vistor the new toric iol by hanita lenses sept 2013
TRANSCRIPT
![Page 1: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/1.jpg)
VisTorThe new Toric IOL by Hanita Lenses
Sept 2013
![Page 2: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/2.jpg)
Astigmatism - The cornea has different radii (Dpt) in different meridians, causing the focus to spread between two points.
Definition
![Page 3: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/3.jpg)
Effect on vision
The image may be clearly focused on the retina in the horizontal plane, but not in the vertical plane:
Or vice-versa:
Or at any other angle…
![Page 4: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/4.jpg)
IOLMaster Topographer
Diagnosis: Regular astigmatism
![Page 5: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/5.jpg)
IOLMaster Topographer
Diagnosis: Irregular Astigmatism
![Page 6: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/6.jpg)
Astigmatic cornea can be represented as cylinder, causing vertical rays focus differently from horizontal ones, leading to dispersion of focus and blurry image quality. This can be corrected by placing additional cylinder of the same power, rotated by 900.This is the principle of action of the toric IOL. The IOL corrects the dispersion induced by the cornea, focusing the rays in one point on the retina and restoring the sharp image quality.
Correction of astigmatism by IOL
![Page 7: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/7.jpg)
Astigmatic cornea can be represented as cylinder, causing vertical rays focus differently from horizontal ones, leading to dispersion of focus and blurry image quality. This can be corrected by placing additional cylinder of the same power, rotated by 900.This is the principle of action of the toric IOL. The IOL corrects the dispersion induced by the cornea, focusing the rays in one point on the retina and restoring the sharp image quality.
Correction of astigmatism by IOL
![Page 8: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/8.jpg)
VisTor Platform
3600 enhanced square edge decrease PCO
Visible axis marking even for small pupils
Excellent stability in the capsular bag endurance to rotation, tilt & decentration .
Injection through 1.8 mm incision
![Page 9: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/9.jpg)
Aspheric optics
Standard corneal spherical aberration +0.27µ, corrected by natural lens
Designed using Arizona Uni. model, with statistical eye data of old population
Anterior toric surface, posterior aspheric surface
IOL asphericity -0.14, leaving residual +0.13µ for better contrast sensitivity, shown in Prof. Tetz study
Total correction of Toric aberrations
![Page 10: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/10.jpg)
Raw material
Violet light blocker equivalent to natural chromophore .
>10 years clinical experience and > 1 million implantations of Hanita’s IOLs
Hydrophilic acrylic 25% water, produced by Benz R&D (USA)
Better transmission of blue light than yellow IOLs – important for dim light situationsHigh Abbe number, low Refractive index (1.46 @35o) means less chromatic aberrations & higher contrast sensitivity
![Page 11: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/11.jpg)
Toric Calculator order form,on www.hanitalenses.com
![Page 12: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/12.jpg)
Toric Calculator, on www.hanitalenses.com
![Page 13: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/13.jpg)
Germany, France, Israel, Colombia, Czech republic
9 Participating centers
180 Total no of eyes (planned)
Pre-op, surgery, 1 & 3 months
Follow-up visits
45 Implanted eyes
14 Eyes with follow-up >1M
Clinical Study + Post marketing evaluation
![Page 14: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/14.jpg)
Clinical Study preliminary results (Sept 2013)
Results
Preliminary study for :rotational stability
&Refraction accuracy
![Page 15: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/15.jpg)
Clinical Study preliminary results (Sept 2013)
PreOp PostOp0.00
0.50
1.00
1.50
2.00
2.50Cylinder Pre-Op vs. Post-Op
Refr
activ
e cy
linde
r (n=
14)
70% of patients obtained Cylinder under 0.5D post op
![Page 16: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/16.jpg)
Clinical Study preliminary results (Sept 2013)
≤ -1.5
-1.5 to -1
-1 to -0
.5
-0.5 to +0
.5
+0.5 to
+1
+1 to
+1.5
+1.5<
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
Spherical equivalent refraction Post-Op (1-3 Months)
Spherical Equivalent Refraction - Targeted refraction (Diopters)
Perc
enta
ge o
f pati
ents
(n=1
4)
![Page 17: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/17.jpg)
Clinical Study preliminary results (Sept 2013)
1 ≤
0.8 to 1
0.6 to 0.8
0.4 to 0.6
0.2 to 0.4
0 to 0.2
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Visual Acuity Post-Op (1-3 Months)
UCVA
BCVA
Visual Acuity (Decimal)
Perc
enta
ge o
f pati
ents
(n=
14)
*Patient with refraction of: Sph=0, Cyl=0
*
![Page 18: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/18.jpg)
Clinical Study preliminary results (Sept 2013)
≤ 33 to
55 to
77 to
9 9<0%
10%
20%
30%
40%
50%
60%
70%
Rotational Stability (1-3 Months)
Deviation from implanted position (Degrees)
Perc
enta
ge o
f pati
ents
(n=1
4)
* Significant rotation (>15º) has occurred in 2 eyes with high AL (>26mm). Both cases are not included above due to short follow-up time (<1M). Due to this, for improved stability in long eyes, IOLs below 16 dpt are provided with external diameter of 11.5mm
![Page 19: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/19.jpg)
Preliminary conclusions (Sept 2013)
- The Hanita VisTor is a MICS lens with toric optics
- It can be implanted through 1.8 mm incisions, with
no impairment of existing corneal astigmatism
- It can be easily positioned, by clockwise and
counterclockwise rotation
- For improved stability in long eyes, IOLs below 16 dpt are provided with external diameter of 11.5mm
- Precise refraction and correction of astigmatism
![Page 20: VisTor The new Toric IOL by Hanita Lenses Sept 2013](https://reader035.vdocuments.net/reader035/viewer/2022081502/551bf64c5503469e4f8b46ac/html5/thumbnails/20.jpg)