Material Safety Data Sheetacc. to ISO/DIS 11014
Printing date 08/29/2011 Reviewed on 08/29/2011
1Identification of the substance/mixture and of the company/undertaking
Product identifier
Trade name: VpCI-101Application of the substance / the preparation Corrosion inhibitors
Details of the supplier of the safety data sheetManufacturer/Supplier:Cortec Corporation4119 White Bear ParkwaySt. Paul, MN 55110 USAPhone (651) 429-1100
Fax (651) 429-1122
Information department: [email protected] telephone number: Chemtrec (for spill, leak, fire exposure or accident): 1-800-424-9300
2Composition/information on ingredients
Chemical characterization: Mixtures
Description:Mixture of the substances listed below with nonhazardous additions.
Dangerous components: Void
Additional information For the wording of the listed risk phrases refer to section 16.
3Hazards identification
Classification of the substance or mixtureThe product is not classified according to the Globally Harmonized System (GHS).
Classification according to Directive 67/548/EEC or Directive 1999/45/ECVoid
Information concerning particular hazards for human and environment: not applicable
Label elements
GHS label elements VoidHazard pictograms Void Signal wordVoidHazard statements Void
Classification systemHMIS rating system (0-4)
HEALTH
FIRE
REACTIVITY
1
1
0
Health = 1Flammability = 1
Reactivity = 0
4First aid measures
After inhalation Supply fresh air; consult doctor in case of complaints.After skin contactImmediately wash with water and soap and rinse thoroughly.
After eye contactRinse opened eye for several minutes under running water.
After swallowingIf symptoms persist consult doctor.USA
(Contd. on page 2)
-
7/26/2019 VpCI-101_MSDS.pdf
2/5
Page 2/5
Material Safety Data Sheetacc. to ISO/DIS 11014
Printing date 08/29/2011 Reviewed on 08/29/2011
Trade name: VpCI-101
(Contd. of page 1)
5Firefighting measures
Suitable extinguishing agents
CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam. Special hazards arising from the substance or mixtureCarbon monoxide (CO)
Nitrogen oxides (NOx)
Hydrogen cyanide (HCN)Protective equipment: Wear self-contained respiratory protective device.
6Accidental release measures
Personal precautions, protective equipment and emergency proceduresNot required.Environmental precautions:Do not allow to enter sewers/ surface or ground water.
Methods and material for containment and cleaning up: Pick up mechanically.
Reference to other sectionsNo dangerous substances are released.
7Handling and storage
HandlingPrecautions for safe handling Store in cool, dry place in tightly closed receptacles.Information about protection against explosions and fires:No special measures required. StorageRequirements to be met by storerooms and receptacles: Store in a cool location.Information about storage in one common storage facility: Store away from foodstuffs.Further information about storage conditions:None. Specific end use(s)No further relevant information available.
8Exposure controls/personal protection
Additional information about design of technical systems:No further data; see item 7. Components with limit values that require monitoring at the workplace:The product does not contain any relevant quantities of materials with critical values that have to be monitored atthe workplace.
Additional information: The lists that were valid during the creation were used as basis.Personal protective equipment General protective and hygienic measuresThe usual precautionary measures for handling chemicals should be followed.
Breathing equipment:Not required.
Protection of hands: Protective gloves
Penetration time of glove materialThe exact break through time has to be found out by the manufacturer of the protective gloves and has to beobserved.
Eye protection:Not required.USA
(Contd. on page 3)
-
7/26/2019 VpCI-101_MSDS.pdf
3/5
Page 3/5
Material Safety Data Sheetacc. to ISO/DIS 11014
Printing date 08/29/2011 Reviewed on 08/29/2011
Trade name: VpCI-101
(Contd. of page 2)
9Physical and chemical properties
General Information
Appearance:Form: Solid.
Color: Off-white to yellow Odor: Characteristic
Change in conditionMelting point/Melting range: undetermined
Boiling point/Boiling range: undetermined
Flash point: Not applicable
Auto igniting: Product is not selfigniting.
Danger of explosion: Product does not present an explosion hazard.
Density: Not determined
Solubility in / Miscibility withWater: Insoluble
Solvent content:Organic solvents: 0.0 %
Solids content: >96 % Other information The above data are typical values and do not constitute a specification.
10 Stability and reactivity
Thermal decomposition / conditions to be avoided:No decomposition if used according to specifications.
Incompatible materials:No further relevant information available.
Hazardous decomposition products:Nitrogen oxides (NOx)Hydrogen cyanide (prussic acid)
Carbon monoxide
11 Toxicological information
Acute toxicity:Primary irritant effect:on the skin:Repeated or prolonged skin contact with this product may produce skin irritation.
on the eye:No irritating effect.
Sensitization:No sensitizing effects known.
Additional toxicological information:The product is not subject to classification according to the calculation method of the General EU ClassificationGuidelines for Preparations as issued in the latest version:When used and handled according to specifications, the product does not have any harmful effects according toour experience and the information provided to us.
12 Ecological information
Acquatic toxicity:No further relevant information available.
Persistence and degradabilityNo further relevant information available.(Contd. on page 4)
USA
-
7/26/2019 VpCI-101_MSDS.pdf
4/5
Page 4/5
Material Safety Data Sheetacc. to ISO/DIS 11014
Printing date 08/29/2011 Reviewed on 08/29/2011
Trade name: VpCI-101
(Contd. of page 3)
Behavior in environmental systems:Bioaccumulative potentialNo further relevant information available.Additional ecological information: General notes:
Water hazard class 1 (German Regulation) (Self-assessment): slightly hazardous for water.Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system.
13 Disposal considerations
Waste treatment methodsRecommendation Smaller quantities can be disposed of with household waste.
Uncleaned packagings:Recommendation:Disposal must be made according to official regulations.
14 Transport information
UN-NumberDOT, ADR, ADN, IMDG, IATA Void
UN proper shipping nameDOT, ADR, ADN, IMDG, IATA Void
Transport hazard class(es)
DOT, ADR, ADN, IMDG, IATA Class Void
Packing groupDOT, ADR, IMDG, IATA Void
Environmental hazards:
Marine pollutant: No
Special precautions for user Not applicable.
Transport in bulk according to Annex II ofMARPOL73/78 and the IBC Code Not applicable.
15 Regulatory information
SARA Section 355 (extremely hazardous substances)
None of the ingredients is listed.
SARA Section 313 (specific toxic chemical listings)
None of the ingredients is listed. TSCA (Toxic Substances Control Act)
All ingredients are listed.
Prop 65 - Chemicals known to cause cancer
None of the ingredients is listed.
(Contd. on page 5)
USA
-
7/26/2019 VpCI-101_MSDS.pdf
5/5
Page 5/5
Material Safety Data Sheetacc. to ISO/DIS 11014
Printing date 08/29/2011 Reviewed on 08/29/2011
Trade name: VpCI-101
(Contd. of page 4)
Cancerogenity categories
EPA (Environmental Protection Agency)
None of the ingredients is listed.
IARC (International Agency for Research on Cancer)
9009-54-5 Polyurethane foam 3
NTP (National Toxicology Program)
None of the ingredients is listed.
NIOSH-Ca (National Institute for Occupational Safety and Health)
None of the ingredients is listed.
OSHA-Ca (Occupational Safety & Health Administration)
None of the ingredients is listed.
GHS label elements Void
Hazard pictograms Void
Signal wordVoidHazard statements Void
16 Other information
This information is based on our present knowledge. However, this shall not constitute a guarantee for anyspecific product features and shall not establish a legally valid contractual relationship.
Abbreviations and acronyms:ADR: Accord europen sur le transport des marchandises dangereuses par Route (European Agreement concerning the International
Carriage of Dangerous Goods by Road)
RID: Rglement international concernant le transport des marchandises dangereuses par chemin de fer (Regulations Concerning theInternational Transport of Dangerous Goods by Rail)
IMDG: International Maritime Code for Dangerous Goods
IATA: International Air Transport Association
ICAO: International Civil Aviation OrganizationHMIS: Hazardous Materials Identification System (USA)
USA