DYNAMIC VISCOSITY
IN PROCESS TO EXCELLENCE WITH
LEMIS PROCESS
Dynamic viscosity is a critical part and an important parameter for qualitative process control of a given liquid. Dynamic viscosity determination is required for wide range of products such as lubricants, oils, fuels etc.
LEMIS process offers the way to optimize your costs without saving on accuracy and repeatability of your measurements!
Our customers say: “to control dynamic viscosity means to control quality of the product”. It means faultless equipment that provides qualitative production, no errors, no downtimes, costs optimization and economy. LEMIS process viscometers range secure stabile continuous control at any conditions. All required measurement methods are supported: continuous in-tank or in-line; repeatable by portable meters (using submersible sensors without sampling or laboratory sensors with sampling). It is not an exaggeration to say that LEMIS process meters can operate everywhere and give the most accurate measurements.LEMIS Process offers a turnkey solution foryour process industry, providing many advantages to you as a customer. An individual approach, flexibility, tailored to your process solutions.
Briefly about companyLEMIS process is located in EU(Riga, Latvia), USA (The Woodlands, TX) and India (Navi Mumbai)
1200 m2 facility in Riga, LATVIA
Complete cycle from conception and development to manufacturing, assembling, testing and shipment
ISO 9001: 2000 certified
Strong sales organization takes out products sales and support worldwide
DC-41 SERIES DC-51 SERIES
VM-250.1 VM-250.2 VM-250.3
VISCOMETERS RANGEDynamic viscosity:
mPa·s
cP
Process temperature:
°C
°F
VC-30
Unique resonant tube technology
The LEMIS process sensor comprises of a vibrating tube sensor, drive electronics and signal processing electronic.
ü Cylinder shape has symmetric geometry
ü Repeatable mechanical manufacturing
ü Repeatable metal structureü Low own mass of the sensorü Washed on either side by
measured liquid eliminates pressure effect
ü Allows both density and viscosity measurement
ü Ni-Span-C material offering low temperature expansion factor
Resonant tube advantages
CONTINUOUS CONTROL METERSIN-TANK MEASUREMENTSDC- 41 SERIES:
F-type,
Installation pack:
Immersion on flexible hawser
R-type,
Installation pack:
Long rigid
immersion
D-type,
Installation pack:
Direct insertion
DC-41 installation model
LOW FLOW RATE CONTINUOUS CONTROL METER VC-30 SERIES
Resonant tube
Measuring chamber
Output and input
VC-30 Inside profile VC-30 is wall-mounted device
Low flow rate
CONTINUOUS CONTROL METERSIN-LINE MEASUREMENTS
DC-51 SERIES
G-type
S-type
T-type
DC-51 G-type installation model
PORTABLE METERS
VM-250.1
VM-250.3
VM-250.2
Forget sampling for VM-250.1and VM-250.2!
Quickly measures dynamic viscosity of a liquid product in
tank.Measures level of liquid
products in the tank.They’re economical and easy to
operate.Calibration couldn’t be
simpler just use standard liquids.
Select a VM version according to the testing depths
you require.
VM-250.1 plunges to 6 meters, while VM-250.2 reportsdynamic viscosity and temperature measurements at
30 meter depths in seconds.Measures highly viscous liquids up to 1200 cP.
CalibrationCalibration of LEMIS process is
performed in-house according
ISO9001:2000 quality
assurance program by using
calibration materials that are
traceable to national standards.
In-house calibration and testing
is performed specified
dedicated calibration protocol
for every standard model of the
sensor. For most applications,
on-site calibration is generally
not required. LEMIS process
sensors allows simple, switch-
and-go field installation.
ApplicationsViscosity and temperature monitoring in storage tanks
Petroleum products, fuels, lubricants, LPG, LNG
Concentrations of acids or corrosive chemical
Food, Dairy & Beverages
Product identification and consistency
Concentration and dilution measurement
Monitoring of reaction end in reactors
In-tank mixing and blending
AdvantagesContinuous measurements
Easy cleaning
High accuracy
Simple installation
Suitable for very viscous liquids
Wide range of applications
Rigorous factory calibration
Automatic temperature compensation
Compact design
Operating rangesDynamic viscosity:0 to 1200 mPa·s (0 to1200 cP)
ProcessTemperature:-200°C to +200°C (-328°F to +392°F)
Accuracy
Dynamic viscosity:±1% (measured value)
Temperature:±0.1°C (±0.2°F)