Installation Instructions 3.5” MX Pendant - Pendant Mounted IMPORTANT SAFETY INSTRUCTIONS Read all installation instructions before installing. It is important to save these instructions. Only install and connect LED module with power disconnected at the circuit breaker. Hot plugging, or connecting the module with power on, could damage the LEDs and is not covered by warranty. Observe and follow all label information and instructions regarding dry, damp and wet location listings, proper Intense LED module, warnings of installation near combustible materials and/or insulation. Be sure to connect ground wire to prevent electric shock or other potential hazards. The product must be installed in a manner consistent with the intended use and in compliance with the national electrical codes and local codes by a person familiar with the construction and operation of the product and the hazards involved. WARNING: Use only Intense Lighting trims listed for use with this fixture. Use of trims other than those listed by Intense Lighting is a violation of N.E.C 110-3(B) and voids all warranties. WARNING Risk of electrical shock. Disconnect power before servicing or installing luminaire. ! WARNING Risk of injury or damage. Luminaire will fail if not installed properly. Follow installation instructions. ! WARNING Risk of injury. Wear safety glasses and gloves during installation and servicing. Allow ample time to cool before handling. ! M3 x 10mm Flat Head TOP COVER REMOVAL: 1. Remove all four M3 x 10mm flat head fasteners and keep for use on lid replacement. 1 2 4 3 FASTENING PENDANT STEM TO FIXTURE: 1. Slide pendant stem through canopy and screw one hex nut before lid and another after lid. Leave 1/4” of pendant thread after lid. Tighten hex nuts together and ensure stem is securely fastened to lid. Canopy Pendant Stem Threaded Knuckle With Set Screw Hex Nut Top Cover With Driver Plate Attached M3 X 10mm Flat Head Driver Wires WIRING PENDANT STEM: 1. Feed wires through pendant stem 2. Make necessary wire connections securely TOP COVER INSTALL: 1. Replace top cover with four M3 x 10mm flat head fasteners INSTRUCTIONS L/M-10022017 P-1 INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321. © 2017 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice. IS-C1031R2 1 OF 6

Upload: others

Post on 31-Jan-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

  • Installation Instructions3.5” MX Pendant - Pendant Mounted

    IMPORTANT SAFETY INSTRUCTIONS – Read all installation instructions before installing. It is important to save these instructions. – Only install and connect LED module with power disconnected at the circuit breaker. Hot plugging, or connecting the module with power

    on, could damage the LEDs and is not covered by warranty. – Observe and follow all label information and instructions regarding dry, damp and wet location listings, proper Intense LED module,

    warnings of installation near combustible materials and/or insulation. – Be sure to connect ground wire to prevent electric shock or other potential hazards. – The product must be installed in a manner consistent with the intended use and in compliance with the national electrical codes and local

    codes by a person familiar with the construction and operation of the product and the hazards involved. – WARNING: Use only Intense Lighting trims listed for use with this fixture. Use of trims other than those listed by Intense Lighting is a

    violation of N.E.C 110-3(B) and voids all warranties.

    WARNING

    Risk of electrical shock. Disconnect power before servicing or installing luminaire.

    !

    WARNING

    Risk of injury or damage. Luminaire will fail if not installed properly. Follow

    installation instructions.

    !

    WARNING

    Risk of injury. Wear safety glasses and gloves during installation and servicing.

    Allow ample time to cool before handling.

    !

    M3 x 10mm Flat Head

    TOP COVER REMOVAL:1. Remove all four M3 x 10mm flat head fasteners and keep for use on lid replacement.

    1 2

    43

    FASTENING PENDANT STEM TO FIXTURE:1. Slide pendant stem through

    canopy and screw one hex nut before lid and another after lid. Leave 1/4” of pendant thread after lid. Tighten hex nuts together and ensure stem is securely fastened to lid.

    Canopy

    Pendant Stem

    Threaded Knuckle With Set Screw

    Hex Nut

    Top Cover With Driver Plate Attached

    M3 X 10mm Flat Head

    Driver Wires

    WIRING PENDANT STEM:1. Feed wires through pendant stem2. Make necessary wire connections securely

    TOP COVER INSTALL:1. Replace top cover with four M3 x 10mm flat head fasteners

    INSTRUCTIONS L/M-10022017 P-1

    INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2017 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

    IS-C1031R21 OF 6

  • 7

    6

    STEM ATTACHMENT TO UNIVERSAL PLATE1. Make sure to leave a slight space between supplied hex nuts attached to the stem2. Hang the stem onto the universal plate at the center retaining area, making sure wire

    connections are inside jbox area and securing canopy cover in position as shown3. Tighten bottom hex nut below the universal plate to secure stem attachment4. Place canopy cover against the universal plate for tooless attachment

    ELECTRICAL CONNECTIONS1. Make electrical connections through the clearance area of the universal plate2. Connect ground wire from universal mounting plate to green (ground) supply wire and

    ground wire from fixture, white wire from cylinder to white (neutral) supply wire and black wire from cylinder to black (hot) supply wire. Use UL listed connectors or wire nuts (by others) to make the connections. Connect dimming wires if applicable, see page 4 & 5.

    Installation Instructions3.5” MX Pendant - Pendant Mounted

    Bottem Hex Nut

    Top Hex Nut

    Universal Plate

    Canopy Cover

    5ATTACH MOUNTING BRACKET TO JUNCTION BOX:1. Attach universal plate to junction box2. Run wires through center clearance area of universal plate3. Attach universal mounting plate to junction box by 2 x 8-32 pan head screws4. Insure universal plate is flush to ceiling line and free of joint compound and debris

    8-32 Pan Head

    Universal Slot Attachment

    3.0 Box Keyed Attachment with Mud plate

    4.0 Box Keyed Attachment

    INSTRUCTIONS L/M-10022017 P-2

    INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2017 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

    IS-C1031R22 OF 6

  • Installation Instructions3.5” MX Pendant - Remote Driver & Accessories

    Release Cap

    Accessories

    Accessory Holder

    Accessory Holder’s Retaining Clip

    Module

    ACCESSORY HOLDER:1. Rotate release cap by turning counter clockwise.2. Install accessories into accessory holder and replace accessory holder’s retaining clip.3. Place accessory holder and accessory flush against optic and replace release cap.

    OPTIC REPLACEMENT:1. Remove trim, then remove module from channel and disconnect quick connect.2. Rotate release cap by turning counter clockwise.3. Set cap and retainer ring aside and change optics.4. Align optic pins to slots in module.

    Release Cap

    Retainer Ring

    Optic

    ModuleOptic Slots

    1 2

    Remote Driver Housing Installation

    Accessory & Optics Installation

    REMOTE BOX INSTALLATION1. Remove two 8-32 fasteners and save to reinstall cover plate2. Remove cover plate3. Remove required knockouts and run conduit to junction box fixture is attached to

    (**maximum 50 feet length from fixture”)

    Remote Box

    Cover Plate

    Two 8-32 Fasteners Supllied With Housing

    REMOTE BOX INSTALLATION1. Run connecting wires for LED driver class 2 by local and national electrical regulations,

    minumun 18 awg wire and at maximum 50 feet length2. Attach remote box at two 1/4” holes on 6 inch centers with frame in installation

    hardware (supplied by others)3. Make electrical connections (See Page 2, Step 6)4. Reinstall cover plate with supplied 8-32 hardware, insure wires are clear of box edges

    not pinched or damaged when cover is screwed down

    NOTE: ***NOT RATED FOR THROUGH WIRING***

    Suppliesby others

    Ground Fastener

    LED Driver Cover Supplies

    by others

    Frame In Installation Hardware (Supplied By Others)Two Ø1/4” Holes On 6 Inch Center

    INSTRUCTIONS L/M-10022017 P-3

    INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2017 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

    IS-C1031R23 OF 6

  • Installation Instructions3.5” MX Pendant - Pendant Mounted

    DRIVER REPLACEMENT: DRIVER TYPE 1: DRIVER REPLACEMENT: DRIVER TYPE 2:M3 x 10mmFlat Head

    Driver Plate Driver Plate

    8-32 Nut

    M3 Nut

    Bottom Feed Driver

    M3 x 10mmFlat Head

    M3 Pan Head

    Small, Side Feed Driver

    Fixture Maintenance

    Trim

    figure 1

    MODULE REMOVAL1. Check that power is off at breaker, hot plugging may damage leds2. Remove Trim (see figure.1)3. Insert #1 flat head screw driver between optic and module cap as shown on detail call out (round pendant only, square pendant use finger to grip module at cap) pull down gently (see figure.2)4. *Take caution not to scratch surface of optic during this step, use #1 flat screw, larger screw driver may damage module*5. Grasp module with hand and fully remove from housing (see figure 3)6. Disconnect quick connect from fixture to module7. Install Follow Steps In Reverse

    *Snap module into channel and confirm module sits parallel to ceiling line and is securely fastened into fixture before reattaching trim or turning power back on to fixture*

    figure 3

    Quick Connect

    Module

    Channel

    25.00°

    B B

    C

    SECTION B-BSCALE 1 : 1

    DETAIL CSCALE 2 : 1

    25.00°

    B B

    C

    SECTION B-BSCALE 1 : 1

    DETAIL CSCALE 2 : 1

    #1 Flat Head Screw Driver

    Detailed View

    figure 2

    Module Cap

    Optic

    INSTRUCTIONS L/M-10022017 P-4

    INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2017 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

    IS-C1031R24 OF 6

  • Installation Instructions3.5” MX Pendant - Dimming Compatibility

    DMX512 RDM DIMMING ■ 120V or 277V ■ Dims down to 0.1% light output ■ RDM channel programmable

    LED LIGHT ENGINE

    DMX512 IN

    120 OR 277V INPUT

    DRIVER

    ORANGE (DMX -)

    BROWN (DMX GROUND)

    ORANGE/WHITE (DMX +)

    BLACK

    WHITE

    GREENBLACK - NEGATIVE

    RED - POSITIVE

    FORWARD / REVERSE PHASE DIMMING ■ 120V only ■ See chart below for minimum dimming levels ■ Consult dimming manufacturer for installation instructions

    DRIVER120V INPUT

    FROM DIMMER

    BLACK - NEGATIVE

    LED LIGHT ENGINE

    RED - POSITIVEBLACK

    WHITE

    GREEN

    COMPATIBLE DIMMERS MX MODULE DIMS DOWN TOProduct Part Number(s) Type L0 L1 L2 L3Leviton IPE04 Reverse 8% 6% 8% 8%Leviton IPI06-1LZ Forward - 1% 1% 1%Leviton 6633-P Forward 1% 1% 1% -Lutron DVELV300P Reverse 8% 6% 9% 9%Lutron DVCL-153P Forward 1% 1% 1% 1%Lutron S600P Forward 3% 1% 2% 2%Cooper DLC03P Forward - 1% 1% 2%Cooper DAL06P Forward - 1% 1% 1%

    DRIVERINPUT

    GREY (-)

    0-10V DIMMER

    BLACK - NEGATIVE

    LED LIGHT ENGINE

    RED - POSITIVE

    VIOLET (+)

    BLACK

    WHITE

    GREEN

    0-10V DIMMING ■ 120V/277V ■ Dims down to 1% or 0.1% light output ■ Consult dimming manufacturer for installation instructions and power packs

    COMPATIBLE DIMMERSManufacturer Part Number(s)HUNT PS-010-IV-120V, PS-010-WH-120V, PS-010-3W-IV-120, PS-010-3W-WH-120V, PS-010-IV-277V, PS-010-WH-277V, PS-010-3W-IV-277V, PS-010-3W-WH-277V, FD-010: PS-IFC-010-IV, PS-IFC-010-WH-120/277V, FD-010: PS-IFC-010-3W-IV, PS-IFC-010-3W-WH-120/277V, FD-010-120V, FD-010-277VLeviton Leviton Centura Fluorescent Control System, IllumaTech™ IP7 Series, DPSPE-212Lightolier ZP600FAM120, MP1500FAM120, V2000FAMULithonia LEQ BC, LEQ LVBC, SLD LVBC, SQ1DCLutron DVTV, NTFTVSynergy ISD BC 120/277

    INSTRUCTIONS L/M-10022017 P-5

    INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2017 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

    IS-C1031R25 OF 6

  • Installation Instructions3.5” MX Pendant - Dimming Compatibility

    LUTRON ECOSYSTEM® DIMMING - 120V or 277V - Dims down to 1% - Consult dimming manufacturer for installation instructions

    COMPATIBLE DIMMERSProduct Part Number(s)EcoSystem CS-1L-WM, CS-2L-WM, CS-1L-CM, CS-2L-CM, EcoSystem ESN, Grafik Eye QS with EcoSystem, Quantum

    DRIVER

    ECO SYSTEM CONTROL

    (BY OTHERS)

    ECO SYS BUS

    BLACK - NEGATIVE

    LED LIGHT ENGINE

    RED - POSITIVE

    VIOLET (E1)

    VIOLET (E2)

    BLACK

    WHITE

    GREEN

    DRIVER

    3-WIRE CONTROL

    (BY OTHERS)BLACK - NEGATIVE

    LED LIGHT ENGINE

    RED - POSITIVEBLACK

    WHITE

    GREENORANGE

    LUTRON HI-LUME® DIMMING - 120V or 277V - Dims down to 1% - Consult dimming manufacturer for installation instructions

    COMPATIBLE DIMMERSAYF-103P, AYF-103P-277, DVF-103, DVF-103P-277, DVSCF-103P, DVSCF-103P-277, HQRD-F6AN-DV, LXF-103PL, LXF-103PL-277, NF-10, NF-103P, NF-103P-277, NF-10-277, NTF-10, NTF-103P, NTF-103P-277, NTF-10-277, RRD-F6AN-DV, SF-12P-277-3, SF-103P, MAF-6AM, MAF-6AM-277, MSCF-6AM, MCSF-6AM-277, MRF2-F6AN-DV, SF-10P, SF-12P-277, SPSF-6A, SPSF-6A-277, SPSF-6AM, SPSF-6AM-277, VF-10, VTF-6AM

    INSTRUCTIONS L/M-10022017 P-6

    INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2017 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.