vexl instruments 25.10.18 · for dielectric material in large storage tank but small diameter...
TRANSCRIPT
&
We have a team of experienced engineers who are committed to provide you the right solution at
economical price. Our motto is “CORRECT INSTRUMENT FOR SPECIFIC APPLICATION”.
Level Measurement (Ultrasonic/Radar)
Flow Measurement (EMF/Ultrasonic)
Water Quality Monitoring
VEXL INSTRUMENTS
WATER QUALITY
ANALYSER
LEVEL
Ultrasonic Level
Transmitters
Radar Level
Transmitters
FLOW
Ultrasonic Flow
Meters
Electro-Magnetic
Flow Meters PRESSURE GAUGE
& PRESSURE
TRANSMITTERS
MULTI LAYERED LIQUID
LEVEL ANALYSER
Pressure Gauge & Pressure Transmitters Piezometer
RADAR TRANSMITTER
MODEL NO.
VI-RTL-RA-C 51
Application
Maximum Range
Accuracy +/-10 mm
Process
Connection 1 ½” BSP
Antenna
MaterialPP / PTFE
Process Temp. -40 to 120°C
Process
Pressure
2< 3Kg/cm
Operating
Frequency6 GHz
Output
Corrosive media liquids
with moderate fuming
and foaming conditions
30m
4-20mA,2Wire
(HART-Optional)
DisplayNumeric &
Graphical
ULTRASONIC TRANSMITTER
MODEL NO. VI-ULT 10/15 Application Process Temp.
Maximum Range Process Pr.
Type Operating Freq.Four wire 33 KHz
Power supply Output110/230 V AC 4-20mA, 2 wire
Mounting Accuracy
Process
ConnectionDisplay
Sensor Material Dead Band
Housing Material
Top 0.25% of FS
FlangedNumeric &
Graphical
Nylon 6 600mm
Cast Al. PU painted
Level measurement
of clear liquids in
large storage tank
-10 to 60 °C
10mtr. / 15mtr. Atmospheric
ULTRASONIC TRANSMITTER
MODEL NO. VI-ULT 4/8
Application
Maximum Range
Type Two wire
MountingTop
Process
Connection
Sensor Material
1 ½”BSP / 2”BSP
PP / PVDF
Housing MaterialCast Aluminum
PU painted
Process Temp. -10 to 60 °C
Process Pressure Atmospheric
Operating
Frequency
Output 4-20mA, 2 wire
Level measurement
of clear liquids
in storage tank
4mtr. / 8mtr.
60KHz / 45KHz
COMPANY NAME
Accuracy
Display
Dead Band
0.2% of FS
Numeric &
Graphical
250mm/350mm
Dead Band 400 mm
SPECIFICATION
SPECIFICATION
SPECIFICATION
RADAR TRANSMITTER
MODEL NO. VI-RTL HA-K 56 Application
Maximum Range 30 Meters
Accuracy +/-3 mm
Process
Connection 1 ½” BSP
Antenna
MaterialSS 316 / PTFE
Process Temp. -40 to 120 C
Process
Pressure < 40Kg/cm2
Operating
Frequency26 GHz
Output 4-20mA, 2 wire
DisplayNumeric &
Graphical
Dead Band 400 mm
Liquids like Oil, fatty acids, mild corrosive
liquids under high temperature /pressure
RADAR TRANSMITTER
MODEL NO. VI-RTS HA-K 57
Application
Maximum Range
Accuracy +/- 3 mm
Process
Connection Flanged SS 316
Antenna
MaterialPTFE
Process Temp. -40 to 150 C
Process
Pressure < 16 Kg/cm2
Operating
Frequency26 GHz
Output
DisplayNumeric &
Graphical
Storage tanks / Process
vessels under high
temperature / pressure
20 Meters
4-20mA, 2 wireCOMPANY NAME
Dead Band Nil
RADAR TRANSMITTER
MODEL NO. VI-RTS HA-K 58Application
Maximum Range 70 Meters
Accuracy +/- 15 mm
Process
Connection
Flanged SS 316 /
PTFE
Antenna
MaterialSS 316 / PTFE
Process Temp. -40 to 200 C
Process
Pressure < 16Kg/cm2
Operating
Frequency26 GHz
Output 4-20mA, 2 wire
DisplayNumeric &
Graphical
Dead Band 400 mm
SPECIFICATION
SPECIFICATION
SPECIFICATION
RADAR TRANSMITTER MODEL NO. VI-RTS-PA-K 59
Application
Maximum Range 70 Meters
Accuracy +/-15 mm
Process
Connection
Flanged SS 316/
PTFE
Antenna
MaterialSS 316 / PTFE
Process Temp. -40 to 200 C
Process
Pressure < 16Kg/cm2
Operating
Frequency26 GHz
Output 4-20mA, 2 wire
DisplayNumeric &
Graphical
Dead Band 400 mm
Solid level measurement for dielectric material inlarge storage tank but
small diameter
Principle
Range
Resolution
Accuracy
Beam Angle
Antenna
Communication
Signal Output
Process Temperature
Power Supply
Frequency Modulated
Continuous Wave
0.1~50/100/150M
0.008mm
<±0.7mm
0.7° (with Antenna Radome)
Lens, PTFE/PEEK/PE,
HART/MODBUS/ PROFIBUS
4-20 mA or RS485
-60~200°C
-60~1000°C (high temperature)
4 wire, DC 9~42V DC
AC 110~250V
RADAR LEVEL TRANSMITTER
120GHz-130GHz FMCWMODEL NO. VI-RLG-HA 9127
Additional Features:Aiming Device Air purging Dual Chamber IP 67
FEATURES
SPECIFICATION
· Meter size: 25 -600mm
Flanged
· Empty pipe detection
· Two line LCD display, 16 characters
per line or graphical display
· Various lining material
· Various sensor material
BATTERY OPERATED ELECTRO-
MAGNETIC FLOWMETER
MODEL NO. VI-EMF-BO 1000
ELECTRO-MAGNETIC
FLOWMETERMODEL NO. VI-EMF-FE 1001
· Meter size: 25 -2000mm
· Flanged or Wafer type
· Empty pipe detection
· Two line LCD display, 16 characters per line or graphical display
· Various lining material
· Various sensor material
· GSM/GPRS connectivity
· In-built data logger
· Bore size: 100 -2200mm
· Integral or Remote Convertor
· Empty pipe detection
· LCD display
· Integral grounding electrode
· Sensing electrode material: ABS / Polypropylene
· Connection type: Flanged or Threaded
INSERTION TYPE ELECTROMAGNETIC
FLOWMETER
MODEL NO. VI-EMF-IT 1003
· Earthing ring in SS 304 / SS 316
· Earthing ring in SS 304 / SS 316
FEATURES
FEATURES
SPECIFICATION
Clamp-on Model Accuracy
Standard
-2 ±1% IP-68
Dn25-100mm
Dn50-700mm
Dn300-6000mm
Dn25-100mm
Dn50-700mm
Dn300-6000mm
-30 to 90°C
TM-1 ±1% IP-68
-30 to 90°C
TL-1
±1%
IP-68
-30 to 90°C
-2-HT
±1%
IP-68
-30 to 160°C
TM-1-HT
±1%
IP-68 -30 to 160°C
TL-1-HT ±1% IP-68 -30 to 160°C
Clamp-on Sensor
High Temperature Clamp-on
ULTRASONIC PORTABLE
CLAMP-ON FLOWMETER
MODEL NO.
VI-UFM-HH-CO 2000H
Principle
Accuracy
Display
Interface
Data Storage
Pipe material
Measuring Range
Liquid
Flow velocity
Power Supply
Transit-time
±1%
4 x 16 characters back - lit
RS 232C
Built-in 32MB logger
CS/SS/CI/GI/ MS
DN 50 – 6000mm
Water, Sewage etc.
0 - ±7m/s
Built-in rechargeable
Ni-MH batteries
Principle
Accuracy
Display
Interface
Data Storage
Pipe material
Measuring Range
Liquid
Flow velocity
Power Supply
Transit-time
±1%
4 x 16 characters back - lit
RS 232C
SD Card (Optional)
CS/SS/CI/GI/ MS
DN 50 – 6000mm
Single liquid like Water, Sewage etc.
0 - ±7m/s
DC 8~36V AC 85~265V
ULTRASONIC WALL
MOUNTED FLOWMETER
CLAMP ON TYPE SENSORS
MODEL NO.
VI-UFM-WM-CO 2000B
FEATURES
FEATURES
Principle
Accuracy
Display
Interface
Data Storage
Pipe material
Measuring Range
Liquid
Flow velocity
Power Supply
Transit-time
±1%
4 x 16 characters back - lit
RS 232C
SD Card (Optional)
CS/SS/CI/GI/ MS
DN 50 – 6000mm
Single liquid like Water, Sewage etc.
0 - ±7m/s
DC 8~36V AC 85~265V
ULTRASONIC WALL
MOUNTED FLOWMETER
INSERTION TYPE SENSORS
MODEL NO.
VI-UFM-WM-IT 2000B
InsertionSensors
High accuracy ±1%
For pipes over
300mm, cost effective
Characteristics
Model TC – 1 Suitable for pipes with welding facilityRange: 50 ~6000mm Pipe thickness: = 20mm Temperature: -30 ~160°C
Model TC – 2
Suitable for non-metallic pipes
Range: 50 ~ 6000mm
Pipe thickness: = 70mm
Temperature: -30 ~ 160°C
Intrusive measurement,
more reliable and stable
pH/ORP CONTROLLER
MODEL NO. VI-POC-7500
Application
Analogue output
Resolution
Control Output
Accuracy
Power supply
0.1 / ±5mV / ±0.5°C Controller – IP65
Sensor – IP 68
Buffer Solution Display
Protection Class
10.00; 7.00;
4.00/9.18; 6.86; 4.01
Single channel
isolated 4-20mA
Back – lit LCD
pH – 0.00 -14.00
ORP – (-1999? +1999) mV
Temp. – 0.00? 99.9°C
Double channel
relay output
0.01 / 1mV /0.1°CpH/ORP 7500-24V DC
pH/ORP 7510 – 110VAC
pH/ORP 7520 -230VAC
COMPANY NAME
Range pH – 0.00 -14.00
ORP – (-1999? +1999) mV
Protection class IP 68
(Optional)
Protection class IP 67
FEATURES
SPECIFICATION
Widely used for monitoring in chemical,
pharmaceutical, food, municipal water for
online Conductivity controller as high
cost effective solution.
CONDUCTIVITY ONLINE
CONTROLLER
MODEL NO. VI-CC-3300· Integrated Conductivity / Resistivity parameter measurement
· Automatic conversion in full range
· Arbitrary selection of Conductivity /Resistivity/TDS
· Check conductivity, temperature, 4-20mA at any time
· 24V DC; 110V AC; 220V AC power supply models available
COMPANY NAME
CHARACTERISTICS
ONLINE TURBIDITY METER
MODEL NO. VI-TM-99
Cable length
Repeatability
Protection class
AccuracyWater Pipe
Response Time
Drainage Pipe
Velocity of Flow
Measurement
Range
0-20NTU
0-200NTU
0-2000NTU
0-100mg/L
0-1000mg/L
10 mtr.(std.) 100 mtr.(max.)
Better than ±1%
IP - 68
±2% of FS
1 second
½”NPT internal
thread, ½”
Hose provided
100-700ml/min
DO ANALYZER
MODEL NO. VI-DA-99
Measurement
RangeTemperature
sensor
ResolutionPressure
Grade
AccuracySalinity
Range
Response
TimeCalibration
Analogue output
Anti-interference
Control Output
0-20mg/L or
0-20ppm
Detection range 0-50°C
Resolution ±0.1°C
Accuracy ±0.5°C
±0.01mg/L0.5MPa
±0.2mg/L or
±1% of FS40ppt
< 60 secondsSingle or two
point. Factory
calibrated
Single channel
isolated 4-20mANot interfered with
H2S, CO2, NH3,
SO4,CL, CLO2,
MeOH, EtOH, etc.Double channel
relay output
Measuring communication, control is completely isolated
SENSORSPECIFICATION
SPECIFICATION
Integrated Parameter
Analyzer (Ph, TSS, BOD, COD)
Ph
Potentiometric
0-14
±0.1%
< 5 Sec
(0-60ºC)
0-850 mm200-400 mm
S.No COD BOD TSS
1Measurement
Principle
Spectral
Measurement
Spectral
Measurement
Spectral
Measurement
2 Wave Band
3
4
5
6
7
8
9
10
200-400 mm
Measurement
Range
< 5 Sec
RS 485/MODBUSRTU
RS 485/MODBUSRTU
RS 485/MODBUSRTU
RS 485/MODBUSRTU
(0-60ºC) (0-60ºC) (0-60ºC)
(0-6) Bar (0-6) Bar (0-6) Bar
12 V/ 24 V
DC
12 V/ 24 V
DC
12 V/ 24 V
DC
(0-500) mg/l (0-100) mg/l (0-50) g/l
Resolution 1 mg/l 1 mg/l 1 g/l
Accuracy ±2%
Response Time
Communication
(0-6) Bar
Voltage12 V/ 24 V
DC
MODEL NO. VI-IP-PTBC-1400
Measurement
Range
Repeatability
Accuracy
Shortest Measurement
period
Calibration period
Measurement
Range
<10% of FS
15 minutes
10-5000mg/L
<5% of FS Output
Digital
Communication
Display
Power Supply
RS 232C / RS 485
Back-lit Graphical
220V AC
Reagent replacement
once every month
Two way
4-20mA Isolated
COD ONLINE ANALYZER
MODEL NO. VI-CA-2001
NOTE - We also provide BOD / Ammonia /
Total Phosphorus Online Analyzer
COD / BOD / TSS / pH
MULTI PARAMETER QUALITY
ANALYZER
MODEL NO. VI-MPA-5000
SPECIFICATION
· Temperature
· ORP/pH
· Dissolved Oxygen
· Conductivity
· Turbidity
· Chlorine
· Chlorophyll
· Can measure 7 parameter
· Power Supply
12V DC
· Also works on Solar Power
· 7.0” LCD Display
· Power-off protection to retain last
measured values
Power: 220V AC , 20W
4-20mA analog and Rs485 digital output, MODBUS protocol
SPECIFICATION
SPECIFICATION
FEATURES
Easy installation & operation.
High accuracy & resolution.
Temperature (Thermistor) read out.
Data stored in internal non-volatile
memory
Portable and robust for using in Field
APPLICATION
To monitor water level in Bore
wells & Dams.To study propagation of cracks.
Frequency Range 400 to 6000 Hz
Excitation
Resolution
Temperature Range
Temperature Accuracy
Battery Type
Battery Life
Display
Data Transfer Port
Data Transfer Media
Store Data
IP Rating
5 V Square Wave
0.01 Hz
-20 to ± 50ºC
± 1ºC
3 × AA Alkaline Battery
1 Year
16×2 Character LCD
USB 2.0
USB 2.0 Pen Drive
.CSV (Microsoft Excel)
IP 65
DigiLog Vibrating Wire Read Out
Cum Logger (Piezometer) MODEL NO. VI-PM-DIGI-1401
Statometer Acoustic
DWLR ( Piezometer)
Data transmitted through to a cloud
server through GPRS.
Quick custom & valuable insight
with interactive dashboard.
Operation & automation through
intelligence decision making.
Non Contact Device
& Easy Customization.
Frequency Setup.
No Effect on Water Quality.Low Maintenance & Real Time Data &
Easy Data Collection.
Secure Cloud
Data Storage.
Dashboard with
Analytical Tool.
Material
Protection
All weather resistant
ABS + PU
Splash Proof
Battery
Operation Without
Charging
Li-Ion (7.4 V 300 mAH)
~ 5 Days Operation
Charging
Power Supply Adaptor
Recommended Solar Panel
Solar Panel or AC/DC
Adaptor
12 V , 3A DC
> 20 W
Accuracy ± 0.02 to ± 0.05 m
Sensor Interface
Telemetry GPRS/GSM
GPS Accuracy 10 Meter
UART
MODEL NO. VI-DWLR-10Easy Installation.
Plug & Play with
GPS (Optional)Solar Ready &
Resolution 0.001 m
Measurement Frequency
SPECIFICATION
FEATURE
SPECIFICATION
SPECIFICATION
WORKING
PRESSURE TRANSMITTER
(BLIND)
MODEL NO. VI-PTB-SPT-21 Application Temp.
Diaphragm Power supply
Accuracy
Connection
Compensated
Temp.
30 - 80°C
SS 316L 12 - 28 V DC
±0.5% of FS
G1/4male thread
0 - 50°C
Housing SS 304
Output
Range0.1 ..0?0.01..100MPa
(1….0?0.1 ..1000bar)
4 – 20mA
(two wire)
Protection class IP 65
Electrical
Connection
DIN43650 plug/M12
connector
DIGITAL PRESSURE TRANSMITTER
MODEL NO. VI-DPT-SPT-22
SMART PRESSURE TRANSMITTER
MODEL NO. VI-SPT-22Z
POWER OUTPUT - 4 - 20 mA POWER OUTPUT - 4 - 20 mA + RS 485
Application Temp.
Diaphragm Power Supply
Accuracy
Connection
Compensated
Temp.
- 30 - 80°C
SS 316L 18 - 36V DC
±0.2% FS /
±0.5% FS (Optional)
G1/4” male thread
0 - 50°C
Over Pressure 2 x FS
Output
Range-0.1 ..0?0.01..100MPa
(1….0?0.1 ..1000bar)
4-20mA (2 wire) /
0/1?5/10V DC (3 wire)
Display -1999 to 9999
Indicator 4 digit LCD
Sealing Gasket Viton
FEATURES
Aluminum Alloy housing in IP 65
Reversed signal polarity
Overcurrent and Overvoltage
protection
Offset and Full scale adjustable
LCD Indicator
SPECIFICATION
SPECIFICATION
MULTI-LAYER LIQUID
ANALYZER
MODEL NO. VI-MLA-GD-6800
Measurement
Range
Resolution
Output
Interface
Accuracy ±30mm
Cable entry2 nos. M
20 x 1.5 sq.mmMeasurement
interval20 minutes
0 - 20 Meter
10 mm
RS 485 baud rate 4800 bps,
4 channel 4-20mA
One RS 485 and four 4-20mA to
exchange data with monitoring center
Real-time measurement,
data storage, recording and playback
High temperature and
alkali resistance
With Probe and cable
self-cleaning function
With self-diagnostic
and alarm function
7” colour LCD screen withHigh precision and High reliability
Maintenance period - Reagent replacement
once every month
IIoT Solution For Optimizing Your Waste Water Treatment Process Form Anywhere
Built on reputed cloud platform, Plant MIS leverages
Industry 4.0 technologies to improve your
process and maintenance effectiveness.
Our Plant MIS solution brings all plant data including
context information like plans, documents &
drawing and bench marks to your palm, enabling you
to take effective decisions quickly.
Ÿ Process monitoring
Ÿ Machine performance monitoring
Ÿ Energy Management
Applications
Data can be collected Automatically from
Ÿ Quality assurance & compliance.
Ÿ Reporting Compliance.
Ÿ Instruments - Pressure, Flow, Temperature, Level, pH.
Ÿ PLC/DCS
Ÿ Motor, Compressor, Transformers.
Ÿ SCADA
Ÿ Tank Aerators & Energy Meters
Ÿ Containers, Tankers, Trucks.
Monitor & optimize treatment
24x7 from anywhere view KPIs,
Gaps, Root Cause,
History & trends.
Optimize Treatment
Reduce Downtime
Get instant alerts of machine
breakdowns, events or deviations
to right persons.
Improve team Effectiveness
& Morale
Reduce Energy Use
Analyze energy consumption process
wise equipments wise & batch wise.
Implement conservation measures
and record outcomes.
Improve Machine Health
Analyze machine health with
historical an real time data to
improve maintenance
planning & execution.
Plant MIS
SPECIFICATION
FEATURES
Website:www.vexl.in
Jamul
Bhatapara
Kymore
Neemuch
Wadi
Chaibasa
Chandrapur
Damodar
Gagal
Bargarh
Sindri
Agartala
Sewagram
Saurashtra
Marwar Mundwa
Maihar
Roorkee
OUR OFFICES ACROSS THE COUNTRY
Delhi
Punjab
Bhopal
Satna
Panagarah
Raigarh
Bhilai
Sambalpur
Udaipur
Vapi
Kodinar
Igatpuri
Hyderabad
Bellary
FEW INSTALLATION ACROSS THE COUNTRY
Indore
Chennai
BSNL
Vikash NICMAR Emami
IL & FS
MP Birla Group