warning important safety instructions warning · installation instructions 3.5” mx pendant -...
TRANSCRIPT
-
Installation Instructions3.5” MX Pendant - Pendant Mounted
IMPORTANT SAFETY INSTRUCTIONS – Read all installation instructions before installing. It is important to save these instructions. – Only install and connect LED module with power disconnected at the circuit breaker. Hot plugging, or connecting the module with power
on, could damage the LEDs and is not covered by warranty. – Observe and follow all label information and instructions regarding dry, damp and wet location listings, proper Intense LED module,
warnings of installation near combustible materials and/or insulation. – Be sure to connect ground wire to prevent electric shock or other potential hazards. – The product must be installed in a manner consistent with the intended use and in compliance with the national electrical codes and local
codes by a person familiar with the construction and operation of the product and the hazards involved. – WARNING: Use only Intense Lighting trims listed for use with this fixture. Use of trims other than those listed by Intense Lighting is a
violation of N.E.C 110-3(B) and voids all warranties.
WARNING
Risk of electrical shock. Disconnect power before servicing or installing luminaire.
!
WARNING
Risk of injury or damage. Luminaire will fail if not installed properly. Follow
installation instructions.
!
WARNING
Risk of injury. Wear safety glasses and gloves during installation and servicing.
Allow ample time to cool before handling.
!
M3 x 10mm Flat Head
TOP COVER REMOVAL:1. Remove all four M3 x 10mm flat head fasteners and keep for use on lid replacement.
1 2
43
FASTENING PENDANT STEM TO FIXTURE:1. Slide pendant stem through
canopy and screw one hex nut before lid and another after lid. Leave 1/4” of pendant thread after lid. Tighten hex nuts together and ensure stem is securely fastened to lid.
Canopy
Pendant Stem
Threaded Knuckle With Set Screw
Hex Nut
Top Cover With Driver Plate Attached
M3 X 10mm Flat Head
Driver Wires
WIRING PENDANT STEM:1. Feed wires through pendant stem2. Make necessary wire connections securely
TOP COVER INSTALL:1. Replace top cover with four M3 x 10mm flat head fasteners
INSTRUCTIONS L/M-10022017 P-1
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2017 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
IS-C1031R21 OF 6
-
7
6
STEM ATTACHMENT TO UNIVERSAL PLATE1. Make sure to leave a slight space between supplied hex nuts attached to the stem2. Hang the stem onto the universal plate at the center retaining area, making sure wire
connections are inside jbox area and securing canopy cover in position as shown3. Tighten bottom hex nut below the universal plate to secure stem attachment4. Place canopy cover against the universal plate for tooless attachment
ELECTRICAL CONNECTIONS1. Make electrical connections through the clearance area of the universal plate2. Connect ground wire from universal mounting plate to green (ground) supply wire and
ground wire from fixture, white wire from cylinder to white (neutral) supply wire and black wire from cylinder to black (hot) supply wire. Use UL listed connectors or wire nuts (by others) to make the connections. Connect dimming wires if applicable, see page 4 & 5.
Installation Instructions3.5” MX Pendant - Pendant Mounted
Bottem Hex Nut
Top Hex Nut
Universal Plate
Canopy Cover
5ATTACH MOUNTING BRACKET TO JUNCTION BOX:1. Attach universal plate to junction box2. Run wires through center clearance area of universal plate3. Attach universal mounting plate to junction box by 2 x 8-32 pan head screws4. Insure universal plate is flush to ceiling line and free of joint compound and debris
8-32 Pan Head
Universal Slot Attachment
3.0 Box Keyed Attachment with Mud plate
4.0 Box Keyed Attachment
INSTRUCTIONS L/M-10022017 P-2
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2017 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
IS-C1031R22 OF 6
-
Installation Instructions3.5” MX Pendant - Remote Driver & Accessories
Release Cap
Accessories
Accessory Holder
Accessory Holder’s Retaining Clip
Module
ACCESSORY HOLDER:1. Rotate release cap by turning counter clockwise.2. Install accessories into accessory holder and replace accessory holder’s retaining clip.3. Place accessory holder and accessory flush against optic and replace release cap.
OPTIC REPLACEMENT:1. Remove trim, then remove module from channel and disconnect quick connect.2. Rotate release cap by turning counter clockwise.3. Set cap and retainer ring aside and change optics.4. Align optic pins to slots in module.
Release Cap
Retainer Ring
Optic
ModuleOptic Slots
1 2
Remote Driver Housing Installation
Accessory & Optics Installation
REMOTE BOX INSTALLATION1. Remove two 8-32 fasteners and save to reinstall cover plate2. Remove cover plate3. Remove required knockouts and run conduit to junction box fixture is attached to
(**maximum 50 feet length from fixture”)
Remote Box
Cover Plate
Two 8-32 Fasteners Supllied With Housing
REMOTE BOX INSTALLATION1. Run connecting wires for LED driver class 2 by local and national electrical regulations,
minumun 18 awg wire and at maximum 50 feet length2. Attach remote box at two 1/4” holes on 6 inch centers with frame in installation
hardware (supplied by others)3. Make electrical connections (See Page 2, Step 6)4. Reinstall cover plate with supplied 8-32 hardware, insure wires are clear of box edges
not pinched or damaged when cover is screwed down
NOTE: ***NOT RATED FOR THROUGH WIRING***
Suppliesby others
Ground Fastener
LED Driver Cover Supplies
by others
Frame In Installation Hardware (Supplied By Others)Two Ø1/4” Holes On 6 Inch Center
INSTRUCTIONS L/M-10022017 P-3
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2017 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
IS-C1031R23 OF 6
-
Installation Instructions3.5” MX Pendant - Pendant Mounted
DRIVER REPLACEMENT: DRIVER TYPE 1: DRIVER REPLACEMENT: DRIVER TYPE 2:M3 x 10mmFlat Head
Driver Plate Driver Plate
8-32 Nut
M3 Nut
Bottom Feed Driver
M3 x 10mmFlat Head
M3 Pan Head
Small, Side Feed Driver
Fixture Maintenance
Trim
figure 1
MODULE REMOVAL1. Check that power is off at breaker, hot plugging may damage leds2. Remove Trim (see figure.1)3. Insert #1 flat head screw driver between optic and module cap as shown on detail call out (round pendant only, square pendant use finger to grip module at cap) pull down gently (see figure.2)4. *Take caution not to scratch surface of optic during this step, use #1 flat screw, larger screw driver may damage module*5. Grasp module with hand and fully remove from housing (see figure 3)6. Disconnect quick connect from fixture to module7. Install Follow Steps In Reverse
*Snap module into channel and confirm module sits parallel to ceiling line and is securely fastened into fixture before reattaching trim or turning power back on to fixture*
figure 3
Quick Connect
Module
Channel
25.00°
B B
C
SECTION B-BSCALE 1 : 1
DETAIL CSCALE 2 : 1
25.00°
B B
C
SECTION B-BSCALE 1 : 1
DETAIL CSCALE 2 : 1
#1 Flat Head Screw Driver
Detailed View
figure 2
Module Cap
Optic
INSTRUCTIONS L/M-10022017 P-4
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2017 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
IS-C1031R24 OF 6
-
Installation Instructions3.5” MX Pendant - Dimming Compatibility
DMX512 RDM DIMMING ■ 120V or 277V ■ Dims down to 0.1% light output ■ RDM channel programmable
LED LIGHT ENGINE
DMX512 IN
120 OR 277V INPUT
DRIVER
ORANGE (DMX -)
BROWN (DMX GROUND)
ORANGE/WHITE (DMX +)
BLACK
WHITE
GREENBLACK - NEGATIVE
RED - POSITIVE
FORWARD / REVERSE PHASE DIMMING ■ 120V only ■ See chart below for minimum dimming levels ■ Consult dimming manufacturer for installation instructions
DRIVER120V INPUT
FROM DIMMER
BLACK - NEGATIVE
LED LIGHT ENGINE
RED - POSITIVEBLACK
WHITE
GREEN
COMPATIBLE DIMMERS MX MODULE DIMS DOWN TOProduct Part Number(s) Type L0 L1 L2 L3Leviton IPE04 Reverse 8% 6% 8% 8%Leviton IPI06-1LZ Forward - 1% 1% 1%Leviton 6633-P Forward 1% 1% 1% -Lutron DVELV300P Reverse 8% 6% 9% 9%Lutron DVCL-153P Forward 1% 1% 1% 1%Lutron S600P Forward 3% 1% 2% 2%Cooper DLC03P Forward - 1% 1% 2%Cooper DAL06P Forward - 1% 1% 1%
DRIVERINPUT
GREY (-)
0-10V DIMMER
BLACK - NEGATIVE
LED LIGHT ENGINE
RED - POSITIVE
VIOLET (+)
BLACK
WHITE
GREEN
0-10V DIMMING ■ 120V/277V ■ Dims down to 1% or 0.1% light output ■ Consult dimming manufacturer for installation instructions and power packs
COMPATIBLE DIMMERSManufacturer Part Number(s)HUNT PS-010-IV-120V, PS-010-WH-120V, PS-010-3W-IV-120, PS-010-3W-WH-120V, PS-010-IV-277V, PS-010-WH-277V, PS-010-3W-IV-277V, PS-010-3W-WH-277V, FD-010: PS-IFC-010-IV, PS-IFC-010-WH-120/277V, FD-010: PS-IFC-010-3W-IV, PS-IFC-010-3W-WH-120/277V, FD-010-120V, FD-010-277VLeviton Leviton Centura Fluorescent Control System, IllumaTech™ IP7 Series, DPSPE-212Lightolier ZP600FAM120, MP1500FAM120, V2000FAMULithonia LEQ BC, LEQ LVBC, SLD LVBC, SQ1DCLutron DVTV, NTFTVSynergy ISD BC 120/277
INSTRUCTIONS L/M-10022017 P-5
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2017 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
IS-C1031R25 OF 6
-
Installation Instructions3.5” MX Pendant - Dimming Compatibility
LUTRON ECOSYSTEM® DIMMING - 120V or 277V - Dims down to 1% - Consult dimming manufacturer for installation instructions
COMPATIBLE DIMMERSProduct Part Number(s)EcoSystem CS-1L-WM, CS-2L-WM, CS-1L-CM, CS-2L-CM, EcoSystem ESN, Grafik Eye QS with EcoSystem, Quantum
DRIVER
ECO SYSTEM CONTROL
(BY OTHERS)
ECO SYS BUS
BLACK - NEGATIVE
LED LIGHT ENGINE
RED - POSITIVE
VIOLET (E1)
VIOLET (E2)
BLACK
WHITE
GREEN
DRIVER
3-WIRE CONTROL
(BY OTHERS)BLACK - NEGATIVE
LED LIGHT ENGINE
RED - POSITIVEBLACK
WHITE
GREENORANGE
LUTRON HI-LUME® DIMMING - 120V or 277V - Dims down to 1% - Consult dimming manufacturer for installation instructions
COMPATIBLE DIMMERSAYF-103P, AYF-103P-277, DVF-103, DVF-103P-277, DVSCF-103P, DVSCF-103P-277, HQRD-F6AN-DV, LXF-103PL, LXF-103PL-277, NF-10, NF-103P, NF-103P-277, NF-10-277, NTF-10, NTF-103P, NTF-103P-277, NTF-10-277, RRD-F6AN-DV, SF-12P-277-3, SF-103P, MAF-6AM, MAF-6AM-277, MSCF-6AM, MCSF-6AM-277, MRF2-F6AN-DV, SF-10P, SF-12P-277, SPSF-6A, SPSF-6A-277, SPSF-6AM, SPSF-6AM-277, VF-10, VTF-6AM
INSTRUCTIONS L/M-10022017 P-6
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2017 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
IS-C1031R26 OF 6