voyager-de pro absciex user guide.pdfvoyager-de pro absciex instructional guide prepared by emanuel...
TRANSCRIPT
![Page 1: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/1.jpg)
Voyager-DE PROABSciex
Instructional Guideprepared by Emanuel Schreiber
May 28, 2015
![Page 2: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/2.jpg)
The MALDI-Tof System
Logbook
Target Viewing Monitor
Instrument Computer
Joy Stick
Mass Spectrometer
Target plate loading arm
![Page 3: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/3.jpg)
Double click on Voyager Control Panel Icon
To Start the Voyager Software
![Page 4: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/4.jpg)
Status barOutput window
Spectrum window
Manual Laser/ Sample Position Control page
Data Storage Control page
Instrument Settings Control page
Instrument settings file nameToolbar
Instrument Control Panel
![Page 5: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/5.jpg)
1) Instrument-ON2) High Voltage-OFF3) Vacuum: Source (green) less than e-06
Mirror (green) less than e-07
1 2 3
Before running instrument• sign in logbook • check the status bar
![Page 6: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/6.jpg)
Ejecting MALDI Plate Holder
1) Click on “hand” icon on tool bar.2) Click on Eject… button.3) Holder will be exposed.
1
2
3
![Page 7: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/7.jpg)
Sliding plate onto holder
1) Slide plate into holder (from right to left). NOTE: Well numbers on plate will be upside down as you look down at plate.2) Plate will “snap” into place when balls aligns with holes in plate. Base on right side.3) IMPORTANT make sure plate is in holder correctly, or the plate may fall off holder inside instrument. (You don’t want this to happen)
1
23
![Page 8: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/8.jpg)
1) Click on “hand” icon on toolbar2) Select Plate ID, 100 Well Plate.3) Click on Load… button. Plate will then
move into instrument.
Loading MALDI Plate
2
3
1
![Page 9: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/9.jpg)
Running a SampleA. Turn on High VoltageB. Load instrument methodC. Input sample informationD. Move target into positionE. Fire laser and collect dataF. Save dataG. Remove plate
A) Turning on the high voltage1) Click on the high voltage icon on toolbar.2) High voltage will ramp up.3) Wait till high voltage is finished ramping.
1
2
3
![Page 10: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/10.jpg)
B) Load instrument method1) Click on File option on menu bar.2) Select “Open Instrument Setting…” from drop down menu.3) Methods are stored in the Methods folder under Data.4) Select method and open file. (methods may also be saved in your folder)
1
2
3
4
![Page 11: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/11.jpg)
C) Input sample information
1) Select a directory (you should create a directory with your name under your advisor’s directory).
2) Fill in filename.3) Fill in sample description.
1
2
3
![Page 12: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/12.jpg)
D) Moving target into position
Three methods for moving target:1) Use active position dropdown or type well #.2) Click on well in picture of plate.3) Use joy stick to move target manually.
1
2
3
![Page 13: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/13.jpg)
E) Firing laser and collecting dataTwo ways to fire laser1) Use button on joy stick handle.2) Use the acquisition start/stop icon on toolbar.Collecting data3) Laser will fire for the number of shots specified in method.4) Move target around in well so that the laser is not hitting
the same spot in well the entire time.
1
2
3
![Page 14: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/14.jpg)
F) Saving data1) Click on save data icon on toolbar.2) Data will be saved into directory and file specified in the data
storage control page.3) Confirmation of file storage will appear in the output window.
1
2
3
![Page 15: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/15.jpg)
G) Removing plate
1) Click on the high voltage icon on toolbar. Wait for voltage to turn off on status bar.
2) Click on “hand” icon on tool bar.3) Click on Eject… button.4) Holder will be exposed.5) Slide Plate out of holder.6) Click on “hand” icon on tool bar.7) Click on Load No Plate. Holder
will then move inside instrument.
1 2
34
5
6 7
![Page 16: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/16.jpg)
Viewing Data
Double Click on Data Explorer Icon
![Page 17: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/17.jpg)
Opening Data Files
1) Click on open file icon on toolbar.2) Select folder to look in.3) Select data file.4) Click Add button.5) Repeat process to add additional files.6) Click on Finish button.
1
2
3
4
5
6
![Page 18: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/18.jpg)
Data Explorer Example of two data files opened.1) Cal Mix 1 in Reflector mode.2) Cal Mix 2 in Linear mode.
1
2
![Page 19: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/19.jpg)
Baseline Correction
1) Open your data file in Data Explorer.
2) Select Baseline Correction from Process pulldown menu.
3) Baseline corrected spectrum will appear.
1
3
2
![Page 20: Voyager-DE PRO ABSciex user guide.pdfVoyager-DE PRO ABSciex Instructional Guide prepared by Emanuel Schreiber May 28, 2015. The MALDI-Tof System Logbook Target Viewing Monitor Instrument](https://reader034.vdocuments.net/reader034/viewer/2022042407/5f224c0b84d90d5aec53cd68/html5/thumbnails/20.jpg)
Curve Smoothing
3
1) Select Noise Filter/Smooth… from Process dropdown menu.
2) Select Gausian Smooth from dropdrop down menu and Filter Width 5 points.
3) Click OK.
Before Smoothing
After Smoothing
1
2
3