vol-ii concrete work
TRANSCRIPT
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 1/23
CONCRETE WORK
SPECIFICATIONS 9 92
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 2/23
ONT NTS
Page No.
456
ONCRETE WORK.
47
ATERIAL
48
OARSE AGGREGATE
49
DMIXTURES
50
EMENT CONCRETE
50
ROPORTIONING
50
REP ARA TION
50
ORKABILITY
53
RANS PORTA TION
54
LACING
54
OIvlPACnON
54
ONSTRUCTION JOINTS.
54
ONCRETE UNDER SPECIAL CONDITIONS
54
URING
55
55
5
5
57
IME CONCRETE
ROPORTIONING
57
IXING
57
PLACING AND COMPACTION
58lJRING 58
EASUREMENTS
58
ATE
58
EMENT FLY ASH CONCRETE
AMP PROOF COURSE
59
EMENT CONCRETE LAYER
59
URING
59PPLICATION OF HOT BITUMEN
59
ATER PROOFING MATERIALS
59
·4.5.5
MEASUREMENTS
59
43
·4 4/CPWD/ND/92
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 3/23
4 5 6 RATE
ft PPENDIX A
APPENDIX B
ApPENCIX C
APPINDIX D
DETERMINATION OF PARTICLE SIZE
TEST FOR SUFRACE MOISTURE
DETERMINATION OF TEN PRECENT FINE VALUE
SLUMP TEST
59
6
61
6
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 4/23
List of Mandatory Tests
Chapter - 4
Clause /T ,estield/Laboratory
est Procedureinimum
Frequency )ftesting
quantity of
material/work
for carrying
out the test .
4.1.2.2
) Precentage
eneral visualS 2386
s required by
or all
nspection, labor
t.II
ngineer-in-chargeuantities
tory test where
963
equired by the
~ngineer-in-harge or aspedfied
b) Particle
Field or lab.
ppendix A
5 cum
or every sizes required byage
59
45 cum or
distribution
Engineer-iri- part thereofs decided by
Engineer-in-harge
Ten precent
Laboratoryppendix C
5 cumnitial test
Page
60
nd subsequent
test as. when
equired by
E;ngineer-in-
harge
4.2.3
lump Test
~_ ~
Appendix D
5 cum
5
cum or par t
P A hhereof or more frequently as
equired byngineer-in-
Charge
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 5/23
CONCRETE WORK
ST OF BUEREAU OF INDIAN STANDARD CODES
1. 383-1970 Specification for coarse and fine aggregate from Natural Source for Concrete.
2. 456-1978 Code of practice for plain and reinforced concrete.
3. 516-1959 Method of test for strength of concrete
4. 1199-1959 Method of sampling and analysis of concrete
5. 1200 (pt.II) Method of measurement of building and civil
- 1974, engineering work (concrete work)
6. 1322-1982 Specification for bitumen felt for water proofing and damp proofing.
7. 1791-1985 Specification for batch type concrete mixers.
8. 2386-1963 Method of test for aggregate for concrete work.
a) Pt. I Particle size and shape
b) Pt. II Estimation of deleterious materials iind organic impurities
c
Pt. IIi Specific gravity, density,
km
and bulking.
d) Pt. IV Mechanical properties
9. 2505-1980 ,General requirement for concrete vibraln irnirit.. Tsioritype.
1O. 2506-1985 General requirement for screedboar ~,ixj.r :;lct{:\brators.
11. 2645-1975 Specification for integral cement waterpmoHng components.
12. 2686-1977 Specification for cinder as fine aggregate for use in Jime concrete.
13. 3068-1986 Specification for broken burnt (clay) coarse aggregate for use in lime concrete.
14. 3812-1981 Specification for flyash for use as pozzo1anaand admixtures
15. 4656-1968 Specification for fonn vibrators for concrete.
16. 7861-1981 Code of practice for extreme weather concreting (Pt. I) recommended practice
for hot weather concreting.
17. 7861-1975 For cold weather concreting
(Pt. II)
18. 9103-1979 For admixtures for concrete
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 6/23
4 CONCRETE WORK
The concrete can be designed in grades denot
ing characteristic compressive strength or by
volumetric proportion of the constituents. The
concrete by volumetric proportion or nominal
mix concrete of the constituents is specified in
this Chapter
4.1 MATERIAL
4.1.1. Water, cement, lime, fine aggregate or
sand, surkhi, cinder and fly ash shall be as
specified in mortar chapter.
4.1.2 Coarse Aggregate
4.1.2.1 General: Aggregate most of which is
retained on 4.75mm IS Sieve and contains only
as much fine material as is permitted in IS 383
1970 for various sizes and grading is known as
coarse aggregate. Coarse aggregate shall be
specified as stone aggregate, gravel or brick
aggregate and it shall be obtained from ap
proved/authorised sources.
(a) Stone Aggregate : It shall consist of
naturally occuring (uncrushed, crushed
or broken) stones. It shall be hard, strong,
dense, durable and clean. It shall be free
from veins, adherent coatings, injurious
amounts of disintegrted pieces, alkali,
vegetable matter and other deletrious
susbstances. It shall be roughly cubical in
shape. Flaky and elongated pieces shall
be avoided. It shall conform to IS:383
1970 unless otherwise specified.
(b) Gravel: It shall consist of naturally
occuring (uncrushed, crushed or broken)
river bed shingle or pit gravel, It shall be
sound, hard and clean. It shall be free
from flat particles of shale or similar
laminated material, powdered clay, silt,
loam, adherent coatings ,alkali, vegetable,
matter mId other deletrious substances.
Pit gravel shall be washed ~f it contains
soil materials adhering to it. These shall
conform to IS:383-l970 unless other
wise specified.
(c) Brick Aggregate: Brick aggregate shall
be obtained by breaking well burnt or
overbumt dense brickslbrick bats. They
shall be homogeneous in texture, roughly
cubical in shape and clean. They shall be .'
free from unbumt clay particles. Soluble
salt, silt, adherent coating of soil, veg
etable matter and other deleterious
susbstances. Such aggregate should hot
contain more thaIl one percent of sulphates
and should not absorb more than 10 of
their own mass of water, when used in
cement concrete and 20 when used in
lime concrete. It shall conform to IS 306
1986 unless otherwise specified .
. (d) Light weight aggregates such as sintered
fly ash aggregate may also be used pro
vided the engineer in-charge is satisfied
with the data on the proportion of con
crete made with them.
4.1.2.2 Deleterious Material: Coarse aggre
gate shall not contain any deleterious material,
such as pyrites, coal, lignite, mica, shale or
similar laminated material, clay, alkali, soft
fragments, sea shells and organic impurities in
such quantity as to affect the strength or dura
bility of the concrete. Coarse aggregate to be
used for reinforced cement concrete shall not
contain any material liable to attack the steel
reinforcement. Aggregates which are chemi
cally reactive with alkales of cement shall not
be used. The maximum quantity of deleterious
material shall not be more than five percent of
the weight of coarse aggregate when deter
mined in accordance with IS:2386-l963 Pt. II.
4.1.2.3 Size and Grading
(i) Stone aggregate and gravel : It shall be
either graded or single sized as specified.
Nominal size and grading shall be as
under:-
(a) Nominal sizes of graded stone ag
gregate or gravel shall be 40, 20, 16,
or l2.5mm as specified. For any
one of the nominal sizes, the pro
portion of other sizes as determined
by the method prescribed in Appen
dix 'A' on page 59. shall be in
accordance with Table 1.
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 7/23
TABLE
1
E AGGREGATE OR GRAVEL
Percentage passing by weight) for nominal size of
0mm0mm6mm2.5 mm005 to 1000030 to 705 to 1000000
-
90 to 100
-
90 to 100
10 to 355 to 550 to 700 to 85to 5
- to 10
to 10to 16
b) Nominal sizes of single sized stone
aggregate or gravel shall be 63,40,
20,16,12.5 or lOmm }sspecified.
For anyone ofthe nominal size, the
TABLE 2
proportion of other sizes as deter
mined by the method prescribed in
Appendix A on page 59 shall be in
accordance with Table 2.
SINGLE SIZED UNGRADED) STONE AGGEGA TE OR GRAVEL
IS Sieve
Designation
Precentage passing by weight) for nominal size of
63mm 40 mm 20 mm 16 mm
12.5 mm 10mm
75mm
63mm
37.5mm
19mm
16mm
11.2mm
9.5mm
4.75mm
2.36mm
1
- 85-100
- 0-30
5
100
85-100
2
5
100
85-100
2
0-5
100
-85-100
0-30
0-5
100
85-100
0-45
0-10
100
85-100
2
5
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 8/23
c) When stone aggregate or gravel
brought to site is single sized
ungraded), it shall be mixed with
single sizes aggreg:lte of different
sizes in the proportion to be deter
mined by field tests to obtain graded
aggregate of specified nominal size.
For the required nominal size, the
proportion of other sizes in mixed
aggregate as determined by method
prescribed in Appendix A on page
59 shall be in accordance with Table
1. Recommended proportions by
volume for mixing of different sizes
of single size ungraded) aggregate
to obtain the required nominal size
of graded aggregate are given in
Table 3.
TABLE 3
SINGLE SIZED UNGRADED) STONE AGGREGATE OR GRAVEL
Cement
concrete
1:6:12
1:6:12
1:5:10
1:5:10
1:4:8
1:4:8
]:3:6
1:3:6
1:3:6
1:2:4
1:2:4
1:2:4
1:1 1/2:3
Nominal size
pints of single size aggregate
of graded
of size
aggrggate
required
50mm0mm
0mm
33
71/2
-
21/2
-
1/2
21/2
6
2
-
2
41/2
-
1
1/2
-
1/2
11 2
-
41/21/2
-
3
20
-
2
12.5mm lOmm
3
Note:
i) The proportions indicated in table 3 above
are by volume when considered neces
sary, these proportions may be varied
marginally by Engineer-in-charge after
making sieve analysis of aggregate
brought to site for obtaining required
graded aggregate. No adjustment<; in rate
shall be made for any variation in the
proportions so ordered by the Engineer
in-charge. If single size coarse aggregate
are not premixed at site to obtain the
graded coarse aggregate required for the
the mix, the volume of single size aggre
gates required for the mix shall be suit
ably increased to account for reduction in
total volume at the site of mixing
ii) Brick Aggregate: Nominal size of brick
aggregate shall be 40 mm and its grading
shall be as specified in Table 4 when
tested for sieve analysis by the method
prescribrd in Appendix A on page 59.
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 9/23
TABLE 4
Brick Aggregate
IS Sieve Designation precemage passing
byweight)
75
mm
100
gross measurements of the stacks ·is to be made
in respect of aggregates of nominal size below
40mm.
4.1.3 Admixtures: When required, admix
tures of approved quality shall be mixed with
concrete, as specified. The admixtures shall
confonn to IS 9103-1979.
37.5
mm
95 - 100
4
Cement Concrete.
19.0 mm 45 - 100
4.75 mm 0 - 5
Note: Coarse aggregate for cement con-
crete shall generally conform to
para 4.2.1 oOS 456-1978 and fine
aggregate shall conf01ill to IS:383
1970
4.1.2.4 Stacking: Aggregate shall be stacked
on a hard, dry and level patch of ground. When
stack piling, the aggregate shall not form pyra
mids resulting in segregation of different sized
materials. It shall be stacked separately accord
ing to nominal size of coarse aggregates. Stack
ing shall be done in regular stacks, of height not
exceeding 100 em.
4.1.2.5 Testj'ttg : Coarse aggregate shall be
tested for the followings (as per IS : 2386
1963) :
(a) . Determination of particle size and shape
(Appendix' A' on page 59)
(b) Estimation of organic impurities (as per
IS:2386-1963 Part II)
(c) Surface moisture (Appendix 'B' on page
60)
(d) Determination of 10 fine value (Ap-
pendix
c
on page 60)
4.1.2.6 Measurements: The aggregates shall
be measured in stacks and paid for after making
a deduction of? .5 of the gross measurements
of stacks in respect of aggregates of nominal
size 40 mm and above. No deduction from the
4.2.0 This shall be prepared by mixing graded
stone or bIick aggregate of nominal size as
specified with tIne aggregate and cement in
specified proportions with required quantity of
water.
The grading and quality of aggregates shall be
such as to give rninimum compressive strength
of 140 kg/cm2 and 210 kg cm2 at 7 days and 28
days respectively in case of mix 1:2:4. (One
cement: Two Coarse sand: Four stone aggre
gate)
One sample consisting of 6 cubes 15x15x15
em shall be taken for every 15 cubic metre or
part there of of cement concrete 1:2:4. The cube
tests shall not be carried out in case the quantity
.of cement concrete placed on any day is less
-than 15 cubic metre unless otherwise speci
fied. For other details, refer Chapter on R.C.C
work.
4.2.1 Proportioning: It shall be done by
volume. Boxes of suitable size shall be used for
measuring sand and aggregate. The internal
dimentions of the boxes shall be generally
35x25x40 cm deep or as otherwise approved·
by the Engineer-in-charge. The unit of mea
surement of cement shall be a bag of 50 kg. and
this shall be taken as 0.035 cubic metre. While
./
measuring the aggregate, shaking, ramming or
heaping shall not be done. The proportioning·
of sand shall be on the pasis of it~ dry volume
and in case of damp sand, allowances for
bulkage shall be made as given in the chapter
for mortar.
4.2.2 Preparation: This shall be prepared
by mixing coarse aggregate, fine aggregate and
cement in specified proportions with required
quantity of water. ,Nominal size and quality of
aggregate shall be as specified.
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 10/23
Except where brick aggregate is used in cement
concrete, minimum compressive strength on
works test for different concrete mixes sha11be
.as specified for various grades prepared by
volume basis, in Table 5 below. The work test
s ll be carried out for every 15 cum of a day s
concrc6ng unless otherwise specified.
Table 5
in Compressive strength
5cm cube in
kg/cm2
8 days
101575654010
4.2.2.2 Power Loader : Mixer will be fitted
wiL~ a power loader complying with the fol
lowing requirements.
a) The hopper sha11be of adequate capacity
to receive and discharge the maximum
nominal batch
of
unmixed materials with
oui: spillage under normal operating con
ditions on a level site.
Note: In such a case the volume of the
maximum nominal batch of mixed
material is 50 greater than the
nominal mixed batch capacity
b) The minimum inside wid~h Qfthe feeding
edge of the hopper shall be as specified
below in table 6.
Table 6
c) The design of the loader shall be such that
it allows the loading hopper to be el
evated to such a height that the centre line
of the chute plate of the hopper when in
discharge position, is at an angle of not
less than 50° to the horizontal. A me
chanical device to aid discharge of the
contents as quickly as possible from the
hopper to the drum ma y also be provided.
Even when a mechanical device is pro-
4.2.2.1 Mixing: Concrete shall be mixed in
mechanical batch type concrete mixers con
forming to IS 1791-1985 having two blades
and fitted with power loader (lifting hopper
type). Half bag mixers and mixers without
lifting hoppers shall not be used for mixing
concrete. In exceptional circumstances, such
as mechanical breakdown of mixer, work in
remote areas or power breakdown and when
the quantity· ef concrete work is very small,
hand mixing :may be done with the specific
prior permission of the Engineer-in-Charge in
writing subject to adding 10 extra cement.
When hand mixing is permitted, it shall be
carried out on a water tight platform and care
shall be taken to ensure that mixing is contin
ued until the concrete is uniform in colour
.
consistency. Before mixing the brick aggre
gate shall be well soaked with water for a
minimum period of two hours and stone aggre
gate or gravel shall be washed with water to
remove, dirt, dusCand 6therforei~n mateIials.
For guidance. the mixing time maybe 1-1/2 to
2 minutes, for hydrophobic cement it may be
taken as 2-1/2 to 3 minutes.
51
Nominal size
of mixer
(1 ,
NT
or
R), litre
140
200
280
375
500
1000
T=tilting
NT=nontilting
R=Reverse
Minimum inside
width of hopper
feeding edge in
1.0
1.1
1.2
1.4
1.5
2.0
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 11/23
vided, it is recommended that the angle of
centre line of the chute plate of the hopper
when in discharge position, should be as
larger as parcticable, preferably not less
than 40° to horizontal.
following limits :
Cement
Fine aggregate
8
d) Whe,n the means of raising and lowering
the loading hopper includes flexible wire
ropes winding on to a drum or drums, the
method of fast~ning the wire to rope to
the drums shall be such as to avoid, as far
as possible any tendency to cut the strands
of, the ropes and the fastening should
preferably be positioned clear of the bar
rel of the drum for example, outside the
drums flange. When the loading hopper
is lowered to its normal loading position,
there should be at least one and a half
drums of rope on the drum.
e) Gutch brake and hydraulic control lever
shall be designed so as to prevent dis
placement by liberation or by accidental
contact with any person.
,f) The clutch and brake cotrol arrangements
shall also be so designed that the operator
can control the falling speed of the loader.
g) Safety device shall be provided to secure
the hopper in raised position when not in
use.
4.2.2.3 Mixing efficiency: The mixer shall be
tested under normal working conditions in
accordance with the method specified in IS
464:3 - 1968 with a view to check its ability to
mix the ingredients to obtain concrete having
uniformity within the prescribed limits. The
uniformity of mixed concrete shall be evalu
ated by finding the precentage variation in
quantity (mass in water) of cement, fine aggre~
gate and coarse aggregate in a freshly mixed
batch of concrete:
The precentage variation between the quanti
ties of cement, fine aggregate and coarse aggre
gates (as found by weighing in water) in the
two halves of a batch and average of the two/
halves of the batch shall not be more tha_uihe
Coarse aggregate
5
4.2.2.4 Machine Mixing : The mixer drum
shall be flushed dean with water. Measured
quantity of coarse aggregate shaH be placed
first in the hopper. This shall be followed with
measured quantity of fine aggregate and then
cement. In case fine aggregate is damp, half the
required quantity of coarese aggregate shall be
placed in the hopper, followed by fine aggre
gate and cement. Finally the balance quantity
of coarse aggregate shall be fed in the hopper,
then the dry materials are slipped into the
drum by raising the hopper. The dry material
shall be mixed for atleast four turns of the
drum. While the drum is rotating, water shall
be added graduaHy to achieve the water cement
ratio as specified or as required by the Engi
neer-in-charge. After adding water, the mixing
shall be continued until concrete of uniform
colour, uniformly distributed material and
conistency is obtained. Mixing shall be done
for atleast two minutes after adding water. If
there is segregation after unloading from the
mixer, the concrete should be remixed.
The drum shall be emptied before recharging.
When the mixer is closed down for the day or
at any time exceeding 20 minutes, the drum
shall be flushed cleaned with water.
4.2.2.5 nd Mixing: When hand mixing
has been specifically permitted in exceptional
circumstances by the Engineer-in-Charge. in,
writing, subject to adding 10 extra cement, it
,shall be carried out on a smooth, clean and
water tight platform of suitable size. Measured
quantity of sand shal1.be spread evenly on the
platform and the cement shall be dumped on
the sand and 9Jstributed~evenely. Sand and
cem~ELshall15e mixed intimately with spade
/ _,until the mixture is of even colour throughtout.
Measured quantity of coarse aggregate shall be
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 12/23
spread on top of cement _sand mixture and
mixing done by shovelling and turning till the
coarse aggregate gets evenly distributed in the
cement sand mixture. Three quarters of the
total quantity of water required shall be added
in a hollow made in the middle of the mixed
pile and the material is turned towards the
middle of pile with spade. The whole mixture
is turned slowly over and again and the remain
ing quantity of water is added gradually. The
mixing shall be continued until concrete of
uniform colour and consistency is obtained.
The mixing platform shall be washed and
cleaned at the end of the day.
4.2.3 Workability: The quantity ofl water
to be used for each mix shall be such that the
concrete is of. adequate workability for the
placing condition~ of the concrete arid can
properly be compacted with the means ~peci
fied.Generally the quantity of water to be used
for each mix of 50 kgs. cement shall not be
more than 34litres for 1 :3:6 mix 30 litres for
1:2:4 mix 30 litres for 1:1-1/2:3 mix and 25
litres for 1:1:2 mix. In case of vibrated con
crete the quantity of water may be suitably
reduced to avoid segregation. The quantity of
water shall be regulated by carrying out regular
slump tests as described in Appendix D on
page 62. The slump and workability for differ
ent kind of works shall be as per ta ble 7 ~elow.
Placing conditions.
TABLE NO.7
Degree of workability
Value of Workability
Concreting of shallow
sections with vibration
Very low.
0.75-0.80
Compacting
factor.
~J
Concreting of lightly
reinforced section
with vibration.
Concreting of lightly
reinforced section without
vibration or heavily
reinforced sections with
. vibration.
Concreting of heavily
reinforced sections.
without vibration.
Low
Medium
High
Slump up to. 25mm
J
10-5 seconds vee
bee time
or 0.8-0.85
compacting factor.
25-75mm
slump for 20mm
aggregate. ~~
75-125 mm slump
for 20mm
aggregate .
. Note:- Whe~considered necessary the workability of the concrete may also be ascertained by
..---ompacting factortest and vee- bee. censistometer method as specified in IS: 1199~1959. For
~~/ suggested ranges of value of workability of concrete by the above two methods reference
- may be made to IS:456-1978. i
53
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 13/23
4.2.4 Transportation: Concrete shall be
transported from the mixer to the· place of
laying as rapid I
as possible by methods which
will prevent the segregation or loss of any of
the ingredients and maintaining the required
workability.
4.2.5 Placing: The concrete shall be depos
ited as nearly as practicable in its final position
to aviod rehandling. It shall be laid gently (not
thrown) and shall be thoroughly vibrated and
compacted before setting commences and
should not be subsequently disturbed. Method
of placing shall be such as to preclude segrega
tion. Care shall be taken to avoid displacement
of reinforcement or movement of form work
and damage due to rams.
4.2.6 Compaction : Concrete shall be
throughly compacted and fully worked around
embedded fixtures and into comers of the fonn
work. Compaction shaH be done by mechani
cal vibrator of appropriate type till a dense·
concrete is obtained. The mechanical vibrators
shall conform to IS 2505-1980 specifications
for concrete vibrators (immersion type). To
prevent seggregation, over vib~ation shall be
avoided. The use of mechanical vibrator may
be relaxed by the Engineer-in-charge at his
discretion for certain items and permit hand
compaction.
Hand compaction shall be done with the help of
tamping rods. Compaction shall be completed
before the initial setting starts. For the items·
where. mechanical vibrators are not to be used,
the contractor shall take permission of the
Engineer-in-Charge in writing before the start
of the work. After compaction the top surface
shall be finished even and smooth with wooden
trowel before the concrete begins to set.
4.2.7 Construction Joints: Concreting shall
be carried out continuously upto construction
joints. The position and arrangement of con
struction joints shall be as shown in the struc
tural drawings or as directed by the Engineer
in-Charge. Number of such joints shall be kept
minimum. Joints shall be kept as straight as
possible.
54
4.2.7.1 When the work has to be resumed on a
surface which has hardned. such surface shall
be roughend. It shaH then be swept clean and
throughly wetted. For vertical joints, neat ce
ment slurry, of workable consistency by using
2 kgs. of cement per sqm shall be applied on the
surface before it is dry.
For horizontal joints, the surface shall be cov
ered with a layer of mortar about 1O-15mm
thick composed of cement and sand in the same
ratio as the cement and sand in concrete mix.
This layer of cement slurry of mortar shall be
freshly mixed and applied immediately before
placing of the concrete.
4.2.7.2 Where the COi1cretehas not fully hard
ened, alliaitance shall be removed by scrub
bing the wet surface with wire orbristle brushes,
care being taken to avoid dislodgement of
particles of coarse aggregate. The surface shall
be throughly wettcd and all free water re
moved. The surface shall then be coated with
neat cement slurry @ 2 kgs of cement per sqm.
On t.hissurface, a layer of concrete not exceed
ing 150 mm in thickness shall first be placed
and shall be well rammed against comers and
close spots; work, thereaftei, shall proceed in
the normal way.
4.2.8 Concreting under special conditions
4.2.8.1 Work in extreme weather conditions
During hot and cold weather, the concreting
shall be done as per the procedure set out in
IS:7861 (Part-I) - 1975 and IS:786 1(Part II)
1981 respectively. Concreting shall not be
done when the temperature falls below 4.5°C.
In cold weather, the concrete placed shall be
protected against frost. During hot weather, it
shall be ensured that the temperature of wet
concrete does not exceed 38° C.
4.2.8.2 Under water concreting
Concrete shall not be deposited under water if
it is practicable to de-water the area and place
concrete in the regular manner. The concrete
shall contain at least 10 more cement than
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 14/23
that required for the same mix placed in dry
conditions, the quantity of extra cement vary
ing with conditions of placing with prior writ
ten permission of the engineer-in-charge. Such
extra cement will be paid extra. The volume of
coarse aggregate shall not c;;
l~SS
than 1-1/2
times nor more than twice the fine aggregate
and slump not less than 100mm nor more than
18Omm. Where found necessary to deposit any
concrete under water; the method, equipment,
materials and mix shall first be got approved by
the Enginer-in-Charge. Concrete shall be de
posited continuously until
it
is brought to re
quired height. While depositing, the top sur
face shall be kept as nearly level as possible
and the formation of heaps shaH be avoided.
The concrete shall be deposited under water by
one of the approved methods such as tremie
method, drop bottom bucket, bags, grouting
etc. as per details given in IS 456-1978. Ifit is
necessary to raise the water after placing the
concrete, the level shall be brought up slowly
\vithoutcreating any waves or commotion tend
ing to wash away cement or to distrub the fresh
concrete in any way. -
4.2.9. Curing: When the concrete begins to
harden i.e. two to tl1f.t~eours after compaction,
the exposed surfaces shall be kept damp with
moist guny bags, sand or any other material
approved by the Enginner-in-Charge. 24 hours
after compaction, the exposed surface shall be
kept continuously in damp or wet conditions
by ponding or by covering wit.l], a layer of
sacking,canvass, hessian or similar absorbent
materials and kept constantly wet for atleast7
days where ordinary portland cement is used
and 10days, where portland pozzolona cement
is used from the date of placing of concrete. For
concrete work with other types of cement,
curing period shall be as dirceted by the Engi
neer-in-Charge.
Approved curing compounds may be used in
lieu of moist curing with the permission of the
Engineer-in-Charge. Such compounds shall be
applied to all exposed surfaces of the concrete
as soon as possible after the concrete has set.
4 2 9
Fresh y laid concrete shall be protected
from rain by suitable covering.
55
4.2.9.2 Over the foundatioljl concrete, the ma
sonry work may
be
started after 48 hours ofits
compaction but the curing of exposed surfaces
of cement concrete shall be continued along
with the masonry work for atleast 7 days. And .
where cement concrete is used as base concrete
for flooring, the flooring may be commenced
before the cUling period of base concrete is
over but the curing of base concrete shall be
continued along with top layer of flooring for
a minimum period of 7 days.
4.2.10 Testing of concrete will be done as
described in chapter ofR.C.C.
4.2.11 Form work : Form work shall be as
specified in R.C.C chapter and shall be paid for
separately unless otherwise specified.
4.2.12 Finishes: Plastering and special fin
ishes other than those, obtained through form
work shall be specified and paid for separately
unless otherwise specified.
4.2.13 Measurements:
4.2.13.1 Dimensions of length, breadth
thickness shall be measured correct to nearest
cm. except for the thickness of slab
partition
which shall be measured to nearest 5 mm.
Areas shall be worked out to nearest 0.01
square metre and the cubic contents of cons6li
dated concrete shall be worked out to nearest
0.001 cubic metres. Any work done in excess
over the specified dimension or sections shown
in the drawing or as required by Engineer-in
Charge be ignored.
4.2.13.2 Concrete work executed in the follow
ing conditions shall be measured separately
a. Work in or under water
b. Work in liquid mud
c. Work in or under foul positions
4.2.133
Cast-m-situ conc,rete and or precast
cOIlcrete work Shall be measured in stages
described in the item of work, such as;
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 15/23
c. Between two specified floor levels
b. Openings upto 0.1 sq. metre
(1000 sq.cm)
4.2.13.4 No deduction shall be made for the
follpwing
e. Between two specified heights or
depths with reference toplinth level/
defined datum level.
4.2.13.6 Cast-in-situ concret shall be classified
and measured as follows :
a) Foundation, footings, bases for columns
b) Walls (any thickness) including attached
pilasters, buttresses, plinth and string
cours~s, fillets etc.
Shelves
Slabs
c)
d)
e)
4.2.13.5 Cast-in-situ and precast concrete work
shall be measured separately.
Chajjas including portions bearing on the
wall
t) Lintels, beams and bressummers
g) Columns, piers abutments, pillars, post
and struts
h) Stair case including stringer beams but
excluding landings.
i) Balustrades, newels and sailhg
j) Spiral stairase (including landings)
k) Arches
1) Domes, vaults
m) Shell roof, arch ribs and folded plates
n) Chimneys and shaft.
0) Breast walls, retaining, walls, return w~lls
p) Cqncrete fIlling to precast components
q) Kerbs, steps and the like
r) String or lacing courses, parapets, copings,
bed block, anchor blocks, plain window
sills and the like
s) Cornices and moulded windows sills.
t) Louvers, fins, facia.
Small voids such as shaded por
tions in Figure below when these do
not exceed 40 sq cm each in cross
section.
Volume occupied by pipes, con-,
duits, sheathing etc. not exceeding
100 sq em each in cross sectional
areas.
a. Ends of dissimilar materials for ex
ample beams, posts, girders,'fafters,
purlins trusses corbels and steps
upto 500sq cm in cross sections.
t
'a.
At or near the ground level
f b. Upto specified floor level
d. Up~o specified height above or
depth below plinth 'level/defined
datum level
.j C.
:1
•
I d.
~
\.,
Note: In calculating area of opening, the
thickness of any separate lintel or sill shall be
included in the height. Nothing extra shall be
payable for forming such openings or voids.
L
~~
[- J1
I
11
I
+-L
1--- L-+
I
AREA OF
FI6
Te
G
SHALL U.
==
Lx E3
C~
Jf
REA Of
fIe
H 52 J
SHALL BE-:zL;><[AVfRJ6E. Cf
-f--L --+-L-+
AHD FY]
F
~[~ t;
[-=:1~
- -
-+
- . +
- L --+
-- L -+
J
.....••
I
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 16/23
4.3 LIME CONCRETE
Class B - Semi hydraulic lime used for lime
concrete.
Class A Eminently hydraulic lime. used
r
structural purposes.
4.2.14 Rate: The rate is inclusive of the cost
of labour and materials involved in all the
operations described above.
4.3.2.1 Machine Mixing: The mixer shall be
flushed clean with water. Mixing shall be done
by pouring measured quantity of coarse aggre
gate and wet ground mortar for one batch in the
drum of the mixer, while it is revolving. The
quantity of materials loaded in the drum shall
not exceed the rated capacity of the mixer. The
water shall be added gradually upto the re
quired quantity and the wet mixing of batch
shall be continued for at least two minutes in
the drum till concrete of uniform colour uni
formly distributed materials and consistency is
obtained. The consistency of the.concrete shall
be such that the mortar does not tend to separate
from the coarse aggregate. If there is segrega
tion after unloading from the mixer the con
crete should be removed. The entire concrete of
batch shall be discharged before the materials
for the new batch are poured into .the drum.
Before suspending the work, the mixer shall be
cleaned by revolving the drum with plenty of
water each time.
100 parts o.l4.Pmm nomimil size graded stone
aggregate, gravel or brick aggregate as speci
fied and 40 parts oflime mortar of the specified
mix.
4.3.2 Mixing: Concrete shall be mixed in a
mechanical mixer. Inexceptional circumstances
specified in 4.2.2.1 hand mixing may be done
with the specific permission of the Engineer
in-Charge in writing. Before mAing, briCKS
aggregate shall be well soaked with water for a
minimum period of 2 hours and stone aggre
gate or gravel shall be washed with water to
remove dirt, dust or any other foreign materi
als.
4.3.2.2 Hand Mixing: When hand mixing is
specifically permitted by Engineer-in-Charge,
it shall be done on a clean and water tight
masonry platform of sufficient size t<;>rovide
ample mixing space. The specified wet lime
mortar shall be laid on the top of the aggregate
and turning shall be done over and again with
addition of necesary quantity of water till a
uniform mix of required consistency is ob
tained. The consistency of the concrete shall be
such that the mortar shall not tend to separate
from the coarse·aggregate.
Method of measurement
In cubic meters
In cubic meters
In square metres stating
the thickness or in cubic
meters.
In square metres stating
the thickness or in cubic
metres.
In square metres stating
the partition s thickness
In square meters stating
the thickness
f. Light weight
Partitions
e. Hollow block work
Classifications
4.3.1 PROPORTIONING:Theproportions
of aggregate to lime mortar shall be done by
volume. Generally lime is prepared by mixing
4.3.0 This shall be prepared by mixing coarse
aggregate and lime mortar in the specified
proportions with required quantity of water.
Lime shall conform to IS 712 - 1984 shall be
classified as below.
b. String or lacing
courses, copings;
bed plats, plain
windows sills,
shelves, louvers,
steps etc.
c. Kerbs, edgings etc.
d. Solid block work
a. Wall panels
4.2.13.7 Precast cement concrete solid articles
shall be measured separately and shall include
use of moulds, finishing the top surfaces even
and smooth with wooden trowel, before setting
in position in cement mortar 1:2 (1 cement :2
coarse sand). Plain and moulded work shall be
measured separately and the work shall be
classified and measured as under.
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 17/23
Table S
FL Y ASH CONCERETE MIXES
portland cement and llyash in specified propor
tions with required quantity of water. The
recommended cmnposition of cement fly ash
concrete are as under:
Flyash
2 5
I 28 Kg/cm2
Sand
:~oo
J
tone Aggregate
--.
Le,-ill
Concrete
1:4:8)
Cement
1.0
ordinary Portland)
Flyash
2.0
7 kg/cm2
Sand
3 5
Stone aggregate
9
J
Compressive Strength
at St;ven days.
Cement 1.0
Ordinary Port land)
Lean concrete 1:5:10)
Composition Dry volume)
4.3.4 Curing: After the concrete has begun
to harden i.e. about
4
hours after its placing
and compaction, .thc curing shall be done by
keeping dIe concrete damp with moist gunny
bags, sand, or any other method approved by
the Engineer-in-Charge for a minimum period
of? days. Till then, masonryand Hooring work
over the foundation or base concrete shall not
be started.
4.3.5: Measurements:
4.3.3 Placing and Compaction: Concrete
shall be laid anduot. thrown) in layers while it
is quite fresh. Each layer shall be throughly
rammed and consolidated before the succeed
ing layer is placed. Consolidated thickness of
each layer shall not exceed 15 em. Joints where
necesary shall be staggered in different layers
unless otherwise specified. Ramming shall be
done by heavy iron rammers of 4.5 kg to 5.5 kg.
The area of each rammer shall not be more than
300 sq. em. Ramming shall be continued tin a
skin of mortar covers the surface completely.
Concrete laid on a particular day shall be
consolidated throughly on the same day before
the work is stopped. Ramming on the follow
ing day shall not be done. Freshly laid concrete
shall be protected from rains by suitable cover-
·ings.
4.3.5.1: Length, breadth and depth orthickness
shall be measured correct to a em and the
consolidated cubic contents of the concrete
shall be calculated nct to the nearest 0.01 cubic
metre. Concrete laid in excess of the dimen
sions shown in the drawings shall not be mea
sured.
Note: No flyash is to be added to
Puzzolona Portla~d cement in any case which
itself contains flyash
4.4.1: Proportioning shall be as specified in
4.2.1
4.3.5~2: Deductions shall be as specified in
4.2.13.4
4.3.6: Rate: The rate shall include the cost of
materials and labour involved in all operation
described above.
4 4 CEMENT-FLY ASH CONCRETE
4.4.2: Mixing shall be as specified in 4.2.2
except that the flyash shall be placed in the
hopper before cement in case of machine mix
ing.
4.4.3: Pladng and Gompaction shall be as
specified in 4.2.5
4.2.6.
4.4.4: Curing shall be as specified in\4 ..2.9.
4.4.0: Fly Ash concrete shall be prepared by
mixing graded coarse aggregate of nominal
size as specified with fine aggregate, ordinary
4.45:
Fonn work shall be as specified in
4.2.11.
58
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 18/23
TABLE 9
APPENDIX A
lause 4.1.2.3 4.1.2.5
Maximum weight for
I.S. Sieve 45 em dia 30 em dia
sieve sieve
kg
kg
10
4.5
8
3.5
6
2.5
4
2
3
1.5
2
l.{i
1.5
0.75
1.0
0.50
0.30
45mm
37.5mm
31.5mm or 22.1mm
19mm
16mm or 11.2mm
9.5mm
5.6mm
4.75mm
3.35m
In order that the sieves shall not be overloaded,
care must be taken to ensure that the maximum
sieve loads shown in table below are not ex
ceeded at the completion of sieving.
The apparatus, sample size and test procedure
shall be same as specified in sub-head MOR
TARS
DETERMINA TION OF PARTICLE
SIZE
4.5.6 Rate: The rate is inclusive of the cost
of materials and labour involved in all the
operations described above except for the ap
plication of a coat of hot bitumen and addition
of water proofing materials which shall be paid
forseparately, unless otherwise specified .
specifications stating the quantity of water
proofing material in litres or kg per 50 kg of
cement and will be paid for separately;
4.5.5. Measurements: The length and
breadth shall be measured correct to a em and
its area shall be calculated in square metres
correct to two places of decimal. The depth
shall not be less than the specified thickness at
any section.
4A7:
Rate: Rate shall include the cost of
materials and labour involved in all the opera
tions described above.
4.4.6: .Measurements shall be as specified in
4.2.13.
4.5 DAMP PROOF COURSE
4.5.1: Cement Concrete layer: This shall
consist of cementconcrete of specified propor
tions and thickness. The surface of brick or
stone masonry work shall be levelled and pre-
,pared before laying the cement concrete. Edge
of damp poof course shall be straight, even and
vertical. ~ide shuttering shall consist of steel
forms and shall be strong and properly fixed so
. that it does not get di~turbed during compac
tion and the mortar 40es not leak throgh. The
concrete mix shall be of workable consistency
and shall be tamped throughly to make a dense
mass. When the sides are removed, the surface
should come out smooth without honey-comb
ing. Continuity shall be maintained while lay~
ing the cement concrete layer and laying shall
be terminated only at the predetermined loca
tion where damp proof course is to be discon
tinued. There shall be no construction joint in
the Damp Proof Course.
4.5.2 Curing: Damp proof course shall be
cured for at least seven days, after whichit shall
be allowed to dry.
4.5.3
Application of Hot Bitumen: Where
so directed, hot biutmen in specifed quantity
shall be applied over the dried up surface of
cement concrete, properly cleaned with brushes
and finally with a piece of cloth .soaked in
kerosene oil. .Bitumen of penetration A 90 or
equivale~t where used shall be heated to a
temperature of
16 °
± SoC. The hot bitumen,
shall be applied uniformally. allover, so that no
blank spaces are left anywhere. It will be paid
for separately.
••.5.4 Water proofing ~aterials : Where
so specified, water proofing material of ap
proved qhality shall be added to the concrete
mixture in accordance with the m:mufacturer s
5~4/CPWD/ND/92
59
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 19/23
The sample weights taken_will thus nanniilly
require several aperatians on each sieve~ Each
sieve shauld be shaken separately over a Clean
-tray arreceiveruntil namare than a tiace passes,
but in any case for nat less than twO minutes.
Material shauld nat be forced through _the
apertures but hand placing is pennitted.
A
light
brush should be -used with fine sieves~ The
cumulative weight passing each sieve shauld
be clacuJated as a percentage afthe total sample
weight to the nearest whale number.
cantact with the aggregate shall be m.a
chined and case hardened ar atherwise
treated sa as to have a diamand VH)
pyramid hardness num ber af nat less than
-650 VH.
b) A staight metal tamping rod af circular
crass-section 16 mm in diameter and 45
to 60 cm lang, raunded at ane end.
c) A balance af capacity 3 kg, readable and
accurate to ane gram:
d) I.S Sieve af sizes 12.5, 10 and 2.36 mm
e) A campressian testing machine capable
af applying a laad af 50 tonnes and which
can be ape rated to give aunifann rate af
laading sa that the maximum
10
ad in any
test is reached in 10 minutes. This laad
may vary from 0.5 to 50 tannes.
f) Far measuring the sample, a cylindrical
metal measure af sufficent rigidity to
retain its fann under rough usage and af
the fallawing internal dimensians:
g) Means af measuring the reductian in the
distance between the plates afthe testing
machine to-the nearest ane millimetre
during the test far example, dial gauge).
Test Sample :- .Material fo r the test shall
cansists af aggregate passing a 12.5 mm I.S.
Sieve and retained an a 10 mmI.S. Sieve. The
aggregate shall be tested in a surface dry can
ditian. If dried by heating the periad af drying
shall nat exceed faur haurs, the temperature
shall be 100° tall ace and the aggregate shall
becaale~ to roam temperature befare testing.
The quantity af aggregate shall be such ~at the
dept~ afmaterial in the.cylinder, aftertamping
as described belaw, shall be 10 cm. _.
The weig~ta~ m,aterial camprising the test
saI11pleshall be de~enpined weight A) and the
same weight af sample shall be taken far the
. repeat test.
APPENDIX B
TEST FOR SURFACE MOISTURE
Clalise 4.1.2.5
Take a sample af wet aggregate and weigh it
A Then place it in a frying pan and gently
apply heat, meanwhile stirring with a glass rod
until the surface maisture disappears. This is
apparent when the aggregate lases its shining
wet appearance and becames dull, ar when it
just attains a free running canditian. The satu
rated surface-dry material is then weighed B).
Cantinue the heating there~fter until the mais~
ture is evaparated and weigh the dry sample
C). The surface maisture is then calculated as
fallaws:-
A B
Surface maisture ,,;lOOx -
C
It is expressed as a pyrcentge af dry aggregate.
APPENDIX C
DETERMINA TION OF TEN PERCENT
FINE VALUE
Clause 4.1.2.5.
Apparatus :- The apparatus far the standard
test shall cansist af the fallawing:
a) A 15 cm diameterapen-ended steel cylin
der~with plunger and base-plate, as shawn
ip Fig. an page NO . 61. The surfaces in
Diameter
Height
l1.5cm
18.0 cm
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 20/23
,NOTE::' .Abou , 6.5 kg~of natUral aggregate is
require~to provide the ~two'testsanJpl~s: --ess
of lig])tweight aggregate is' reqUired.
c~ , :
.
,
~ .-..
The measuring cylinder is filled ill three layers '
of approximately equal,depth: with aggre&ate
'passing a 12.5mm,tS~Sieve and refainedoriJO
mm I.S.Sieve. :Eachlayer is subje~ted to 25
strokes f:r:omthe tamping rod (16 mm dia and, :'
45 to 60 cm long) ropn<: edaq, one end, care,
being takenin case of we.ak m;uerials not to
break the partic1es.:The surface,of 1lle aggre
gate shall be carefully.1~v~~led and the plunger
inserted so that it rests h<;>rlzontallyon this
surface. 11/;
Test Ptocedur~ :- Theapparatus, with thet~st·
sample alld plunger in position; shall tpeI) 'be
placed ill the'compression'te~tingmachiiie:'
, ~,
. - .~-~ - ,
The load shall'be applied at a,umfoml rate so as
. ~ . ',' .* .
to cause a total pen~tration of the p iIDger in 10
minutes of' about; 15.qrnm for rounded or
partially~qunded aggregat~s (for example,~ex
panded shales
~9
slags ..ll.es~:figu~ts Il}aybe
varied accordJ-ng t9 he exte~t
t
therqunding
or honey combing.
>
After reaching the required tfiaximum peIJetra~
tion, the load shall be released and the whole of
- the material removed, from 'the cylinder and
sieved on a 2.36 mm I.S. Sieve. 'DIe fines
passing the sieve, shall be weighed, and this
weight expressedl as a precentage of the:'weight
of the test sample. 'Nqrmally, this percentage
will fall within the range 7.? to 12.5; butifiL
does not, a further test shag be made, at a load
adjusted appropriately, to bring th~ precentage
fines within the range of 7:5 to 12.5
A repeat test shall ,be made at the ,load thaL
gives as percentge fines within the range 7.5 to
12.5.
Cah;ulations:- Themeanp~[centage filles fro,m
the two tests at'thiscload shall be used In the
_.~
following form\lla .to' calculate. the load' re.t
quired
19
give 10 percentage fines.
.
,....
Load:required·for 10 percent filles
=
14·x X
Y+4
Where X=Load in tonnes and
Y=mean ~rcentage fines from two test at X
tomles load.
porting ofr,esults:- ~,~ load required, to
produce 10 percent fines shall be ~eported to
'the nearest whole number for loads of 10
tonnes <?rmore, the nearest 0...5 tonneJor loads
. ofless than 10 tonnes. The v'alue expressed to
the nearest 0.5 tonne shouldbe as follows:
i
(a) For'normal concrete, not less than 5
tonnes.
(b)' Forweating sufaces, noiles's°than 10
, tonnes.
(c) For granolithic concrete, not less than 15
tonnes.
-,
t2
••
o
~- ,--,,~ ~- ~ t , ,~.~: ~: ~ -, : ~
'. APPt>~ATyS'{F()R'bEfE~A
p
Of ~ ,
TENPERCENT FINE. v AdJE, .
61
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 21/23
PPEN IX
SLUMP TEST
Clause 4.2.3
Apparatus : Mould shall consists of a metal
frustum of cone having the following internal
dimensions :-
Bottom diameter 20 cm
Top diameter ..: : lOcm
Height 30cm
The mould shall be of a metal other than brass
,and aluminium, of at least 1.6 mIl} or 16 BO)
thickness. The top and bottom shall be open
and at right angles to the axis of the cone. The
mould shall have a smooth internal surface. It
shall be provided with suitable foot pieces and
handles to facilitate lifting it from the moulded
concrete test specimen in a vertical direction as
required by the test. A mould provided with a
suitable guide attachment may be used .
mping roishall be of steel or other suitable
material 16 mm in diameter 60 mm long and
rounded at one end.
Procedure:- The internal surface.ofthe mould
shall be throughly cleaned and free from super
fluous moisture and any set concrete before
commencing the test~The mould shall be placed
on a smooth horizontal, rigid ana non absor
bent surface viz. levelled metal plate. The
operator shall hold the mould firmlyin place
while it is being filled with test specimen of
concrete. The mould shall be filled in four
layers, each approximately one quarterofheight
of mould. Each layer shall be tamped with
twenty five strokes of the rounded end of the
tefiping rod. The strokes shall be distributed in
a uniform manner over the cross section of the
mould and for the second and subsequent lay
ers shall penetrate into the under-lying layer. ,
The bottom layer shall be tamped through out -
its depth. After the top layer has been rodded,
the concrete - shall be struck off level with
trowel or the tamping rod, so that the mould is
exactly fIlled. Any mortar which shallleatc out
between the mould and the base plate shall be
cleaned away. The mould shall be removed
from the concrete immediately after filling by
raising it slowly and carefully in a vertical
direction. The moulded concrete shall then be
-allowed to subside and the slump shall be
measured immediately by determining the dif
ference between the height of the mould and
that of the highest point of specimen.
-,
The aboye operations shall be carried out at a
place free from vibration or shock, and within
a period of two minutes after sampling.
Result:- The slump shall be recorded in terms
of millimetres of subsidence of the specimen
during the test Any slump specimen which
collapses or s~ears offlaterallygives incorrect
result. If this occurs, the test shall be repeated
with another sample.
The slump test shall not be used for very dry
mixes as the results obtained are not accurate.
62·
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 22/23
OT S
6
8/10/2019 Vol-II Concrete Work
http://slidepdf.com/reader/full/vol-ii-concrete-work 23/23
T E S