Page 1: VLT® Soft Starter MCD 500pooyeshniroo.com/wp-content/uploads/2016/05/Mcd-500... · 2016-05-10 · VLT® Soft Starter MCD 500 is a total motor starting solution. Current transformers
Page 2: VLT® Soft Starter MCD 500pooyeshniroo.com/wp-content/uploads/2016/05/Mcd-500... · 2016-05-10 · VLT® Soft Starter MCD 500 is a total motor starting solution. Current transformers
Page 3: VLT® Soft Starter MCD 500pooyeshniroo.com/wp-content/uploads/2016/05/Mcd-500... · 2016-05-10 · VLT® Soft Starter MCD 500 is a total motor starting solution. Current transformers

The perfect solution, also for more severe applications:• Pumps• Conveyors• Fans• Mixers• Compressors• Centrifuge• Mill • Saw• And many more

Power range 7.5 – 800 kWVersions for 200–690 VAC

VLT® Soft Starter MCD 500 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles.

The VLT® Soft Starter MCD 500 has a four line graphical display and a logic keypad making programming easy. Advanced setup is possible displaying operational status.

Three menu systems: Quick Menu, Application Setup and Main Menu provide optimum programming approach.

AAC, the Adaptive Acceleration Control automatically employs the best starting and stopping profile for the application.

Adaptive Acceleration Control means, that at each start and stop, the soft starter compares the actual curve with the one defined as preferred, and adjusts its performance next time.

Features Benefits

• AACAdaptiveAccelerationControl • Automatically adapts to the best starting and stopping profile for the application

• AdjustableBusBars,allowfortop,bottom or both (>=360A)

• Space saving, reduced cable cost and easy retrofitting

• DCinjectionbrakingdistributedevenly over three phases

• Reduced installation cost and less stress on the motor

• InsideDelta(6-wireconnection) • Smaller soft starter can be selected for the application

• LogMenus,99EventsandTriplogprovide information on events, trips and performance • Easesanalysisontheapplication

• AutoReset • Lessdowntime

• Jog(slow-speedoperation) • Applicationflexibility

• Second-orderthermalmodel• Allows motor to be used to its full potential

without damage from overloading

• Internalbypasscontactors(<=110kW)

• Savesspaceandwiringcomparedto external bypass

• Verylittleheatdissipateswhenrunning.Eliminatescostlyexternalfans,wiring or bypass contactors

• Auto-start/stopclock • Applicationflexibility

• Compactsize–amongstthesmallest in their class

• Savesspaceincabinetsandotherapplication setups

• 4-linegraphicaldisplay • Optimumprogrammingapproachandsetup for viewing operational status

• Multipleprogrammingsetup (StandardMenu,ExtendedMenu,QuickSet)

• Simplifiestheprogramming,butstillholdingtomaximumflexibility

• Multiple(8)languages • Servingthewholeworld

VLT® Soft Starter MCD 500

Page 4: VLT® Soft Starter MCD 500pooyeshniroo.com/wp-content/uploads/2016/05/Mcd-500... · 2016-05-10 · VLT® Soft Starter MCD 500 is a total motor starting solution. Current transformers

Fully featured Soft Starter formotors up to 800 kW•Totalmotorstartingsolution•Advancedstart,stopandprotection

features•AdaptiveAccelerationControl•InsideDeltaconnection•4linegraphicaldisplay•Multipleprogrammingsetupmenus

Optional:•Modulesforserialcommunication•Remoteoperatorkit•PCsoftware

Specifications

Remote operation kit•Start/stop,reset•LEDforstart,run,trip•Tripcodes•Currentdisplay•Motortemperature display•4–20mAoutput

Supply

Mains voltage(L1,L2,L3)MCD5-xxxx-T5 200VAC~525VAC(±10%)

MCD5-xxxx-T7 380VAC~690VAC(±10%)(earthed star supply system only)

MCD5-xxxx-T7 380VAC~600VAC(±10%)(insidedeltaconnection)Control voltage (A4,A5,A6)CV1(A5,A6) 24VAC/VDC(±20%) CV2 (A5, A6) 110~120VAC(+10%/-15%)CV2(A4,A6) 220~240VAC(+10%/-15%)Mains frequency 50/60Hz(±10%)Rated insulation voltage to earth 600 VACRated impulse withstand voltage 4kV

Form designation Bypassedorcontinuous,semiconductormotorstarterform1

Short circuit capability

Coordination with semiconductor fuses Type 2CoordinationwithHRCfuses Type1MCD5-0021BtoMCD5-0105B prospectivecurrent10kAMCD5-0131BtoMCD5-0245C prospectivecurrent18kAMCD5-0360CtoMCD5-0927C prospective current 85 kAMCD5-1200CtoMCD5-1600C prospectivecurrent100kA

Electromagnetic capability (compliant with EU Directive 89/336/EEC)

EMCEmissions(Terminals13&14) IEC60947-4-2ClassBand LloydsMarineNo.1Specification

EMCImmunity IEC60947-4-2

Outputs

RelayOutputs 10A@250VACresistive,5A @250VACAC15pf0.3

ProgrammableOutputsRelayA(13,14) Normally openRelayB(21,22,24) ChangeoverRelayC(33,34) Normally openAnalogOutput(07,08) 0–20mAor4–20mA(selectable) Maximum load 600Ω(12VDC@20mA)(accuracy±5%)24VDCOutput(16,08)Maximumload 200mA(accuracy±10%)

Environmental

ProtectionMCD5-0021B~MCD5-0105B IP20&NEMA,ULIndoorType1ProtectionMCD5-0131B~MCD5-1600C IP00,ULIndoorOpenTypeOperatingtemperature -10°Cto60°C,above40°CwithderatingStorage temperature -25°Cto+60°COperatingAltitude 0–1000m,above1000mwithderatingHumidity 5%to95%RelativeHumidityPollution degree Pollution Degree 3

Heat DissipationDuring start 4.5wattsperampere

Current rating [A] Weight [kg] Height [mm] Width [mm] Depth [mm]21,37,43and53 4.2

295 150 18368 TBC84,89and105 4.9

131,141,195and215 14.9 438 275 250245 23.9 460 390 279

360,380and428 TBC689 430 302

595,619,790and927 53.11200,1410and1600 120 856 585 364

Dimensions

MP014A02 VLT®isatrademarkofDanfossA/S ProducedbyKKM2008.10