volte call drop for training_0307

Upload: shaikh

Post on 13-Apr-2018

433 views

Category:

Documents


18 download

TRANSCRIPT

  • 7/26/2019 VoLTE Call Drop for Training_0307

    1/15

    CLOT Issue Analyzing

    (VoLTE Call Drop)

    7.Mar, 2015

    Joohyun,Kim

  • 7/26/2019 VoLTE Call Drop for Training_0307

    2/15

    Summary-Case Study-1/2/3

    Cluster_AP-TNDR-0236-C2(VoL)

    Key VoLTE Drop

    Call drop was caused by Mobile to Server test scenario(known issue) By server setting, every 15 minutes, UE could have call drop by no-RTP

    This is not KPI fail, but UE should have Byemessage

    If there are call drop for VoLTE call attach in VoL UE, this is call drop(Refer to Next Slide)

    Call Drop was caused by end by user

    This is not KPI fail

    Call Drop was caused by 500 Server internal error

    Server Internal Error 5xx responses are failure responses given when a server itself has

    erred

    AP-TDNR-0236-C2 Call drop summary

    1 SAMSUNG Electronics Co., Ltd. Confidential and Proprietary

  • 7/26/2019 VoLTE Call Drop for Training_0307

    3/15

    Cause of Failure(Code 500 error)

    For VoLTE Attach , Call drop happened by SIP Fail cause Code 500

    Code 500 : Server Internal Error 5xx responses are failure responses given when a server itself has erred

    UE didnt receive the 183 session progress

    Case Study-1(VoLTE Call Drop)

    500 Server Internal Error

  • 7/26/2019 VoLTE Call Drop for Training_0307

    4/15

    Call drop by serve call scenario

    Call drop was caused by Mobile to Server test scenario(known issue)

    By server setting, every 15minute, UE could have call drop by no-RTP

    This case is not KPI fail , but UE, UE should send the Byemessage

    Case Study-2(VoLTE Call Drop)

    500 Server Internal Error

    15 minutes period

  • 7/26/2019 VoLTE Call Drop for Training_0307

    5/15

    Call Drop was caused by end by user

    Call drop was caused by end By user

    This is not KPI fail about this case

    Case Study-3(VoLTE Call Drop)

  • 7/26/2019 VoLTE Call Drop for Training_0307

    6/15

    Summary_Case Study-4(Drop-Bye)

    CLUSTER TN-EROD-0037_VOL-ISSUE LOG(VoL)

    Why there are happened like Drop-Bye

    Call drop was caused by User disconnected call by screen or ear phone button. It is not KPI Fail

    Below is the event situation by tester

    1st : User disconnected call by screen or ear phone button

    2nd : User stopped Smart DM

    5 SAMSUNG Electronics Co., Ltd. Confidential and Proprietary

  • 7/26/2019 VoLTE Call Drop for Training_0307

    7/15

    Case Study-4(Drop-Bye)

    CLUSTER TN-EROD-0037_VOL-ISSUE LOG(VoL)

    Why there are happened like end by user

    Call drop was caused by end by user from user stopped smart DM. It is not KPI Fail

    Below is the event situation by tester

    1st : User stopped Smart DM

    2ND : Smart DM Automatically disconnected call

    6 SAMSUNG Electronics Co., Ltd. Confidential and Proprietary

    End By User

  • 7/26/2019 VoLTE Call Drop for Training_0307

    8/15

    Case Study-4(Drop-Bye)

    CLUSTER TN-EROD-0037_VOL-ISSUE LOG(VoL)

    During the test, there was some other call from other UE

    Event through, test UE is MO but MO UE received Rx-invite Msg form other UE It is strange situation

    7 SAMSUNG Electronics Co., Ltd. Confidential and Proprietary

  • 7/26/2019 VoLTE Call Drop for Training_0307

    9/15

    Summary_Case Study-5(BR-RNCH-0258)

    SAMSUNG Electronics Co., Ltd. Confidential and Proprietary

    After sending the 100 Trying Message, UE receive the SIP 200 OK lately

    During the issue time, signal is good and RLC Layer is normal

    In abnormal case, time between 100 trying and QCI 1 Bearer with 183 session progress is

    more than 20000ms

    In this event time is only depend on IMS core side

  • 7/26/2019 VoLTE Call Drop for Training_0307

    10/15

    Issue CLOT(BR-RNCH-0258)

    In abnormal case, time between 100 trying and QCI 1 Bearer with 183 session progress is more

    than 20000ms

    SAMSUNG Electronics Co., Ltd. Confidential and Proprietary

  • 7/26/2019 VoLTE Call Drop for Training_0307

    11/15

    Issue CLOT(BR-RNCH-0258)

    During the issue time, signal is good and RLC Layer is normal

    SAMSUNG Electronics Co., Ltd. Confidential and Proprietary

  • 7/26/2019 VoLTE Call Drop for Training_0307

    12/15

    Issue CLOT(BR-RNCH-0258)

    During the issue time, There is only depend on IMS core side

    SAMSUNG Electronics Co., Ltd. Confidential and Proprietary

  • 7/26/2019 VoLTE Call Drop for Training_0307

    13/15

    Issue CLOT(BR-RNCH-0258) During the issue time, There is only depend on IMS core side

    SAMSUNG Electronics Co., Ltd. Confidential and Proprietary

  • 7/26/2019 VoLTE Call Drop for Training_0307

    14/15

    Server error Code

    Appendix(SIP Response Table)

    13 SAMSUNG Electronics Co., Ltd. Confidential and Proprietary

    Error Code Contents

    500 Internal Server Error

    501 Not Implemented

    502 Bad Gateway

    503 Service Unavailable

    504 Server Timeout

    505 SIP Version Not Supported

    513 Message Too Large

  • 7/26/2019 VoLTE Call Drop for Training_0307

    15/15

    Copyright and Confidentiality

    Copyright 2014 SAMSUNG Electronics Co., Ltd. SAMSUNG Electronics reserves the right to make changes to the specifications

    of the products detailed in this document at any time without notice and obligation to notify any person of such changes.

    Information in this document is proprietary to SAMSUNG Electronics Co., Ltd. No information contained here may be copied,

    translated, transcribed or duplicated by any form without the prior written consent of SAMSUNG Electronics.