Vertrel ® vs. Other Systems Aqueous systems Aqueous systems Potential corrosion of metal parts Low rinsing quality Separate drying step needed, lower drying quality Longer cycle time Energy intense High capital investment for the equipment Disposal & recycling possibilities of contaminated water Water availability & price in some Service Chimie : 5 place de l’église, 77400 Saint Thibault des vignes : (33) 01 64 30 89 22 : (33) 01 64 30 87 49 : [email protected]

Upload: natalie-dawson

Post on 28-Mar-2015

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Vertrel ® vs. Other Systems Aqueous systems l l Potential corrosion of metal parts l l Low rinsing quality l l Separate drying step needed, lower drying

Vertrel® vs. Other SystemsVertrel® vs. Other Systems

Aqueous systemsAqueous systems

Potential corrosion of metal parts Low rinsing quality Separate drying step needed, lower drying quality Longer cycle time Energy intense High capital investment for the equipment Disposal & recycling possibilities of contaminated water Water availability & price in some regions

H-1

Service Chimie : 5 place de l’église, 77400 Saint Thibault des vignes

: (33) 01 64 30 89 22 : (33) 01 64 30 87 49

: [email protected]

Page 2: Vertrel ® vs. Other Systems Aqueous systems l l Potential corrosion of metal parts l l Low rinsing quality l l Separate drying step needed, lower drying

Vertrel® vs. Other SystemsVertrel® vs. Other Systems

Chlorinated & bromine-containing solventsChlorinated & bromine-containing solvents

Toxicity Material compatibility Ozone depletion Flashpoint controversy Odor Presence of stabilizers (Need of periodical monitoring to avoid

hydrolysis (acidification) of the solvent)

Difficult process monitoring Need to use expensive equipment

H-2

Service Chimie : 5 place de l’église, 77400 Saint Thibault des vignes

: (33) 01 64 30 89 22 : (33) 01 64 30 87 49

: [email protected]

Page 3: Vertrel ® vs. Other Systems Aqueous systems l l Potential corrosion of metal parts l l Low rinsing quality l l Separate drying step needed, lower drying

Vertrel® vs. Other SystemsVertrel® vs. Other Systems

Alcohols and hydrocarbonsAlcohols and hydrocarbons

Flammability of alcohols Poor rinsing quality with hydrocarbons (no vapor zone) Difficult drying with hydrocarbons

(higher BP, thus higher drying temperature needed)

H-3

Service Chimie : 5 place de l’église, 77400 Saint Thibault des vignes

: (33) 01 64 30 89 22 : (33) 01 64 30 87 49

: [email protected]

Page 4: Vertrel ® vs. Other Systems Aqueous systems l l Potential corrosion of metal parts l l Low rinsing quality l l Separate drying step needed, lower drying

Vertrel® vs. Other SystemsVertrel® vs. Other Systems

Hydrofluoroethers (HFE)Hydrofluoroethers (HFE)

More selective miscibility (less azeotropes available) Co-solvent systems are rarely justified Slightly lower acute toxicity effects Indication for potential of chronic toxicity Auto-ignition temperature (405ºC) Decomposition into PFIB when overheated (> 300°C) Concern of degradation to Trifluoroacetic Acid (TFA) in

the atmosphere, that may attack micro-organisms

H-4

Service Chimie : 5 place de l’église, 77400 Saint Thibault des vignes

: (33) 01 64 30 89 22 : (33) 01 64 30 87 49

: [email protected]