village centre apartments - brewer, me ©2017 passive ...€¦ · variesby climate. 2.54:...

57
©2017 Passive House Institute US | PHIUS 1 Village Centre Apartments - Brewer, ME

Upload: others

Post on 13-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

©2017 Passive House Institute US | PHIUS 1Village Centre Apartments - Brewer, ME

Page 2: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

DESIGN &VERIFICATION TOOLS, MODELING

PROTOCOLS

Page 3: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

WHOLE BUILDING ENERGY BALANCE

3© 2017 PHIUS

PHPPWUFI® Passive

WUFI® Plus

Page 4: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Demands, Peaks, Site & Primary EnergyAnnual Demand [kBTU/yr.ft2]: Space conditioning energy consumed over the course of the year, delivered by the equipment to the space.

Peak Load [BTU/hr.ft2]: Space conditioning requirement during the peak climate conditions (average over the worst 24 hours). Determines the size of the mechanical system.

Site Energy [kWh/person.yr] OR [kBTU/yr.ft2]: Total energy consumed over the course of the year, including space conditioning, hot water, plug loads, lighting, appliances, systems, etc. (Excludes electrical vehicle charging energy, and ligthing energy specific to vehicle parking areas)*No requirement for PHIUS+ Certification

Source (Primary) Energy [kWh/person.yr] OR [kBTU/yr.ft2]: Site energy as described above, multiplied by the source/primary energy factor for the specific fuel type used. Ex: Electricity has a PE factor of 3.16 kWh/kWh (generation at the source vs use on site)

TERMINOLOGY

©2017 Passive House Institute US | PHIUS 4

Page 5: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

CERTIFICATION TARGET DIFFERENCES

©2016 Passive House Institute US | PHIUS 5

PHIUS+ 2015 PHI

Annual Heat Demand(kBTU/ft2.yr)

Varies by Climate 4.75

Annual Heating Load(BTU/ft2.hr)

Varies by Climate 3.14

Annual Cooling Demand(kBTU/ft2.yr)

Varies by Climate 4.75(+ allowance for latent)

Annual Cooling Load (BTU/ft2.hr)

Varies by Climate 2.54

Airtightness *0.05 cfm/ft2

(Based on Envelope Area)0.6 ACH50

(Based on Net Volume)

Source Energy Factor(Residential)

6,200 kWh/person.yr 38 kBTU/ft2.yr

*0.08 cfm/ft2 for non-combustible construction >5 stories

Page 6: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

PASSIVE STANDARDS IN VARYING CLIMATES

CLIMATE SPECIFIC METRICS

©2017 Passive House Institute US | PHIUS 6

Page 7: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

CERTIFICATION PROTOCOL DIFFERENCES

©2016 Passive House Institute US | PHIUS 7

PHIUS+ 2015 PHI

Internal Heat Gains(Residential)

VariesCalculated

0.67 BTU/hr.ft2

(2.1 W/m2)Default

Square Footage Interior Conditioned Floor Area (iCFA)

Treated Floor Area (TFA)

Occupancy # Bedrooms + 1 TFA ÷ 376.7ft2

(TFA ÷ 30m2)

Residential Lighting 80% RESNET Lighting Assumptions

*11W light x 8 hrs/day x Occupancy

Residential Miscelleneous Electric Loads

(MELS)

80% RESNET MELSAssumptions

**80W x 1.5 hrs/day x Occupancy+

50 kWh x Occupancy

Source Electric Energy Factor 3.16 kWh/kWh(US Average)

2.6 kWh/kWh(German Average)

*Assumes one light on per person at a time**Reference: 25” color TV consumes 150W/hr

Page 8: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

3 Protocols Tested + 1 Hypothetical Adjusted Model

ASHARE 90.1 -2010Appendix G Baseline

PHI PHIUS+ 2015 PHIUS+ 2015 Adjusted

Roof R-value by Climate Zone from Table 5.5

Same as Designed Same as Designed Same as Designed

Walls R-value by Climate Zone from Table 5.5

Same as Designed Same as Designed Same as Designed

Windows U-Value/SHGC by ClimateZone from Table 5.5

Same as Designed Same as Designed Same as Designed

Area Same as PHIUS+ 2015 TFA iCFA iCFA

Lighting RESNET Values PHI Defaults 80% RESNET Values 80% RESNET Values

MELS RESNET Values PHI Defaults 80% RESNET Values 80% RESNET Values

HVAC 50% Efficient ERVH/AC – Same as Designed

Same as Designed Same as Designed System Efficiencies adjusted

DHW 140F Supply TempSame gal/person/day as

PHI/PHIUS

120F Supply Temp6.6 gal/person/day

120F Supply Temp6.6 gal/person/day

Varies by project

Occupancy Same as PHIUS+ 2015 376.7sf/person Number Bedrooms + 1 Same as PHIUS+ 2015

Page 9: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

CERTIFICATION PROTOCOL DIFFERENCES

©2016 Passive House Institute US | PHIUS 9

Comparison Evaluation of ASHRAE 90.1 Appendix G vs. Passive Househttps://www.nyserda.ny.gov/About/Publications/EA-Reports-and-Studies/Energy-Efficiency-Services-ReportsImage from blog post - http://blog.phius.org/comparing-ashrae-90-1-appendix-g-phius-passivhaus-methods-and-standards/

Page 10: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

CERTIFICATION PROTOCOL DIFFERENCES

©2016 Passive House Institute US | PHIUS 10

Base-Case Building

Page 11: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

CERTIFICATION PROTOCOL DIFFERENCES

©2016 Passive House Institute US | PHIUS 11

Most Improved Building

Page 12: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Three Case Studies

Uptown Lofts Knickerbocker Commons

Orchards at Orenco Phase 1

Location Pittsburgh, PA Brooklyn, NY Hillsboro, OR

Square Footage (Gross)

25,000 ft2 36,350 ft2 54,700 ft2

Number of Units 24 24 57

Modeled Occupancy 52 (PHI)48 (PHIUS+ 2015)

71 (PHI)72 (PHIUS+ 2015)

113 (PHI)131 (PHIUS+ 2015)

Actual Occupancy 24 64 ?

PHIUS+ Project # 1188 1274 1203

Page 13: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Three Case Studies

Uptown Lofts Knickerbocker Commons

Orchards at Orenco Phase 1

Location Pittsburgh, PA Brooklyn, NY Hillsboro, OR

Square Footage (Gross)

25,000 ft2 36,350 ft2 54,700 ft2

Number of Units 24 24 57

Modeled Occupancy 52 (PHI)48 (PHIUS+ 2015)

71 (PHI)72 (PHIUS+ 2015)

113 (PHI)131 (PHIUS+ 2015)

Actual Occupancy 24 64 ?

PHIUS+ Project # 1188 1274 1203

Page 14: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

UptownLofts

Page 15: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Things to keep in mind

• Site Energy analyzed• All electricity monitored together (includes all

HVAC, hot water usage, lighting and MELs)• Heat pumps (heating/cooling) in apartments• Direct Electric baseboards in common stairs• HRV• Direct Electric WH

Uptown Lofts

Page 16: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

5,000

10,000

15,000

20,000

25,000

30,000

35,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Monitored (2016) Modeled - PHIUS+ 2015 Modeled - PHI Standard

Mon

thly

(kW

h)

Page 17: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

5,000

10,000

15,000

20,000

25,000

30,000

35,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Monitored (2016) Monitored (2017) Modeled - PHIUS+ 2015 Modeled - PHI Standard

Mon

thly

(kW

h)

Page 18: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

5,000

10,000

15,000

20,000

25,000

30,000

35,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Monitored (2016) Monitored (2017) Modeled - PHIUS+ 2015 Modeled - PHI Standard

Mon

thly

(kW

h)

7,000kWh

8,500kWh7,900kWh

Page 19: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Two Meters

• Tenant Meter: Unit Plug loads/electricity, Unit Lighting & Fans for Heating/Cooling

• House Meter: Hallway/Stairwell/Exterior Lighting, 1st Floor Office Plug Loads, Laundry, Heat Pumps, Hot water tanks, all Ventilation

Uptown Lofts

Page 20: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

5,000

10,000

15,000

20,000

25,000

30,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Tenant Meters - Monitored (2016) Tenant Meters - PHIUS+ 2015 Modeled House Meter - Monitored (2016)

House Meter - PHIUS+ 2015 Modeled Tenant Meters - Monitored (2017) House Meter - Monitored (2017)

Mon

thly

(kW

h)

Page 21: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

500

1,000

1,500

2,000

2,500

3,000

3,500

4,000

4,500

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Tenant Meters - Monitored (2016) Tenant Meters - PHIUS+ 2015 Modeled Tenant Meters - Monitored (2017)

Mon

thly

(kW

h)

Page 22: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

500

1,000

1,500

2,000

2,500

3,000

3,500

4,000

4,500

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Tenant Meters - Monitored (2016) Tenant Meters - PHIUS+ 2015 Modeled Tenant Meters - Monitored (2017)

Mon

thly

(kW

h)

Page 23: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

5,000

10,000

15,000

20,000

25,000

30,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Tenant Meters - PHIUS+ 2015 Adj. - 2017 House Meter - Monitored (2017) House Meter - Monitored (2016)

Mon

thly

(kW

h)

Page 24: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

5,000

10,000

15,000

20,000

25,000

30,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Tenant Meters - Monitored (2016) Tenant Meters - PHIUS+ 2015 Modeled House Meter - Monitored (2016)

House Meter - PHIUS+ 2015 Modeled Tenant Meters - Monitored (2017) House Meter - Monitored (2017)

Mon

thly

(kW

h)

Page 25: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

PHIUS+ 2015 – Adjusted Model

• Mean Temperatures Adjusted (2016 & 2017)• Actual Occupancy• Unit MELS/Lighting Reduced• Thermostats set to 80F (Winter) 72F (Summer)• Doubled Hot Water Usage• Eliminated Summer Natural Ventilation• Heat Pumps Malfunction? (2.7 COP to 1.5

COP)

Uptown Lofts

Page 26: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

5,000

10,000

15,000

20,000

25,000

30,000

35,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Monitored (2016) Monitored (2017)Modeled - PHIUS+ 2015 Adj - 2016 Modeled - PHIUS+ 2015Modeled - PHI Standard Modeled - PHIUS+ 2015 Adj - 2017

Mon

thly

(kW

h)

Page 27: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

5,000

10,000

15,000

20,000

25,000

30,000

35,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Monitored (2016) Modeled - PHIUS+ 2015 Adj - 2016

Modeled - PHIUS+ 2015 Modeled - PHI Standard

Mon

thly

(kW

h)

Page 28: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

5,000

10,000

15,000

20,000

25,000

30,000

35,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Monitored (2017) Modeled - PHIUS+ 2015

Modeled - PHI Standard Modeled - PHIUS+ 2015 Adj - 2017

Mon

thly

(kW

h)

Page 29: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

5,000

10,000

15,000

20,000

25,000

30,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Tenant Meters - Monitored (2016) Tenant Meters - PHIUS+ 2015 Modeled Tenant Meters - PHIUS+ 2015 Adj. - 2016House Meter - Monitored (2016) House Meter - PHIUS+ 2015 Modeled House Meter - PHIUS+ 2015 Adj. - 2016Tenant Meters - Monitored (2017) House Meter - Monitored (2017) Tenant Meters - PHIUS+ 2015 Adj. - 2017House Meter - PHIUS+ 2015 Adj. - 2017

Mon

thly

(kW

h)

Page 30: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

500

1,000

1,500

2,000

2,500

3,000

3,500

4,000

4,500

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Tenant Meters - Monitored (2016) Tenant Meters - PHIUS+ 2015 Modeled Tenant Meters - PHIUS+ 2015 Adj. - 2016

Mon

thly

(kW

h)

Page 31: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

500

1,000

1,500

2,000

2,500

3,000

3,500

4,000

4,500

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Tenant Meters - PHIUS+ 2015 Modeled Tenant Meters - Monitored (2017) Tenant Meters - PHIUS+ 2015 Adj. - 2017

Mon

thly

(kW

h)

Page 32: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

5,000

10,000

15,000

20,000

25,000

30,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

House Meter - Monitored (2016) House Meter - PHIUS+ 2015 Modeled House Meter - PHIUS+ 2015 Adj. - 2016

Mon

thly

(kW

h)

Page 33: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Uptown Lofts

-

5,000

10,000

15,000

20,000

25,000

30,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

House Meter - PHIUS+ 2015 Modeled House Meter - Monitored (2017) House Meter - PHIUS+ 2015 Adj. - 2017

Mon

thly

(kW

h)

Page 34: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

35.0

22.5

28.7

22.7

19.5

15.2

0

5

10

15

20

25

30

35

40

kBtu/sf.yr

Site Energy: Monitored vs Adjusted Models

Monitored (Electricity) kWh (2016) Modeled - PHIUS+ 2015 Adj - 2016

Monitored (Electricity) kWh (2017) Modeled - PHIUS+ 2015 Adj - 2017

Modeled - PHIUS+ 2015 Modeled - PHI Standard

Site

Ene

rgy

Com

paris

on

Uptown Lofts

Page 35: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Three Case Studies

Uptown Lofts Knickerbocker Commons

Orchards at Orenco Phase 1

Location Pittsburgh, PA Brooklyn, NY Hillsboro, OR

Square Footage (Gross)

25,000 ft2 36,350 ft2 54,700 ft2

Number of Units 24 24 57

Modeled Occupancy 52 (PHI)48 (PHIUS+ 2015)

71 (PHI)72 (PHIUS+ 2015)

113 (PHI)131 (PHIUS+ 2015)

Actual Occupancy 24 64 ?

PHIUS+ Project # 1188 1274 1203

Page 36: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

KnickerbockerCommons

Page 37: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Things to keep in mind

• Project did not go through on-site Verification to become a Certified Passive House Project

• Site Energy analyzed (converted to kWh)• Electricity and gas monitored separately

– Electric: cooling, lighting, MELs– Gas: heating, water heating, dryers

• Hydronic Heating/water heater system• ERV• Individual AC units for cooling

Knickerbocker Commons

Page 38: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Knickerbocker Commons

-

20,000

40,000

60,000

80,000

100,000

120,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Monitored - 2015 Monitored - 2016 Monitored - 2017 Modeled - PHIUS+ 2015 Modeled - PHI Standard

Mon

thly

(kW

h)

Page 39: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Things to keep in mind

• Electric Meter– AC Units– Lighting– MELS

• Natural Gas Meter– Hydronic Heating– Water Heaters– Exhaust Clothes Dryers

Knickerbocker Commons

Page 40: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Knickerbocker Commons

-

2,000

4,000

6,000

8,000

10,000

12,000

14,000

16,000

18,000

20,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Electricity: Monitored vs Modeled

Monitored Electricity - 2015 Monitored Electricity - 2016 Monitored Electricity - 2017

Modeled Electricity - PHIUS+ 2015 Modeled - PHI Standard

Mon

thly

(kW

h)

Page 41: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Knickerbocker Commons

-

50,000

100,000

150,000

200,000

250,000

300,000

350,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Natural Gas: Monitored vs Modeled

Monitored Nat. Gas - 2015 Monitored Nat. Gas - 2016 Monitored Nat. Gas - 2017

Modeled Nat. Gas - PHIUS+ 2015 Modeled Nat. Gas - PHI Standard

Mon

thly

(kBT

U)

Page 42: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

PHIUS+ 2015 – Adjusted Model

• Mean Temperatures Adjusted (2016 & 2017)• Thermostats set to 77F (Winter)• Actual Occupancy• Doubled Hot Water Usage• 0.5 ACH50 -> 3 ACH50

– (Leaky AC Units/Open Windows?)

• Lower Efficiency Boilers

Knickerbocker Commons

Page 43: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Knickerbocker Commons

-

20,000

40,000

60,000

80,000

100,000

120,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Monitored - 2015 Monitored - 2016 Monitored - 2017

Modeled - PHIUS+ 2015 Adjusted Modeled - PHIUS+ 2015 Modeled - PHI Standard

Mon

thly

(kW

h)

Page 44: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Knickerbocker Commons

-

5,000

10,000

15,000

20,000

25,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Electricity: Monitored vs Modeled

Monitored Electricity - 2015 Modeled Electricity - PHIUS+ 2015 AdjustedModeled Electricity - PHIUS+ 2015 Modeled - PHI StandardMonitored Electricity - 2016 Monitored Electricity - 2017

Mon

thly

(kW

h)

Page 45: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Knickerbocker Commons

-

50,000

100,000

150,000

200,000

250,000

300,000

350,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Natural Gas: Monitored vs Modeled

Monitored Nat. Gas - 2015 Monitored Nat. Gas - 2016 Monitored Nat. Gas - 2017

Modeled Nat. Gas - PHIUS+ 2015 Adjusted Modeled Nat. Gas - PHIUS+ 2015 Modeled Nat. Gas - PHI Standard

Mon

thly

(kBT

U)

Page 46: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Knickerbocker Commons

39.2

51.7

33.3

29.0

20.7

13.0

0

10

20

30

40

50

60

kBtu/sf.yr

Site Energy: Monitored vs Adjusted Models

Monitored - 2015 Monitored - 2016 Monitored - 2017

Modeled - PHIUS+ 2015 Adjusted Modeled - PHIUS+ 2015 Modeled - PHI Standard

Site

Ene

rgy

Com

paris

on (k

BTU

/sf)

Page 47: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Three Case Studies

Uptown Lofts Knickerbocker Commons

Orchards at Orenco Phase 1

Location Pittsburgh, PA Brooklyn, NY Hillsboro, OR

Square Footage (Gross)

25,000 ft2 36,350 ft2 54,700 ft2

Number of Units 24 24 57

Modeled Occupancy 52 (PHI)48 (PHIUS+ 2015)

71 (PHI)72 (PHIUS+ 2015)

113 (PHI)131 (PHIUS+ 2015)

Actual Occupancy 24 64 ?

PHIUS+ Project # 1188 1274 1203

Page 48: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Orchards at Orenco I

Page 49: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

Things to keep in mind

• Site Energy analyzed (converted to kWh)• Electricity monitored separately• Heat pumps (heating/cooling) in apartments

w/ direct electric backup• HRV• Natural Gas WH• Natural Gas Clothes Dryers

Orchards at Orenco I

Page 50: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

-

5,000

10,000

15,000

20,000

25,000

30,000

35,000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Site Energy: Monitored vs Modeled

Monitored (Electricity + Gas) kWh Modeled - PHIUS+ 2015 Modeled - PHI Standard

Mon

thly

(kW

h)

Orchards at Orenco I

Page 51: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

-

2,000

4,000

6,000

8,000

10,000

12,000

JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

Site Energy: Monitored vs PHIUS+ 2015 Predicted

Monitored - Unit Electric Heating Predicted - Unit Electric HeatingMonitored - Heating/Cooling Heat Pumps + ERV Predicted - Heating/Cooling Heat Pumps + ERVMonitored - Hot Water - Gas Predicted - Hot Water - GasMonitored - Clothes Dryers - Gas Predicted - Clothes Dryers - GasMonitored - Electricity - Apts Predicted - Electricity - AptsMonitored - Electricity - Commons Predicted - Electricity - Commons

Mon

thly

(kW

h)

Orchards at Orenco I

Page 52: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

-

2,000

4,000

6,000

8,000

10,000

12,000

JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

Site Energy: Monitored vs PHIUS+ 2015 Predicted

Monitored - Electricity - Apts Predicted - Electricity - Apts

Monitored - Electricity - Commons Predicted - Electricity - Commons

Mon

thly

(kW

h)

Orchards at Orenco I

Page 53: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

-

2,000

4,000

6,000

8,000

10,000

12,000

JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

Site Energy: Monitored vs PHIUS+ 2015 Predicted

Monitored - Heating/Cooling Heat Pumps + ERV Predicted - Heating/Cooling Heat Pumps + ERVMonitored - Hot Water - Gas Predicted - Hot Water - Gas

Mon

thly

(kW

h)

Orchards at Orenco I

Page 54: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

-

500

1,000

1,500

2,000

2,500

3,000

JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

Site Energy: Monitored vs PHIUS+ 2015 Predicted

Monitored - Unit Electric Heating Predicted - Unit Electric HeatingMonitored - Clothes Dryers - Gas Predicted - Clothes Dryers - Gas

Mon

thly

(kW

h)

Orchards at Orenco I

Page 55: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

21.8 22.3

15.4

0

5

10

15

20

25

kBtu/sf.yr

Site Energy: Monitored vs Adjusted Models

Monitored (Electricity + Gas) kWh Modeled - PHIUS+ 2015 Modeled - PHI Standard

Site

Ene

rgy

Com

paris

on

Orchards at Orenco I

Page 56: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56

HDD

65

EUI (kBtu/ft2.yr)

Site Energy Use Index

Village Centre Apts

Village Centre Apts (P+15)

Uptown Lofts (2016)

Uptown Lofts (2017)

Uptown Lofts (P+15)

Knickerbocker Commons (2015)

Knickerbocker Commons (2016)

Knickerbocker Commons (2017)

Knickerbocker Commons (P+15)

Orchards I

Orchards I (P+15)

Stellar Apartments

Stellar Apartments (P+15)

Page 57: Village Centre Apartments - Brewer, ME ©2017 Passive ...€¦ · Variesby Climate. 2.54: Airtightness *0.05 cfm/ft2 (Based on Envelope Area) 0.6 ACH50 (Based on Net Volume) Source

PASSIVE BUILDING PART OF THE SOLUTION

57©2017 Passive House Institute US | PHIUS

James Ortega, Certification Staff

www.PHIUS.org/www.PHAUS.org

Elm Place– Milton, VT