w e m a k e i d e a s c o m e a l i v e 001scb040700 for internal use only peripheral co-cr stent...

18
W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge On the cutting edge of flexibility and strength of flexibility and strength

Upload: melina-amason

Post on 29-Mar-2015

247 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c

o m

e a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

Peripheral Co-Cr Stent System OTW

On the cutting edge On the cutting edge of flexibility and strengthof flexibility and strength

Page 2: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c o

m e

a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

How to get around the “horn” ?How to get around the “horn” ?

It’s all about deliverability…It’s all about deliverability…

Page 3: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c o

m e

a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

First Cobalt-Chromium First Cobalt-Chromium

peripheral Stent, mounted peripheral Stent, mounted

on a 5F Delivery systemon a 5F Delivery system

Page 4: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c

o m

e a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

The StentThe Stent

Page 5: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c o

m e

a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

History of Co-CrHistory of Co-Cr

Co-Cr was used since 1937 in medical implants: more than 30 years of usage in humans

Cage for heart valves

Endo-prosthesis

Aneurysm clips

Pacemaker leads

Co-Cr more biocompatible, stronger, less ferromagnetic, more resistant to fatigue and corrosion than Stainless Steel

Page 6: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c o

m e

a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

Scientific Results Co-CrScientific Results Co-Cr

Co-Cr is STRONGER than Stainless Steel Lower thickness without

decreasing radial force

Co-Cr is around 45% stronger than Stainless Steel

Co-Cr is DENSER than Stainless Steel Good radiopacity despite

thinner struts

Co-Cr is around 6% denser than Stainless Steel

Yield Strength

0

10

20

30

40

50

60

70

Cobalt alloy 316 L Stainless Steel

Ksi

Material Kg per m3

Cobalt alloy

8.415

316L SS 7.944

Page 7: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c o

m e

a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

Specification StentSpecification Stent

Stent designStent design

Range of diameterRange of diameter

Range of lengthRange of length

Stent material Stent material

Strut thicknessStrut thickness

Strut widthStrut width

Closed cell, slotted tube inClosed cell, slotted tube indiameter specific designdiameter specific design

Ø 5, 6, 7, 8, 9, 10 mmØ 5, 6, 7, 8, 9, 10 mm

18, 30, 37, 55, 75 mm18, 30, 37, 55, 75 mm

Cobalt ChromiumCobalt Chromium

120 µ120 µm (5 – 7 mm)m (5 – 7 mm)152 152 µµm (8 – 10 mm) m (8 – 10 mm)

120 120 µµm (5 – 10 mm)m (5 – 10 mm)

Strut thickness 120 mfor 5.0 / 6.0 / 7.0 mm

Strut thickness 152 mfor 8.0 / 9.0 / 10.0 mm

Page 8: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c o

m e

a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

Metal-to-Artery RatioMetal-to-Artery Ratio

16,50%

13,70%

11,80%

14,50%12,90%

11,60%

0%

2%

4%

6%

8%

10%

12%

14%

16%

18%

5.0 mm 6.0 mm 7.0 mm 8.0 mm 9.0 mm 10.0 mm

Metal-to-Artery ratio

small large

Page 9: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c o

m e

a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

Stent DesignStent Design

Cobalt Chromium

Slotted Tube, Laser cut

Closed cell design

Round edges, ultra-polished surfaces

High flexibility of the crimped stent

High radial force and longitudinal flexibility after deployment

Page 10: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c

o m

e a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

The Stent The Stent Delivery SystemDelivery System

Page 11: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c o

m e

a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

Specification SDSSpecification SDS

Catheter designCatheter design

Guide wire Guide wire compatibilitycompatibility

Usable shaft length Usable shaft length

Balloon material Balloon material

CoatingCoating

Shaft diameter Shaft diameter

Tip entry profile Tip entry profile

Introducer Introducer compatibilitycompatibility

Nominal pressureNominal pressure

RBPRBP

Over the wire, dual lumen Over the wire, dual lumen shaftshaft

0.035“0.035“

80, 130 cm 80, 130 cm

FLEXITEC™ XtremeFLEXITEC™ Xtreme

nonenone

5F5F

0.042”0.042”

6F (Ø 5 – 9 mm)6F (Ø 5 – 9 mm)7F (Ø 10 mm)7F (Ø 10 mm)

9 bar9 bar

17 bar17 bar

Page 12: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c o

m e

a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

SDS Type / ConstructionSDS Type / Construction

NEW shaft material for improved pushability and kink resistance combined with excellent flexibility for contro-lateral maneuvers

NEW balloon material FLEXITEC™ Xtreme for improved flexibility and extreme scratch resistance while

maintaining high RBP

NEW tapered tip design

NEW balloon 6-folding for perfect re-wrapping, even after high pressure stent

deployment

NEW packaging for facilitated product handling

Page 13: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c o

m e

a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

Introducer Sheath Introducer Sheath CompatibilityCompatibility

6F

7F

for Ø 5, 6, 7, 8, 9 mm

for Ø 10 mm

Page 14: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c o

m e

a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

Key Selling PointsKey Selling Points

First Peripheral Cobalt Chromium Stent System, First Peripheral Cobalt Chromium Stent System, for for unlimited deliverability and flexibility in contralateral unlimited deliverability and flexibility in contralateral approaches.approaches.

Closed Cell Design, Closed Cell Design, for tight, predictable scaffolding and for tight, predictable scaffolding and appropriate radial force in Iliac lesions.appropriate radial force in Iliac lesions.

Zero stent shortening,Zero stent shortening, for precise placement for precise placement

High performance balloon material,High performance balloon material, featuring Flexitec™ Xtreme Polyamide, for high pressure stent deployment while maintaining high flexibility and scratch resistance.

6 balloon folding, for homogeneous stent deployment and safe retrieval of the delivery system.

Page 15: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c o

m e

a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

Model MixModel Mix

Stent Ø/Length 1880/130cm

3080/130cm

3780/130cm

5580/130cm

7580/130cm

5.0 6.0 7.0 8.0 9.0

10.0

Page 16: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength

W e

m

a k

e i d

e a

s c o

m e

a l i v

e

00

1S

CB

04

07

00

For

inte

rnal u

se o

nly

What are the improvements of What are the improvements of compared tocompared to ? ?

Scuba Invastent Onda

Catheter design Over the wire, dual lumen shaft Over the wire, dual lumen shaft Guide wire compatibility 0.035“ 0.035“ Usable shaft length 80, 130 cm 80, 130 cm Balloon material FLEXITEC™ Xtreme FLEXITEC™ LP Shaft diameter 5F 5F Introducer compatibility 6F (Ø 5 – 9 mm) 6F (Ø 5 – 7 mm) 7F (Ø 10 mm) 7F (Ø 8 mm)

8F (Ø 9 – 10 mm) Nominal pressure 9 bar 7 bar RBP 17 bar 16 bar

Stent design Closed cell, slotted tube in diameter specific design Closed cell, slotted tube

Range of diameter Ø 5, 6, 7, 8, 9, 10 mm Ø 5, 6, 7, 8, 9, 10 mm

Range of length 18, 30, 37, 55, 75 mm 19, 38, 57, 77 mm Stent material Cobalt Chromium Stainless steel Strut thickness 120 µm (5 – 7 mm) 150 µm (5 – 7)

152 µm (8 – 10 mm) 180 µm (8 - 10) Strut width 120 µm (5 – 10 mm) 135 µm (5.0 – 7.0 mm)

180 µm (8.0 – 10.0 mm)

Stent

Stent Delivery System

Page 17: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength
Page 18: W e m a k e i d e a s c o m e a l i v e 001SCB040700 For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength