Schematic diagram of the insert Volcano W with water jacket in a open circuit Schematic diagram of the insert Volcano W with water jacket in a closed circuit 1. Expansion vessel with filling fittings 2. Circulation pump 3. Control Unit - regulator 4. Temperature sensor 5. Thermostatic valve 6. Thermostatic valve capillary 7. Cooler 8. Temperature valve (VTC300) 9. Acumulation tank - Buffer 10. Pressure valve (max. 2,5 bar) T- Thermometer M. Manometer 1. Expansion vessel with a float 2. Circulation pump 3. Control unit - regulator 4. Temperature sensor 5. Thermostatic valve 6. Thermostatic valve capillary 7. Cooler 8. Temperature valve (VTC300) 9. Heat exchanger T- Thermometer P1 P2 Volcano W Volcano W T 1 10 4 7 6 5 3 9 2 2 8 4 7 6 5 3 1 9 2 2 8 T Water supply Expansion pipe G-1 1/2 Overflow pipe diameter min 25mm Outflow from cooler Water supply G-1 G-1 Central heating supply Central heating supply return from central heating system Return to water complex G-1 G-1 Sewage system G-1 G-1 G-1 G-1 G-1 Water supply Sewage system Return to water complex central heating supply Return from central heating system solar central heating installation supply Hot water supply 1/2 T1 P1 P2 T1 P1 P2 M. P1 P2 T1 T1 Outflow from cooler

Upload: others

Post on 29-Jul-2020

13 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Volcano W - Hajduken.hajduk.eu/uploads/wklady/Schematic diagram of water...Schematic diagram of the insert Volcano W with water jacket in a open circuit Schematic diagram of the insert

Schematic diagram of the insert Volcano W with waterjacket in a open circuit

Schematic diagram of the insert Volcano Wwith water jacket in a closed circuit

1. Expansion vessel with filling fittings2. Circulation pump3. Control Unit - regulator4. Temperature sensor5. Thermostatic valve6. Thermostatic valve capillary7. Cooler8. Temperature valve (VTC300)9. Acumulation tank - Buffer10. Pressure valve (max. 2,5 bar)T- ThermometerM. Manometer

1. Expansion vessel with a float2. Circulation pump3. Control unit - regulator4. Temperature sensor5. Thermostatic valve6. Thermostatic valve capillary7. Cooler8. Temperature valve (VTC300)9. Heat exchangerT- Thermometer

P1

P2

Volcano W

Volcano W

T

1

10

4

7

6

5

3

9

22

8

4

7

6

5

3

1

9

228

T

Wate

r su

pply

Exp

ansi

on p

ipe

G-1 1/2

Ove

rflo

w p

ipe

dia

mete

r m

in 2

5m

m

Outflow from cooler

Water supply

G-1G-1

Centr

al h

eatin

g s

upply

Central heating supply

return from central heating system

Return to water complex

G-1 G-1

Sew

age s

yste

m

G-1G-1

G-1G-1

G-1

Water supply

Sewage system

Return to water complex

central heatingsupply

Return from central heating system

solar

central heating installation supply

Hot water supply1/2

T1 P1 P2

T1 P1 P2

M.

P1 P2

T1

T1

Outflo

w fro

m c

oole

r

Page 2: Volcano W - Hajduken.hajduk.eu/uploads/wklady/Schematic diagram of water...Schematic diagram of the insert Volcano W with water jacket in a open circuit Schematic diagram of the insert

Volcano WL/WLH

Volcano WL/WLH

2

5

7

64

T

1

8

9

3

Wate

r su

pply

Sew

age s

yste

m

Retu

rn to w

ate

r co

mple

x

Centr

al h

eatin

g s

upply

Central heating supply

Return from centralheating system

G-1 1/2G-1 G-1

G-1

2

P1 P2

T

4

5

6

10

7

1M.

9

3

822

Water supply

Sewage system

G-1 1/2G-1

G-1

G-1

Hot water supply

Centrlal heating installation supply

solar

Return from centralheating system

central heatingsupply

P1P2

Return to water complex

T1 P1 P2Outflow from cooler

T1

T1

Schematic diagram of the insert Volcano WL/WLHwith water jacket in an open circuit

Schematic diagram of the insert Volcano WL/WLH with water jacket in a closed circuit

1. Expansion vessel with a float2. Circulation pump3. Control unit - regulator4. Temperature sensor5. Thermostatic valve6. Thermostatic valve capillary7. Cooler8. Temperature valve(VTC300)9. Heat exchangerT - Thermometer

1. Expansion vessel with filling fittings2. Circulation pump3. Control Unit - regulator4. Temperature sensor5. Thermostatic valve6. Thermostatic valve capillary7. Cooler8. Temperatire valve (VTC300)9. Acumulation tank - buffer10. Pressure valve (max. 2,5 bar)T - ThermometerM.-Manometer

Exp

ansi

on p

ipe

T1 P1 P2

Page 3: Volcano W - Hajduken.hajduk.eu/uploads/wklady/Schematic diagram of water...Schematic diagram of the insert Volcano W with water jacket in a open circuit Schematic diagram of the insert

Volcano WP/WPH

Volcano WP/WPH

T1

2

5

7

64

T

1

8

9

3W

ate

r su

pply

Sew

age s

yste

m

Return to water complex

Centr

al h

eatin

g s

upply

Central heatingsupply

Return from central heating system

G-1 1/2G-1

G-1

2

P1 P2

T

4

5

6

10

7

1

M.

9

3

822

Water supply

Sewage system

G-1 1/2G-1

G-1

G-1

Hot water supply

central heating installation supply

solar

Return from central system

central heating supply

P1P2

Return to water complex

10

G-1

Outflow from cooler

Schematic diagram of the insert Volcano WP/WPHwith water jacket in an open circuit

Schematic diagram of the insert Volcano WP/WPHwith water jacket in a closed circuit

1. Expansion vessel with a float2. Circulation pump3. Control unit - regulator4. Temperature sensor5. Thermostatic valve6. Thermostatic valve capillary7. Cooler8. Temperature valve (VTC300)9. Heat exchangerT - Thermometer