© Danfoss | 2017.01 VI.LH.M3.00 | 1 VRB2, VRB 3, VRG 2, VRG 3 DN 15-50 Operating Guide MAINTENANCE FREE + AMV(E) 335, 435 VRB 3, VRG 3 (DN 15-50) VRB 2, VRG 2 (DN 15-50) AMV / AME IP 54 AMV(E) 335/435 IP 54 AMV(E) 438 SU AMV(E) 25 (SU/SD), 35 AMV(E) 25 (SU/SD), 35 + adapter 065Z0311 AMV(E) 438 SU

Upload: others

Post on 09-Jul-2020

24 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: VRB2, VRG2 / VRB3, VRG3 · vrb2, vrb 3, vrg 2, vrg 3 dn 1550 operating guide maintenance free + amv(e) 335, 435 vrb 3, vrg 3 (dn 15-50) vrb 2, vrg 2 (dn 15-50) ˜˚˛˝˙ˆˇ˝˘

© Danfoss | 2017.01 VI.LH.M3.00 | 1

VRB2, VRB 3, VRG 2, VRG 3 DN 15-50Operating Guide

MAINTENANCEFREE

+AMV(E) 335, 435

VRB 3, VRG 3 (DN 15-50)

VRB 2, VRG 2 (DN 15-50) ������������

AMV / AME

IP 54 AMV(E) 335/435

IP 54 AMV(E) 438 SU

AMV(E) 25 (SU/SD), 35

AMV(E) 25 (SU/SD), 35 + adapter 065Z0311

AMV(E) 438 SU

Page 2: VRB2, VRG2 / VRB3, VRG3 · vrb2, vrb 3, vrg 2, vrg 3 dn 1550 operating guide maintenance free + amv(e) 335, 435 vrb 3, vrg 3 (dn 15-50) vrb 2, vrg 2 (dn 15-50) ˜˚˛˝˙ˆˇ˝˘

2 | © Danfoss | 2017.01 VI.LH.M3.00

VRB 2, VRB 3, VRG 2, VRG 3

FVR/FVF

AMV(E)

−10°C / 2°C

+

PN 16

VRB 2, VRB 3CuSn5ZnPb (Rg5)

VRG 2, VRG 3EN-GJL-250 (GG-25)

PN 16

Stem heater 065Z0315

DN Actuators

15-50

AMV(E) 335AMV(E) 435

AMV(E) 438 SUAMV(E) 25 (SU/SD) + adapter

AMV(E) 35 + adapter

Page 3: VRB2, VRG2 / VRB3, VRG3 · vrb2, vrb 3, vrg 2, vrg 3 dn 1550 operating guide maintenance free + amv(e) 335, 435 vrb 3, vrg 3 (dn 15-50) vrb 2, vrg 2 (dn 15-50) ˜˚˛˝˙ˆˇ˝˘

© Danfoss | 2017.01 | 3VI.LH.M3.00

VRB 2, VRB 3, VRG 2, VRG 3

B

1)2)

A

VRB 2, VRG 2 + AMV(E) 438 SU,

AMV(E) 25 (SU/SD), 35 +

adapter 065Z0311

L

min. 100

HH

2

A

VRB 2, VRG 2 + AMV(E) 335, 435

L

H

min. 20,5

H1

A

VRB 2 + AMV(E) 335, 435

L

min. 20,5

HH

1

B

VRB 2 + AMV(E) 438 SU,

AMV(E) 25 (SU/SD), 35 + adapter 065Z0311

L

min. 100

HH

2

B

VRB 2, VRG 2 +AMV(E) 335, 435

min. 20,5

L

HH

1

A

VRB 2, VRG 2 +AMV(E) 438 SU,

AMV(E) 25 (SU/SD), 35 + adapter 065Z0311

L

HH

2

min. 100

A

VRB 3 + AMV(E) 335, 435

min. 20,5

L

HH

1

B

VRB 3 + AMV(E) 438 SU,

AMV(E) 25 (SU/SD), 35 +

adapter 065Z0311

L

HH

2

min. 100

B

Rp

L1

Rp

L1

H3

B

1)2)

A

Type DN Rp 1) G 2)L L1 H H1 H2

mm

VRB 2VRG 2

15 ½ 1 80 128 25 191 216

20 ¾ 11/4 80 128 29 194 218

25 1 11/2 95 151 29 197 222

32 11/4 2 112 178 35 202 226

40 11/2 21/4 132 201 43 213 237

50 2 2 ¾ 160 234 47 217 242

1) Rp EN 10226-1 2) G DIN ISO 228/01

Type DN Rp 1) G 2)L L1 H H1 H2 H3

mm

VRB 3VRG 3

15 ½ 1 80 128 40 191 216 64

20 ¾ 11/4 80 128 45 194 218 69

25 1 11/2 95 151 50 197 222 78

32 11/4 2 112 178 58 202 226 91

40 11/2 21/4 132 201 75 230 255 110

50 2 2 ¾ 160 234 83 243 268 120

1) Rp EN 10226-1 2) G DIN ISO 228/01

Page 4: VRB2, VRG2 / VRB3, VRG3 · vrb2, vrb 3, vrg 2, vrg 3 dn 1550 operating guide maintenance free + amv(e) 335, 435 vrb 3, vrg 3 (dn 15-50) vrb 2, vrg 2 (dn 15-50) ˜˚˛˝˙ˆˇ˝˘

4 | © Danfoss | DHS-SRMT/SI | 2017.01 73691580 / VI.LH.M3.00

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed.All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.