volume - 4engineeringprojects.com/tender/uploadfiles/2985_vol_3.pdf · - amul traps are available...
TRANSCRIPT
NIT No: PAT/CON/721/01
FOR Tender for “Design and Consultancy for setting up Refrigration Plant (40 TR) for chilled water
system for 20 KLPD ICE Cream plant at Phulwarisharif,Patna”.
VOLUME - 4
ENGINEERING PROJECTS (INDIA) LIMITED (A GOVT. OF INDIA ENTERPRISE)
Core-3, Scope Complex, 7, Lodhi Road, New Delhi-110003
TEL NO: 011-24361666 FAX NO. 011- 24363426
PROJECT
RaviCHECKED BY
DEALT BY NORTHSCALE
DRG. TITLE:
GROUND FLOOR PLAN
Narendra
BUILDING :
ICE-CREAM PLANT
APPROVAL RECORDREFERANCE CONSTRUCTION
DATE
ARCHITECTS:
CONSTRUCTION AGENCY:
CLIENT: -
COMFED
Bihar State Milk Co- Operative Federation Ltd.
DRAWING RELEASED FOR:-
ABHIKARMthe architect studio
20K L.P.D. ICE-CREAMPLANT AT PATNA.
JAN. - 2016 1:100
DRG. NO:
NOTES:# All dimensions are in MM.
# Any discrepancy in this drawing must be brought to the notice of
the architect before execution of work.
# Drawings need not be scaled,only written dimensions shall be
followed.
# This drawing is released for the purpose of civil construction only.
# All Drawings are inter related and shall be read in conjunction with
all other relevant architectural, structural and other service drawings.
# The civil contractor shall check with contractors of other services
that the required provision for anchors, clamps, holes,
shelves,conduit, pipes, hanger and holdfast etc. is made before
casting of concrete masonry work plastering and other work.
# Specifications should be strictly followed to avoid variations.
# Slabs of toilets shall be sunk as per structural drawings.
# Works in charge at site must ensure that due provision of sleeves
etc for sanitary electrical and fire fighting pipes are kept before
casting of beam columns slab and retaining walls.
# For specifications, finishes and other details refer the relevant
drawings.
# Provision of Dowels shall be made as/structural drawings.
ICE CREAM PLANT/ARCH./PATNA/ 04A
COMPRESSOR AREA ROOM- 11880x4000
PROCESSING AREA11880X16590
OFFICE5680 X 2925
BLAST ROOM
COLD ROOM-2 AREA 17585x10500 COLD ROOM-1 AREA
11845x17335
2925 MM. WIDE CORRIDOR
AIR LOCK4500 X 4275
6980 X 4275SUGAR & POWDER STORAGE
11880X4275
ICE CREAM MAKING & PACKING11770X20820
WASHED CRATE ROOM11805X3485
UP
ENTRY4960X3050
17670x4275PACKING MATERIAL STORE
17545 X 7015
Slab lvl.+6000
Slab lvl.+6000
Slab lvl.+3500
Slab lvl.+3500
Slab lvl.+3500
Slab lvl.+6000 Slab lvl.+3500
Slab lvl.+3500
Slab lvl.+3500
Slab lvl.+3500
Slab lvl.+3500
UPlvl. -1200
finish floor lvl
finish floor lvl
finish floor lvl
finish floor lvl
ELECTRICAL PANEL
3000x4275CHANGEROOM
2650x4275 Sb. lvl.+3500Sb.lvl.+3500
D2
DISPATCHOFFICE
150 MM THICK PUFPARTITION
150 MM THICK PUFPARTITION
600 X600 MM. BRICK CUT IN WALL
FROM 900 MM. HT. FROM FINISH
FLOOR LVL.
600 X600 CUT IN WALL
FROM 900 MM FROM FFL
D2D2 D2
D2
D1
D1
D1
1500 MM. WD. 29.870 METER LONG CANTILEVER
PROJECTION AT PLINTH LVL.
lvl. ±00
RSRS
1500
RS RS RS
Width =1500Riser =145Tread =300
SD1
D2
W
WWWWWW
W
W/V
D1
D1
A
SD
SD
SD
SD
SD
SD
finish floor lvl
MS JALI WORK FROM CILL LVL.
TO FIRST BEAM BOTTOM LVL.
FRONT ELEVATION
REAR SIDE ELEVATION
LE
FT
S
ID
E E
LE
VA
TIO
N
RIG
HT
S
ID
E E
LE
VA
TIO
N
SR. NAME SIZE IN MM. LINTEL LVL. REMARKS1. D1 2000 x 2100 21002. D2 1200 x 2100 2100
4. SD 1200 x 2100
5. RS 2400 x 2100 21006. W 1800 x 1200 2100
TO BE
DISPATCH
OPENING SCHEDULE :-
LEGENDS :- AIR CURTAIN
BB
X Y Z
X Y Z
M.S. RAILING
INSTALLED BY MAGNUM
2. SD1 2000x2100 2100
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10
X8
X7
X6
X5
X4
X3
X2
X1
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10
X8
X7
X6
X5
X4
X3
X2
X1
S.N.
REVISION
APPROVAL RECORDREFERANCE CONSTRUCTION
DESCRIPTIONS INITIAL
1. 02-01-2016
DATE DRG. NO . 3A ADDGRID REVISED, &
2. 28-01-2016 SLAB HEIGHT AND
2578
5
AT ±00 LVL
BEAM AS PER
BEAM AS PER
SECTION AT M-M'
BEAM AS PER
STRUCTURE
BEAM AS PER
STRUCTURE
1201
900
2149
2950
900
M.S. JALI
AREA
COMPRESSOR
M
M'
GROUND FLOOR AREA -
1425.00 SQM.
ENTRY REVISED
19320 4960 29870
EQ18
00EQ
EQ18
00EQ
115
1200
5650
1050
8974 1050 1451 1050
2035
150110501586600838
1045
1050
230600
350
1118
1800
1118
350
1500
230
4275
230
1733
523
034
85
350
3900 1800
350
2800
350 450
2400 770450
2400 1800
230 350
920
230
1250 2000 1250 350 1800 1900 1800
350
428 1800 428 115480 1800 600
350
1587 2400 1587342 1745 2400 1587 350 1512 2400 1638
350
3650 2000 1283 1968 1249 1200 4300
1200 2263 1050 2263
1200
1200
230
11880 230 6980230 4500 230
5740230
2655 115 3000230
17670
230
230
5680
230
11635230
230
4275
230
1659
0
230
4000
230
11770
11880
230
LVL. ±00
LVL. ±00
GLASS WALLLAB
5985X3630
AMMONIA RECEIVER AREA
2000
12400
EQ18
00EQ
TOTAL AREA 24.80 SQM.
UP
ADDITIONAL AREA DUE TO PLINTH BEAM PROJECTION
REAR SIDE BETWEEN GRID (Y1-Y2) FOR AMMONIA
RECEIVER AREA= 12.4X2.0 = 24.80 SQM.
LVL. ±00
lvl. -1200
TREAD - 300RISER - 150WIDTH -1500
TREAD - 300RISER - 150WIDTH -2000
TREAD - 300RISER - 150WIDTH -1500
898
2000
237
D3W/V W/V
W/V
W/V
W/V
EVAPORATOR UNIT
230 MM BRICK WALL
EVAPORATOR UNIT
EVAPORATOR UNIT
120 MM THICKINSULATION PARTITION
120 MM THICKINSULATION PARTITION
120 MM THICKINSULATION PARTITION
120 MM THICKINSULATION PARTITION
50 MM THICKINSULATION PARTITION
50 MM THICKINSULATION PARTITION
120 MM THICKINSULATION PARTITION
50 MM THICKINSULATION PARTITION
230 MM BRICK WALL
120 MM THICKINSULATION PARTITION
230 MM BRICK WALL
120 MM THICKINSULATION PARTITION
HOT WATER/
PROJECT BY :
COLD WATER TANK
SS DRAIN CHAMBER 600MMX 600MM X 600MM
AMUL TRAP AMUL TRAP
AMUL TRAP AMUL TRAP
AMUL TRAP AMUL TRAP
3960 3960 3960
4148
3960 3960 3960
3960 3960 3960
4148
4148
4148
AMUL TRAP AMUL TRAP
3960
3960
3960
AMUL TRAP AMUL TRAP
AMUL TRAP AMUL TRAP
AMUL TRAP AMUL TRAP
3960 3960
4148
3960 3960
3960 3960 3960
4148
4673
4148
3960
3960
4367 4367 4367 4568
AMUL TRAP AMUL TRAP AMUL TRAP
AMUL TRAP AMUL TRAP 4000 4000 4000
1580
2137
2137
AMUL TRAP
3850 3130
2138
Following are the Main Features of Amul Trap :-
Description / Specification of Amul Trap.
- Amul Traps are used as drainage point in Dairy and Allied industries. - Material of Construction may be completely SS304 or Ci with Chrome plated Top Jali.- Amul Traps are available in tow profiles. i.e. Square and Circular.- Generally Amul Traps are of 300 mm Size (Top Surface Dimension ) with outlet of 4" Dia.- Most common area of Working of SS Amul Trap is in laboratories. and of CI Amul Trap is
at all the part of Dairy Industries from Where the dirty water, chemical , etc.is drained off.
Sample Availability : yesSupplier product code : ATSS
Competitive Advantages of the product -Used drainage system. SS Amul Traps are used generally in laboratories.
COLD ROOM - 2 CONDENSING UNITBLAST ROOM CONDENSING UNIT COLD ROOM - 1 CONDENSING UNITG.I. / PVCROOF
G.I. / PVCROOF
G.I. / PVCROOF
ALL CONDENSING UNIT TO BE PLACED ON TARRACE AND COVERED BY OVERHEAD GI / PVC SHED
COMPRESSOR AREA ROOM- 11880x3230
PROCESSING AREA11880X16590
OFFICE5680 X 2925
BLAST ROOM
COLD ROOM-2 AREA 17585x10650
COLD ROOM-1 AREA11845x17335
2925 MM. WIDE CORRIDOR CORRIDOR
AIR LOCK4500 X 42756980 X 4275
SUGAR & POWDER STORAGE11880X4275
ICE CREAM MAKING & PACKING11770X20820
WASHED CRATE ROOM - 11810X3485
UP
ENTRY4500X3050
DISPATCH17670x4275
PACKING MATERIAL STORE
17545 X 7015
Slab lvl.+6000
Slab lvl.+6000
Slab lvl.+6000
Slab lvl.+3500
Slab lvl.+3500
Slab lvl.+3500
Slab lvl.+3500
Slab lvl.+3500
Slab lvl.+3500
Slab lvl.+3500
UP
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10
lvl. -1500
lvl. ±00
lvl. ±00
lvl. ±00
lvl. ±00
lvl. ±00
X1
X2
X3
X4
X5
X6
X7
X8
X1
X2
X3
X4
X5
X6
X7
X8
TREAD - 300RISER - 150WIDTH - 1500
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10
X1
X2
X3
X4
X5
X6
X7
X8
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10
6000 6000 6000 6000 5850 6000 5925 6075225225
53700
50
175
3535
3535
3535
3535
3635
3275
4385
175
2543
525
785
54150
X1
X2
X3
X4
X5
X6
X7
X8
MIX AEGING TANK
CIP PHE
MILK CONC.STORAGE
BUTTERMELTER
MIX PREPARATION SYSTEMMIX HEATER
CONC. CHILLERMIX
PASTEURIZER
HOMOGENIZER
HOLDING
TUBE
CHOCOLATE
CHOCOLATEMELING VAT TANK
STORAGE VAT TANK
ACID TANK
LYE TANK
HOT WATER TANK
5 KL 2 KLPH
2 KLPH
5 KL
500 LTR.
500 LTR.
2,000 KG/HR
3 KL
3 KL
3 KL
20 KL/HR
1000 LTR.
MIXING TANK2 KL
SHEARBLENDER
MIX AEGING TANK5 KL
MIX AEGING TANK5 KL
CONE FILLING M/C
CUP FILLING M/C
MANUAL CANDY PLANT
CANDY FREEZER FOR
FLAVOURMIXING TANK FREEZER FOR
BULK PACK
FRUITFEEDER RIPPLE
FREEZER FOR CUP / CONE
100 LTR.
FLAVOURMIXING TANK
100 LTR.
FLAVOURMIXING TANK
100 LTR.
20-200 LPH 2 L/MIN
FRUITFEEDER RIPPLE
20-200 LPH 2 L/MIN
12,000 PC / HR
6000 PC / HR
AIR
CURT
AINE
R-1
AIR CURTAINER-2 AIR CURTAINER-3
AIR CURTAINER-4
COM
PRES
SOR
UNIT
AIR CURTAINER-7
AIR CURTAINER-8
EVAPORATOR UNIT
REFRI. PANEL
3000x4275CHANGEROOM
2650x4275 Sb. lvl.+3500Sb.lvl.+3500
D2
DISPATCHOFFICE
230 MM BRICK WALL
LAB 5980X3630 glaas wall
AMMONIA RECEIVER AREA
SD
SD
SD
SD
600 X600 CUT IN WALLFROM 900 MM FROM FFL
600 X600 CUT IN WALLFROM 900 MM FROM FFL
EVAPORATOR UNIT
EVAPORATOR UNIT
585015
0020
00
E
E
E
E
EE
2000
2000
1050
1165
2000
1200
SD
D2
D2 D2
D2
D1
D1
D1
1500 mm. wd.cantilever
projection at plinth & slab lvl.
1500 mm. wd.cantilever
projection at plinth & slab lvl.
lvl. ±00
lvl. ±00
lvl. ±00
RSRS RS RS RS
1500
19550 30100
GROUND FLOOR PLAN
Slab lvl.+3500Slab lvl.+3500 Slab lvl.+3500
380
Width =1500Riser =145Tread =300
DRAIN CHANNEL
DRAIN CHAMBER
DRAIN LINE
120 MM THICKINSULATION PARTITION
120 MM THICKINSULATION PARTITION
120 MM THICKINSULATION PARTITION
120 MM THICKINSULATION PARTITION
50 MM THICKINSULATION PARTITION
50 MM THICKINSULATION PARTITION
120 MM THICKINSULATION PARTITION
50 MM THICKINSULATION PARTITION
230 MM BRICK WALL
230 MM BRICK WALL
D2 ELECTRICAL PANEL
OF MAIN CHAMBER WITH SLOPECONNECTING TO DRAIN CHANNEL
OF 1 METER.
OF EXISTING PLANT WITH SLOPECONNECTING TO DRAIN CHANNEL
OF 1 METER.
DOTED LINE UNDERGROUND DRAIN
DRAIN CHANNEL DRAIN CHANNEL
DRAIN CHANNEL
DRAIN CHANNEL
DRAIN CHANNEL
DRAIN CHANNEL DRAIN CHANNEL
120 MM THICKINSULATION PARTITION
230 MM BRICK WALL
120 MM THICKINSULATION PARTITION
WITH SLOPE OFDRAIN CHANNEL
6" TO CHAMBER
WITH SLOPE OFDRAIN CHANNEL
6" TO CHAMBER
WITH SLOPE OFDRAIN CHANNEL
6" TO CHAMBER
DRAIN CHAMBER 600MMX 600MM X 600MM
DRAIN CHAMBER
DRAIN CHAMBER
DRAIN CHAMBER
DRAIN CHAMBER DRAIN CHAMBER DRAIN CHAMBER 300MMX 300MM X 300MM
DRAIN CHAMBER
DRG.GIVEN SEPARATELY WITH COVERED OPENED DRAINED CHANNEL AS PER
SS JALI
DRG.GIVEN SEPARATELY WITH COVERED OPENED DRAINED CHANNEL AS PER
SS JALI
DOTED LINE UNDERGROUND DRAIN
DOTED LINE UNDERGROUND DRAIN
DOTED LINE UNDERGROUND DRAIN
900MMX 900MM X 900MM
600MMX 600MM X 600MM
600MMX 600MM X 600MM
600MMX 600MM X 600MM
300MMX 300MM X 300MM300MMX 300MM X 300MM
DOTED LINE UNDERGROUND DRAIN IN PLANT
WITH SLOPE OFDRAIN CHANNEL
6" TO CHAMBER
DRAIN CHAMBER 600MMX 600MM X 600MM 600MMX 600MM X 600MM