3
VAPOUR LIQUID EQUILIBRIUM UNIT Equipment for Engineering Education & Research SOLTEQ ® MODEL: BP 16 T his Vapor-Liquid Equilibrium Unit (Model: BP 16) is a bench top unit designed for students to investigate the relationship between vapor and liquid at equilibrium for any binary system as well as for multi- component system. Students may run the unit at atmospheric pressure (i.e. 0 bar (g)) or at an elevated pressure. The unit consists of mainly a stainless steel evaporator fitted with electrical heater and electronic sensors for the measurement of pressure and temperatures of liquid and vapour. A stainless steel coil type heat exchanger is attached at the top of the evaporator. Digital displays are provided for students to monitor the temperature and pressure of the vapour in the vessel. A temperature controller is also provided for the purpose of setting and adjusting the equilibrium temperature. The unit comes with a pressure relief valve for safety purposes. The unit is also well insulated in order to minimize heat losses. Feed port and sampling ports for both liquid and vapour are also provided. EXPERIMENTAL CAPABILITIES The vapor-liquid relationship at equilibrium for binary system and multi-component system at atmospheric pressure as well as at an elevated pressure. The effect of initial mixture composition upon the boiling temperature and vapour liquid phase compositions. Determination of minimum boiling point of a binary mixture. The effect of adding non-volatile salt on the phase compositions. Vapor pressure curve at high pressure.

Upload: farhan-ahmad

Post on 16-Oct-2014

168 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: vle solteq

VAPOUR LIQUID EQUILIBRIUMUNIT

Equipment for Engineering Education & ResearchSOLTEQ®

MODEL: BP 16

This Vapor-Liquid Equilibrium Unit (Model: BP 16) is a bench top unit designed for students to investigate

the relationship between vapor and liquid at equilibrium for any binary system as well as for multi-

component system. Students may run the unit at atmospheric pressure (i.e. 0 bar (g)) or at an elevated

pressure.

The unit consists of mainly a stainless steel evaporator

fitted with electrical heater and electronic sensors for

the measurement of pressure and temperatures of liquid

and vapour. A stainless steel coil type heat exchanger

is attached at the top of the evaporator. Digital displays

are provided for students to monitor the temperature

and pressure of the vapour in the vessel. A temperature

controller is also provided for the purpose of setting and

adjusting the equilibrium temperature. The unit comes

with a pressure relief valve for safety purposes. The

unit is also well insulated in order to minimize heat

losses. Feed port and sampling ports for both liquid and

vapour are also provided.

EXPERIMENTAL CAPABILITIES

♦ The vapor-liquid relationship at equilibrium for binary

system and multi-component system at

atmospheric pressure as well as at an elevated

pressure.

♦ The effect of initial mixture composition upon the

boiling temperature and vapour liquid phase

compositions.

♦ Determination of minimum boiling point of a binary

mixture.

♦ The effect of adding non-volatile salt on the phase

compositions.

♦ Vapor pressure curve at high pressure.

Page 2: vle solteq

SOLTEQ

Equipment for Engineering Education & ResearchSOLTEQ®

SPECIFICATIONS

The Vapor-Liquid Equilibrium Unit (Model: BP 16)

comes complete with the following components:

a) Test Rig:

Epoxy coated steel bench with lockable castors.

b) Evaporator:

Cylindrical vessel (jacketed)

Material: stainless steel

Nominal capacity: 6 liter

Tubular heater: 2 kW

Insulation

c) Condenser:

Coil type heat exchanger

Material: stainless steel

Exchange surface: 0.3 m2

Connections for cooling media

Insulation

d) Temperature controller:

Displays bottom liquid temperature

Limits the max. Operating temperature

e) Pressure relief valve:

0 to 10 bar (g)

f) Sampling Devices:

· Stainless steel cooler for bottom product

sampling

· Stainless steel top product sampling vessel

g) Instrumentations:

Temperature sensors and pressure transducer with

digital indicators

h) Control panel:

Electrical wiring and switches

Temperature controller

Digital displays

i) Operating Limits:

Temperature : max. 200°C

Pressure : max. 10 bar(g)

Coolant pressure : max. 2 bar(g)

REQUIREMENTS

Electrical Supply : 230VAC, 1-phase, 50Hz

Cooling Water : laboratory mains supply

Chemicals : binary mixture (e.g. methanol-

water)

Analytical Equipment : GC or Refractometer for

sample analysis

OVERALL DIMENSIONS

Height : 2.00 m

Width : 1.22 m

Depth : 0.61 m

MANUAL

The unit comes with Operating and Experimental

manuals in English.

TRAINING

Training will be conducted to handing over of the

unit.

Page 3: vle solteq

Our range of teaching equipment can be complemented with our

SOLDAS and SOLCAL software.

SOFTWARE & E - LEARNING

SOLDAS® - Supervisory Control & Data Acquisition

- Data Logging

- Signal Analysis

- Process Control

- Real-Time Display

- Tabulated Results

- Graph of Experimental Results

SOLCAL® - Computer Aided Learning

- Multimedia Features

- Interactive

- Graphic Simulation

- Experiment Result Samples

- Full Experiment Manuals

SOLTEQ®

Contact us for a catalog CD

SOLUTION ENGINEERING SDN. BHD.(Co. No. 174876-M)

Sales Office :

No.3, Jalan TPK 2/4, Taman Perindustrian Kinrara,47100 Puchong, Selangor Darul Ehsan, Malaysia.Tel. No. : +(603) 80758000

Fax. No.: +(603) 80755784

R&D Office :

G-2A, Incubator 3, Technology Park Malaysia,Bukit Jalil, 57000 Kuala Lumpur, Malaysia.Tel. No. : +(603) 8996 0023

Email : [email protected] site : http//www.solution.com.my/

AGENT:

Equipment for Engineering Education & Research

BUATAN MALAYSIA

MSC- StatusCompany