.” DONE R6645:” During head PH10 rotation, receive error unexpected probe contact even dip switch on

the PHC10 are correctly set” DONE R6644:” "Plane by points and offset": abilty to manage list of point” DONE

Fixed Bugs: R6490:” Measured Line. When I click an Edge point on the CAD file, the second vector (edge

vector) is not used to define the probing vector in wizard. So sometime Inca3D calculates a measuring path inside the material and we need to reverse manually the probing v” FIXED

R6644:” Create a probed point, click apply and probe, click gage point in entity toolbar, click cancel, click yes, click gage point --> temporary gage point stays visible and is undeletable” FIXED

R6645:” Do not manage ligthing when display entity vector in graphical view.” FIXED R6644:” Add new format graphical label for section (and edge section) with tol strip” FIXED R6645:” Pantec Eagle driver: With TP200 or SP25, be able to reset the probe after collision or

any event that "lock" the probe” FIXED R6645:” Pantec Eagle driver TP200 with WPC2030: When get error "unexpected probe contact",

error is not cleared when click ON on error message” FIXED R6645:” ZAK: When used a sphere as center of machine alignment, there is always a deviation

when probe a sphere in the operation sequence with A0B0” FIXED R6645:” The CAD conversion file window sometimes goes below Inca3D and the software is

locked.” FIXED R6644:” Action Alignment by file: Ability to select an action string or a formula for the name of the

file to load” FIXED R6645:” "Plane by points and offset": to be improved for scanned plane containing many point too

much refresh” FIXED R6645:”scanned entitiy SP25 with many points: in GUI tabsheet shape deviation if you try to

delete One point INTERNAL ERROR” FIXED R6617:” Ability to run several programm started by external file created by another computer”

FIXED R6649:” Qstat export, date/time are not exported correctly, the format is not correct.” FIXED R6651:” Probe driver for PH10: checkbox Optimize communication is not anymore visible” FIXED

Page 11: Version Descritpion Document - Inspect 3D - Inca3D ... installation and License Key Installation must be performed with Windows administrator right. MORA CAA: Inca 3D shared directory

VDD_INCA3D_English_2017-09-25_V_6_2_0_3.doc Page 11 of 13 Form I3D-VDD001

Modifications & Bug fixes (V6203 – 2017-09-25):

• Shape Deviation view

o Abilty display calculated and nominal entities with transparency

o Ability move with left and righ arrow in the tabsheet form deviation

o

• MR12 Driver

o Ability to set “minumim trigger time” in configuration to avoid get air trigerring when machine has vibration (Set by default to 50ms)

o

Page 12: Version Descritpion Document - Inspect 3D - Inca3D ... installation and License Key Installation must be performed with Windows administrator right. MORA CAA: Inca 3D shared directory

VDD_INCA3D_English_2017-09-25_V_6_2_0_3.doc Page 12 of 13 Form I3D-VDD001

• Coordinate systeme – Mutli-Alignment

o This function allows to load different alignment for the same coordinate system in alignment by file allowing to measure part in 2 steps with ability to move the part on the machine between those 2 steps

Page 13: Version Descritpion Document - Inspect 3D - Inca3D ... installation and License Key Installation must be performed with Windows administrator right. MORA CAA: Inca 3D shared directory

VDD_INCA3D_English_2017-09-25_V_6_2_0_3.doc Page 13 of 13 Form I3D-VDD001

Wishes Done: R6655:” Form deviation window : Display the form deviation value even if the mouse is above or

below the deviation rectangle. If many points, be able to move the mouse pixel by pixel using the right and left keyboard key.” DONE

R6662:” Change default value for measpath wizard circle (offset equator =0.00, 4 pts by circle without top)” DONE

R6663:” MR12/MR11 driver: Use driver directly from Inca3D instead of using GNC.DLL / VM32.DLL” DONE

R6664:” Driver MR11/MR12: Be able to define a minimum trigger time to avoid probe contact due to vibration of the probe during move of the CMM” DONE

R6665:” Driver MR12: Be able to do Home sequence without unplug USB cable from the computer” DONE

R6667:” Pantec driver: Management of motor engage state regarding last user state and Pantec Eagle state” DONE

Fixed Bugs: R6652:” When open an exiting operation sequence and insert a change probe action. The

management of probe change in the following action is not properly done (only for the first action created).” FIXED

R6653:” When click a plane and create the measuring path some points are always removed when using the functionnality "remove points acc. to Cad projection"” FIXED

R6654:” In Form deviation view, FormDeviation value in graphic label is not displayed correctly, text instead the value only in V6202” FIXED

R6656:” In form deviation view parameters, the label format name can be empty and not initialized. Sould be initialized with default graphic label format name only in V6202.” FIXED

R6659:” When display the list of Cad entities with Cad file containing FDT, sometimes Inca3D freezes.” FIXED

R6661:” Global modification window : Adapt the display acc. to probe driver (SP25,Revo,…) for kind of probing modification.” FIXED

R6645:” "Rectitude 4" Straightness gives an error message in Chebychev calculation” FIXED R6670:” With SP80, after removing an optimization in a operation sequence, the orientation of the

SP80 star probe is not the right one.” FIXED R6671:” Action Scan 2D is not working properly since V6.2.0.2” FIXED R6674:” Error message "The procedure entry point SHGetKnownFolderPath could not be located

in the dynamic link library SHELL32.dll" under Windows XP in V6202” FIXED